Luxul XWS-2210 User manual

READ ME FIRST
Wireless Controller System
with High-Power 300N
Access Points
XWS-2210
System Includes
One: XWC-1000 Wireless Controller
One: Rack Mount Kit
Two: XAP-1210 Access Points
Two: PoE Injectors
One: Power Cord
QUICK INSTALL GUIDE

READ ME FIRST - AP COMPATIBILITY
The Access Points included in this XWS-2210 Wireless Controller Kit are ready for set-
up. If you don’t plan to use the Wireless Controller to manage any older or previous-
ly-installed APs, you can skip to the next section titled, “Before You Begin Installation”.
If you are using separately-purchased Luxul APs or installing a
Wireless Controller into an existing Luxul deployment, you may
need to manually upgrade the AP firmware before installing
the Wireless Controller. Luxul APs running firmware version 5
or later are Controller-compatible and can be used with the
Controller as-is. When purchasing Luxul APs for use with the
Wireless Controller, look for an orange “Version 5 Firmware”
sticker on the box to avoid the manual upgrade process.
XAccess Point Compatibility: The XWC-1000 Wireless Controller is compatible with
the following Luxul AP models: XAP-310, XAP-1210, XAP-1230, XAP-1500.
Access Point Upgrade Instructions:
cCaution: It is not possible to downgrade the AP from firmware version 5,
so upgrade only if you are certain you don’t want to go back.
1. Make sure the XWC-1000 Wireless Controller is disconnected from the network
or powered off during the AP upgrade process.
2. Use your computer to download the firmware file for your AP from
luxul.com/firmware-updates
3. Open the APs web interface by entering the IP address of the AP in your
computer’s browser and select Administration >> Firmware Update
4. Click the Browse button and select the firmware file you downloaded,
then click Open
5. Click the Upgrade button. You should now see a status indicator to let
you know the firmware upgrade is in progress.
6. Once the power LED starts blinking, close the browser used to access the
APs web interface.
7. Once the power LED stops blinking, open a new browser window and re-enter the
IP address of the AP. Restore the APs factory default settings by using the web
interface or the Factory Default button on the AP. The AP is compatible with the
XWC-1000 Wireless Controller only after it is restored to factory default condition.
8. The AP is now compatible with the Wireless Controller. Power down the AP until
the Controller Setup Wizard instructs you to apply power to the AP.
Repeat this process for any other APs which require a manual firmware upgrade
and that you wish to manage with the XWC-1000 Wireless Controller.
C
O
N
T
R
O
L
L
E
R
R
E
A
D
Y
•
C
O
N
T
R
O
L
L
E
R
R
E
A
D
Y
•
VERSION
5
FIRMWARE

BEFORE YOU BEGIN INSTALLATION
XAccess Point Firmware: If you are using APs other than those included in this kit,
please refer to READ ME FIRST - AP COMPATIBILITY on the previous page.
XController Setup Sequence: Be sure to setup the XWC-1000 Wireless Controller
BEFORE powering up the APs. Once logged into the Wireless Controller, the Setup
Wizard will prompt you when it is time to add the APs to the network. A DHCP
server is required on the network.
XAccessibility: Once an Access Point is controlled by the XWC-1000 Wireless
Controller, the web interface on the AP is no longer enabled. Conversely, if an AP
confi guration is managed via its web interface, communication with the XWC-1000
Wireless Controller will be disabled. To change an AP from Controller-managed to
standalone (or the reverse), restore the AP to Factory Default.
XFirmware Updates: The XWC-1000 Wireless Controller automatically checks for
fi rmware updates of Controller-compatible APs and the Wireless Controller itself,
but requires Internet access to do so. The Wireless Controller will still operate
without Internet access, but fi rmware updates will not be available.
Physical Installation
XConnecting Devices: The XWC-1000 Wireless Controller simply connects to the
network. The XAP-1210 APs connect to the network via the included PoE Injectors.
Wireless Controller
AP
AP
LAN
PoE
Injectors
Injectors
Injectors
InjectorsInjectors
PoEPoE
InjectorsInjectors
PoEPoE
InjectorsInjectors
PoEPoE

