MAGICFX® —User and Installation Manual
Make sure the outputs are deactivated before activating the safety address. The
safety address cannot be activated when one or more outputs are activated.
When you link multiple machines with DMX, we advise you to use the same Safety address for all
machines.
Always plug in a DMX Terminator into the DMX output of the nal unit in the
control sequence. Using a DMX Terminator improves signal reliability.
In sequence mode, the ouputs are controlled individually.
In sequence mode the MAGICFX®FX-SWITCHPACK works with 1 safety address and 4 sequential
addresses. The Safety address cannot be the same as one of the sequential addresses.
Operating the addresses in sequence mode results in the following:
Safety address
0 99 Device disabled
100 155 Device enabled
156 255 Device disabled
Start address 0 199 Output 1 disabled
200 255 Output 1 enabled
Start address + 1 0 199 Output 2 disabled
200 255 Output 2 enabled
Start address + 2 0 199 Output 3 disabled
200 255 Output 3 enabled
Start address + 3 0 199 Output 4 disabled
200 255 Output 4 enabled
Operation of OPreation of the Operation of the DMX addresses
Make sure the outputs are deactivated before activating the safety address. The
safety address cannot be activated when one or more outputs are activated.
When you link multiple machines with DMX, we advise you to use the same Safety address for all
machines.
Always plug in a DMX Terminator into the DMX output of the nal unit in the
control sequence. Using a DMX Terminator improves signal reliability.