Magnetic MPT-353 User manual

Descripon
Full Height Turnsle
MPT-333 and MPT 353
MGC Control Unit
Doc. ID: 5817,0027EN
Version 01

2
MGC Control Unit
MAGNETIC AUTOCONTROL GMBH
Grienmatt 20
79650 Schopfheim
Deutschland
Telefon +49 7622 695 5
Fax +49 7622 695 802
www.magnetic-access.com

3
MGC Control Unit
Contents
Contents
1 Notes on the document 5
1.1 Purpose and contents of this descripon 5
1.2 Symbols and illustraons used in this document 6
1.2.1 Warning notes and notes 6
1.3 Target group 7
1.3.1 Personnel – acvies and qualicaons 7
2 Digital inputs, digital outputs and relay outputs 8
2.1 Digital inputs 8
2.2 Digital outputs and relay outputs 10
2.3 Digital power outputs of the MFM01 plug-in modules 12
3 Parameterising control unit 13
3.1 Changing menu language 13
3.2 Entering password 16
3.3 Control unit elements 17
3.4 Displays of the control unit 18
3.5 Symbols in the display 19
3.5.1 Control buon funcons 19
3.5.2 Further symbols 20
3.6 Seng display contrast 20
3.7 Protecng parameterisaon from access 21
3.8 Parameterise value 21
3.9 Switching the “Service” mode on and o 22
4 Descripon of menus and parameters 23
4.1 Menu “Informaon” 23
4.2 Menu “Sengs” 24
4.2.1 Hold-open me 24
4.2.2 Permanent open 24
4.2.3 Interlock 25
4.2.4 Vend count 26
4.2.5 Signalling 26
4.2.6 Random check funcon 28

4
MGC Control Unit
Contents
4.3 Menu “In-/Outputs” 30
4.3.1 Inputs 30
4.3.2 Outputs 30
4.4 Menu “Service” 31
4.4.1 Gate HW 31
4.4.2 Further parameters 34
4.5 Menu “System” 34
4.6 Menu “Passage counter” 35
4.7 Menu “Informaon” 35
4.8 Menu “Factory sengs” 36
5 Funcon descripon 38
5.1 Versions and denions 38
5.1.1 Denons and version MPT-353 40
5.2 Funcon sequence 42
5.3 Start-up and regular movement sequence 43
5.4 Operaon modes 43
5.4.1 Pulse operaon in both direcons without vend count 43
5.4.2 Pulse operaon in both direcons with vend count 44
5.4.3 Permanent open in both direcons 44
5.4.4 Pulse operaon in one direcon, permanent open in the
other direcon 44
5.5 Emergency 45
5.6 Random check funcon 45
6 Correcve acon 46
6.1 Safety in troubleshoong 46
6.2 Malfuncons turnsle 47
6.3 Event, warning and error messages in the display 47
6.3.1 Event, warning and error messages – logic control (control
unit) 48
6.3.2 Event, warning and error messages – all modules 49
6.4 Perform reset 49
7 Menu setup 50
Index 53

5
MGC Control Unit
Notes on the document
1 Notes on the document
1.1 Purpose and contents of this descripon
This document describes the MGC control unit from the program versions listed
below.
Soware number (Soware #) and soware version (SW version) are displayed in
the menu “Module info”.
Designaon Soware # SW version
Gate Controller 4915.1006 1.1
Table 1: Programme versions MGC control unit
IMPORTANT!
For informaon on design and funcon, for technical data, installaon
and assembly, electrical connecon, commissioning and cleaning and
maintenance, see the separate operang instrucons "Full height
turnsle MPT-333 and MPT-353 (Doc.ID: 5817,0028)".

