manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. M-system
  6. •
  7. I/O System
  8. •
  9. M-system R3-RS8B User manual

M-system R3-RS8B User manual

R3-RS8B
P. 1 / 3EM-8341
BEFORE USE ....
Thank you for choosing M-System. Before use, please check
the contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.
n PACKAGE INCLUDES:
RTD input module....................................................... (1)
n MODEL NO.
Check that model No. described on the specification label is
exactly what you ordered.
n INSTRUCTION MANUAL
This manual describes necessary points of caution when you
use this product, including installation, connection and basic
maintenance procedures.
POINTS OF CAUTION
n HOT INSERTION/REMOVAL OF MODULES
Removing or replacing modules does not affect other modules
on the same backplane. It is possible to replace them without
removing the power supply. However, replacing multiple
modules at once may greatly change line voltage levels. We
recommend that you replace them one by one.
n ENVIRONMENT
• Indoor use
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -10 to +55°C
(14 to 131°F) with relative humidity within 30 to 90% RH in
order to ensure adequate life span and operation.
n WIRING
• Do not install cables (power supply, input and output) close
to noise sources (relay drive cable, high frequency line, etc.).
• Do not bind these cables together with those in which noises
are present. Do not install them in the same duct.
n AND ....
• The unit is designed to function as soon as power is supplied,
however, a warm up for 10 minutes is required for satisfying
complete performance described in the data sheet.
INSTALLATION
Use the Installation Base (model: R3-BSx).
RTD INPUT MODULE
(8 points, isolated) MODEL R3-RS8B
INSTRUCTION MANUAL
R3-RS8B
P. 2 / 3EM-8341
COMPONENT IDENTIFICATION
nSIDE DIP SW
•RTD Type: SW1, SW2 (selectable per 4 channels)
SW2SW1
ON
1
2
3
4
5
6
7
8
ON
ON
1
2
3
4
5
6
7
8
SW3
1
2
3
4
5
19
20
21
22
15
16
17
18
23
24
25
26
27
28
6
7
8
9
10
11
12
13
14
1
2
3
4
FRONT VIEW
ERR LED
RUN LED
SIDE VIEW
Input 1-4 (SW1)
or
Input 5-8 (SW2)
RTD
Conv.Rate
Temp. Unit
Burnout
nn
INPUT 1 through INPUT 4 (SW1)
INPUT 5 through INPUT 8 (SW2) RTD
1 2 3 4
OFF OFF OFF OFF Pt 100 (*)
(JIS ’97, IEC)
ON OFF OFF OFF Pt 100
(JIS ’89)
OFF ON OFF OFF JPt 100
TERMINAL CONNECTIONS
Connect the unit as in the diagram below.
n DIMENSIONS mm (inch)
TERMINAL
COVER
5
19
20
21
22
15
16
17
18
23
24
25
26
27
28
6
7
8
9
10
11
12
13
14
1
2
3
4
130 (5.12)
27.5 (1.08) 109 (4.29)
POSITIONING
GUIDE
28–M3
SCREW
6.2
(.24)
nSTATUS INDICATOR LED
RUN indicator: Bi-color (red/green) LED;
Red when the bus A operates normally;
Green when the bus B operates normally;
Amber when both buses operate normally.
ERR indicator: Bi-color (red/green) LED;
Red with burnout;
Green in normal operating conditions.
•Burnout: SW3
•Temperature Unit: SW3
•Conversion Rate: SW3
SW3-1 BURNOUT
OFF Upscale (*)
ON Downscale
SW3-2 TEMP. UNIT
OFF °C (*)
ON °F
SW CONV. RATE
160 80 40 20
SW3-3 OFF(*) ON OFF ON
SW3-4 OFF(*) OFF ON ON
(*) Factory setting
R3-RS8B
P. 3 / 3EM-8341
n CONNECTION DIAGRAM
WIRING INSTRUCTIONS
nSOLDERLESS TERMINAL mm (inch)
Refer to the drawing below for recommended ring tongue
terminal size. Spade tongue type is also applicable. Solder-
less terminals with insulation sleeve do not fit. Applicable
wire size: 0.3 – 0.5 mm2
3.2 (.13) dia.
4 min.
(.16)
12 (.47) max.
6 max.
(.24)
3 (.12) max.
INPUT 1
1
2
A
B
B
RTD
3
INPUT 2
4
5
A
B
B
RTD
6
INPUT 3
7
8
A
B
B
RTD
9
INPUT 4
10
11
A
B
B
RTD
12
INPUT 5
15
16
A
B
B
RTD
17
INPUT 6
18
19
A
B
B
RTD
20
INPUT 7
21
22
A
B
B
RTD
23
INPUT 8
24
25
A
B
B
RTD
26
BUS CONNECTOR
INTERNAL
POWER
BUS A
BUS B*
*For dual redundant communication.
• Unused Input Channels
Close across the unused input terminals with a resistor as
shown below and set the DIP switch for an RTD.
The resistance value must match the RTD type (100Ω for
Pt 100).
Unused channels left open are equal to the burnout, which
turns the red ERR LED on and sets a burnout ag at the
PLC or the host device.
Unused channels can be specied and set so on the PC
Configurator Software (model: R3CON) without needing to
connect resistors at the field terminals.
1
2
INPUT 1
4
5
INPUT 2
7
8
INPUT 3
10
11
INPUT 4
3 6 9
12
15
16
INPUT 5
17
18
19
INPUT 6
20
21
22
INPUT 7
23
24
25
INPUT 8
26
M-SYSTEM WARRANTY
M-System warrants such new M-System product which it manufactures to be free from defects in materials and workmanship during the 36-month period following the date that such
product was originally purchased if such product has been used under normal operating conditions and properly maintained, M-System’s sole liability, and purchaser’s exclusive
remedies, under this warranty are, at M-System’s option, the repair, replacement or refund of the purchase price of any M-System product which is defective under the terms of this
warranty. To submit a claim under this warranty, the purchaser must return, at its expense, the defective M-System product to the below address together with a copy of its original
sales invoice.
THIS IS THE ONLY WARRANTY APPLICABLE TO M-SYSTEM PRODUCT AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. M-SYSTEM SHALL HAVE NO LIABILITY FOR CONSEQUENTIAL, INCIDENTAL OR
SPECIAL DAMAGES OF ANY KIND WHATSOEVER.
M-System Co., Ltd., 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN, Phone: (06) 6659-8201, Fax: (06) 6659-8510, E-mail: info@m-system.co.jp

