Lutron Electronics 33-00155EFS User manual

Wireless Thermostat
Installation Guide
Current display. Underlined label
signifies the current display.
Mode control buttons. Use to change
settings for Fan or System Heat/Cool.
Menu. Select options to: set schedules,
view equipment status, change IAQ
settings, access installer options*, etc.
Current status. Shows system mode
(heat/cool), outdoor temperature and
humidity.
Current schedule. Shows desired
temperature and schedule status.
Indoor conditions. Shows indoor
temperature and humidity.
Current Time.
Alert Light. On when alert
message is active or system is set to
Em Heat.
Reference to key features
* Password is the date code.

2
1 Separate wallplate from thermostat.
Press button on top and pull to remove
the wallplate.
Wallplate
(back view)
Thermostat
Button
Getting started
Follow these basic steps to install this thermostat,
set installer options, and connect to the Wi-Fi
network.
NOTE: For the product specifications, please go
to www.lutron.com
Installing the thermostat
Residential/Résidentiel
1-800-468-1502
http://yourhome.honeywell.com
Commercial/Commerciale
1-888-245-1051
http://customer.honeywell.com
Honeywell, Golden Valley, MN 55422
RoHs Compliant
Conformité RoHs
Assembled in Mexico
Assemblé au Mexique
TH8321WF1001
1
1524
M35344
1-855-733-5465
yourhome.honeywell.com
Honeywell
Golden
Valley, MN 55422
RoHs Compliant
Conformité RoHs
Assembled in Mexico
Assemblé au Mexique
1524
M35343A
Thermostat (back view)
Password
(Date Code)
ATTENTION: MERCURY RECYCLING NOTICE
This product does not contain mercury. However, this
product may replace a product that contains mercury.
Mercury and products containing mercury should not be
discarded in household trash.
For more information on how and where to properly recycle
a thermostat containing mercury in the United States,
please refer to the Thermostat Recycling Corporation at
www.thermostat-recycle.org.
For mercury thermostat recycling in Canada, please refer
to Switch the Stat at
www.switchthestat.ca
NO MERCURY
Hg

3
3 Connect power.
24VAC power is required. Connect
common side of transformer to C
terminal.
S1
S1
W
Y
G
W2
Y2
A
S1
S1
O/B
Y
G
AUX
-E
Y2
L/A
K
RC
R
U1
U1
U2
U2
C
CONVENTIONAL
HEAT PUMP
2 Mount wallplate as shown.
Mount new wallplate using screws
and anchors included with the
thermostat.
Drill 3/16-in holes for drywall.
Drill 7/32-in holes for plaster.
Wallplate
S1
S1
W
Y
G
W2
Y2
A
C
K
R
C
R
U1
U1
U2
U2
S1
S1
O/B
Y
G
AUX
-E
Y2
L/A
4 Wire the thermostat.
Refer to the table and wiring
diagrams on the next page.
a Turn on 24VAC NOW.
24VAC (C wire) is required.
S1
S1
W
Y
G
W2
Y2
A
S1
S1
O/B
Y
G
AUX
-E
Y2
L/A
K
RC
R
U1
U1
U2
U2
C
CONVENTIONAL
HEAT PUMP
5 Mount thermostat on wallplate.
Align thermostat at bottom and
snap into place as shown.
Thermostat
Wallplate

