manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. M-system
  6. •
  7. Network Hardware
  8. •
  9. M-system M8BS2-162 User manual

M-system M8BS2-162 User manual

M8BS2-162
P. 1 / 3EM-5495-2 Rev.2
BEFORE USE ....
Thank you for choosing M-System. Before use, check the
package you received as below.
If you have any problems or questions with the product,
please contact M-System's Sales Office or representatives.
■ PACKAGE INCLUDES:
Installation base.......................................................(1)
■MODEL NO.
Confirm that the model number described on the product is
exactly what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when you
use this product, including installation, connection and basic
maintenance procedures.
POINTS OF CAUTION
■ CONFORMITY WITH EC DIRECTIVES
• This equipment is suitable for use in a Pollution Degree 
2 environment and in Installation Category II, with the
maximum operating voltage 300V.
Basic insulation is maintained between the input and output.
Prior to installation, check that the insulation class of this 
unit satisfies the system requirements.
• The equipment must be mounted inside a panel.
• The  equipment  must be installed such that  appropriate 
clearance and creepage distances are maintained to conform
to CE requirements. Failure to observe these requirements
may invalidate the CE conformity.
■ POWER INPUT RATINGS
•  Power  input  ratings  are  specied  by  the  model  number 
suffix code. Check the power input voltage for the unit on
the specification label.
AC power: 100 – 240V AC rating: 85 – 264V, 47 – 63 Hz,
130VA min.
DC power:  24 V DC rating: 24V ±10%, 2,5A min.
■ ENVIRONMENT
• Indoor use
• When  heavy  dust  or  metal  particles  are  present  in  the 
air, install the installation base inside proper housing and
ventilate it.
• Do not install the base where it is subjected to continuous 
vibration.  Do not apply physical impact to the unit.
• Environmental temperature must be within 0 to 55°C or 32 
to 131°F (0 to 50°C or 32 to 122°F for AC power) with relative 
humidity within 30 to 90% RH (30 to 85% RH for AC Power)  
in order to ensure adequate life span and operation.
•  Be  sure  that  the  ventilation  slits  are  not  covered  with 
cables, etc.
■ WIRING
• Do not install cables (power supply, input and output) close 
to noise sources (relay drive cable, high frequency line, etc.).
• Do not bind these cables together with those in which noises 
are present.  Do not install them in the same duct.
■ AND ....
• The unit is designed to function as soon as power is supplied, 
however, a warm up for 10 minutes is required for satisfying
complete performance described in the data sheet.
COMPONENT IDENTIFICATION
■ REAR VIEW
INSTALLATION BASE
(for Network interface) MODEL
M8BS2-162
INSTRUCTION MANUAL
MOUNTING REQUIREMENTS mm (inch)
Specifications
460 (18.11)
4–M5 SCREW
50 (1.97)
M8BS2-162
P. 2 / 3EM-5495-2 Rev.2
TERMINAL CONNECTIONS
Connect the unit referring the drawings below and the connection diagrams in the following page.
■EXTERNAL DIMENSIONS mm (inch)
• M8BS2-162-M2
12345678 9
10 11 12 13 14 15 16
CH1 CH8 CH9 CH16
+–+–+–+–+–+–+–+–
+–+–+–+–+–+–+–+–
++
–+–+–+–+–+–+–
+–+
–
–+–+–+–+–+–+–
3
4
5
2
1
V.ADJ
100 (3.94)
50 (1.97)
440 (17.32)
460 (18.11)
480 (18.90)
AC POWER UNIT
132 (5.20) 26 (1.02) min.
156 (6.14)
7.3(.29)
64–M3.5
OUTPUT TERMINALS
OUTPUT 2 TERM.
OUTPUT 1 TERM.
5–M3.5 POWER
TERMINALS
6.6 (.26)
• M8BS2-162-R
12345678 9
10 11 12 13 14 15 16
123
CH1 CH8 CH9 CH16
+–+–+–+–+–+–+–+–
+–+–+–+–+–+–+–+–
++
–+–+–+–+–+–+–
+–+
–
–+–+–+–+–+–+–
100 (3.94)
50 (1.97)
440 (17.32)
460 (18.11)
480 (18.90)
3–M3.5
POWER TERMINALS
8.6 (.34)
92 (3.62)
POWER LED
132 (5.20) 26 (1.02) min.
OUTPUT 2 TERM.
OUTPUT 1 TERM.
7.3(.29)
64–M3.5
OUTPUT TERMINALS
M8BS2-162
P. 3 / 3EM-5495-2 Rev.2
CHECKING
1) Terminal wiring: Check that all cables are correctly con-
nected according to the connection diagram.
2)  Power  input  voltage:    Check  voltage  across  the  power 
terminals.
3) Installation & environment
MAINTENANCE
Power units' standard life is expected for 10 years with aver-
age ambient temperature 35°C (95°F) and 1.0A load.  Contact 
M-System for use in extremely different conditions.
■
HOW TO REPLACE THE POWER UNIT (power suffix code: M2)
1)  Prepare Power Unit (switching regulator) model HDC10.
2)  Turn off the power supply connected to the Power Unit.
3)  Remove  the  wire  binding  and  wiring  connected  to  the 
terminal 1 – 2 and 4 – 5.
4) Loosen and remove the mounting screws A(4 places).
5)  Detach the Power Unit from the Installation Base.
6)  Attach the new Power Unit to the Installation Base and 
tighten the screws in reverse order as explained above.
+
–
+
–
AC
POWER
UNIT
4
5
FG
3
U
V
AC POWER
FG
3
2
1
+
–
+
–
■ DC Power Supply ■ AC Power Supply
OUTPUT 1
OUTPUT 1
Ch.1
OUTPUT
Ch.16
OUTPUT
OUTPUT 1
OUTPUT 1
+
–
+
–
OUTPUT 2 OUTPUT 2
Ch.1
OUTPUT
+
–
+
–
OUTPUT 2 OUTPUT 2
Ch.16
OUTPUT
POWER
+
-
+
–
+
–
AC
POWER
UNIT
4
5
FG
3
U
V
AC POWER
FG
3
2
1
+
–
+
–
■ DC Power Supply ■ AC Power Supply
OUTPUT 1
OUTPUT 1
Ch.1
OUTPUT
Ch.16
OUTPUT
OUTPUT 1
OUTPUT 1
+
–
+
–
OUTPUT 2 OUTPUT 2
Ch.1
OUTPUT
+
–
+
–
OUTPUT 2 OUTPUT 2
Ch.16
OUTPUT
POWER
+
-
■ CONNECTION DIAGRAM
M-SYSTEM WARRANTY
M-System warrants such new M-System product which it manufactures to be free from defects in materials and workmanship during the 36-month period following the date that such
product was originally purchased if such product has been used under normal operating conditions and properly maintained, M-System’s sole liability, and purchaser’s exclusive
remedies, under this warranty are, at M-System’s option, the repair, replacement or refund of the purchase price of any M-System product which is defective under the terms of this
warranty. To submit a claim under this warranty, the purchaser must return, at its expense, the defective M-System product to the below address together with a copy of its original
sales invoice.
THIS IS THE ONLY WARRANTY APPLICABLE TO M-SYSTEM PRODUCT AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. M-SYSTEM SHALL HAVE NO LIABILITY FOR CONSEQUENTIAL, INCIDENTAL OR
SPECIAL DAMAGES OF ANY KIND WHATSOEVER.
M-System Co., Ltd., 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN, Phone: (06) 6659-8201, Fax: (06) 6659-8510, E-mail: info@m-system.co.jp
3
4
5
2
1
V.ADJ
AA
A
A
A
1
2
3
4
5
: Mounting screws with
washer, M3 x 6 (4 pls.)
: 24V DC (+)
: 24V DC (–)
: FG
: AC power input (U)
: AC power input (V)

