manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. MARTINDALE
  6. •
  7. Measuring Instrument
  8. •
  9. MARTINDALE CT60 User manual

MARTINDALE CT60 User manual

Other MARTINDALE Measuring Instrument manuals

MARTINDALE LM82 User manual

MARTINDALE

MARTINDALE LM82 User manual

MARTINDALE RT80 User manual

MARTINDALE

MARTINDALE RT80 User manual

MARTINDALE LM195 User manual

MARTINDALE

MARTINDALE LM195 User manual

MARTINDALE CM87 User manual

MARTINDALE

MARTINDALE CM87 User manual

MARTINDALE CB12 User manual

MARTINDALE

MARTINDALE CB12 User manual

MARTINDALE DH85 User manual

MARTINDALE

MARTINDALE DH85 User manual

MARTINDALE CM69 User manual

MARTINDALE

MARTINDALE CM69 User manual

MARTINDALE LM192 User manual

MARTINDALE

MARTINDALE LM192 User manual

MARTINDALE VR2230 Operator's manual

MARTINDALE

MARTINDALE VR2230 Operator's manual

MARTINDALE CM82 User manual

MARTINDALE

MARTINDALE CM82 User manual

MARTINDALE PSI4000 User manual

MARTINDALE

MARTINDALE PSI4000 User manual

MARTINDALE LM90 User manual

MARTINDALE

MARTINDALE LM90 User manual

MARTINDALE PD430 User manual

MARTINDALE

MARTINDALE PD430 User manual

MARTINDALE SP75 User manual

MARTINDALE

MARTINDALE SP75 User manual

MARTINDALE AV85 User manual

MARTINDALE

MARTINDALE AV85 User manual

MARTINDALE VIPD138 User manual

MARTINDALE

MARTINDALE VIPD138 User manual

MARTINDALE CM58 User manual

MARTINDALE

MARTINDALE CM58 User manual

MARTINDALE PM85 User manual

MARTINDALE

MARTINDALE PM85 User manual

MARTINDALE FD650/R User manual

MARTINDALE

MARTINDALE FD650/R User manual

MARTINDALE VR2250 Operator's manual

MARTINDALE

MARTINDALE VR2250 Operator's manual

MARTINDALE CO190 User manual

MARTINDALE

MARTINDALE CO190 User manual

MARTINDALE CMi210 User manual

MARTINDALE

MARTINDALE CMi210 User manual

MARTINDALE FD500 User manual

MARTINDALE

MARTINDALE FD500 User manual

MARTINDALE VI13800 User manual

MARTINDALE

MARTINDALE VI13800 User manual

Popular Measuring Instrument manuals by other brands

Powerfix Profi 278296 Operation and safety notes

Powerfix Profi

Powerfix Profi 278296 Operation and safety notes

Test Equipment Depot GVT-427B user manual

Test Equipment Depot

Test Equipment Depot GVT-427B user manual

Fieldpiece ACH Operator's manual

Fieldpiece

Fieldpiece ACH Operator's manual

FLYSURFER VIRON3 user manual

FLYSURFER

FLYSURFER VIRON3 user manual

GMW TG uni 1 operating manual

GMW

GMW TG uni 1 operating manual

Downeaster Wind & Weather Medallion Series instruction manual

Downeaster

Downeaster Wind & Weather Medallion Series instruction manual

Hanna Instruments HI96725C instruction manual

Hanna Instruments

Hanna Instruments HI96725C instruction manual

Nokeval KMR260 quick guide

Nokeval

Nokeval KMR260 quick guide

HOKUYO AUTOMATIC UBG-05LN instruction manual

HOKUYO AUTOMATIC

HOKUYO AUTOMATIC UBG-05LN instruction manual

Fluke 96000 Series Operator's manual

Fluke

Fluke 96000 Series Operator's manual

Test Products International SP565 user manual

Test Products International

Test Products International SP565 user manual

General Sleep Zmachine Insight+ DT-200 Service manual

General Sleep

General Sleep Zmachine Insight+ DT-200 Service manual

Sensa Core Lacto Spark user manual

Sensa Core

Sensa Core Lacto Spark user manual

VOLTCRAFT UTS-1980 operating instructions

VOLTCRAFT

VOLTCRAFT UTS-1980 operating instructions

EBCHQ 94915 Operation manual

EBCHQ

EBCHQ 94915 Operation manual

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Balluff

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Pulsar IMP Lite Series instruction manual

