M-TI RAPIDDOC LITE User manual

RAPIDDOC™LITE INSTALLATION GUIDE
1
MTI P/N 063-00223 rev C ©2020 MTI All Rights Reservedwww.MTIGS.com | T:800.426.6844
Parts
Power Supply
RFID Access Card (x5)
(included with RFID Reader only)
(included with RFID Reader only)
RFID Authorization Card
Hardware
VESA/Wall Mounting Plate
Wall Trim Plate
Wall Mount Base w/ AC InputBase Cover
Red Handle Tool
Security
Screw
x4 in Wall Mount Kit
x8 in VESA Mount Kit
-CONTROLLED DOCUMENT- 063-00223 C-0 Status: Approved ECO-111786
ECO-111786

RAPIDDOC™LITE INSTALLATION GUIDE
2
MTI P/N 063-00223 rev C ©2020 MTI All Rights Reservedwww.MTIGS.com | T:800.426.6844
Dimensions
Mounting PlateWall Base
Wall Mount Kit RFID Reader (Optional)
2.78”
4.86”
4.24”
1.1”
4.69”
1.71”
VESA Mount Kit RFID Reader (Optional)
9.25” 48”
Cable
3”
5”
-CONTROLLED DOCUMENT- 063-00223 C-0 Status: Approved ECO-111786
ECO-111786

RAPIDDOC™LITE INSTALLATION GUIDE
3
MTI P/N 063-00223 rev C ©2020 MTI All Rights Reservedwww.MTIGS.com | T:800.426.6844
1
3 4
2
Wall Mount Kit - Pre-Installation
Use the holes circled in pink on the mounting plate for
installation on a Single Gang Box and those circled in
blue for installation on a Double Gang Box.
48”
RFID
Cable
RapidDoc
RapidDoc
Determine the location of the RFID Reader, within the
48” length of the RFID cable.
It is recommended to install the RapidDoc using a Gang
Box attached to a wall stud. Pull the charging cable from
the power supply cable to the Gang box.
Install the RFID Flush Mount on the wall (use anchor
bolts if necessary).
-CONTROLLED DOCUMENT- 063-00223 C-0 Status: Approved ECO-111786
ECO-111786

RAPIDDOC™LITE INSTALLATION GUIDE
4
MTI P/N 063-00223 rev C ©2020 MTI All Rights Reservedwww.MTIGS.com | T:800.426.6844
3 4
1 2 Attach the RFID module to the mounting back with a
twisting motion. The module will automatically lock into
place.
To release the module, insert the Red Handle Tool where
shown and turn it counter-clockwise, which will allow the
module to rotate counter-clockwise out of the mount.
Route the loose end of RFID cable from the RFID Module;
through the hole and the wall to the Gang box.
RFID Installation
Pull the charging cable from the power supply and RFID
cable out of the Gang Box.
It is recommended to
use a Gang Box that is
securely attached to a
wall stud.
-CONTROLLED DOCUMENT- 063-00223 C-0 Status: Approved ECO-111786
ECO-111786

RAPIDDOC™LITE INSTALLATION GUIDE
5
MTI P/N 063-00223 rev C ©2020 MTI All Rights Reservedwww.MTIGS.com | T:800.426.6844
21
43
65
Wall Mount Base Installation
Rotate the base cover clockwise until you feel the cover
click and lock into place.
Place the Base Cover over the RapidDoc Base.
Attach the Wall Mount Base to the Mounting Plate.
Connect the RFID cable into the Wall Mount Base.
Connect the power supply cable into the Wall Mount
Base.
Line up the holes on the trim plate and the mounting
plate with the holes on the gang box. Install using the 4
long gang box screws included, with the cables coming
out of the inner ring.
Ensure that this slot aligns with
the manual unlock security screw
in the base mount.
-CONTROLLED DOCUMENT- 063-00223 C-0 Status: Approved ECO-111786
ECO-111786

RAPIDDOC™LITE INSTALLATION GUIDE
6
MTI P/N 063-00223 rev C ©2020 MTI All Rights Reservedwww.MTIGS.com | T:800.426.6844
21
43
65
Connect the power supply into the wall mount base. Connect the RFID cable into the Wall Mount Base.
Attach the VESA Bracket and Mounting plate to a VESA
xture (not included).
If you are using the VESA Bracket, make sure you pull
enough power supply cable out of the wall to reach the
Wall Mount Base once it is attached to the VESA mount
bracket.
VESA Base Installation
Attach the Wall Mount Base to the Mounting Plate. Place the Base Cover over the RapidDoc Base and rotate
clockwise until you feel the cover click, and it locks into
place.
Ensure that this slot aligns with
the manual unlock security screw
in the base mount.
-CONTROLLED DOCUMENT- 063-00223 C-0 Status: Approved ECO-111786
ECO-111786

