2 MAGICFX® —User and Installation Manual
Read this manual carefully before installing and/or using this
product. Failure to read the manual and to follow the printed
instructions may lead to personal injury and/or damage to the
product.
© 2020 MAGICFX®
All rights reserved.
Nothing from this publication may be copied, reproduced and/or published by
means of printing, photocopying or by any other means, without the prior written
approval of MAGIC FX.
MAGIC FX reserves the right to modify specications stated in this manual.
Any brand names mentioned in this manual are registered trademarks of their
respective owners.
MAGIC FX accepts no liability for claims from third parties arising from unauthorised
use, use other than that stated in this manual, and use other than in accordance with
the General Conditions registered at the Chamber of Commerce.
We further refer to the General Conditions. These are available on request, free of
charge.
Although considerable care has been taken to ensure a correct and comprehensive
description of all relevant components, the manual may nonetheless contain errors
and inaccuracies.
Should you detect any errors or inaccuracies in the manual, we would be grateful if
you would inform us. This helps us to further improve our documentation.

MAGICFX® —User and Installation Manual 3
Disclaimer 2
Trademarks 2
Liability 2
Foreword 4
Language 4
Revision table 4
1 Meet the MAGICFX®
3.2 Arm 10
4 Maintenance 13

4 MAGICFX® —User and Installation Manual
Congratulations! You have bought a great new product from MAGIC FX.
This manual contains all information required for the intended use of the equipment.
Deviation from the described intended use can result in a hazardous situation and/or
property damage.
This manual includes notes and warnings on safe operation of the equipment. These
notes and warnings are accompanied by the following icons. Read them attentively!
Indicates a hazardous situation that, if not avoided, will result in
death or serious injury. This signal word is to be limited to the most
extreme situations.
Indicates a hazardous situation that, if not avoided, could result
in death or serious injury.
Indicates a hazardous situation that, if not avoided, could result
in minor or moderate injury.
Indicates information considered important, but not hazard-
related (e.g. messages relating to property damage).
This document contains the original instructions in English. In case you require other
languages please contact MAGIC FX.
Doc nr Date Description Author
PART01882 01-00 23-04-2020 Initial release ES, MB RD

MAGICFX® —User and Installation Manual
1 MAGICFX®
The MAGICFX®FX-ARM CONTROLLER is a safety device used for remotely arming
special eects machines and providing an emergency stop (hereaer e-stop) button.
You can arm and e-stop multiple machines simultaneously or use each special
eects machine with a dedicated MAGICFX®FX-ARM CONTROLLER.
The MAGICFX®FX-ARM CONTROLLER does not replace the use of either DMX or 12-24V
control of your FX-machine. It is an independent safety circuit that works alongside
your separate control solution to increase the safety of your system.
1.1
POWER INPUT
(100 250 VAC)
ARM CONTROLLER
OUTPUT
E-STOP RESET
BUTTON
E-STOP
BUTTON
ARM/DISARM
SAFETY KEY
Main parts
1.2
Type plate

® —User and Installation Manual
1.3
Product Product Name MAGICFX®FX-ARM CONTROLLER
Product Code MFX3220
Product Type CONTROL GEAR
Main
Dimensions
Length 158 mm 6.2 in
Width 180 mm 7.1 in
Height 102 mm 4.0 in
Weight Weight 1.9 kg 4.2 lb
Package Length 309 mm 12.2 in
Width 364 mm 14.3 in
Height 187 mm 7.4 in
Packaged weight 2.7 kg 6 lb
Minimum Temperature -10 °C 14 °F
Maximum Temperature 50 °C 122 °F
Voltage Input 100 – 250 Vac
Voltage Frequency 50 – 60 Hz
Power Consumption 50 W
Power Connector Neutrik®powerCON TRUE1 (in)
ARM Connector Neutrik® etherCON, RJ45 (in & Out)
Control Options Manual
Technical data
1.4
Code Product
SPR90050 Key for FX-COMM4NDER and FX-ARM CONTROLLER (pair) 1x
MFX0313 Schuko to Neutrik®powerCON TRUE1 - cable 1.5 m
Accessories
Please contact MAGIC FX for additional possibilities.

