CSV-20 Series
© 2015 Magnaflux
Page 3 Magnaflux-SRVC-IG018
Issued: Apr 2015
Rev. 2
Electrical Input:
Input Volts AC Phase
Full Load
(Amps)
Recommended
Line Fuse (Amps)
Recommended
Wire Size (AWG)
208 N/A N/A N/A **
230 N/A N/A N/A **
380 3500 400 **
415 3450 350 **
460 3400 300 **
575 3325 250 **
Duty Cycle:
At full output: 0.5 seconds “ON” – 20 seconds “OFF”
The equipment can be fused based on less than the maximum amperage draw due to the duty
cycle. Refer to NEC Code Section 630.31 Ampacity of Supply Conductors and Table 630.31
(A) (2) Duty Cycle Multiplication Factors for Resistance Welders (NPFA National Electric Code
2011). Some areas refer to 2 phase instead of 1 phase. The incoming power goes directly to
an isolation transformer so the unit will operate identically on 1 or 2 phase power.
Note: To obtain full rated output the following conditions must be met:
1. Two (2) thirty foot (30’) lengths of 1000 MCM cable connected in parallel and attached to
each of the Output Lugs on the front of the unit. If Output 2 and/or 3 are not used — No
need to hookup cables to that output.
2. A power source of the proper voltage, frequency and phase (as designated on the Mag-
naflux Data Plate) capable of providing current per the nameplate for the power pack. It is
highly recommended that an electrical fused disconnect be installed either on the wall be-
hind the unit or on a pedestal near the unit.