M-TI CX FLEX User manual

CX FLEX™ SINGLE ALARM ONLY PRODUCT MANUAL
1
MTI P/N 063-00306 rev 1 ©2019 MTI All Rights Reservedwww.mtigs.com | T:800.426.6844
Product Manual for
CX FLEX™ Single Alarm Only
DO NOT REMOVE FROM STORE
Contents
1. Installation 2
2. Key Whitelist 3
3. Merchandising 3
4. Managing Alarms 4
5. Cable Removal 4
6. Remerchandising 4
7. Adding New User Keys 5
8. Deleting Whitelist 5
9. Battery Replacement 6
10. Position Removal 6
11. LED Status Indicators 7
12. Dimensions 8
13. FCC and ISED Statement 9
For additional support, please reach out to our
Contact Center at 800-426-6844
CONTENTS

1
3
2
CX FLEX™ SINGLE ALARM ONLY PRODUCT MANUAL
2
MTI P/N 063-00306 rev 1 ©2019 MTI All Rights Reservedwww.mtigs.com | T:800.426.6844
Press down on the base plate for 10 seconds for full VHB contact. Allow 24 hours for full VHB adhesion.
Clean the desired surface with an alcohol pad allow it to completely dry. Peel the red lm from the VHB adhesive.
If needed, clean the underside surface with an alcohol pad and allow to dry. Place new VHB on the puck.
INSTALLATION

1
132
3
USB-C Sensor: Insert the other end of the cable into
the device.
Plug the USB-C end of the sensor into the CX Flex until it
clicks.
Flexi-Disc Sensor: Peel the red lm from the VHB
adhesive and press rmly onto the product for 1
minute if the product surface is curved, or 30 seconds
if it is at.
System will auto-arm after 1 minute, or arm
immediately by holding a whitelisted User Card over
the RFID Icon.
click
2b
2a
CX FLEX™ SINGLE ALARM ONLY PRODUCT MANUAL
3
MTI P/N 063-00306 rev 1 ©2019 MTI All Rights Reservedwww.mtigs.com | T:800.426.6844
MERCHANDISING
KEY WHITELIST
Place Authorization Card over the
RFID icon to register to system.
System must be disarmed
to perform this operation.
Place the User Key you want to
add over the RFID icon.
If successful unit beeps 2 times
Repeat process for all User Keys
until they are successfully added.
To close the whitelist mode, place
the Authorization Card over the
RFID icon. Whitelist mode will end
automatically after 3 minutes of no
use.

1
132
2
CX FLEX™ SINGLE ALARM ONLY PRODUCT MANUAL
4
MTI P/N 063-00306 rev 1 ©2019 MTI All Rights Reservedwww.mtigs.com | T:800.426.6844
To silence an alarm, hold the user card over the RFID icon. To disarm after silencing an alarm, hold the user card over the
RFID icon for 5 seconds.
MANAGING ALARMS
1
2Remove the cable.
Insert a corner of the RFID card into the slot and press
down until the cable ddetaches.
REMERCHANDISING
CABLE REMOVAL
Re-arm by holding user card over
RFID icon or system will auto-arm
after 1 minute. LEDs will be OFF
when the system is armed.
Insert new cable until it clicks.From an armed state, place the
user key over the RFID icon to
disarm the system. LED will be
ashing red (2 short ashes every
10 seconds). Then remove the
cable. Once the cable is removed,
the LEDs will stop ashing.
click

2
From an armed state, place the user key over the RFID
icon to disarm the system. LED will be ashing red.
1
CX FLEX™ SINGLE ALARM ONLY PRODUCT MANUAL
5
MTI P/N 063-00306 rev 1 ©2019 MTI All Rights Reservedwww.mtigs.com | T:800.426.6844
1 2 3
DELETING WHITELIST (This will delete all User Keys from the system.)
ADDING NEW USER KEYS
Hold down the Authorization Card
for 5 seconds, and a chirping
sound will start.
Place Authorization Card over the RFID icon. Follow Key
Whitelist process starting on page 3.
From an Armed state, place the
User Key over the RFID icon to
disarm the system. LED will be
ashing red.
Place the Authorization Card over
the RFID icon AGAIN during the
10 second chirp sequence.
If successful unit beeps 2 times
and chirps stop

CX FLEX™ SINGLE ALARM ONLY PRODUCT MANUAL
6
MTI P/N 063-00306 rev 1 ©2019 MTI All Rights Reservedwww.mtigs.com | T:800.426.6844
1
1
2
2
3
3
POSITION REMOVAL
BATTERY REPLACEMENT
Use CR2450 Batteries ONLY.
CAUTION: Risk of explosion if the
battery is replaced by an incorrect
type.