MAGICFX® —User and Installation Manual
2
The MAGICFX®FX-ARM CONTROLLER has been designed and constructed in such a
manner that it can be used safely. This applies to the use, the circumstances and the
regulations as described in this documentation. Reading this documentation and
following the instructions are therefore necessary for everyone who is authorised to
work with the MAGICFX®FX-ARM CONTROLLER.
The MAGICFX®FX-ARM CONTROLLER must be used in surroundings that:
• Have a stable temperature of between -10 and 50 °C.
• Are free of dust, corrosive gases and high concentrations of organic vapours.
• Are not situated in the vicinity of a source of vibration.
2.1
• Only authorised persons may carry out work with the MAGICFX®FX-ARM
CONTROLLER.
• Do not use the MAGICFX®FX-ARM CONTROLLER if there are people or animals
in the direct output of FX-machines controlled by the MAGICFX®FX-ARM
CONTROLLER.
• Make sure that children, unauthorised people and animals do not obtain
access to the MAGICFX®FX-ARM CONTROLLER.
• Make sure there are no free-standing objects or objects that can be
damaged by the connected machines within the output distance.
• Do not remove any safeguards, safety caps and safety symbols.
• All required safety devices must be in good condition and function properly.
• Ensure sucient lighting of the surroundings.
• Keep the workplace clean.
• Refer to the manual(s) of the connected machine(s) for safety instructions
concerning the use of those machines.
2.2
The MAGICFX®FX-ARM CONTROLLER uses Arm cables terminated with RJ45
connectors to link to single or multiple eects machines. This is not compatible with
any other data protocol and these cables must not be connected to any other
product other than specic MAGICFX® eects machines with the integrated safety
circuit hardware. Connecting RJ45 leads from other systems carrying other data
protocols may damage your hardware.
2.3
Using a damaged MAGICFX®FX-ARM CONTROLLER can lead to
death, serious injury or property damage. Always inspect the
controller thoroughly before operation.

® —User and Installation Manual
Make sure the Arm cables from this MAGICFX®FX-ARM
CONTROLLER are not connected into any products that are not
compatible with this safety device as this may damage your
hardware. Likewise, do not connect any RJ45 cables from any
other system carrying a dierent data protocol as this may
damage your hardware.
Only one MAGICFX®FX-ARM CONTROLLER can be used in a
single connected system. Connecting more than one controller
with RJ45 Arm leads can cause damage to them.
3
3.1
1 Place the controller on a stable surface in a suitable area.
2 Make sure the arm/disarm key is in the ‘OFF’ position and the e-stop button is
not pressed in.
if the e-stop is pressed in it can be released with a clockwise
quarter turn.
3 Connect the PowerCon TRUE1 power cable to the power input of the controller.

MAGICFX® —User and Installation Manual 9
POWER IN POWER OUT POWER OUT POWER OUT POWER OUT
PowerCon TRUE1 female
POWER
4 Connect the other end to a power outlet.
Connect the FX-machines to the controller with Arm cables, either by a direct
cable or daisy chain conguration.
ARM IN ARM OUT
ARM EtherCONEtherCON
The MAGICFX®FX-ARM CONTROLLER can be placed either at the
end of the safety cable line or anywhere within a linked system
using the Arm Input and output connectors on the machines.
Only one MAGICFX®FX-ARM CONTROLLER can be used in a
linked system.
Only one MAGICFX®FX-ARM CONTROLLER can be used in a
single connected system. Connecting more than one controller
with RJ45 Arm leads can cause damage to them.

