INSTALLATION OF THE TOUCH SCREEN
01. Main characteristics
• Touch screen (4 inches)
• Interface via internet. WiFi 2.4 GHz (not 5.0 GHz)
• Wall mountable with power supply 85-265V (50-60)Hz
• Can be placed on the table with supplied bracket, and mini USB power supply (5V).
• Battery operation (only for settings)
• RF Communication with other devices
• Multiple heating device control.
• SD Card update
• Intuitive menus for device management
! Charge the Touch E3 for at least one hour before pairing the devices
already mounted.
02. Available devices for connecting to Touch E3 (For example: Yali Digital,
Parada, Ramo, Epok, Tamari, Tinos, Paros. For Hydronic versions, see separate manual)
• Up to 50 rooms (zones) with one master radiator in each room.
• Up to 50 slave radiators to be distributed among the masters.
Examples: a) 50 zones with 1 master and 1 slave in each, total 100 radiators
b) 1 zone with 1 master and 50 slaves, total 51 radiators.
It is recommended to limit the number of slaves to 10 in one zone.
FOR
THE INSTALLER
UK
01. Main characteristics

P16MI417 - A06- 03/18 3|
FOR
THE INSTALLER UK
03. Wall mounting
• Connect the power supply as described below. e electrical installation
must comply with local or national regulations. e product should be
connected by a suitable and qualied electrician.
ENVIRONMENTAL CONDITIONS:
- Operating temp., connected
-Operating temp., battery
- Shipping and storage temp.
-30°C to +40*C (Display might not be fully functional at
temperatures below 0°C)
-0°C to +40°C
-30°C to +50°C
SETTING TEMPERATURE RANGE:
- Comfort mode
- Reduced mode
- Frost protection mode
+5.5°C to +30°C, may be lower than the reduced mode temperature
(overrules this restriction on radiator).
+5°C to +19°C, may be higher than Comfort mode temperature
(overrules this restriction on radiator).
+5°C to +10°C
ELECTRICAL INSULATION: Class II
ELECTRICAL PROTECTION: IP 30
RADIO FREQUENCY:
- Range outside
- Range indoor (typical)
868 MHz, <10mW
200 m
Around 15 m
WIFI FREQUENCY: 2.4 GHz (not 5.0 GHz)
SOFTWARE VERSION Can be found at the bottom of the Main menu: xx.xx
Can be found at the bottom right of the Wi menu: xxxx xx.xx
POWER SUPPLY & 85-265V 50-60 Hz
SD CARD 8 GB (FAT)
CE DIRECTIVES:
Your product has been designed
in conformity with the European
Directives.
LV Directive 2006/95/EC
EMC Directive 2004/108/EC
RED Directive 2014/53/EU
RoHS 2011/65/EU
POWER SUPPLY 85-265V, 50/60 HZ
NOT TO BE USED!

| 4 P16MI417 - A06- 03/18
FOR
THE INSTALLER
UK
• Screw the power supply on to the wall.
NOTE: e tab must be located at the top.
• Put the switch into the ON position by using a small pin
• Connect the mini USB cable and charger to the Touch E3.
• Mount the Touch E3 onto the bracket by sliding it down until it stops.
• Put the switch into the ON position by using a small pin
• e Touch E3 is now ready for use.
• Mount the Touch E3 on the power supply and slide it down until it stops.
• e Touch E3 is now ready for use.
04. Table installation
60 MM
ON / OFF
ON / OFF
CABLE

P16MI417 - A06- 03/18 5|
FOR
THE INSTALLER UK
05. General pictograms
SETTING LANGUAGE, TIME AND DATE
01. Press ”Main menu” button A
02. Press ”Set language” button D
• e ag of the current language is displayed.
03. Press ”User settings” button F
• Set the hour and the date. When auto is selected the time and date will be set
via the internet server,you also may select a time zone according to your region. Auto
summer/winter time can be selected from the menu.
to return to the previous screen
the buttons with a red dot require a long press
MAIN MENU
BUTTON
START SCREEN
SET LANGUAGE
USER SETTINGS
PARAMETER SETTINGS
AB
MAIN MENU
C
F
D
G
E
H I
to return to the ”Start screen”

| 6 P16MI417 - A06- 03/18
FOR
THE INSTALLER
UK
CREATE HOUSE
01. Press ”Main menu” button A
02. Press the ”Parameter settings” button I (long press)
03. Press the ”House creation” button
• Create all the rooms (or zones)
a Current room name
bTo change the current room name
c To add a room
dTo delete the current room
e Room selection
PAIRING RADIATORS
01. Press ”Main menu” button A
02. Press the ”Parameter setting” button I (long press)
• >> Select radio pairing
• Choose device, press ”Heating”.
• Select room
• Device (Radiator or Remote Control) to measure the temperature
must be paired rst in this zone!
• Press ”Green check” button to conrm
a
b
c
e e
d
RADIO PAIRING
ROOM MENU

P16MI417 - A06- 03/18 7|
FOR
THE INSTALLER UK
• Start the pairing by pressing ”radio pairing” button f
• Follow the instruction on the screen (depending on the type of device) .
• Repeat the steps for all devices, starting at >> Select radio pairing
03. Put the device (radiator or remote control) in pairing mode.
• See device leaet or manual
EXAMPLE: YALI DIGITAL /P/R
Press and hold the “OK” key for 5 seconds
rFi: Wireless Radio initialization (pairing)
Press ”OK” to enter this initialization sequence.
Select with ”+”or ”-”the radio communication type and validate by pressing ”OK”:
• rF.un: unidirectional communication, the digital thermostat only receives orders
from an LVI RF central programmer.
• rF.bi: bidirectional communication with an LVI Touch E3. e digital thermostat
communicates state and power consumptions to the LVI Touch E3.
en the backlight will switch o and the digits will cycle showing that the digital
thermostat is waiting for a radio link signal from a Central programmer or LVI
Touch E3 to be received (press ””to cancel radio initialization). When the radio
link signal is received, pairing is saved, then it will return to Auto mode.
RADIO PAIRING
BUTTON
f

| 8 P16MI417 - A06- 03/18
FOR
THE INSTALLER
UK
When you have completed the pairing of all devices and
each device is installed in its final location, check that
communication is established between each device and
the Central Unit.
Before checking, install the Central Unit in its final
location. Checking is undertaken by adjusting the heating
mode or the set point on the Central Unit and confirming
that that the adjustment instruction has been received by
the Thermostat and the Receiver.

P16MI417 - A06- 03/18 9|
FOR
THE INSTALLER
UK
04. Installation types (Type 1)
TOUCH E3
MASTER
SLAVE 1
SLAVE 2

| 10 P16MI417 - A06- 03/18
05. Installation types (Type 2)
FOR
THE INSTALLER
UK
TOUCH E3
SLAVE 2
SLAVE 1
(LVI RADIATOR)
(LVI RADIATOR)
MASTER
Other manuals for Touch E3
2
Table of contents
Languages:
Popular Touch Panel manuals by other brands

IBASE Technology
IBASE Technology ASTUT-152-RE1S user manual

YASKAWA
YASKAWA TP 610C manual

B&R
B&R Power Panel C Series user manual

Beijer Electronics
Beijer Electronics X2 control Hardware and installation manual

AXIOMTEK
AXIOMTEK GOT321W-521 user manual

TRIDONIC.ATCO
TRIDONIC.ATCO x-touchBOX Operation manual