How do I change the temperature hysteresis value?
1. Press the set button and hold for 3 seconds. The Set indicator light on the
screen will appear.
2. Use the Up or Down buttons to select F2, the code corresponding to
temperature hysteresis value.
3. While holding in the Set button, use the Up or Down buttons to enter the
desired value.
4. Once you reach your desired target value, press the Power button to set
that value.
The cooling does not switch on immediately when the measured temperature
increases above the target temperature + hysteresis value. Is this normal?
The controller has been set to a default cooling delay time of 3 minutes. During
this delay time the Cool indicator light should be flashing. If the delay time you
experience is greater than 3 minutes, then this setting has likely been changed
from its default. To change the cooling delay time back to 3 minutes:
1. Press the set button and hold for 3 seconds. The Set indicator light on the
screen will appear.
2. Use the Up or Down buttons to select F3, the code corresponding to cooling
delay time.
3. While holding in the Set button, use the Up or Down buttons to select 3.
4. Press the Power button to set that value.
My controller does not display the correct temperature. How do I fix this?
The most likely cause for this is that the temperature calibration setting has
been changed from its default value of 0 ºC. To change this back:
1. Press the set button and hold for 3 seconds. The Set indicator light on the
screen will appear.
2. Use the Up or Down buttons to select F4, the code corresponding to
temperature calibration.
3. While holding in the Set button, use the Up or Down buttons to select 0.0.
4. Press the Power button to set that value.
Additional FAQs