Luster TeraBand CableTRAN Series User manual

CableTRAN Series MoCA1.1+ CPE
User Manual
Luster TeraBand Photonics Co., Ltd

2
CableTRAN Series MoCA1.1+ Controller User Manual
Product Overview
CableTRAN series MoCA1.1+ CPE is indoor equipment including standard, customized,
two network ports and four network ports equipment. It adopts technology of MoCA1.1+ and
can be used in high-quality coaxial two-way network rebuilding project. It supports video, data
and voice services.
Packing List
Please check all the objects before installing this product and if there is any part loss or
damage, please contact us.
1. One CME2000 series CPE
2. Two data lines (cat 5) (Optional)
3. One coaxial cable(Optional)
4. One power adapter
5. One pedestal (Optional)
6. One user manual
7. One certification
Attention
1.Operation Environment
2) Operation temperature: -10℃——55℃
3) Operation humidity: 5%——90%, No Condensation
2.Safety Instruction
1) Do not try to repair the machine, all the maintenance work needs to be done by
certified professional technicist to avoid electric shock.
2). Do not fill anything in the opening of the machine.
3) Please disconnect the power before cleaning the machine. Please use humid and
soft cloth to wipe the machine and do not use water, paint thinner, benzene and
other strong cleaning agent.
4) Please keep power off, coaxial cable and network cable out to avoid lightening stroke
in thunderstorm day.
5) Please turn off the power and inform us when there is something wrong with the
machine.
Two Network Ports Interface Instruction

3
CableTRAN Series MoCA1.1+ Controller User Manual
1. Back Interface
Interface
Instruction
TV OUT
(Wired output)
Television signal output, used to connect TV, set-top box,
metric interface
CABLE IN
Coaxial input
Wired television signal input, used to connect coaxial
network, metric interface
LAN1
(Set Top Box)
100M Ethernet interface, used to connect computer,
set-top box, etc., RJ45 interface
LAN2
(Computer)
100M Ethernet interface, used to connect computer,
set-top box, etc., RJ45 interface
DC 5V
DC 5V power interface, used to connect original power
adapter.
2. Indicator Light
Indicator Light Instruction
Indicator Light
Instruction
Function
PWR
Power Indicator
Off: Power disconnected or broken

4
CableTRAN Series MoCA1.1+ Controller User Manual
Light
On: Power works normally
COAX
Coaxial Connection
Indicator Light
Off: Coaxial disconnected
On: CPE is connected to network
Flicker: Sending and receiving data
SYS
System Indicator
Light
Off:System is not started
On: System is started normally
LAN1-2
Network Connection
Indicator
Off: User equipment disconnected
On: User equipment is connected normally
Flicker: Sending and receiving data
3. Slide power switch on the side
Default is power-off on the left and power-on on the right.
Four Network Ports Interface Instruction
1.Back interface
Interface
Instruction
TV OUT
(Wired output)
Television signal output, used to connect TV, set-top box,
metric interface

5
CableTRAN Series MoCA1.1+ Controller User Manual
CABLE IN
Coaxial input
Wired television signal input, used to connect coaxial network,
metric interface
LAN1
(Computer)
100M Ethernet interface, used to connect computer, set-top
box, etc., RJ45 interface
LAN2
(Set Top Box)
100M Ethernet interface, used to connect computer, set-top
box, etc., RJ45 interface
LAN3-4
100M Ethernet interface, used to connect computer, set-top
box, etc., RJ45 interface
DC 5V
DC 5V power interface, used to connect original power adapter.
2. Indicator Light
Indicator Light Instruction
Indicator Light
Instruction
Function
PWR
Power Indicator
Light
Off: Power disconnected or broken
On: Power works normally
COAX
Coaxial Connection
Indicator Light
Off: Coaxial disconnected
On: CPE is connected to network

6
CableTRAN Series MoCA1.1+ Controller User Manual
Flicker: Sending and receiving data
SYS
System Indicator
Light
Off:System is not started
On: System is started normally
LAN1-4
Network Connection
Indicator
Off: User equipment disconnected
On: User equipment is connected normally
Flicker: Sending and receiving data
3. Slide power switch on the side
Default is power-off on the left and power-on on the right.
Installation
1.Attention
In order to guarantee normal work of equipment and extend service life, please follow the
following regulations during the process of installation:
1)Please handle gently during the process of installing and moving equipment.
2) Please use the original power adapter.
3) Please put the machine on the horizontal or vertical place, far from heat source, avoid
getting wet and keep ventilation.
4) Please put the machine in the dry environment with no dust.
5) Please connect the coaxial cable when the equipment is power off.
6) Please check the user circuit and make sure there is no defective joint and all the joint
must be tighten.
2.Installation Steps
1)Coaxial cable connection
Connect the service wire of operator with “CABLE IN”interface;
TV OUT should be connected with TV, Set Top Box from coaxial cable.
RF interface of optical receiver with TV IN1;
Connect the RF OU1 with the branch distributor network.
2)Ethernet connection
Use Ethernet cable to connect the interface of user equipment with the interface of

7
CableTRAN Series MoCA1.1+ Controller User Manual
this equipment.
3)Power connection
Connect the power adapter and turn on the power, and then check whether the
indicator light is normal or not.
Failure Diagnosis
If there is anything wrong with the machine during the operation, users can do some
simple check and handling. If the problem cannot be solved, please contact us as soon as
possible.
Problem Description
Handling Method
PWR indicator light off
1. Check if the power adapter plug well
2. Turn to another power socket
COAX indicator light off
1. Check if the service line is normal by television signal
2. Check if the coaxial cable is tightened
3. Restart the machine (power off first and then power on)
SYS indicator light off
1. Restart the machine (power off first and then power on)
LAN1-4 indicator light off
1. Check if the network cable works normal
2. Check if the user equipment works normal
3. Restart the machine (power off first and then power on)
Luster TeraBand Photonics Technology Co., Ltd.
Address: 4/F, Building D, Jiading Science Park of Shanghai University, 1355 Chengbei Road,
Jiading District, Shanghai, China (ZIP Code: 201807)
Hotline for technical supports: 8621-69925055
Fax: 8621-69925066
E-mail: support@lusterinc.com

8
CableTRAN Series MoCA1.1+ Controller User Manual
Product Warranty Card
NO. Purchase Date:
Customer
Tele
Address
Product Type
Serial Number
Warranty Period
One year
Explaination
Lifetime
Warranty
Welcome to use our product.
Failure
Instruction
1. Since the purchase date, the machine can be
repaired for free by this warranty card during the
warranty period.
Remark
2. The repair service needs to be charged when
the failure is caused by nature reason, unproper
operation or beyond the warranty period.
Table of contents
Popular Wireless Access Point manuals by other brands

Berker
Berker 4582 Operating and assembly instruction

Corega
Corega CG-WLAPGMN user manual

Zonet
Zonet ZEW3002 Quick installation guide

MikroTik
MikroTik hAP ac3 LTE6 kit quick start guide

Ruckus Wireless
Ruckus Wireless ZoneFlex H500 Quick setup guide

Wireless Joey
Wireless Joey Dish installation instructions