WARRANTY
All fiber optic transmission systems, products and accessories
manufactured by Liteway, Inc. and it’s subsidiaries are fully tested
prior to shipment and are warranted against defective materials
and workmanship for a period of five full years from the date of the
original shipment. Should a problem occur, a Return Material
Authorization Number (RMA) must be obtained from Liteway Inc.
at (516) 931-2800 and the item returned to Liteway, Inc. 166
Haverford Road, Hicksville, NY 11801, USA, prepaid. Liteway Inc.
will then, at its option repair or replace the defective item.
Liteway, Inc. maximum liability under this warranty is limited to the
cost of the defective item only. No contingent liabilities of any kind
are either assumed or implied.
Any items returned to Liteway, Inc. that have been misused,
abused, damaged, modified, connected or adjusted in any way
contrary to the instructions furnished by Liteway, Inc. or repaired
by unauthorized personnel will not be covered by this warranty.
Any non-warranty repairs required will be quoted at the current
rate for such services.
Important Notices
CAUTION ! AVOID DIRECT EXPOSURE TO BEAM.
All –5, -7, -8, and -9 Models use laser diodes. These solid-state
laser diodes are located in the optical ports of these units. Laser
diodes produce invisible radiation that may be harmful to human
eyes. Never look directly into the optical port of any fiber optic
unit designed to operate with single-mode optical fiber.
NOT FOR LIFE SUPPORT SYSTEMS
Liteway, Inc. does not authorize or warrant any of its products or
accessories for use in critical life support systems or applications
of any kind.
© Copyright 2017 Liteway, Inc. 134611 Rev C
OPERATING INSTRUCTIONS
Optical Protection Switch
OS-7321-x
The OS-7321 is an optical path protection switch, providing a self
healing network. This optic switch detects loss of optical power in the
primary optical path and automatically switches to the secondary
(backup) path. When the primary link is restored, the network path is
restored to the primary path. The optical protection switch can be
controlled via three methods; front panel manual switch, remote
control signal, or the automatic internal monitoring circuitry. The
switch also contains a transmitter splitter for creating the redundant
transmit path. Technical Specifications
Switching Time < 10 ms
Back Reflection < -50 dB
Insertion Loss < 1.5 dB
Cross-talk < -50 dB
Mechanical Life > 1 Million cycles
Switch sensitivity Adjustable -43 dBm to -29 dBm
Sensitivity Data rate DC to 3 Gb/s
Electrical Connector 6 pin removable terminal block
Temperature Range -20º to +70ºC
Operating Power Requirements 11-24 VAC/DC @150 mA, 110/220VAC
or -48 VDC (+/-2)
Physical Size (mm) 1 EIA Rack Unit (1U)
1.75”(44)L x 19”(482.6)W x 8.0”(203.2)D
Models, wavelength, connector
-3 = 850/1310nm Multimode ST/PC -4 = 850/1310nm Multimode SC/PC
-5 = 1310/1550nm Single-mode
SC/PC -7 = 1310/1550nm Single-mode FC/PC
Specifications are subject to change without prior notice.
!
Installation Instructions
Common applications for this device are optical routing, system
bypass, ring network restoration, and loop-back testing.
Channel A1
Fiber (Primary)
OS-7321
Channel B1 Fiber
(Secondary)
Manual Channel
Select
Power Detector
Controller Channel
Status
C1
C2
A2
B2
110-220VAC
The diagram below shows the typical application of the OS-7321.
OS-7321-5
Network
Termnial
Network
Termnial
Typical Bidirectional Optical Protection Application
OS-7321-5
Working Fiber Optic Pair
Protection Fiber Optic Pair
120/220
VAC
120/220
VAC
The OS-7321 switch will go in a secondary state under any of the
following conditions:
1) There is a loss of electrical power.
2) The front panel mode switch is put into secondary mode
3) The rear panel control signal is grounded & in auto mode.
134611 Rev C
Power Signal Terminal Block Connections
Pin Label Function
1 Ctl Control Signal ( Connect to ground to place
switch in bypass state ) when in auto mode.
2 Alm Alarm*
= Ground when primary or sec. signal is lost
= Open otherwise
3 Gnd Ground
4 +12V Power input +12 VDC
4 VDC
Rtn Power Input Return
6 -48V Power input -48 VDC
* The Alarm signal can be used with the ALM-1000 unit to provide an
audible alarm and dry contacts for remote station monitoring.
Indicator Lights
Indicator Lights when
Power Proper power is present
Alarm Alarm state, primary or secondary power level low.
Signal Primary Signal on primary channel is > level selected
Signal Secondary Signal on secondary channel > level selected.
Output Primary Output is connected to Primary > level selected.
Output Secondary Output is connected to Secondary > level selected
Front Panel Auto / Primary / Secondary Mode Selector
When in auto mode, the optical switch can be controlled by the rear
control signal or presence of power.
Optical Power (+/- 1.0 dBm) Level Switch Setting
Switch Level Switch Level Switch Level Switch Level
0 test 4 -35.0 8 -32.2 12 -31.0
1 -43.0 5 -34.0 9 -32.0 13 -30.3
2 -39.0 6 -33.0 10 -31.5 14 -30.0
3 -36.0 7 -32.5 11 -31.3 15 -29.8
Signal indicator will flash when signal power level is 0.5 dB < selected
level. Note for 850nm, table sensitivity levels are 3dB lower.