6
MGC Control Unit
Notes on the document
1.2 Symbols and illustraons used in this document
1.2.1 Warning notes and notes
Warning notes are characterised by pictograms in these operang instrucons. A
warning note starts with a signal word that expresses the extent of the hazard.
It is absolutely essenal to observe the warning notes and to proceed with cauon
in order to prevent accidents as well as bodily injuries and property damage.
Warning Notes
DANGER
The signal word DANGER points to an immediately dangerous
situaon, which leads to death or severe injuries if it is not avoided.
WARNING
The signal word WARNING points to a potenally dangerous situaon,
which can lead to death or severe injuries if it is not avoided.
CAUTION
The signal word CAUTION points to a potenally dangerous situaon,
which can lead to minor injuries if it is not avoided.
NOTICE
The signal word NOTICE points to a potenally harmful situaon,
which leads to property damage if it is not avoided.
Notes and recommendaons
IMPORTANT!
The signal word IMPORTANT highlights useful notes and
recommendaons as well as informaon for an ecient and trouble-
free operaon.

7
MGC Control Unit
Notes on the document
1.3 Target group
1.3.1 Personnel – acvies and qualicaons
All work on the control unit may only be carried out by technicians and electricians
with the following qualicaons.
Designaon Qualicaon
Technician › Has completed training as a plant mechanic, plant er,
assembly mechanic, assembly er or has a comparable
technical educaon.
› Has completed training as an electrical safety expert.
› Has addional knowledge and experience.
› Knows the associated technical terms and regulaons.
› Can assess the work assigned to her/him, recognises
possible dangers and take suitable safety measures.
Electrical specialist › Has technical training which entles him to carry out and
monitor electrical work for commercial purposes.
› Has addional knowledge and experience.
› Knows the associated technical terms and regulaons.
› Can assess the work assigned to her/him, recognises
possible dangers and take suitable safety measures.
Table 2: Qualicaon of the personnel – MGC control unit

8
MGC Control Unit
Digital inputs, digital outputs and relay outputs
2 Digital inputs, digital outputs and relay outputs
WARNING
Improper wiring and parameterisaon of the control unit!
Improper wiring and parameterisaon of the control unit can lead to
undesired funcons and thus to injuries.
› Only qualied electricians or technician with addional "electrical
safety expert" training may wire and parameterise the control unit.
› The electrical connecon of the signal transmiers to the IN1 to IN8
inputs must t the parameterisaon.
Parameterisaon: äPage 13, Chapter 3.
2.1 Digital inputs
Denion “Entry” and “Exit”: äPage 38, Chapter 5.1.
By parameterising the inputs, you assign certain funcons to the inputs. For
example, if you parameterise the “Over-climb detecon” funcon for input IN7, you
must connect a sensor for the over-climb detecon to this input.
If the funcon is marked with “|”, the input is inverted (Fail Safe).
The following funcons are assigned to the inputs as default sengs.
Clamp Descripon Funcon
IN1 Digital Input 1 | Emergency open
IN2 Digital Input 2 Open entry
IN3 Digital Input 3 Open exit
IN4 Digital Input 4 Random check funcon
IN5 Digital Input 5 Conrm warnings
IN6 Digital Input 6 Inhibit opening
IN7 Digital Input 7 Sensor B1
IN8 Digital Input 8 Sensor B2
Table 3: Factory sengs “Digital inputs”

9
MGC Control Unit
Digital inputs, digital outputs and relay outputs
Clamp Funcon
–Inputs that you assign this funcon "–" to are being deacvated.
| Emergency open Emergency situaon (Fail Safe)
Connect re service switches, emergency opening contacts, etc. to this input.
This input has the highest priority. As soon as +24 V DC are applied to this
input, the pedestrian gate is in operaon.
If there is no signal at this entry, the passage is cleared in both direcons.
This input funcon is high priority to all other input funcons.
Conrm warnings Conrm warnings
A pulse at this input conrms the "Warning" output funcon. The output is
reacvated the next me a warning occurs.
The number of the warning message remains stored in the event list unl
the control unit is restarted.
Open entry Opening pulse for the passage from the zone not controlled (ZNC) to the
zone controlled (ZC)
If the signal is present for longer than 3 seconds, Permanent open is
acvated. äPage 28, Chapter 4.2.6, parameter "Permanent open".
Open exit Opening pulse for the passage from the zone controlled (ZC) to the zone not
controlled (ZNC)
If the signal is present for longer than 3 seconds, Permanent open is
acvated. äPage 28, Chapter 4.2.6, parameter "Permanent open".
Inhibit opening Lock pedestrian gate
Use this input to lock the pedestrian gate in both passage direcons. No
opening signals are accepted anymore. Input IN1 "| Emergency open"
remains superordinated. This means that the pedestrian gate can also be
opened via input IN1 when the pedestrian gate is locked.
Random check funcon Acvate random funcon, conrm hits
As soon as +24 V DC are applied to this input, the random funcon is
acvated. If a hit is generated, the hit can be conrmed with a 0 V pulse via
this input.
For this entry to be eecve, you must select the opon "Counng" or
"Random" for the parameter "Mode" in the "Random check funcon" menu.
äPage 28, Chapter 4.2.6, "Random check funcon" menu.
Sensor B1 (internal use) Connecon proximity sensor B1
Sensor B1 is connected to this entry by default. The inducve proximity
sensor is used to detect the end posions.
Sensor B2 (internal use) Connecon proximity sensor B2
Sensor B2 is connected to this entry by default. The inducve proximity
sensor is used to detect the end posions.
Table 4: Funcon digital inputs