4
Terminal Designations
Conventional System Heat Pump
Terminal Description Terminal Description
CCommon wire from secondary side of
cooling transformer (if 2 transformers). CCommon wire from secondary side of
cooling transformer.
Rc* Cooling power. Rc Cooling power.
R* Heating power. R Heating power.
W Heat Stage 1 O/B Changeover valve for heat pumps.
W2 Heat Stage 2 AUX-E Backup Heat/Emergency Heat
Y Compressor Stage 1 Y Compressor Stage 1
Y2 Compressor Stage 2 Y2 Compressor Stage 2
G Fan Relay G Fan Relay
AConnect to Economizer Module or
Lighting Panel (TOD). L/A Connect to Compressor Monitor, Zone
Panel, Economizer Module or Lighting
Panel (TOD).
U1 / U1 Universal relay for humidification,
dehumidification, ventilation, or a stage of
heating/cooling. U1 / U1 Universal relay for humidification,
dehumidification, ventilation, or a stage of
heating/cooling.
S1 / S1 Universal input for a wired indoor, outdoor
or discharge sensor. S1 / S1 Universal input for a wired indoor, outdoor
or discharge sensor.
K** Connect to K on Wire Saver module. K** Connect to K on Wire Saver module.
* Remove factory installed jumper for two transformer systems.
** The THP9045A1023 Wire Saver module is used on heat/cool systems when you only have four wires at the thermostat and you
need a fifth wire for a common wire. Use the K terminal in place of the Y and G terminals on conventional or heat pump systems to
provide control of the fan and the compressor through a single wire—the unused wire then becomes your common wire. See THP9045
instructions for more information.
C
K
RC
R
U1
U1
120
VAC
24
VAC
C
R
SYSTEM
TRANSFORMER
120
VAC
24
VAC
HUM, DEHUM OR
VENT TRANSFORM-
ER
THERMOSTAT
POWERED
HUMIDIFIER,
DEHUMIDIFIER
OR VENTILATOR
C
K
RC
R
U1
U1
120
VAC
24
VAC
C
R
SYSTEM
TRANSFORMER
THERMOSTAT
NON-POWERED
HUMIDIFIER,
DEHUMIDIFIER
OR VENTILATOR
FIELD INSTALL JUMPER
BETWEEN R AND U1
CONNECTING A HEAT OR COOL STAGE TO U1DEHUMIDIFICATION WITH LOW SPEED FAN
NON-POWERED HUMIDIFIER, DEHUMIDIFIER OR VENTILATORPOWERED HUMIDIFIER, DEHUMIDIFIER OR VENTILATOR
Wire the thermostat universal relay to the low speed fan
for dehumidication control at the equipment. The
thermostat relay can be set to normally open or
normally closed in the thermostat installer setup.
1
U1 terminals are normally open dry contacts when set
up for a stage of heating or cooling.
You must install a eld jumper if the stage of heating
or cooling is powered by system transformer. Do NOT
install a eld jumper if the stage of heating has its own
transformer.
1
2
Normally open, dry contacts
Normally closed, dry contacts
1
C
K
RC
R
U1
U1
120
VAC
24
VAC
C
R
SYSTEM
TRANSFORMER
THERMOSTAT
DEHUMIDIFICATION
WITH LOW SPEED FAN
FIELD INSTALL JUMPER
BETWEEN R AND U1
OR
2
C
K
RC
R
U1
U1
120
VAC
24
VAC
C
R
TRANSFORMER
THERMOSTAT
HEAT STAGE 3, COOL
STAGE 3, BACKUP HEAT
STAGE 2 FOR HEAT
PUMPS, OR GEOTHERMAL
RADIANT HEAT
1

5
Setup options define the type of system you are installing and preferences for the
display.
1 Follow prompts on the screen to select the appropriate options. Among the
screens you might see will be options for:
1.1 Application, either Residential or
Commercial.
1.2 Thermostat Name, which will enable
you to identify it if you’re installing
more than one thermostat (for a zoned
HVAC application, for instance).
1.3 Thermostat Type, either programmable
or not, depending on preference.
1.4 Temperature scale, either Fahrenheit
or Celsius.
1.5 Use outdoor temp.
NOTE: Choose WIRED/INTERNET if your
application will require a wired sensor, or
will use the Internet for weather data.
1.6 The type of heating system.
1.7 For all installer options, press the sor
tbuttons to change the option.
1.8 Press Next to move to the next setting,
and Done when setup is complete.
Performing installer setup
APPLICATION
residential
M34150
THERMOSTAT TYPE
programmable
M35356
THERMOSTAT NAME
THERMOSTAT
M35357
TEMPERATURE SCALE
fahrenheit
M35359
HEATING SYSTEM
conv. forced air
USE OUTDOOR TEMP
wired / internet