Other Luxlink Switch manuals

Luxlink RJSW-1012 User manual

Luxlink

Luxlink RJSW-1012 User manual

Luxlink OSM-5222-84 User manual

Luxlink

Luxlink OSM-5222-84 User manual

Luxlink OSM-6222-XY User manual

Luxlink

Luxlink OSM-6222-XY User manual

Luxlink RSW-3002 User manual

Luxlink

Luxlink RSW-3002 User manual

Popular Switch manuals by other brands

ADDER View DVI AV4DVI Installation & use

ADDER

ADDER View DVI AV4DVI Installation & use

USA SSC P3POE16-30 user manual

USA SSC

USA SSC P3POE16-30 user manual

TRENDnet TI-IG60 Quick installation guide

TRENDnet

TRENDnet TI-IG60 Quick installation guide

CHERUBINI wiDom Smart Dry Contact Switch 7 operating instructions

CHERUBINI

CHERUBINI wiDom Smart Dry Contact Switch 7 operating instructions

Kohler KBS Operation and installation

Kohler

Kohler KBS Operation and installation

Pepperl+Fuchs RocketLinx ICRL2-U-5RJ45-DIN manual

Pepperl+Fuchs

Pepperl+Fuchs RocketLinx ICRL2-U-5RJ45-DIN manual

Elko RFSA-62B manual

Elko

Elko RFSA-62B manual

Pepperl+Fuchs Vibracon LVL-A7 manual

Pepperl+Fuchs

Pepperl+Fuchs Vibracon LVL-A7 manual

Moen GEC8 Live owner's manual

Moen

Moen GEC8 Live owner's manual

HP StorageWorks 9100 - Extreme Data Storage... instructions

HP

HP StorageWorks 9100 - Extreme Data Storage... instructions

TRENDnet TPE-TG50ES user guide

TRENDnet

TRENDnet TPE-TG50ES user guide

Woodward DSS-2 installation guide

Woodward

Woodward DSS-2 installation guide

Moxa Technologies ToughNet TN-G4500 Series Quick installation guide

Moxa Technologies

Moxa Technologies ToughNet TN-G4500 Series Quick installation guide

Kathrein EXE 1581 Guide

Kathrein

Kathrein EXE 1581 Guide

Intermatic Grasslin GM40AV Series Installation & operating instructions

Intermatic

Intermatic Grasslin GM40AV Series Installation & operating instructions

ORiNG IGS-P9164 Series Quick installation guide

ORiNG

ORiNG IGS-P9164 Series Quick installation guide

NIVOFLOAT NL-100 Series user manual

NIVOFLOAT

NIVOFLOAT NL-100 Series user manual

Cisco SF500-24P quick start guide

Cisco

Cisco SF500-24P quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.