Brown
Blue
Gray
White
Green - Data 1
Yellow - Data 0
Red - 12V
Black - GND
Induced surge will travel both way via
cable to damage device at end point.
CABLE TRAVELING INSIDE PIPING
(Subject to lightning surge induction)
Signal Power
Dual Technology RFID
ACTIVE DIRECTIONAL READER
MAG
INSIDE GUARD HOUSE
(Safely protected by surge protector at end point.
All surge protector MUST be connect to EARTH.)
TPLAN
Data surge
protector
PD12/7.5
Data and
DC surge
protector
PSP12
protector
DC surge
Access controller
Data 1
Data 0
GND
Wiegand
port
OUTSIDE NEAR BARRIER GATE
AR500 U
RFID Long Range
12 V
GND
DC Power Supply
12V,3A
Common
GND
MAG AR500U Quick User Manual
D131
D132
Auto IR signal adjustment
Manual IR signal adjustment
D131 D132
S1S2S3S4
ABCD
D127 D136
LED Description
S1
S3
S2
S4
Reader enable/disable
WG 26/34 mode selection
WORK
VDS and ADD is not used.
Blinking to indicate normal
function
Not used
(A) How to Increase signal strength?
1. Press Button C until LED D132 turn on.
2. Press button D to increase signal strength. There are
8 LEDs to indicate IR strength level (D127 to D136). As
you press button D, you will notice more LED will turn
on to indicate higher signal strength.
Programming
A = Setting selection (S1, S2, S3 or S4)
B = Conrm and exit setting mode
C = IR auto/manual mode
D = IR strength adjustment
D127 D136
Minimum Maximum
Optimum
(default)
LED to indicate IR signal strength
Button for programming and setting
Not used
Power LED
Read card LED
AD1 - AD5 Reader address 1 to 5
AD1 to AD5
WORK
(C) How to enable/disable card reading?
1. Press button A until S1 blinking
2. Press button B to change LED S1 on/o status
Turn on LED S1 to enable reader
Turn o LED S1 to disable reader
(B) How to change wiegand output format WG26/WG34?
1. Press button A until LED S3 is blinking
2. Press button B to change LED S3 on/o status.
Turn on LED S3 for WG26
Turn o LED S3 for WG34
LED to indicate setting status
(Safely protected by surge protector at end point.
All surge protector MUST be connect to EARTH.)
AR500U must be turned toward transponder to achieve shortest distance straight line of
sight within 1.8 to 2.5 meter range. This is to ensure maximum energy transfer to achieve
longest reading range.
It is recomended to install transponder on the same side with AR500u at entry and exit to
achieve consistent reading angle.
There is no need to install additional loop detector to enable/disable reader. Reader IR
coverage should be sucient to ensure accurate reading within desired range.
Recomended installation layout for best reading performance
line of sight
line of sight
line of sight
1.5 m 1.8 to 2.5 m
loop coil
for barrier
loop coil
for barrier
How to achieve best reading range ?
Conned
reading range
CORRECT
Reading range is conned
to specic region for
accurate reading.
20
recomended reader height
5.5 to 6.5 feet
WRONG
Uncontrolled reading range
will cause false reading
and anti-passback problem
Horizontal innity
reading range
Troubleshooting guide
Why reader not able to read CCD200 transponder if car installed Vkool or 3M solar lm?
Please increase reader IR strength to achieve higher penetration into premium brand solar
lm. Extremely high level of metal oxide in some premium solar lm might totally inhibit
any RF signal to pass through causing reader will not able to read CCD200.
Why my transponder or tag not working ?
Please kindly try to read the transponder outside of the car or with windows winded down.
If transponder can still be read at shorter distance, battery might be too weak. This often
indicates it is time to change new battery.
Typically AR500 can achieve 1.8 to 7 meter reading range depending on solar lm
installed on vehicle. Please use CCD200 to achieve true handsfree long range reading.
CCD100 has shorter reading range for manual ashing by hand.
Surge protection
a) AR500U installed outdoor is subject to damaged by lightning surge. It is compulsary to
install data and power surge protector as shown in wiring diagram.
b) Good Earth connection onto the metal pole and all metal housing will give extra
protection against damage by lightning surge.
Battery included in CCD100 and CCD200 is for demo purpose only. It does necessary
provide full life time. Typically the demo battery will run out about 6 months time. Please
kindly change a new battery after the demo battery runs out.
CCD100 is using 2 x 2032 coin battery
CCD200 is using 2 x 2045 coin battery
Removing proximity card from CCD200 will turn o transponder for energy saving. There
is a switch beside CCD100 to turn it o/on. CCD100 can be turned o if not used for long
time.
When reading range gets shorter, it is indication that battery starts to be weak. Changing
a new battery will resume normal reading range.
Changing battery in transponder / tag
Stick to winshield glass to achieve
TRULY handsfree access. CCD200 will
be read automatically as vehicle
approach reader.
Alternatively, CCD200 also can be ashed
manually by hand for user that does not
want to stick it permanently on to the
windshield glass.
CCD100 has shorter reading range.
It is easier to achieve line of sight if
ash manually by hand.
Please ensure that
the IR sensor is not
blocked by ngers.

Popular Card Reader manuals by other brands

Ravpower RP-WD007 Advanced user's guide

Ravpower

Ravpower RP-WD007 Advanced user's guide

Kiwitron ETS Quick start manual

Kiwitron

Kiwitron ETS Quick start manual

Microscan MS-3 CCD quick start guide

Microscan

Microscan MS-3 CCD quick start guide

Shenzhen Clou IOT Technologies Co., Ltd CL7206B5A user manual

Shenzhen Clou IOT Technologies Co., Ltd

Shenzhen Clou IOT Technologies Co., Ltd CL7206B5A user manual

Lexar EXPRESSCARD COMPACT FLASH READER - DATASHEET REV... datasheet

Lexar

Lexar EXPRESSCARD COMPACT FLASH READER - DATASHEET REV... datasheet

Vicon VAX-D6.4R Quick installation guide

Vicon

Vicon VAX-D6.4R Quick installation guide

ACS ACR101 Reference manual

ACS

ACS ACR101 Reference manual

Parabit Systems ACS-1E Installation and service manual

Parabit Systems

Parabit Systems ACS-1E Installation and service manual

Conrad 41 60 92 operating instructions

Conrad

Conrad 41 60 92 operating instructions

turck TN-UHF LNX Series Instructions for use

turck

turck TN-UHF LNX Series Instructions for use

Inepro Spider Desktop Assembly manual

Inepro

Inepro Spider Desktop Assembly manual

DeLOCK 91629 user manual

DeLOCK

DeLOCK 91629 user manual

Conrad Desk operating instructions

Conrad

Conrad Desk operating instructions

urmet domus FDi FD-020-091 installation guide

urmet domus

urmet domus FDi FD-020-091 installation guide

Raymarine RCR-SDUSB installation instructions

Raymarine

Raymarine RCR-SDUSB installation instructions

Rosewill RCR-IM5001 User manaul & installation

Rosewill

Rosewill RCR-IM5001 User manaul & installation

Tru-Test XRP2 quick start guide

Tru-Test

Tru-Test XRP2 quick start guide

SmartDisk PhotoBank user guide

SmartDisk

SmartDisk PhotoBank user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.