6
1H/1C System (1 transformer)
Rc Power [1]
R [R+Rc joined by jumper]
W Heat relay
Y Compressor contactor
G Fan relay
C 24VAC common
S1 Optional outdoor/remote sensor
Heat Only System
Rc Power [1]
R [R+Rc joined by jumper]
W Heat relay
C 24VAC common
S1 Optional outdoor/remote sensor
Heat Only System (Series 20)
Rc [R+Rc joined by jumper]
R Series 20 valve terminal “R” [1]
W Series 20 valve terminal “B”
Y Series 20 valve terminal “W”
C 24VAC common
S1 Optional outdoor/remote sensor
2H/2C System (1 transformer)
Y2 Cool relay 2
W2 Heat relay 2
Rc Power [1]
R [R+Rc joined by jumper]
W Heat relay 1
Y Cool relay 1
G Fan relay
C 24VAC common
S1 Optional outdoor/remote sensor
1H/1C System (2 transformers)
Rc Power (cooling transformer) [1, 2]
R Power (heating transformer) [1, 2]
W Heat relay
Y Compressor contactor
G Fan relay
C 24VAC common [3]
S1 Optional outdoor/remote sensor
Heat Only System With Fan
Rc Power [1]
R [R+Rc joined by jumper]
W Heat relay
G Fan relay
C 24VAC common
S1 Optional outdoor/remote sensor
Cool Only System
Rc Power [1]
R [R+Rc joined by jumper]
Y Compressor contactor
G Fan relay
C 24VAC common
S1 Optional outdoor/remote sensor
2H/2C System (2 transformers)
Y2 Cool relay 2
W2 Heat relay 2
Rc Power (cooling transformer) [1, 2]
R Power (heating transformer) [1, 2]
W Heat relay 1
Y Cool relay 1
G Fan relay
C 24VAC common [3]
S1 Optional outdoor/remote sensor
Wiring
See [notes] below
[1] Power supply. Provide disconnect means and overload protection as required.
[2] Remove jumper for 2-transformer systems.
[3] Common connection must come from cooling transformer if a 2 transformer installation.

7
1H/1C Heat Pump (no auxiliary heat)
Rc Power [1]
R [R+Rc joined by jumper]
O/B Changeover valve [4]
Y Compressor relay
G Fan relay
C 24VAC common
S1 Optional outdoor/remote sensor
2H/1C Heat Pump (with auxiliary heat)
L Equipment monitor [5]
Aux/E Auxiliary/Emergency heat relay (Heat 2)
Rc Power [1]
R [R+Rc joined by jumper]
O/B Changeover valve [4]
Y Compressor relay
G Fan relay
C 24VAC common
S1 Optional outdoor/remote sensor
2H/2C Heat Pump (no auxiliary heat)
Y2 Compressor 2 relay
Rc Power [1]
R [R+Rc joined by jumper]
O/B Changeover valve [4]
Y Compressor 1 relay
G Fan relay
C 24VAC common
S1 Optional outdoor/remote sensor
3H/2C Heat Pump (with auxiliary heat)
Y2 Compressor 2 relay
L Equipment monitor [5]
Aux/E Auxiliary/Emergency heat relay (Heat 2)
Rc Power [1]
R [R+Rc joined by jumper]
O/B Changeover valve [4]
Y Compressor 1 relay
G Fan relay
C 24VAC common
S1 Optional outdoor/remote sensor
Wiring
See [notes] below
[1] Power supply. Provide disconnect means and overload protection as required.
[4] O/B set to control as either O or B in installer setup.
[5] Heat pump reset (powered continuously when thermostat is set to Em. Heat; system monitor when
set to Heat, Cool, or Off).

8
After installer setup, you will be prompted to connect to a Wi-Fi network.
NOTE: If you select No, the homeowner
can connect to the Wi-Fi network later. (See
“Connecting to Wi-Fi later” on page 10
or in the User’s Guide.) The thermostat will
display its Home screen and thermostat
setup is complete.
1 Connect to the Wi-Fi network now.
1.1 Press Yes.
The thermostat will scan for available
Wi-Fi networks.
1.2 Use the arrow buttons to scroll up/
down or left/right. Press the Wi-Fi
network name, then press Select.
NOTE: If the Wi-Fi network name is hidden,
see “Connecting to a hidden Wi-Fi network”
on page 12.
1.3 When prompted, press the screen to
edit the password (if necessary).
1.4 Enter the password.
Press the sor t buttons to change
the letter or number.
Press the button to move to the next
character, or the button to move to
the previous character.
Use the sor t buttons at the bottom
to change letter case.
Press Done when complete.
1.5 The screen will let you know when the
connection is successful. Press Done
when the connection is successful.
If the connection is not successful,
the screen will explain why not. See
“Unsuccessful connection” on page
11. Follow instructions on the screen
to try again.
NOTE: Press the Help button for more
information about an unsuccessful connection.
Connecting to Wi-Fi
M35345
Connect to a
Wi-Fi network now?
M35346
Delete Space
AC
M35347
Select Wi-Fi Network
Your Network
M35349
Finding Networks
Please Wait
M35350
Enter Password
Press Here to Edit
M35351
Connection
Successful
M35360