XAccess Point Placement: Place APs to ensure adequate coverage, but not so far apart
that there is no signal overlap. You may have to experiment with AP placement to
optimize the roaming experience. The APs should overlap enough that the client
device has a good connection to the AP to which it is currently attached, but also
sees the next-nearest AP.
nNote: Consider using Ekahau HeatMapper to assist with this process, available
from www.ekahau.com. Luxul also offers an informative “How-To” video on
HeatMapper at luxul.com/how-to-videos.

WIRELESS CONTROLLER SYSTEM KIT SETUP
1. Use an Ethernet cable to plug the XWC-1000 Wireless Controller into the network.
Do not connect any APs to the network yet.
nNote: Be sure a DHCP server is present on the network and that all Luxul APs and
the XWC-1000 Wireless Controller will share the same subnet. If your network
uses a 192.168.0.X IP address scheme, you are ready to start the setup process. If
not, you will need to manually change the IP address of your computer to be able
to confi gure the XWC-1000 Wireless Controller so that it is on the same subnet as
your network. For help setting the IP address of your particular operating system,
visit luxul.com/ip-addressing.
2. To access the Setup Wizard, open your web browser and enter the Wireless
Controller’s default 192.168.0.19 IP address in the address fi eld. Log in to the Wireless
Controller using the default user name and password:
Default IP: 192.168.0.19
Username: admin
Password: admin
nNote: If there is another device on the network already using the 192.168.0.19
address, you’ll need to either temporarily disconnect or reconfi gure that other
device, or manually confi gure the Wireless Controller with a different address
on a separate isolated network.
3. Follow the built-in Setup Wizard in the Wireless Controller. The Wizard will direct
you to power the APs on at the appropriate time and walk you through completing
the setup.
tSmart Tip: For more information on setup and confi guration best practices,
visit luxul.com/smart-tips.
RESETTING THE CONTROLLER
XReset/Reboot: Use a paperclip to press and release the reset button on the front
panel of the Controller to force it to reboot. The LEDs will go dark once the button is
released, then blink slowly while the controller boots.
XRestore Factory Defaults: To restore the controller to Factory Default
confi guration, press and hold the reset button for at least 5 seconds. The System
LED will blink quickly to indicate that the Controller is returning to Factory Default
confi guration, go dark for a few seconds, then blink slowly while the
controller reboots.
XNormal Operation: When the controller is operating normally, the System LED will
blink like a heartbeat, i.e. blink-blink-dark.

