WARRANTY
All fiber optic transmission systems, products and accessories
manufactured by Liteway, Inc. and it’s subsidiaries are fully tested
prior to shipment and are warranted against defective materials
and workmanship for a period of five full years from the date of the
original shipment. Should a problem occur, a Return Material
Authorization Number (RMA) must be obtained from Liteway Inc.
at (516) 931-2800 and the item returned to Liteway, Inc. 166
Haverford Road, Hicksville, NY 11801, USA, prepaid. Liteway Inc.
will then, at its option repair or replace the defective item.
Liteway, Inc. maximum liability under this warranty is limited to the
cost of the defective item only. No contingent liabilities of any kind
are either assumed or implied.
Any items returned to Liteway, Inc. that have been misused,
abused, damaged, modified, connected or adjusted in any way
contrary to the instructions furnished by Liteway, Inc. or repaired
by unauthorized personnel will not be covered by this warranty.
Any non-warranty repairs required will be quoted at the current
rate for such services.
Important Notices
CAUTION ! AVOID DIRECT EXPOSURE TO BEAM.
All –5, -7, -8, and -9 versions may switch laser diodes. These laser
diodes are routed through the optical ports of the switch. Laser
diodes produce invisible radiation that may be harmful to human
eyes. Never look directly into the optical port of any fiber optic
unit designed to operate with single-mode optical fiber.
NOT FOR LIFE SUPPORT SYSTEMS
Liteway, Inc. does not authorize or warrant any of its products or
accessories for use in critical life support systems or applications
of any kind.
© Copyright 2017 Liteway, Inc. 135612 Rev E
OPERATING INSTRUCTIONS
Optical Bypass Switch with Monitors
Model OSM-5222-84
The OSM-5222-84 is a single-mode fiber optic switch that is used to
route optical signals. The optical path through the units is purely
optical. There is no optical to electrical to optical conversion and as a
result there is no electrical modulation bandwidth limit on the fiber
optic path. Under normal operation the optical switch routes optical
signals to and from local external devices. In event of a loss of
power, the unit automatically switches to a "bypass mode" as shown
on the optical wiring diagram.
Technical Specifications
Switching Time < 10 ms
Back Reflection < -50dB
Insertion Loss < 1.1 dB
Cross-talk < -50dB
Mechanical Life > 1 Million cycles
Electrical Connector Removable terminal block
Temperature Range -20º to +65ºC
Operating Power Requirements -20 to -60 VDC (Floating ground)
Physical Size (mm) OSM-5222 5.0”(127)L x 1” (25.4)H x 3.0”(7)D
Physical Size (mm) OSM-7222 19”(483)L x1.75” (44.5)W x 6.0”(152)D
Specifications are subject to change without prior notice.
"84" in the part number indicates the following"
8 = Fiber/Connector: Single-mode/LC
4 = Signal/Monitor Version: 70/30
Note that the OSM-5222-84 is intended for stand-alone or DIN rail
mounting with an optional DIN-1000 bracket.
!
Installation Instructions
The diagram below shows the optical wiring for the OSM-5222-84.
West (right)
West Mid
(left)
West (left)
West mid
(right)
East (right)
East Mid
(left)
East (left)
East mid
(right)
OSM-5222-84 Optical Wiring Diagram
Switch 2
Switch 1
All ports are viewed from the printed side of the rear panel
70% of
signal
30% of signal
30% of signal
70% of
signal
OPTICAL SIGNAL PATH
RED to GREEN = Power Applied to Switch
BLACK to GREEN = No Power Applied to Switch
Shown with no
power applied
(black)
With power
applied (blue)
Shown with no
power applied
(black)
With power
applied (blue)
135612 Rev E
Modes of Operation
With Operating Power Applied
East Mid (in) optical port is routed to East (out) optical
port. West (in) optical port is routed to West Mid (out)
optical port (30% of signal)
West Mid (in) optical port is routed to West (out) optical
port. East (in) optical port is routed to East Mid (out)
optical port (30% of signal)
No Operating Power Applied
East (in) optical port is routed to West (out) optical port
(70% of signal) and East Mid (out) optical port (30% of
signal)
West (in) optical port is routed to East (out) optical port
(70% of signal) and West Mid (out) optical port (30% of
signal)
Power Signal Terminal Block Connections
Pin Label Function
1 Pwr+ Power +
2 Pwr- Power –
3 GND Housing ground
4, 5 -- Not used
Note that the power pins are isolated from the housing.
Indicator Light
Indicator Lights When
Power Proper power is present

Other Luxlink Switch manuals

Luxlink RJSW-1012 User manual

Luxlink

Luxlink RJSW-1012 User manual

Luxlink OSM-6222-XY User manual

Luxlink

Luxlink OSM-6222-XY User manual

Luxlink RSW-3002 User manual

Luxlink

Luxlink RSW-3002 User manual

Luxlink OS-7321 Series User manual

Luxlink

Luxlink OS-7321 Series User manual

Popular Switch manuals by other brands

HP ProCurve 5406zl Installation and getting started guide

HP

HP ProCurve 5406zl Installation and getting started guide

Audioplex SR-12 installation manual

Audioplex

Audioplex SR-12 installation manual

NEO NEXUS SWITCH 24 user manual

NEO

NEO NEXUS SWITCH 24 user manual

Honeywell S437A Product data

Honeywell

Honeywell S437A Product data

Targus USB-C user guide

Targus

Targus USB-C user guide

ATEN Bi-tronics Auto user manual

ATEN

ATEN Bi-tronics Auto user manual

Cerio PoE Series user guide

Cerio

Cerio PoE Series user guide

Vega VEGAVIB 62 operating instructions

Vega

Vega VEGAVIB 62 operating instructions

NTI SM-4X4-4K18GB-LC operating instructions

NTI

NTI SM-4X4-4K18GB-LC operating instructions

Sony MVS-8000 user guide

Sony

Sony MVS-8000 user guide

NETGEAR GSM7228PS-100NAS Hardware installation guide

NETGEAR

NETGEAR GSM7228PS-100NAS Hardware installation guide

Luxart LX944600 quick start guide

Luxart

Luxart LX944600 quick start guide

ICP DAS USA NS-208A user manual

ICP DAS USA

ICP DAS USA NS-208A user manual

Digitus professional DN-80111 manual

Digitus professional

Digitus professional DN-80111 manual

ZKTeco AP100 Series quick start guide

ZKTeco

ZKTeco AP100 Series quick start guide

showhome ZW661 manual

showhome

showhome ZW661 manual

Russound AB-3.2 datasheet

Russound

Russound AB-3.2 datasheet

Fish Tuning DSP5 Using

Fish Tuning

Fish Tuning DSP5 Using

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.