9
2 The homeowner must have a Total Connect Comfort account.
2.1 Have the homeowner go to
mytotalconnectcomfort.com and follow
the instructions to login or create an
account.
2.2 Press the t button to display MAC
and CRC.
2.3 Note the Thermostat MAC and CRC; they will be needed during registration.
Or, refer to the User’s Guide.
M35361A
Register at:
Honeywell.com/TCC
• To make changes to Installer Setup
• To perform an Installer Test
Finding the password
You can find the date code
on the back of the thermostat,
or touch Menu, select Dealer Information,
and scroll to the bottom to see Date Code.
1 Touch Menu.
2 Select Dealer Information.
3 Scroll down to see the Date Code.
MCR35348
TH8321WF1001
Date Code: 1524
MCR34022
Dealer Information
Installer Options
Finding the password (Date Code)
Residential/Résidentiel
1-800-468-1502
http://yourhome.honeywell.com
Commercial/Commerciale
1-888-245-1051
http://customer.honeywell.com
Honeywell, Golden Valley, MN 55422
RoHs Compliant
Conformité RoHs
Assembled in Mexico
Assemblé au Mexique
TH8321WF1001
1
1524
M35344
1-855-733-5465
yourhome.honeywell.com
Honeywell
Golden
Valley, MN 55422
RoHs Compliant
Conformité RoHs
Assembled in Mexico
Assemblé au Mexique
1524
M35343A
Thermostat (back view)
Password
(Date Code)

10
Making changes to Installer Setup and performing an Installer Test
1 Touch Menu.
2 Select Installer Options.
3 Enter password (date code) and
touch Done. See “Finding the password” on
page 9 to find the date code.
4 Select Installer Setup or Installer Test.
5 Follow prompts on the screen to select
the desired setup options or to perform an
equipment test.
MCR33977
Enter password
0 0 0 0
MCR33976
Installer Options
MCR34015
Installer Setup
Installer Test
Checking signal strength
After you successfully connect to the Wi-Fi
network (see “Connecting to Wi-Fi” step 1.5),
the thermostat will display signal strength. The
signal strength symbols have the following
meanings:
Signal strength is 75%–100%
Signal strength is 50%–75%
Signal strength is 0%–50%
You can also check signal strength at any time after the thermostat is connected to the
Wi-Fi network by pressing MENU then Wi-Fi Setup.
Connecting to Wi-Fi later
1 Press MENU, then Wi-Fi Setup.
2 Follow the prompts on-screen (and in
“Connecting to Wi-Fi”) to select the Wi-Fi
network and enter the password.
NOTE: To view and set the Wi-Fi thermostat
remotely, the homeowner must have a Total
Connect Comfort account. See “Connecting to
Wi-Fi” step 2.
M35365
Wi-Fi Network:
YourNetwork
DoaIol Inrol Madorl
Wi-Fi Setup
Installer Options
M35352

11
Unsuccessful connection
If you are unsuccessful in connecting the thermostat to the Wi-Fi network, you will
see a Connection Failed screen. Press the t button for other tips about this failed
connection. Here are three specific reasons the connection might be unsuccessful.
For all Connection Failed screens, pressing Done will return to the Menu screen.
Invalid Password
The password you entered is invalid. Check that you have the right password and try
again.
Press Done to return to “Connecting to Wi-Fi” step 1.3 on page 8.
No IP Address
The thermostat was unable to obtain an IP address from the router. Verify the router is
correctly set up to automatically assign IP addresses. This connection can take several
minutes. If there is still no connection, remove the thermostat from the wallplate for 10
seconds, then snap it back into place.
No Internet Link
The thermostat connected to the Wi-Fi network but was unable to establish a
connection to the internet. Check the router settings and try again. Make sure the
Ethernet cable is plugged into the router and try rebooting the router if necessary.