LEGAL AND REGULATORY INFORMATION
No part of this publication may be modified or adapted in any way, for any purposes without permission in
writing from Luxul. The material in this manual is subject to change without notice. Luxul reserves the right to
make changes to any product to improve reliability, function, or design. No license is granted, either expressly
or by implication or otherwise under any Luxul intellectual property rights. An implied license only exists for
equipment, circuits and subsystems contained in this or any Luxul product.
FCC ID: W59XAP1210
IC: 8584A-XAP1210
Regulatory Compliance
The device complies with internationally recognized standards covering human exposure to electromagnetic
fields from radio devices. This equipment also complies with FCC radiation exposure set forth for an uncon-
trolled environment. In order to avoid the possibility of exceeding the FCC radio frequency exposure limits,
human proximity to the antenna shall not be less than 20 cm (8 inches) during normal operation.
Unauthorized antennas, modifications, or attachments could cause damage and may violate regulatory
approvals. Any changes or modifications not expressly approved by the party responsible for compliance
could void the authority to operate the equipment.
The equipment version marketed in the U.S. is restricted to usage of channels 1-11 only.
Health and Safety Recommendations
XWarnings for the use of Wireless Devices: Please observe all warning notices with regard to the usage of
wireless devices
XPotentially Hazardous Atmospheres: You are reminded of the need to observe restrictions on the use of
radio devices in fuel depots, chemical plants etc. and areas where the air contains chemicals or particles
(such as grain, dust, or metal powders).
XSafety in Hospitals: Wireless devices transmit radio frequency energy and may affect medical electrical
equipment. When installed adjacent to other equipment, it is advised to verify that the adjacent
equipment is not adversely affected.
RF Exposure Guidelines
XSafety Information: The device complies with internationally recognized standards covering human
exposure to electromagnetic fields from radio devices.
XWarning, Exposure to Radio Frequency (RF) Radiation: The radiated output of this device is below the
FCC radio frequency exposure limits. Nevertheless, the device should be used in such a manner that the
potential for human contact during normal operation is minimized.
XThe end user must avoid any extended human RF exposure directly in front of the device, up to a distance
of 20cm, when unit is on.
XWhen servicing the equipment and selecting a location for the antennas, it is important to note that a
minimum distance of 20cm is required between personnel and the device or antenna to comply with the
radio frequency exposure limit.
XThe antenna used for this transmitter must be installed to provide a separation distance of at least
20cm from all persons and must not be co-located or operating in conjunction with any other
antenna or transmitter.
The following safety precautions should be observed:
XDo not touch or move the antenna while the unit is transmitting or receiving.
XDo not hold any component containing the radio such that the antenna is very close or touching any
exposed parts of the body, especially the face or eyes, while transmitting.
XDo not operate the radio or attempt to transmit data unless the antenna is connected; this behavior may
cause damage to the radio.

FCC Statement—Wireless FCC 2.4GHz & 5GHz 802.11abgn
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)
This device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to
Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful inter-
ference in a residential installation. This equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined
by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the
following measures:
XReorient or relocate the receiving antenna.
XIncrease the separation between the equipment and receiver.
XConnect the equipment into an outlet on a circuit different from that to which the receiver is connected.
XConsult the dealer or an experienced radio/TV technician for help.
FCC Caution: Any changes or modifi cations not expressly approved by the party responsible for compliance
could void the user’s authority to operate this equipment.
This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment.
This equipment should be installed and operated with minimum distance 20cm between the radiator
and your body.
Hereby, Luxul, 14203 Minuteman Drive, Suite 201, Draper, Utah, 84020, declares that this Luxul
XAP-1210 is in compliance with the essential requirements and other relevant provisions of
Directive 1995/5/EC.
For a copy of this report send a self addressed stamped envelope to:
Luxul CE, 14203 Minuteman Drive, Suite 201, Draper, Utah, 84020.
Industry Canada (RSS-Gen Issue 4)
This device complies with Industry Canada’s licence-exempt RSSs. Operation is subject to the following
two conditions: (1) This device may not cause interference; and (2) This device must accept any interference,
including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de
licence. L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de
brouillage; (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage
est susceptible d’en compromettre le fonctionnement.
The device meets the exemption from the routine evaluation limits in section 2.5 of RSS 102 and compliance
with RSS-102 RF exposure, users can obtain Canadian information on RF exposure and compliance.
Le dispositif rencontre l’exemption des limites courantes d’évaluation dans la section 2.5 de RSS 102 et la
conformité à l’exposition de RSS-102 rf, utilisateurs peut obtenir l’information canadienne sur l’exposition et la
conformité de rf.
This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This
equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator
and your body.
Cet émetteur ne doit pas être Co-placé ou ne fonctionnant en même temps qu’aucune autre antenne ou
émetteur. Cet équipement devrait être installé et actionné avec une distance minimum de 20 centimètres
entre le radiateur et votre corps.
CAN ICES-3(B)/NMB-3(B)

READ ME FIRST
© 2015 Luxul. All Rights Reserved. LUX-QIG-XWS-2210 05211509
Sales
P: 801-822-5450
Technical Support
P: 801-822-5450 Option 3
Table of contents
Other Luxul Controllers manuals