Technical Specifications
• TEMPERATURE MEASURING RANGE: -50-99°C (-58-210°F)
• ACCURACY: +/- 1°C (-50-70°C OR -58-158°F)
• POWER SUPPLY: 220V AC +/- 10%, 50/60Hz
• SENSOR: NTC Sensor
• RELAY CONTACT CAPACITY: Cooling (10A/250V AC), Heat (10A/250V AC)
• AMBIENT TEMPERATURE: 0 – 50°C (32 - 122°F)
Safety Specifications
• Make sure the Dual Temperature Controller is used on a flat dry surface.
• Do not plug any device into the sockets on the back that exceed the
power ratings.
• Avoid getting water and dust into the air vents on the side of the Dual
Temperature Controller.
• Always use the controller with the specified power ratings.
• Do not operate if the cord, plug or appliance is damaged.
• Do not let cord hang over the edge of a table or touch hot surface.
• Do not place on or near a hot gas or electric burner, or in a heated oven.
MANGROVE JACK’S DUAL TEMPERATURE CONTROLLER

Basic Operation
Power button
Up button
Down button
Set button
MANGROVE JACK’S DUAL TEMPERATURE CONTROLLER
Setting a Temperature
1. Press the Set button and hold for 3 seconds. The Set indicator light
on the screen will appear.
2. Press Set button again. The temperature displayed on the screen
now is the target temperature.
3. While holding in the Set button, use the Up or Down buttons to enter
a desired target temperature.
4. Once you reach your desired target temperature, press the Power button
to set that temperature. You will then return back to the main screen.
The temperature displayed on the screen under normal working
status shows the current temperature.
Button Press Once Hold for 3 Seconds Holding Continuously
Power Switch controller on and o.
Set Select, or finish step. Indicator light will
appear.
Hold the Set button and
pressing either the up or down
to enter target temperature.
Up Display target temperature.
Down Display the hysteresis value.

MANGROVE JACK’S DUAL TEMPERATURE CONTROLLER
Heating
The heat socket on the controller is for plugging a heating device
into. Most common is the Mangrove Jack’s Heat Belt or Heat Pad.
Cooling
The cooling socket on the controller is for plugging a fridge or
chiller into.
Temperature Probe
Insert the temperature probe into a fridge or temperature controller
box. If using a fridge it is best to read the temperature from the
middle of the fridge to get the most accurate reading of the
temperature inside.
Cooling
Thermometer
Power Cord
Heating

MANGROVE JACK’S DUAL TEMPERATURE CONTROLLER
Additional Settings
Apart from setting a target temperature (code F1), we recommend
keeping all other settings as their defaults. However, for your reference,
a complete list of the settings that you can change are described in the
table below:
To change settings other than setting a target temperature (F1):
1. Press the set button and hold for 3 seconds. The Set indicator light
on the screen will appear. The screen should also display “F1.”
2. Use the Up or Down buttons to select the code corresponding to the
setting of the function you would like to change.
3. While holding in the Set button, use the Up or Down buttons to enter
the desired value for that function.
4. Once you reach your desired target value, press the Power button to
set that value.
Code Function Default
F1 Setting a target temperature 10ºC
F2 Temperature hysteresis value 0.5ºC
F3 Cooling delay time (for compressor delay protection) 3 minutes
F4 Temperature calibration 0ºC

How do I change the temperature hysteresis value?
1. Press the set button and hold for 3 seconds. The Set indicator light on the
screen will appear.
2. Use the Up or Down buttons to select F2, the code corresponding to
temperature hysteresis value.
3. While holding in the Set button, use the Up or Down buttons to enter the
desired value.
4. Once you reach your desired target value, press the Power button to set
that value.
The cooling does not switch on immediately when the measured temperature
increases above the target temperature + hysteresis value. Is this normal?
The controller has been set to a default cooling delay time of 3 minutes. During
this delay time the Cool indicator light should be flashing. If the delay time you
experience is greater than 3 minutes, then this setting has likely been changed
from its default. To change the cooling delay time back to 3 minutes:
1. Press the set button and hold for 3 seconds. The Set indicator light on the
screen will appear.
2. Use the Up or Down buttons to select F3, the code corresponding to cooling
delay time.
3. While holding in the Set button, use the Up or Down buttons to select 3.
4. Press the Power button to set that value.
My controller does not display the correct temperature. How do I fix this?
The most likely cause for this is that the temperature calibration setting has
been changed from its default value of 0 ºC. To change this back:
1. Press the set button and hold for 3 seconds. The Set indicator light on the
screen will appear.
2. Use the Up or Down buttons to select F4, the code corresponding to
temperature calibration.
3. While holding in the Set button, use the Up or Down buttons to select 0.0.
4. Press the Power button to set that value.
Additional FAQs

NZ/AU: EU/UK:
Correct disposal of this product:
This marking indicates that this product should not be
disposed with other household wastes throughout the
EU. To prevent possible harm to the environment or
human health from uncontrolled waste disposal, recycle it
responsibly to promote the sustainable reuse of material
resources. To return your used device, please use the
return and collection systems or contact the retailer where
the product was purchased. They can take this product for
environmental safe recycling.
Product name: Dual Temperature Controller
Model number: 71140
Voltage: 220-240V ~ 50/60Hz
Made in: China
Product name: Dual Temperature Controller
Model number: 71141 (EU) and 71142 (UK)
Voltage: 220-240V ~ 50/60Hz
Made in: China

VERSION: 2WWW.MANGROVEJACKS.COM
Table of contents
Popular Controllers manuals by other brands

Panasonic
Panasonic FP7 Series Additional Functions Manual

Ikan
Ikan OTT-CONTROLLER manual

Enttec
Enttec S-PLAY user manual

RKC INSTRUMENT
RKC INSTRUMENT CB103 installation manual

Johnson Controls
Johnson Controls RRS Economizer Controller quick start guide

FXLuminaire
FXLuminaire Luxor Owner's manual and installation instructions