Lupus Electronics LUPUSEC XT User manual

XT Keypad
Manual

Introduction
Thank you for purchasing the LUPUSEC XT keypad. Before you install the keypad,
please take the time to read the following safety and installation information carefully
and attentively. It is imperative to comply with these instructions in order to ensure
the safe operation. If you have any further questions, please contact your local
retailer or LUPUS-Electronics directly. Your LUPUSEC XT keypad was developed
and built with state-of-the-art technology and complies with European and German
standards. Declarations of conformity are available on request or for download at
www.lupus-electronics.de.
Please keep this manual safely to be able to answer possible questions in the future.
The manual is an integral part of the product even in case it is resold to a third party.
Disclaimer
All technical details and descriptions in this manual have been written with the
greatest care. However, LUPUS-Electronics cannot entirely exclude mistakes in this
manual. Therefore, we do not assume any legal responsibility or liability, which is the
result of wrong information in this manual. Descriptions, technical images and
technical data are subject to change according to technical progress. In addition,
LUPUS-Electronics reserves the right to change this product and its manual without
prior notice. We do not assume any guarantee with regard to the content of this
document. We appreciate any comments on mistakes or inaccuracies, which may
help us to improve this product and this manual.
This symbol is intended to attract the user’s attention to the potential risk of
dangerous unprotected voltage inside the housing. This may lead to an
electric shock.
This symbol is intended to attract the user‘s attention to use and
maintenance instructions in the manual and documents enclosed to the
product.

WARNING:
TO MINIMIZE THE RISK OF AN ELECTRIC SHOCK, YOU MUST NOT EXPOSE
THIS PRODUCT TO WET AND MOIST CONDITIONS AT ANY TIME.
All LUPUS-Electronics products are lead-free and meet the
requirements stated under the European Directive on the Restriction of
Hazardous Substances (RoHS). This guarantees that the entire
production process and the product itself are free of lead and of all
listed hazardous substances.
This product was tested and complies with the regularities for a class of
digital devices stated under FCC part 15. These limits were specified to
provide reasonable protection against harmful exposure when operating
the device in a commercial environment. This product emits and uses
radio energy. It may in addition interfere with other radio communication
systems, if it is not installed or used according to this manual. Using the
device in residential areas may cause disturbances to be possibly
remedied at the user’s expense.
If installed properly according to this manual, the product LUPUSEC –
XT keypad (Item. No. 12001, EAN 4260195431867), complies with CE
regularities of directive 1999/5/EG.
Conformity:
The declaration of conformity is available at:
LUPUS-Electronics GmbH
Otto-Hahn-Str. 12
76829 Landau

Important safety information
Warning
The warranty claim will expire in case of damages resulting from
the non-observance of this manual.
We do not assume any liability for consequential damages.
We do not assume any liability for damages to persons and/or
material whatsoever, which result from improper handling or
noncompliance with the safety instructions. The warranty claim will
expire in such cases!
The LUPUSEC XT keypad is equipped with a high-quality housing. However, please
observe the following safety regulations:
Connect the XT keypad only to the approved batteries and voltage
according to this manual.
Handle the XT keypad with care, heavy vibrations or bumps may damage
the XT keypad.
Do not expose the XT keypad to direct sunlight or strong sources of heat
(e.g. heaters).
Do not use the XT keypad close to strong electric power lines or magnetic
fields, as this may impair the transmission quality significantly.
Do not install the XT keypad directly on iron or aluminium surfaces without
isolating the XT keypad from these surfaces, as these materials may
impair the wireless transmission significantly.
Do not expose the XT keypad to moist, very cold or very hot
environments. Please observe the maximum humidity and temperature
limits.
The XT keypad is only designed for indoor use (no protection class).
Persons (including children) with limited physical, sensory, or mental
abilities and/or lacking experience and/or knowledge must not use this
product.
Keep children away from the XT keypad and other connected electric
appliances at all times. The XT keypad includes small parts, which they
may swallow. Assemble the XT keypad out of children’s reach. Do not
leave packaging materials unattended, they may be dangerous for playing
children.
Use a damp cloth to clean the XT keypad’s surface. Afterwards, dry the
surface. Cleaning agents will damage the surface.
Detection of defects
If you notice any kind of defect, disconnect the XT keypad from the power supply
(the battery) and contact your retailer or LUPUS-Electronics directly. Any further
usage of the XT keypad may lead to fire or electric shock!

