TROUBLE S OOTING
PROBLEM:
Crimper does not cycle when plunger
switch or foot pedal is actuated.
Crimper cycles continuously or more
than once when plunger switch or foot
pedal is actuated.
SOLUTION:
1.) Check power cord and power switch
Make sure the power cords
connected to the crimper and
plugged into wall outlet. Verify that
the power switch is in the on
position.
2.) Check panel mounted fuse on back of
crimper. Reset fuse if tripped by
pushing it back into place.
3.) Check building power at breaker
panel or confirm power at wall outlet
with a different machine or
appliance.
1.) Internal micro-switch on cam is out
of adjustment. Call for technical
assistance or have a qualified service
person check the micro-switch.
WARNING:
The top cover of your Marlon 200 should only be removed by a qualified service
technician with the power off and the machine unplugged. This cover should never
be removed by a machine operator, and must be fastened in place at all times when
crimper is in use.