Pulsar

Pulsar IMP Lite Series instruction manual

ETCR 6800 user manual

ETCR

ETCR 6800 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

SPECIFICATIONS
General
Captured Conductor Size: 30mm maximum.
Low Battery Indicator: Red LED lighting.
Operating Temperature: 0° C to 50° C, Max 70% R.H.
Storage Temperature: -20° C to +70° C, Max 80% R.H.
Weight: 290gm typical
Dimensions: 178mm (H) x 70mm (W) x 33mm (D).
Electrical
Accuracy (At 23° ± 5° C, 70% R.H maximum)
DC Current: 0 to 600A, ± (2% reading + 2A)
AC current: 50Hz to 400Hz
0 to 400A, ± (2% reading + 2A)
400A to 500A, ± (3% reading + 2A)
500A to 600A, ± (6% reading + 2A)
Load Resistance: 10K Typical.
Output: 0 to 600mV (AC and DC) for 0 to 600A.Met
Metrohm House, Imperial Park, Imperial Way, Watford, Hertfordshire, WD24 4PP, UK
Tel: 01923 441717 Fax: 01923 446900.
Due to policy of continuous development, Martindale reserves the right to alter equipment specification and description
outlined in this document without prior notice. No part of this document shall be deemed to be part of any contract for the
equipment unless specifically referred to as an inclusion within such contract. © Martindale Electric Co. Ltd. 2000
CT60
AC/DC Current
Clamp
INSTRUCTION MANUAL
APPLICATION NOTES
1. In the case of DC current, the output is positive when the
current flows from the top to the underside of the clamp. The red
4mm plug is positive.
2. In the case of DC current measurement, a hysteresis effect
can occur so that it is impossible to zero the clamp properly. To
eliminate this effect, open and close the jaws several times and
then zero again.
3. When there is a strong stray magnetic field, it is best to zero
the clamp approximately 2 to 4 inches (50-100mm) away from
the conductor to be measured. The conductor itself will have no
influence at this distance. Then, clamp the jaws around the
conductor and measure the current.
4. A good tip for measuring low currents is to loop an
appropriate number of turns of the conductor through the jaws.
The actual current is the measured value divided by the number
of turns.
BATTERY REPLACEMENT
Remove the screw on the rear of the clamp, remove the battery,
and replace with a 9-volt battery, NEDA 1604/PP3.
INTRODUCTION
The model CT60 AC/DC Current Clamp is an accessory which
will allow your multimeter to measure electrical current up to 600
amperes AC/DC, with a frequency response up to 400Hz. When
measuring current with this clamp, there is no need to break a
circuit or to affect the isolation.
APPLICATION PROCEDURE
1. Insert the black 4mm plug into the COM jack and the red
4mm plug into the V- jack of any multimeter with a minimum input
impedance of 10KΩ.
2. Set the power switch from "Off" to "On" position, the green
LED will light to indicate that the clamp is switched on. For
current measurement below 20A, set the multimeter range to
200mV AC for AC current measurements or 200mV DC for DC
current measurements. The reading is directly in A. For current
measurements above 200A, set the multimeter range to 2V AC
or DC, depending on whether measuring AC or AC current. The
reading is now A x 1000.
3. Turn the zero adjustment knob on the clamp until the
multimeter reads zero.
4. Clamp the jaws around the current-carrying conductor and
interpret the reading according to Step 2 above. Ensure there is
only the conductor being measured inside the jaws. If you
attempt to measure around both Line & Neutral for example only
the difference will be measured - usually giving zero as the
result.