Other M-system I/O System manuals

M-system R7ML-YS2-R User manual

M-system

M-system R7ML-YS2-R User manual

M-system R7M-EA8/UL User manual

M-system

M-system R7M-EA8/UL User manual

M-system R30SV4 User manual

M-system

M-system R30SV4 User manual

M-system R7 Series User manual

M-system

M-system R7 Series User manual

M-system M8BS1-16U0 User manual

M-system

M-system M8BS1-16U0 User manual

M-system R7E-EC8A User manual

M-system

M-system R7E-EC8A User manual

M-system R3-SV8N User manual

M-system

M-system R3-SV8N User manual

M-system M8BS2-042 User manual

M-system

M-system M8BS2-042 User manual

M-system R8-YVT4N User manual

M-system

M-system R8-YVT4N User manual

M-system R7ML-TS4 User manual

M-system

M-system R7ML-TS4 User manual

M-system R7D-RS4 User manual

M-system

M-system R7D-RS4 User manual

M-system R7ML-SV4 User manual

M-system

M-system R7ML-SV4 User manual

M-system R8-SS4NJ User manual

M-system

M-system R8-SS4NJ User manual

M-system R80 Series User manual

M-system

M-system R80 Series User manual

M-system R7D-TS4 User manual

M-system

M-system R7D-TS4 User manual

M-system R7F4DC-DAC16D-H User manual

M-system

M-system R7F4DC-DAC16D-H User manual

M-system 15BX-4 User manual

M-system

M-system 15BX-4 User manual

M-system R7M-DA16-R User manual

M-system

M-system R7M-DA16-R User manual

M-system R3-SV4 User manual

M-system

M-system R3-SV4 User manual

M-system R7G4HEIP-6-DC16A User manual

M-system

M-system R7G4HEIP-6-DC16A User manual

M-system M5XPHS User manual

M-system

M-system M5XPHS User manual

M-system R30SVF4 User manual

M-system

M-system R30SVF4 User manual

M-system R8-SS4N User manual

M-system

M-system R8-SS4N User manual

M-system R1M-P4 User manual

M-system

M-system R1M-P4 User manual

Popular I/O System manuals by other brands

MG R7F4DH-1-DAC16B instruction manual

MG

MG R7F4DH-1-DAC16B instruction manual

WAGO I/O-SYSTEM 750 510 376 07 quick start

WAGO

WAGO I/O-SYSTEM 750 510 376 07 quick start

QTS AN-X2-MOD-MON user manual

QTS

QTS AN-X2-MOD-MON user manual

ICP DAS USA ET-8KP4-MTCP quick start

ICP DAS USA

ICP DAS USA ET-8KP4-MTCP quick start

ELPRO 905U-L installation manual

ELPRO

ELPRO 905U-L installation manual

Siemens 7XV5673 Device manual

Siemens

Siemens 7XV5673 Device manual

Sony LKRI-005 operating instructions

Sony

Sony LKRI-005 operating instructions

YASKAWA AI-14B user manual

YASKAWA

YASKAWA AI-14B user manual

NI 9206 Getting started guide

NI

NI 9206 Getting started guide

Allen-Bradley C Series installation instructions

Allen-Bradley

Allen-Bradley C Series installation instructions

Grundfos IO 241 Installation and operating instructions

Grundfos

Grundfos IO 241 Installation and operating instructions

Allen-Bradley 1746-INT4 quick start

Allen-Bradley

Allen-Bradley 1746-INT4 quick start

Grenton DIGITAL IN Z-Wave INP-038-Z-04 manual

Grenton

Grenton DIGITAL IN Z-Wave INP-038-Z-04 manual

CARLO GAVAZZI SH2RE1A424 instruction manual

CARLO GAVAZZI

CARLO GAVAZZI SH2RE1A424 instruction manual

WAGO WAGO-I/O-SYSTEM 750 Series manual

WAGO

WAGO WAGO-I/O-SYSTEM 750 Series manual

National Instruments 9237 CALIBRATION PROCEDURE

National Instruments

National Instruments 9237 CALIBRATION PROCEDURE

SIGMA TEK DI 080 instruction manual

SIGMA TEK

SIGMA TEK DI 080 instruction manual

Siemens SIMATIC ET 200SP manual

Siemens

Siemens SIMATIC ET 200SP manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.