10
MGC Control Unit
Digital inputs, digital outputs and relay outputs
2.2 Digital outputs and relay outputs
Denion “Entry” and “Exit”: äPage 38, Chapter 5.1.
By parameterising the outputs, you assign certain funcons to the outputs.
If the funcon is marked with “|”, the output is inverted (Fail Safe).
The following funcons are assigned to the outputs as default sengs.
Clamp Descripon Funcon
DO1 Digital output 1 GED red entry
DO2 Digital output 2 GED green entry
DO3 Digital output 3 GED red exit
DO4 Digital output 4 GED green exit
NO1 Relay output 1 Passage pulse entry
NO2 Relay output 2 Passage pulse exit
NO3 Relay output 3 –
NO4/NC4 Relay output 4 Passage free entry
NO5/NC6 Relay output 5 Passage free exit
NO6/NC6 Relay output 6 Random hit
Table 5: Factory sengs Digital outputs and Relay outputs
Funcon Funcon
–Outputs that you assign this funcon "–" to are deacvated.
| Error When the control unit recognises any safety-relevant error or error, the
output with this funcon is deacvated (Fail safe). äPage 47, Chapter 6.3.
| Warning When the control unit recognises any Warning, the output with this funcon
is deacvated (Fail safe). äPage 47, Chapter 6.3.
Gate ready Pedestrian gate is ready for operaon
This output is acvated as soon and as long as the pedestrian gate is ready
for operaon.
Passage pulse entry Counng pulse for the passage from the zone not controlled (ZNC) to the
zone controlled (ZC)
When the next end posion is reached in the zone controlled direcon, a
counng pulse (300 ms) is emied via this output. A counng pulse is also
emied in the "Permanent open" operang mode.
Passage pulse exit Counng pulse for the passage from the zone controlled (ZC) to the zone not
controlled (ZNC)
When the next end posion is reached in the zone not controlled direcon,
a counng pulse (300 ms) is emied via this output. A counng pulse is also
emied in the "Permanent open" operang mode.

11
MGC Control Unit
Digital inputs, digital outputs and relay outputs
Funcon Funcon
Passage free entry Control of display "Passage in zone controlled direcon cleared"
When the passage in the zone controlled direcon is cleared, a permanent
signal is emied via this exit. This exit may also be used to block a pulse
encoder such as a card reader for the opposite direcon. The request
generator must be equipped with a lock input for this.
Passage free exit Control of display "Passage in zone not controlled direcon cleared"
When the passage in the zone not controlled direcon is cleared, a
permanent signal is emied via this output. This exit may also be used to
block a pulse encoder such as a card reader for the opposite direcon. The
request generator must be equipped with a lock input for this.
Buzzer/Siren (alarm) Acousc signal transmier
This output is used to connect a signal transmier.
Random hit Hits of the random funcon, signal transmier
The random funcon generated a hit. You can connect a signal lamp or a
siren to this output, for example.
The passage remains blocked unl the random hit / validaon is conrmed
with a 0 V pulse at the "Random check funcon" input.
Service mode acve Pedestrian gate in service mode
As soon as the service mode is switched on via the slider on the control unit
MGC, this output is acvated.
GED red entry Gate End Display connecon
Connect the GED "red" of the zone not controlled to this output.
GED green entry Gate End Display connecon
Connect the GED "green" of the zone not controlled to this output.
GED red exit Gate End Display connecon
Connect the GED "red" of the zone controlled to this output.
GED green exit Gate End Display connecon
Connect the GED "green" of the zone controlled to this output.
Magnet RL1 (internal use) Connecon magnet RL1
Magnet RL1 for locking is connected to this exit by default. The magnet locks
in passage direcon le.
Magnet RL2 (internal use) Connecon magnet RL2
Magnet RL2 for locking is connected to this exit by default. The magnet locks
in passage direcon right.
Table 6: Funcon digital outputs and relay outputs