Designated use
The XT keypad is designed to arm or disarm your XT alarm panel. The XT keypad is
designed for indoor usage (no protection class). Any other use than described in this
manual is not permitted and will lead to the expiry of any warranty or guarantee as
well as to the exclusion of liability. The same applies to modifications and retrofitting.
Information on disposal:
Do not dispose of the device with the domestic waste!
This product complies with the EU Directive on waste electrical and
electronic equipment (WEEE) and therefore must not be disposed of with the
domestic waste. Dispose of the device via your local collection point for
waste electronic equipment!
This product contains software programs subject to the GPL free software
license.
This product contains software that was developed by third parties and/or software
subject to the GNU General Public License (GPL) and/or the GNU Lesser General
Public License (LGPL). We will send you the source code of these programs on
request. The GPL and/or LGPL code used and offered in this product is EXCLUSIVE
OF ANY GUARANTEE WHATSOEVER and is subject to the copyright of one or
several authors. For further details, please refer to the GPL and/or LGPL code of this
product and to the terms of usage of GPL and LGPL.
You can read the complete license text at http://www.gnu.org/licenses/gpl-2.0.html.
For the unofficial German translation, please go to
http://www.gnu.de/documents/gpl.de.html.

XT Keypad
Product description:
1. Power LED
2. Status LED
3. Error LED
4. Arm
5. Home
6. System status
7. Disarm
8. Pound key #
9. Star key *
Installation mode = Installation PIN + *
10.Emergency alarm: 7 + 9 (simultaneously)
11.Fire alarm: 4 + 6 (simultaneously)
12.Panic alarm: 1 + 3 (simultaneously)
13.Battery breaker (delivery status)
14.Mounting holes
15.Tampering contact
Note: The dual-key commands 1+3 (12.), 2+6 (11.), 7+9 (10.) are disabled by default.
LED indicators:
Power LED:
oLED lights up orange: test mode is
active
oLED flashes orange: test mode is
active + low battery
oLED lights up blue for approx. five
seconds: System status is normal
oLED flashes blue: Low battery
Note:
Normally all LEDs are off.
If you press any key, the power LED will
light up blue for five seconds. This signals
that the keypad is operational.
Status LED (allows you to check the status of the alarm panel):
If you press the status button of the keypad, the status LED will display the
current status of the alarm panel:
LED lights up red: alarm panel is in arm mode
LED flashes red: alarm panel is in home mode
LED lights up blue: alarm panel is in disarm mode
LED flashes blue: an error occurred, e.g.:
oAlarm panel does not respond
oIncorrect PIN code

oAttempted to switch to home mode while the alarm panel is in arm
mode
oForced activation of arm mode while alarm panel or sensors report an
error
Error LED:
LED flashes orange: system error, e.g.:
oNo SIM card
oGSM not ready
oOpen tampering contact
oPower failure
oSensor is out of range
oSensor is open
oBattery of a sensor is low
Battery:
The keypad requires a 1/2AA 3V 850mAH lithium battery. The average battery
life is two years.
If the battery is low, the orange status LED flashes
Connecting the XT keypad and putting it into operation
Installation of the keypad:
1. Remove the front cover of the keypad by unscrewing the screw at the
bottom.
2. At the back cover you find two cavities. They are intended to be pierced –
thus, you can mark the locations for required drill holes for a wall
installation.
3. Use screws to install the keypad on a wall.
4. Attach the front cover again.
Connecting the keypad to the alarm panel:
1. Enter the installation mode of the keypad by entering the installation-PIN
(default: 0000) and pressing the * button. The power LED will light up
orange.
2. Open the main menu of the alarm panel.
3. Open the menu “Sensors” “Add.”
4. Click “Start.”
5. Press * and then 7 on the keypad. The keypad emits a signal and will be
listed in the alarm panel.
a. If you do not hear a signal, the alarm panel did not receive the
connection request of the keypad.
b. If the connection request was received by the alarm panel, you will
hear three short signal sounds.
6. Add the keypad to the alarm panel by pressing “Add” next to the keypad in
the menu “Sensors” “Add.”
7. Start the range test in the menu “Sensors” “Range” and take the keypad
to the intended place of installation.
8. Press * and then 7 on the keypad.
9. Check the signal strength in the “Range” menu of the alarm panel (1-9).

