1www.mastercool.com
MINI-FOLD COMPACT MANIFOLD
INSTRUCTION MANUAL
• Anweisungen in deutscher sprache finden sie unter
www.mastercool.com
• Pour obtenir des instructions en français, veuillez visiter
www.mastercool.com
• Para obtener instrucciones en español, visite www.mastercool.com
• Para instruções em português favor visitar www.mastercool.com
• Ga voor instructies in het nederlands naar www.mastercool.com
SPECIFICATIONS
• Pressure Range:
Low Pressure Range: -14.5 – 500 psi
(-0.1 – 3.4 MPa)
High Pressure Range: -14.5 – 800 psi
(-0.1 – 5.5 MPa)
• Resolution: 0.5 psi
• Accuracy: +/-0.5% FS
• Measurement Units: MPA, kPa, bar, psi,
kg/cm2, inHg
• Temperature Unit: ˚C/˚F
• Over Range Alarm: Display -OL-
• Operating Temperature: -10˚C to 60˚C
• Battery: CR2450
• Battery Life: Approximately 6 months
• Sampling Rate: 1 second
• Low Battery Indication: icon on LCD
• Display: 30 mm x 17 mm LCD
• Blue Backlight: Auto-off after 6 seconds
INCLUDED REFRIGERANTS
R11, R113, R114, R115, R116, R12, R123, R1234yf, R1234ze, R124, R125, R13, R134a,
R14, R141B, R142B, R413A, R152A, R161, R170, R21, R218, R22, R23, R290, R32, R401A,
R401B, R401C, R402A, R402B, R403A, R403B, R404A, R406A, R407A, R407B, R407C,
R407D, R407E, R407F, R408A, R409A, R409B, R41, R410A, R410B, R412A, R413A, R414A,
R414B, R415B, R416A, R417A, R419A, R420A, R421A, R421B, R422A, R422B, R422C,
R422D, R423A, R427A, R437A, R441A, R442A, R443A, R444A, R448A, R449A, R449B,
R450A, R452A, R455A, R50, R500, R502, R503, R504, R507A, R508A, R508B, R509A,
R513A, R600, R600a, R601, R601a, R740, R744
WARNING!!
• Wear Safety Glasses / Wear Gloves
• If eyes come in contact with refrigerant, immediately flush with plenty of water.
Seek medical attention immediately.
• Keep the manifold in a dry place. Do not allow moisture to enter the unit.
• NOTE (R744): CO2 systems work under extremely high pressures. Only
professional technicians are recommended to service these systems. Please use
proper safety equipment while servicing.
DIGITAL GAUGE OPERATION
ON/OFF
• ON: Press
button and it will display current pressure
• OFF: Press and hold
button until the screen is off
BACKLIGHT
• When the gauge is ON, press
button to use backlight. The backlight will automati-
cally turn off after 6 seconds of inactivity.
MAX AND MIN MEMORY AND CLEAR
• Press
button to display MAX value and MAX symbol, then press the same button
again for 3 seconds to clear the current MAX value.
• Press
button to display MIN value and MIN symbol, then press the same button
again for 3 seconds to clear the current MIN value.
ZERO
• Press and hold
for 3 seconds until 8.8.8.8 shows on the screen, then release it to
clear the current value to O.
NOTE: Please zero the gauge before connecting it to the system.