12
If the Wi-Fi network name is hidden and it doesn’t show up in the list in “Connecting to
Wi-Fi” follow these steps to connect to it.
1 Press MENU, then Wi-Fi Setup.
2 Press Other, then press Select.
3 When prompted, press the screen to edit the
network name.
4 Enter the network name.
Press the sor t buttons to change the letter
or number.
Press the button to move to the next
character, or the button to move to the
previous character.
Use the sor t buttons at the bottom to
change letter case.
Press Done when complete.
5 Select the appropriate network security setting,
then press Select.
6 Enter the Wi-Fi network password as shown in
“Connecting to Wi-Fi” step 1.4.
Connecting to a hidden Wi-Fi network
M35346
Delete Space
AC
DoaIol Inrol Madorl
Wi-Fi Setup
Installer Options
M35352
M35353
WirelessNetwork
Other...
M35354
Enter Network Name
Press Here to Edit
M35355
SSID Security
Open Network

13
Specifications and replacement parts
Operating Ambient Temperature
Thermostat: 32 to 120° F (0 to 48.9° C)
Operating Relative Humidity
Thermostat: 5% to 90% (non-condensing)
Physical Dimensions (height, width, depth)
Thermostat: 4-15/16 x 4-5/8 x 1-1/8 inches (126 mm x 118 mm x 29 mm)
Wi-Fi Communication
Supports 802.11 B/G/N home wireless router
Frequency: 2.4 Ghz
Electrical ratings
Terminal Voltage (50/60 Hz) Max. Current Rating
W - OB 18 to 30 VAC and 750 mVDC 1.00A
Y (cooling) 18 to 30 VAC 1.00A
G (fan) 18 to 30 VAC 0.50A
W2 - Aux (heating) 18 to 30 VAC 0.60A
Y2 (cooling) 18 to 30 VAC 0.60A
A-L/A (output) 18 to 30 VAC 1.00A
U1/U1 30 VAC max. 0.50A
Power Consumption:
Operating voltage: 24 V~
Backlight on: 2.35 VA
Backlight off: 1.40 VA
Accessories and replacement parts
Accessories / Replacement Parts Honeywell Part Number
Cover Plate (covers marks left by old thermostats) THP2400A1019
Wire Saver Module THP9045A1023

© 2015 Honeywell International Inc
33-00155EFS—01 M.S. 12-15
P/N 041-539 Rev. A
Printed in U.S.A.
Lutron, , and Clear Connect are registered
trademarks of Lutron Electronics Co., Inc.
Automation and Control Systems
Honeywell International Inc.
1985 Douglas Drive North
Golden Valley, MN 55422
http://customer.honeywell.com
Lutron Electronics Co., Inc.
7200 Suter Road
Coopersburg, PA 18036-1299
USA
TEL: +1.610.282.3800
FAX: +1.610.282.1243
www.lutron.com
33-00155EFS-01
Feature L-HWLV2-WIFI
Clear Connect®, RedLINK™, or Wi-Fi Wi-Fi
Stages 3H/2C HP
2H/2C CONV
Residential or Commercial P
Dual Powered - C Wire or Battery C Wire only
Onboard Humidity Sensor P
Number of Universal Relays 1
Number of Universal Sensor Inputs 1
Economizer / TOD Output P
DISCONNECT POWER BEFORE INSTALLATION. Can cause electrical shock or equipment
damage.
MERCURY NOTICE: If this product is replacing a control that contains mercury in a sealed
tube, do not place the old control in the trash. Contact the Thermostat Recycling Corporation at
www.thermostat-recycle.org or 800-238-8192 for information on how and where to properly and
safely dispose of your old thermostat.
Must be installed by a trained, experience technician. Read these instructions carefully.
Failure to follow these instructions can damage the product or cause a hazardous condition.
Technical Assistance | 24 hours a day, 7 days a week | www.lutron.com
U.S.A. / Canada: 1.800.523.9466 | Mexico: +1.888.235.2910
Other Countries: +1.610.282.3800

Wireless Thermostat
Guide d’installation
Affichage en cours. L’option soulignée
indique l’affichage courant.
Boutons de contrôle du mode. Utilisés
pour modifier les réglages du ventilateur
ou du chauffage/refroidissement du
système.
Menu. Sélectionnez les options pour :
régler les programmes, voir l’état de
l’équipement, modifier les réglages IAQ,
accéder aux options de l’installateur*, etc.
État en cours. Affiche le mode du
système (chauffage/refroidissement), la
température et l’humidité extérieures.
Programme en cours. Affiche la
température désirée et l’état du
programme.
Conditions intérieures. Affiche la
température et l’humidité intérieures.
Heure actuelle.
Voyant d’alerte. Allumé lorsque
le message d’alerte est actif ou que
le système est réglé sur chauffage
d’urgence (Em Heat).
Référence aux caractéristiques clés
*Le mot de passe est le code de date.