CX FLEX™ SINGLE ALARM ONLY PRODUCT MANUAL
7
MTI P/N 063-00306 rev 1 ©2019 MTI All Rights Reservedwww.mtigs.com | T:800.426.6844
WARNINGS
LED STATUS INDICATORS
Visual Reference System Status Condition Solution
LED is OFF.
1. Factory Reset
2. No product merchandised or
not properly merchandised
3. Armed
4. Battery needs to be replaced
1. No User or Authorization cards are registered, LEDs will
not ash when properly merchandised, system will not arm
-- Create Whitelist per Page 3.
2. Check connections for proper merchandising.
3. System is armed.
4. Replace battery with CR2450
LED is ashing red, 2 times
every 10 seconds. Disarmed, but able to be armed System is disarmed and is ready to re-arm.
LED is continuously
ashing red. Alarming System is alarming and requires immediate attention.
1. For indoor use only, shall not be exposed to dripping or splashing.
2. Do not expose to excessive heat sources, sunshine, fire or the like.
3. The socket-outlet shall be installed near the equipment and shall be easily accessible.
4. No user replaceable parts inside, refer servicing to manufacturer specified agency or qualified service
personnel.
5. Only use accessories/battery specified by the manufacturer.
Disposal:
All electrical and electronic products including batteries should be disposed of separately
from the municipal waste stream via designated collection facilities appointed by the
government or the local authorities.

CX FLEX™ SINGLE ALARM ONLY PRODUCT MANUAL
8
MTI P/N 063-00306 rev 1 ©2019 MTI All Rights Reservedwww.mtigs.com | T:800.426.6844
DIMENSIONS
2.36”
1.09”
1.87”

CX FLEX™ SINGLE ALARM ONLY PRODUCT MANUAL
9
MTI P/N 063-00306 rev 1 ©2019 MTI All Rights Reservedwww.mtigs.com | T:800.426.6844
FCC AND ISED STATEMENT
This device complies with Innovation, Science and Economic Development Canada licence-exempt RSS standard(s). Operation is subject to the following
two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause
undesired operation of the device.
CAN ICES-3(B)/NMB-3(B)
Le présent appareil est conforme aux CNR Innovation, Sciences et Développement économique Canada applicables aux appareils radio exempts de licence.
L’exploitation est autorisée aux deux conditions suivantes:
(1) il ne doit pas produire de brouillage et (2) l’ utilisateur du dispositif doit étre prêt à accepter tout brouillage radioélectrique reçu, même si ce brouillage
est susceptible de compromettre le fomctionnement du dispositif.
CAN ICES-3(B)/NMB-3(B)
The device meets the exemption from the routine evaluation limits in section 2.5 of RSS 102 and compliance with RSS-102 RF exposure, users can obtain
Canadian information on RF exposure and compliance.
Le dispositif rencontre l’exemption des limites courantes d’évaluation dans la section 2.5 de RSS 102 et la conformité à l’exposition de RSS-102 rf,
utilisateurs peut obtenir l’information canadienne sur l’exposition et la conformité de rf.
This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This equipment should be installed and operated
with a minimum distance of 20 millimeters between the radiator and your body.
Cet émetteur ne doit pas être Co-placé ou ne fonctionnant en même temps qu’aucune autre antenne ou émetteur. Cet équipement devrait être installé et
actionné avec une distance minimum de 20 millimètres entre le radiateur et votre corps.
This device complies with Part 15 of the FCC Rules.
Caution: If any changes or modications not expressly approved by the party responsible for compliance could void the user’s authority to operate the
equipment.
Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference
received, including interference that may cause undesired operation.
The grantee is not responsible for any changes or modications not expressly approved by the party responsible for compliance. Such modications could
void the user’s authority to operate the equipment.
The RF Exposure Compliance distance is 20 millimeters.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more
of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
—Consult the dealer or an experienced radio/TV technician for help.
Operating Frequency: 125kHz
Operating Temperature: 0° C to 40° C
Max Power: 125kHz: <42dBuA/m at 10m
FCC ID: 2AA2X-15000221
Model: CX Flex 1A
FCC Statement
ISED Certification Number: 24439-15000221
Model: CX Flex 1A
ISED Statement
Technical Data
Mobile Technologies Inc. - 1050 NE 67th Ave, Hillsboro, OR 97124
Table of contents
Other M-TI Security Sensor manuals
Popular Security Sensor manuals by other brands

Johnson Controls
Johnson Controls F62AA Installation Sheets Manual

SGB
SGB DLR-P CV Series Documentation

AKO
AKO AKO-522034 manual

S+S Regeltechnik
S+S Regeltechnik AERASGARD APS-SD Operating Instructions, Mounting & Installation

S+S Regeltechnik
S+S Regeltechnik KINASGARD DBWF Operating Instructions, Mounting & Installation

Visonic
Visonic MCT-550 install guide