10 MAGICFX® —User and Installation Manual
Remove the key from the keyswitch when you leave the controller unattended.
3.2
1 Place the key in the key switch and set the arm/diarm key in the ‘OFF’ position.
Ensure the e-stop button is not pressed in.
The e-stop reset button should be lit up white.
2 Press the e-stop reset button.
The e-stop reset button light will go o and the e-stop will now illuminate.
You cannot activate the e-stop reset button when the e-stop
button is pressed in. Make sure the e-stop is released when trying
to activate the e-stop reset button.
3 Set the arm/disarm key in the ‘ON’ position.
The FX LED Indicator lights up red.

MAGICFX® —User and Installation Manual 11
4 When you are done with ring the FX-machine, set the arm/disarm key to the
‘OFF’ position to deactivate the FX-machines.
The FX LED indicator turns o on the FX-ARM CONTROLLER.

12 MAGICFX® —User and Installation Manual
3.3
With the key switch in the ‘ON’ position the e-stop should be
illuminated and the FX LED Indicator Red.
1 Press the e-stop button in.
The illuminated e-stop button will turn o.
The FX LED indicator turns o and the e-stop reset button turns on.
2 Set the keyswitch in the ‘OFF’ position.
3 Wait for danger to be averted, then reset the arm controller by the following
steps.
4 Release the e-stop with a clockwise quarter turn.
The e-stop reset button will be illuminated white.

MAGICFX® —User and Installation Manual 13
Press the e-stop reset button.
The e-stop reset button light will go o and the e-stop button will now illuminate.
The FX-ARM CONTROLLER is ready for use again.
To achieve the maximum service life of the MAGICFX®FX-ARM CONTROLLER you must
regularly clean the MAGICFX®FX-ARM CONTROLLER and test if it is functioning
correctly.
Contact MAGIC FX if the MAGICFX®FX-ARM CONTROLLER is not functioning correctly.
Do not replace parts yourself; always consult MAGIC FX.
4
Always contact MAGIC FX if any malfunctions or errors occur that cannot be solved
with the instructions as described in this manual.
This symbol on the product and / or accompanying documents
means that used electrical and electronic products should not be
mixed with general household waste. For proper treatment,
recovery and recycling, please take this product to designated
collection points where it will be accepted free of charge.
Alternatively, in some countries you may be able to return your
products to your local retailer upon purchase of an equivalent new
product.
Disposing of this product correctly will help save valuable resources and prevent any
potential negative eects on human health and the environment, which could
otherwise arise from inappropriate waste handling.
Please contact your local authority for further details of your nearest designated
collection point.
Penalties may be applicable for incorrect disposal of this waste, in accordance with
your national legislation.

14 MAGICFX® —User and Installation Manual
DECLARATION OF CONFORMITY
According to Annex III A Machinery Directive 2006/42/EC
MAGIC FX B.V. declares as manufacturer and composer of the technical construction file that the
product with the following specifications:
Name machine : FX-ARM CONTROLLER
Type : MFX3220
Voltage : 100-250Vac 50/60Hz
Serial number : on product
Year of construction : on product
Is in conformity with the minimal safety regulations as stated in the following directive(s):
•LVD (2014/35/EU) Low Voltage Directive
•EMC (2014/30/EC) ElectroMagnetic Compatibility
•RoHS (2011/65/EU) Restriction of the use of certain Hazardous Substances
•WEEE (2012/19/EU) Waste Electrical & Electronic Equipment
The following harmonized standards were applied:
•NEN-EN-ISO 12100:2010 Safety of machinery - General principles for design - Risk
assessment and risk reduction.
•NEN-EN-IEC 60204-1:2006, Safety of machinery - Electrical equipment of machines - Part 1:
General requirements.
•NEN-EN-IEC 61000-6-3:2007/A1:2011, Electromagnetic compatibility (EMC) - Part 6-3:
Generic standards - Emission standard for residential, commercial and light-industrial
environments.
Original declaration of conformity
Translation of the original declaration of conformity
Name manufacturer : MAGIC FX B.V.
Address : Schouwrooij 27, 5281 RE BOXTEL
Country : The Netherlands
CEO : B. Veroude
Date : 5-3-2020
Signature :


WWW.MAGICFX.EU