2
3 Séparez la plaque murale du
thermostat.
Appuyez sur le bouton supérieur et tirez
pour retirer la plaque murale.
Plaque murale
(vue arrière)
Thermostat
Bouton
Pour commencer
Suivez ces étapes de base pour installer le
thermostat, configurer les options de l’installateur
et vous connecter au réseau Wi-Fi.
REMARQUE : For the product specifications,
please go to www.lutron.com
Installation du thermostat
Thermostat (vue arrière)
Mot de passe
(code de date)
Residential/Résidentiel
1-800-468-1502
http://yourhome.honeywell.com
Commercial/Commerciale
1-888-245-1051
http://customer.honeywell.com
Honeywell, Golden Valley, MN 55422
RoHs Compliant
Conformité RoHs
Assembled in Mexico
Assemblé au Mexique
TH8321WF1001
1
1524
M35344
1-855-733-5465
yourhome.honeywell.com
Honeywell
Golden
Valley, MN 55422
RoHs Compliant
Conformité RoHs
Assembled in Mexico
Assemblé au Mexique
1524
M35343A
ATTENTION : AVIS RELATIF AU RECYCLAGE DU
MERCURE
Ce produit ne contient aucun mercure. Cependant, ce
produit peut remplacer un produit qui contient du mercure.
Le mercure et les produits contenant du mercure ne
doivent pas être jetés aux ordures ménagères.
Pour obtenir plus d›informations pour savoir comment
et où recycler adéquatement un thermostat contenant
du mercure aux États-Unis, consultez l’organisme
de recyclage des thermostats (Thermostat Recycling
Corporation) à www.thermostat-recycle.org.
Pour le recyclage de thermostats contenant du mercure au
Canada, consultez l’organisme Switch the Stat à
www.switchthestat.ca
NE PAS JETER
LE MERCURE
Hg

3
5 Branchez l’alimentation.
Une alimentation de 24 V c.a. est
requise. Branchez le côté commun
du transformateur à la borne C.
S1
S1
W
Y
G
W2
Y2
A
S1
S1
O/B
Y
G
AUX
-E
Y2
L/A
K
RC
R
U1
U1
U2
U2
C
CONVENTIONNELLE
THERMOPOMPE
4 Montez la plaque murale comme
illustré.
Montez la nouvelle plaque murale
à l’aide des vis et ancres fournies
avec le thermostat.
Percez des trous de 3/16 po
pour les cloisons sèches.
Percez des trous de 7/32 po
pour le plâtre.
Plaque
murale
S1
S1
W
Y
G
W2
Y2
A
C
K
R
C
R
U1
U1
U2
U2
S1
S1
O/B
Y
G
AUX
-E
Y2
L/A
6 Câblez le thermostat.
Consultez le tableau et les schémas
de câblage à la page suivante.
a Mettez l’alimentation 24 V c.a. en
marche MAINTENANT. 24 V c.a.
(fil C) sont requis.
S1
S1
W
Y
G
W2
Y2
A
S1
S1
O/B
Y
G
AUX
-E
Y2
L/A
K
RC
R
U1
U1
U2
U2
C
CONVENTIONNELLE
THERMOPOMPE
7 Montez le thermostat sur la
plaque murale.
Alignez le thermostat en bas et
enclenchez-le en place comme
illustré.
Thermostat
Plaque murale