RAPIDDOC™LITE INSTALLATION GUIDE
7
MTI P/N 063-00223 rev C ©2020 MTI All Rights Reservedwww.MTIGS.com | T:800.426.6844
3
1 2
Registering Access Cards
Make sure the RapidDoc RFID Module is powered and
ready.
Place a RFID Access card on the RFID Module until
LED ashing stops and returns to solid red.
Place the RFID Authorization Card on the RFID Module
until the LED ashes.
IF AUTHORIZATION CARD IS LOST OR STOLEN,
CONTACT CUSTOMER SERVICE FOR REPLACEMENT.
4If no Access Card is detected, the Base will return to
normal condition waiting for registered Access Card to
unlock the Base. The Base can register a maximum of
20 Access cards. The process will need to be repeated
for each card. If a 21st card is registered, the rst
registered card will be deregistered.
-CONTROLLED DOCUMENT- 063-00223 C-0 Status: Approved ECO-111786
ECO-111786

RAPIDDOC™LITE INSTALLATION GUIDE
8
MTI P/N 063-00223 rev C ©2020 MTI All Rights Reservedwww.MTIGS.com | T:800.426.6844
3 4
1 2
If a card is lost or stolen: Then re-register the remaining cards plus the new one
ordered through Customer Service.
If a 21st card is registered, the rst registered card will
be deregistered.
The base can register a maximum of 20 Access cards.
Registering Access Cards
NOTE: The above grid is a conceptual visual
representation of the Electronic Register.
ACCESS005
ACCESS004
ACCESS003
ACCESS002
ACCESS001
ACCESS005
ACCESS004
ACCESS003
ACCESS002
ACCESS001
ACCESS006
ACCESS005
ACCESS004
ACCESS002
ACCESS001
ACCESS006
ACCESS005
ACCESS004
ACCESS003
ACCESS002
IF AUTHORIZATION CARD IS LOST
OR STOLEN, CONTACT CUSTOMER
SERVICE FOR REPLACEMENT.
-CONTROLLED DOCUMENT- 063-00223 C-0 Status: Approved ECO-111786
ECO-111786

RAPIDDOC™LITE INSTALLATION GUIDE
9
MTI P/N 063-00223 rev C ©2020 MTI All Rights Reservedwww.MTIGS.com | T:800.426.6844
1
1
2
2
Docking
The case is secure when it clicks into the base.Dock the case to the base by moving case towards the
base, aligning the disk on the case to the disk on the
base.
NOTE: Wait 30 seconds between Access Card swipes or the latches
may overheat. The LED will start Flashing Orange. Wait until the
flasing stops (approximately 2 minutes) and Try again. If your tablet does
not release, try using the Red Handle Tool to manually remove the tablet.
RFID Release
Within ve seconds, remove the case away from the
base. If the case is not removed within ve seconds, the
lock will re-engage. Up to 10 access tries are allowed,
then a two minute waiting period before another try will
be triggered.
Place a registered Access Card on the RFID module, the
LED indicator will begin to ash.
-CONTROLLED DOCUMENT- 063-00223 C-0 Status: Approved ECO-111786
ECO-111786

RAPIDDOC™LITE INSTALLATION GUIDE
10
MTI P/N 063-00223 rev C ©2020 MTI All Rights Reservedwww.MTIGS.com | T:800.426.6844
1 2
LED Status
Case Docked
Case Removed
Case Ready for Removal
12V Tablet Warning
RapicdDoc Lite only
supports 5V Apple
Tablets. If you place a
12V Tablet on a Lite
base, the LED will start
flashing and the latches
will click 10 times.
Remove the Tablet or
it will be locked for 2
minutes.
Manual Release
Use the other hand to remove the case while keeping the
security screw turned.
Insert the Red Handle Tool into the security screw hole at
the bottom of the RapidDoc base-disk under the tablet.
Turn the Red Handle Tool clockwise until resistance is
felt (about halfway) and hold.
Do not grab the tablet until after
you twist the Red Handle Tool, the
magnets in the case will keep the
tablet securely in place.
-CONTROLLED DOCUMENT- 063-00223 C-0 Status: Approved ECO-111786
ECO-111786

RAPIDDOC™LITE INSTALLATION GUIDE
11
MTI P/N 063-00223 rev C ©2020 MTI All Rights Reservedwww.MTIGS.com | T:800.426.6844
Mounting Template
Print this document at 100% (or ‘Actual Size’) to mark the drill holes for
installing the RapidDoc RFID Flush Mount Plate.
-CONTROLLED DOCUMENT- 063-00223 C-0 Status: Approved ECO-111786
ECO-111786

RAPIDDOC™LITE INSTALLATION GUIDE
12
MTI P/N 063-00223 rev C ©2020 MTI All Rights Reservedwww.MTIGS.com | T:800.426.6844
FCC Interference Statement
Federal Communication Commission interference statement
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur
in a particular installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following measures: -Reorient or relocate the receiving
antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into
an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an
experienced radio/TV technician for help.
FCC Caution
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. this device may not cause harmful interference and
2. this device must accept any interference received, including interference that may cause undesired
operation
RF Exposure Warning
The equipment complies with RF exposure limits set forth for an uncontrolled environment. The
antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other
antenna or transmitter.
You are cautioned that changes or modications not expressly approved by the party responsible for
compliance could void your authority to operate the equipment.
-CONTROLLED DOCUMENT- 063-00223 C-0 Status: Approved ECO-111786
ECO-111786
Table of contents