12
MGC Control Unit
Digital inputs, digital outputs and relay outputs
2.3 Digital power outputs of the MFM01 plug-in modules
The control unit is equipped with the plug-in module MFM01 with the funcon
“Magnets for locking”.
Furthermore, the control unit can be equipped with addional plug-in modules
MFM01.
Power outputs 60 V / 3 A are available via the oponal MFM01 plug-in modules. The
funcon is permanently assigned via the slot number.
Mag00838
21
3
4
5
Fig. 1: Slot numbers
Slot number Terminal
plug-in
module
LED plug-in
module
Funcon
1 Magnets for locking
1Red Magnet RL1
2 Green Magnet RL2
3Yellow –
2On-site signalling, e.g. lights for zone controlled (ZC)
1 Green Free in zone not controlled direcon
2Red Locked in zone not controlled direcon
3Yellow –
3On-site signalling, e.g. lights for zone not controlled (ZNC)
1 Green Free in zone controlled direcon
2Red Locked in zone controlled direcon
3Yellow –
4 –
5 –
Table 7: Funcons for MFM01 plug-in modules

13
MGC Control Unit
Parameterising control unit
3 Parameterising control unit
3.1 Changing menu language
The default seng in the MGC control unit is the menu language “English”.
Change the menu language as follows:
The operaonal view is displayed.
Mag00859
10
FlowMotion MPT333
1
0
– –
– –
Fig. 2: Example "Operaonal view”
1. Press right operang buon « ».
2. Access to parameterisaon can be password-protected. If password protecon
was acvated, you are asked to enter a password.
Mag00818
–––
0
Password
Fig. 3: View "Enter password"
3. The “Main menu” menu is displayed. The “Sengs” menu has a dark
background and is thus selected.
Mag00819a
Settings
In-/Outputs
Service
System
Main menu
Fig. 4: View "Main menu – Sengs"

14
MGC Control Unit
Parameterising control unit
4. Select the menu "System" with the two middle buons « », « ».
Mag00820a
Settings
In-/Outputs
Service
System
Main menu
Fig. 5: View "Main menu – System"
5. Conrm selecon with the right control buon « ». The following view is
displayed. The menu "Language" is chosen.
Mag00821
Language
Date/Time
System
Fig. 6: View "Language"
6. Conrm selecon with the right buon « ». The following view is displayed.
The menu language "English" is chosen.
Spanish
French
Mag00822
English
Language
Fig. 7: View "Language – English"
7. Select the language "German" with the two middle buons « », « ». The
language "German" has a dark background.
French
Mag00823
German
English
Language
Fig. 8: View "Language – German"

15
MGC Control Unit
Parameterising control unit
8. Use the right buon « » to select the new menu language. Your selecon is
marked with the symbol « ».
French
Mag00824
German
English
Language
Fig. 9: View "Language – German, step 2"
9. Use the le buon « » to leave the "Language" menu. The safety prompt
"Save changes?" appears.
Mag00825
Save changes?
Language ?
Fig. 10: View "Safety prompt – Save changes?"
Push the le buon « » if you do not want to save the changes. The menu
language "English" remains acve.
10. Conrm safety prompt with the right buon « ». The new menu language
"German" is acvated. The following view is displayed:
Mag00821
Sprache
Datum/Zeit
System
Fig. 11: View "Menu System – Menu language "German" is acvated
11. Press the le buon « » repeatedly unl the operang view is displayed
again. äPage 13, Fig. 2.