10.To exit the installation mode, press the disarm button two times. The
keypad emits a signal sound and the power LED is switched off.
Now you can arm and disarm the alarm panel by means of the keypad.
Changing the PIN code to switch between the different modes of the alarm
panel:
You can change the PIN code in the web interface of the alarm panel. Open the
menu “Home” “Pin codes” and change the existing PIN code or enter a new one.
Controlling the alarm panel by means of the keypad:
1. Arm the alarm panel:
PIN code (default 1234) + arm button (a long signal is emitted + the
status LED lights up).
2. Disarm the alarm panel:
PIN code (default 1234) + disarm button (two signals are emitted + the
status LED lights up blue).
3. Switch to home mode:
PIN code (default 1234) + home button and press 1, 2, or 3 to select
the corresponding home mode (three signals are emitted + the status LED
flashes red). If you do not press any number key after pressing the home
button, the alarm panel will switch to home mode 1.
Dual-key functions:
The keypad features pre-defined dual key commands that allow you to trigger a fire,
panic, or medical alarm without entering a PIN code. To activate the dual key
functions, please proceed as follows:
Enter the installation mode of the keypad (default 0000 + *). The power LED lights
up orange. To activate the dual key function, you need to enter the following
commands for the corresponding functions:
Activate panic alarm 1+3: press * + 2
Activate fire alarm 4+6: press * +3
Activate medical alarm 7+9: press * + 4
Deactivate all dual key functions: press * + 5
Note (only XT2):
If you got to the menu “Sensors” “List” and edit the keypad, you can define the
dual key commands (1+3, 4+6, 7+9). Thus, for instance, you can trigger individual
automations or directly switch to the home mode 2 or 3. A in detail description of the
different automation rules can be found in the chapter on Smarthome in the XT
manual.
Additional functions of the installation mode:
Adding the keypad to the alarm panel: press * + 7
Changing the installation PIN: press * + 6
Enter the current installation PIN (default 0000).
Press the status button . A long signal is emitted.
Enter your new installation PIN code (4-digits).
Press the pound button (#). The new installation PIN code is now saved.

Enable switching to arm / home mode without entering a PIN code: press * + 8
Disable switching to arm / home mode without entering a PIN code: press * + 9
To exit the installation mode, press the disarm button two times.
Reset / factory default:
If you have forgotten your installation PIN code, you can restore the factory default of
the keypad in the following way:
1. Open the keypad. Be aware that the tampering protection will be triggered!
2. Remove the batteries.
3. Press and hold the button “3” while you are inserting the batteries again.
4. Release the button “3.”
After the reset, the installation PIN code will again be 0000.
Please note:
Attention: Change the standard PIN code (1234) as well as the
installation PIN code (0000) of the keypad to ensure that no one else
can control your alarm panel! You can change the PIN code in the menu
“Home” “PIN codes” of the alarm panel. To change the installation PIN
code, see above.
In the menu “Settings” “Panel” “Area Settings” “Arming with failure”
you can allow that the alarm panel will always switch the mode irrespective
of errors.
If an error is displayed by a flashing error LED, it can be ignored by
entering the PIN code and the mode command again within ten seconds.
You can check (and deactivate / ignore) the current errors of the alarm
panel in the menu “Home” Status” “XT2 Status.”
The keypad only transmits status information when you enter a command.
Thus, it can transmit that the batteries are running low, but not that the
batteries are empty!
Additional notes (only XT2):
To activate different home modes with the keypad, at least firmware
version 0.0.2.7M is required. The keypad may not be older than September
2014.
Depending on the used PIN code, the keypad can control both areas
(requires at least firmware 0.0.2.7M).
In firmware version 0.0.2.13C, a “PIN code protection” was integrated. After
five incorrect PIN code inputs, the keypad is locked for 15 minutes. You
can enable or disable the “PIN code protection” in the menu “Settings”
“Panel” “General Settings.”
LUPUS-Electronics® GmbH
Otto-Hahn-Str. 12, D-76829 Landau
Tel. +49 (0) 6341 93 55 3 0 Fax. +49 (0) 6341 93 55 3 20
E-Mail: info@Lupus-Electronics.de
www.Lupus-Electronics.de