MOLIVA3D C3 TO LCDBC CONNECTION
In order to communicate with LCDBC, three requirements must be met:
Connection from the C3 to the LCDBC.
o A serial straight-through cable is included with the C3 to connect to the newest LCDBC
version. However, an older version requires the connection as seen in Figure 7.
LCDBC with upgraded firmware that contains communication functionality.
o For LCDBC firmware upgrade instructions, please visit http://lcdbc.xp3.biz/
LCDBC Configuration
o When powering on the LCDBC, push the rotary switch in (rotary switch button) and hold
it to enter configuration mode. Scroll until the text Datalog appears and change it to
TFT (Datalog=TFT) and push the rotary switch button to save. Remove and reapply
power to the LCDBC to boot it up normally.
Figure 7 - Earlier LCDBC Model Connection to C3
When the function button is pressed to switch to either the LCDBC Diagnostic or LCDBC Plot Screens, C3
will attempt to make a connection to the LCDBC. If the C3 is unable to connect, the screen shown in
Figure 8 will appear.
Figure 8 - LCDBC Connection Error
The C3 will attempt three times every three seconds to make connection to the LCDBC. If connection
cannot be established, the C3 will revert back to the climate control screen.