16
MGC Control Unit
Parameterising control unit
3.2 Entering password
You need to enter a password in the following cases:
› You would like to change parameters in the control unit and the password
protecon was acvated.
› You would like to reset the parameters to factory sengs.
If a password is required, the following view is displayed:
Mag00818
–––
0
Password
Fig. 12: View "Password"
1. Use the two middle buons « », « » to enter the rst digit of the password.
2. Use the right buon « » to select the second digit of the password. The
following view is displayed:
Mag00828
––
*0
Password
Fig. 13: View "Enter second digit of the password"
3. Use the two middle buons « », « » to enter the second digit of the
password.
4. Use the right buon « » to select the third digit of the password.
5. Use the two middle buons « », « » to enter the third digit of the password.

17
MGC Control Unit
Parameterising control unit
6. Use the right buon « » to select the fourth digit of the password. The
following view is displayed:
Mag00829
*0
**
Password
Fig. 14: View "Enter fourth digit of the password"
7. Use the two middle buons « », « » to enter the fourth digit of the
password.
8. Conrm the password with the right control buon « ».
3.3 Control unit elements
Mag00827a
1
3
2
Settings
In-/Outputs
Service
System
Main menu
Fig. 15: Control unit elements MGC
1 Menu
2 Current funcon of the 4 control buons
3 Control buons

18
MGC Control Unit
Parameterising control unit
3.4 Displays of the control unit
Mag00860
10
FlowMotion MPT333
1
0
– –
– –
6
3
4
1
2
57
9
8
10
Fig. 16: Example "Operaonal view"
1 Type pedestrian gate here MPT-333 electromove
2 Status display, here ready for operaon
3 Angle of rotaon, here 0
4 Current funcon of the right control buon, here calling menu "Main menu"
5 Validaons exit, here locked
6 Hold-open me exit, here locked
7 Operang display, here passage direcon le enabled
8 Current funcon of the le control buon, here calling menu "Informaon"
9 Holding-open me entry, here 10
10 Validaons entry, here 1
Mag00830
5
3
4
60
3
15 sek
1 2
Hold-open time
Fig. 17: Example "Screen Change value"
1 Parameter
2 Current value
3 Possible upper value
4 Possible lower value
5 Current funcons of the control buons

19
MGC Control Unit
Parameterising control unit
3.5 Symbols in the display
3.5.1 Control buon funcons
The control unit is equipped with 4 control buons. The funcon of the control
buons change depending on the current view in the display. The current funcons
are shown in the display.
Clamp Descripon
› Call menu "Informaon".
› Scroll menu "Informaon".
Call menu "Main menu". Make all sengs in the menu "Main menu".
Leave current menu level. The next-higher menu level is displayed.
› Call next-lower menu level.
› Select desired opon or desired value. When the desired opon
was selected, the symbol is displayed.
Opon was selected but not yet stored
› Within one menu level: Move cursor (market) upwards.
› For seng value: Increase gure.
› Within one menu level: Move cursor (market) downwards.
› For seng value: Decrease gure.
Move cursor one posion to the right.
› Delete error message.
› When changing sengs: Cancel changing process.
Table 8: Control buon funcons

20
MGC Control Unit
Parameterising control unit
3.5.2 Further symbols
Clamp Descripon
Wrong password entered. Access denied.
Reset values to factory sengs. To do this, you must enter the
password "0000".
The next validaon is blocked by the random funcon.
There is informaon. Check the "Informaon" menu. To do this, press
the le operang buon.
There is a warning. Check the "Informaon" menu. To do this, press
the le operang buon.
There is an error. Check the "Informaon" menu. To do this, press the
le operang buon.
The passage in zone controlled direcon cleared is cleared.
The passage in zone not controlled direcon cleared is cleared.
The passage is enabled in both direcons.
Table 9: Further symbols
3.6 Seng display contrast
The display contrast of the control unit is adjustable aer acvaon while the logo is
sll displayed. The logo is displayed for 3 seconds.
If you push one of the middle buons « », « », the display me of the logo
extends by 2 seconds per push. You can thus extend the me to set the display
contrast.
› Increase contrast, display grows darker: Press the « » buon.
› Reduce contrast, display grows lighter: Press the « » buon.
The set display contrast is saved automacally.