Other M-system Network Hardware manuals

M-system R30NCIE1 User manual

M-system

M-system R30NCIE1 User manual

M-system RGP30 User manual

M-system

M-system RGP30 User manual

M-system M8BS-8E3A User manual

M-system

M-system M8BS-8E3A User manual

M-system R30NCIT1 User manual

M-system

M-system R30NCIT1 User manual

M-system M5XSBS User manual

M-system

M-system M5XSBS User manual

Popular Network Hardware manuals by other brands

Sun Microsystems Storedge A7000 installation guide

Sun Microsystems

Sun Microsystems Storedge A7000 installation guide

Commander ATA302 quick start guide

Commander

Commander ATA302 quick start guide

CORNING EDGE Installation

CORNING

CORNING EDGE Installation

ADC HiGain H2TU-C-231 manual

ADC

ADC HiGain H2TU-C-231 manual

Wisstar WP-N6504-E1-4P user manual

Wisstar

Wisstar WP-N6504-E1-4P user manual

Quatech ABDG-SE-HD101 series Features

Quatech

Quatech ABDG-SE-HD101 series Features

Dell EMC NX3240 Setting up

Dell

Dell EMC NX3240 Setting up

Eneo IER-38R160005A user manual

Eneo

Eneo IER-38R160005A user manual

Ross Ultrix Acuity Installation and cabling guide

Ross

Ross Ultrix Acuity Installation and cabling guide

E+E Elektronik EE240 user manual

E+E Elektronik

E+E Elektronik EE240 user manual

evertz exponent 500ACO2-HD/SD manual

evertz

evertz exponent 500ACO2-HD/SD manual

Polycom RMX 1500 Installation & quick start guide

Polycom

Polycom RMX 1500 Installation & quick start guide

XenData SXL-1000 Getting started

XenData

XenData SXL-1000 Getting started

Ubiquiti RD-3G26 quick start guide

Ubiquiti

Ubiquiti RD-3G26 quick start guide

Cabletron Systems MMAC-5FNB Networking guide

Cabletron Systems

Cabletron Systems MMAC-5FNB Networking guide

Cox Business Net Assurance quick start guide

Cox Business

Cox Business Net Assurance quick start guide

ADF Web HD67561 user manual

ADF Web

ADF Web HD67561 user manual

Idis DR-2404P installation manual

Idis

Idis DR-2404P installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.