4
Désignations des bornes
Système conventionnel Thermopompe
Borne Description Borne Description
CFil commun du côté secondaire du
transformateur de climatisation (pour 2
transformateurs). CFil commun du côté secondaire du
transformateur de refroidissement.
Rc* Alimentation refroidissement. Rc Alimentation refroidissement.
R* Alimentation chauffage. R Alimentation chauffage.
W Chauffage étage 1 O/B Vanne de commutation pour les
thermopompes.
W2 Chauffage étage 2 AUX-E Chauffage de secours/Chauffage
d’urgence
Y Compresseur étage 1 Y Compresseur étage 1
Y2 Compresseur étage 2 Y2 Compresseur étage 2
G Relais de ventilateur G Relais de ventilateur
ABranchez au module d’économiseur ou
au panneau d’éclairage (heure du jour). L/A
Branchez au moniteur du compresseur,
au panneau de zone, au module
d’économiseur ou au panneau d’éclairage
(heure du jour).
U1 / U1 Relais universel pour l’humidification, la
déshumidification, la ventilation ou un
étage de chauffage/refroidissement. U1 / U1 Relais universel pour l’humidification, la
déshumidification, la ventilation ou un
étage de chauffage/refroidissement.
S1 / S1 Entrée universelle pour un capteur
d’intérieur, d’extérieur ou de soufflage
câblé. S1 / S1 Entrée universelle pour un capteur
d’intérieur, d’extérieur ou de soufflage
câblé.
K** Branchez à la borne K sur le module
économiseur de fils. K** Branchez à la borne K sur le module
économiseur de fils.
* Retirez le cavalier installé en usine uniquement pour les systèmes à deux transformateurs.
** Le module économiseur de fils THP9045A1023 est utilisé sur les systèmes de chauffage/refroidissement lorsque vous n’avez
que quatre fils sur le thermostat et qu’un cinquième fil commun est requis. Utilisez la borne K à la place des bornes Y et G sur les
systèmes conventionnels ou à thermopompe pour assurer le contrôle du ventilateur et du compresseur par un fil unique—le fil non
utilisé devient alors le fil commun. Voir les instructions du THP9045 pour plus d’informations.
C
K
RC
R
U1
U1
120 V c.a.
C
R
TRANSFORMATEUR
DU SYSTÈME
24
V c.a.
TRANSFORMATEUR
D'HUMIDIFICATEUR,
DÉSHUMIDIFICATEUR,
VENTILATION
THERMOSTAT
HUMIDIFICATEUR,
DÉSHUMIDIFICATEUR
OU VENTILATEUR
ÉLECTRIQUE
120 V c.a.
24
V c.a.
C
K
RC
R
U1
U1
120
V c.a.
24
V c.a.
C
R
TRANSFORMATEUR
DU SYSTÈME
THERMOSTAT
HUMIDIFICATEUR,
DÉSHUMIDIFICATEUR
OU VENTILATEUR NON
ÉLECTRIQUE
CAVALIER INSTALLÉ SUR
SITE ENTRE R ET U1
CONNEXION D’UN ÉTAGE DE CHAUFFAGE OU REFROIDISSEMENT
À U1
DÉSHUMIDIFICATION AVEC VENTILATEUR BASSE VITESSE
HUMIDIFICATEUR, DÉSHUMIDIFICATEUR OU VENTILATEUR NON
ÉLECTRIQUE
HUMIDIFICATEUR, DÉSHUMIDIFICATEUR OU VENTILATEUR
ÉLECTRIQUE
Câblez le relais universel du thermostat sur la vitesse de
ventilateur basse pour la commande de déshumidication sur
l’équipement. Le relais du thermostat peut être réglé sur nor-
malement ouvert ou normalement fermé dans la conguration
de l’installateur du thermostat.
1
Les bornes U1 sont des contacts secs normalement
ouverts lorsque le système est conguré pour un étage
de chauffage ou de refroidissement.
Un cavalier doit être installé si l’étage de chauffage ou
de refroidissement est alimenté par le transformateur
du système. N’installez PAS de cavalier si l’étage de
chauffage a son propre transformateur.
1
2
Contacts secs normalement ouverts
Contacts secs normalement fermés
TRANSFORMATEUR
DU SYSTÈME
1
C
K
RC
R
U1
U1
C
R
THERMOSTAT
DÉSHUMIDIFICATION
AVEC VENTILATEUR
BASSE VITESSE
CAVALIER INSTALLÉ SUR
SITE ENTRE R ET U11
OU
120
V c.a.
24
V c.a.
2
C
K
RC
R
U1
U1
C
R
THERMOSTAT
CHAUFFAGE ÉTAGE 3,
REFROIDISSEMENT ÉTAGE 3,
CHAUFFAGE SECOURS ÉTAGE 2
POUR THERMOPOMPES OU
CHAUFFAGE RAYONNANT
GÉOTHERMIQUE
1
120
V c.a.
24
V c.a.
TRANSFORMATEUR
DU SYSTÈME

5
Les options de configuration définissent le type de système que vous installez et les
préférences d’affichage.
1 Suivez les invites sur l’écran pour sélectionner les options appropriées.
Sur les écrans affichés, vous verrez les options permettant de définir les
points suivants :
1.6 L’application (résidentielle ou
commerciale).
1.7 Le nom du thermostat, qui vous
permettra de l’identifier si vous
installez plus d’un thermostat (pour
une application de CVCA à zones, par
exemple).
1.8 Le type de thermostat, programmable
ou non, en fonction de vos préférences.
1.9 L’échelle de température, Fahrenheit ou
Celsius.
1.10 Utiliser la température extérieure
REMARQUE : Choisissez WIRED/INTERNET
(Câblé/Capteur) si votre application nécessite
un capteur câblé, ou si elle utilisera Internet
pour obtenir les informations météo.
1.11 Le type de système de chauffage.
1.12 Pour toutes les options de l’installateur,
appuyez sur les boutons sou tpour
modifier l’option.
1.13 Appuyez sur Next (Suivant) pour passer au réglage suivant, et sur Done
(Terminé) une fois que la configuration est terminée.
APPLICATION
residential
M34150
THERMOSTAT TYPE
programmable
M35356
THERMOSTAT NAME
THERMOSTAT
M35357
TEMPERATURE SCALE
fahrenheit
M35359
HEATING SYSTEM
conv. forced air
Effectuer la configuration de l’installateur
USE OUTDOOR TEMP
wired / internet

6
1C/1CL (1 transformateur)
Rc Alimentation [1]
R [R + Rc reliés par cavalier]
W Relais chauffage
Y Contacteur compresseur
G Relais ventilateur
C Neutre 24Vca
S1 Capteur en option
Chauffage seulement
Rc Alimentation [1]
R [R + Rc reliés par cavalier]
W Relais chauffage
C Neutre 24Vca
S1 Capteur en option
Chauffage seulement (Série 20)
Rc [R + Rc reliés par cavalier]
R Borne « R » valve Série 20 [1]
W Borne « B » valve Série 20
Y Borne « W » Série 20
C Neutre 24Vca
S1 Capteur en option
2C/2CL (1 transformateur)
Y2 Relais climatisation 2
W2 Relais chauffage 2
Rc Alimentation [1]
R [R + Rc reliés par cavalier]
W Relais chauffage
Y Relais climatisation 1
G Relais ventilateur
C Neutre 24Vca
S1 Capteur en option
1C/1CL (2 transformateurs)
Rc Alimentation (climatisation) [1, 2]
R Alimentation (chauffage) [1, 2]
W Relais chauffage
Y Contacteur compresseur
G Relais ventilateur
C Neutre 24Vca [3]
S1 Capteur en option
Chauffage seulement avec ventilateur
Rc Alimentation [1]
R [R + Rc reliés par cavalier]
W Relais chauffage
G Relais ventilateur
C Neutre 24Vca [3]
S1 Capteur en option
Climatisation seulement
Rc Alimentation [1]
R [R + Rc reliés par cavalier]
Y Contacteur compresseur
G Relais ventilateur
C Neutre 24Vca
S1 Capteur en option
2C/2CL (2 transformateurs)
Y2 Relais climatisation 2
W2 Relais chauffage 2
Rc Alimentation (climatisation) [1, 2]
R Alimentation (chauffage) [1, 2]
W Relais chauffage 1
Y Relais climatisation 1
G Relais ventilateur
C Neutre 24Vca [3
S1 Capteur en option
Câblage
Voir [remarques] ci-dessous
[1] Alimentation. Fournir un moyen de disjoncter et une protection contre les surcharges
si nécessaire.
[2] Retirez le cavalier pour les installations à 2 transformateurs.
[3] La connexion commune doit parvenir du transformateur de refroidissement en cas d’installation à 2
transformateurs.
Table of contents
Languages:
Other Lutron Electronics Thermostat manuals

Lutron Electronics
Lutron Electronics PALLADIOM User manual

Lutron Electronics
Lutron Electronics L-HWLV2-WIFI User manual

Lutron Electronics
Lutron Electronics TouchPRO Wireless LR-HWLV-HVAC User manual

Lutron Electronics
Lutron Electronics LR-HVAC-230-S User manual

Lutron Electronics
Lutron Electronics TH8321WF1043 User manual

Lutron Electronics
Lutron Electronics LR-HVAC-230-S User manual