manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. MayPole
  6. •
  7. Air Compressor
  8. •
  9. MayPole MP7951 User manual

MayPole MP7951 User manual

MP7951 12V Hand Held Air Compressor
www.maypole.ltd.uk
1
1. Trigger Switch 4. Tyre connector 7. 12V DC vehicle connector
2. Analogue dsiplay 5. Ball needle connector 8. Accessory holder
3. Hose with Quick coupler 6. Inflatables connector
Item No:
Voltage:
Rated
Current:
Power
Flow Rate:
Max.
Pressure:
Sound Pressure
Sound Power
MP7951
12V - DC
8A
100 Watt
12 l/min.
150 psi
<75.2 dB(A)
<95.2dB (A)
1. TECHNICAL SPECIFICATION
SECSPECIFICATIONS
2. PRODUCT SPECIFICATION
MP7951 12V Hand Held Air Compressor
www.maypole.ltd.uk
2
Your analogue compressor is designed to be used from the standard 12V dc socket in most vehicles, to inflate car and bike
tyres, balls, etc. This product is intended for household, consumer use only.
● Read all safety warnings and all instructions.
Save all warnings and instructions for future reference.
Work area safety
● Keep work area clean and well lit. Cluttered or dark areas
invite accidents.
● Do not operate compressor in explosive atmospheres, such
as in the presence of flammable liquids, gases or dust. Power
tools create sparks which may ignite the dust or fumes.
● Keep children and bystanders away while operating the
compressor. Distractions can cause you to lose control.
●The plug must match the outlet. Never modify the plug in
any way.
● Do not expose the compressor to rain or wet conditions.
Water entering the compressor will increase the risk of
damage.
● Do not use if the switch (1) does not turn the compressor
on and off.
● Disconnect the plug from the power source tool before
making any adjustments, changing accessories, or storing
power tools. Such preventive safety measures reduce the risk
of starting the power tool accidentally.
● Store compressor out of the reach of children and do not
allow persons unfamiliar with the compressor or these
instructions to operate the compressor.
● Always check the compressor before use. If damaged, or
worn, do not use.
Device-specific safety instructions
● This appliance may not be used by children or people with
reduced physical, sensory or mental capabilities or a lack of
experience and knowledge. Children must not use the
appliance as a plaything. Cleaning and user maintenance tasks
may not be carried out by children unless they are supervised.
● Avoid using the compressor at temperatures below +5
degrees.
● Never leave the compressor unsupervised while it is in use.
● Ensure that the ON/OFF switch is turned off when
connecting to the power supply.
● Caution! Operate the compressor only for a short time. The
appliance may overheat if operated continuously for longer
than 10 minutes. Switch the appliance off immediately and
allow it to cool down for at least 10 minutes.
● Risk of injury! Do not inflate any objects to more
than the intended pressure. They could burst and
cause injury and/or material damage.
● Do not exceed the permissible output range of the
compressor. Do not pump up any lorry, tractor or
other large tyres.
● Never use the appliance for purposes other than the
ones for which it was designed.
● The appliance must always be kept clean, dry and
free from oil or grease.
● Stay alert, watch what you are doing and use
common sense when operating a power tool. Do not
use a power tool while you are tired or under the
influence of drugs, alcohol or medication.
● Use personal protective equipment. The use of
personal protective equipment such as Eye protection
and hearing protection is recommended.
● Prevent unintentional starting. Ensure the switch is
in the off-position before connecting to power source,
picking up or carrying the tool.
● Remain alert at all times! Never use the appliance
when you are distracted or don’t feel well.
● Do not carry the appliance by the power cord and
never hang it up by the power cord. Always route the
power cord away from the appliance to the rear. Keep
cord away from heat, oil, sharp edges and moving
parts. Do not use if the cord is worn or damaged.
● The compressor and hoses can get very hot during
operation. Touching them can cause burns.
● When removing the quick coupler, always hold the
hose coupling fi rmly to avoid injury caused by the
hose flying off.
● The appliance vibrates during operation.
3. INTENDED USE
4. SAFETY
MP7951 12V Hand Held Air Compressor
www.maypole.ltd.uk
3
USE OF ACCESSORIES
Remove the required accessories from the accessory
compartment.
FITTING THE ACCESSORIES
Your inflator is supplied with the standard tapered nozzle,
Presta valve convertor and the needle inflator nozzle, these
are located in in clips on the body of the unit.
• To use the universal valve adaptor, make sure that the lever
is in the up position.
• Place the valve adapter over the stem of the inflation needle
or tapered nozzle.
• Press the lever on the valve adapter down to lock it in place.
• Place the inflation needle or tapered nozzle into the item to
be inflated.
WARNING: Never leave inflator running unattended, it
can burst car tyres and other items.
To use your inflator:
•Before use, check the manufacturers recommended tyre
pressures for the vehicle.
• Plug the 12Vdc vehicle connector into the vehicle accessory
socket. The LED light will be powered.
• Connect the quick coupler and an accessory if required, to
the item to be inflated, making sure that the lever of the
coupler is in the down position to lock it in place.
Note: Make sure that the Quick Coupler is correctly fitted
to the item to be inflated.
To start the inflator use the trigger switch.
To do this you must:
•Slide the Red section of the trigger upwards.
•Squeeze the trigger to start the compressor.
•Releasing the trigger will switch OFF the
compressor.
•To lock the ON /OFF switch in the ON position,
with the trigger still depressed, slide the Red
section downwards.
•To switch the compressor OFF from this
position, slide the Red section of the trigger
upwards and release he trigger.
• When the item is inflated as required or to stop the
inflator at any time release the trigger to the OFF
position as described above.
Note: You may notice the actual pressure reading may
drop after a couple of seconds, this is normal.
• Remove the quick coupler and/or accessory from the
inflated item and the 12 Volt connector from your
vehicle's 12 Volt accessory socket.
USING THE INFLATOR AS A PRESSURE GAUGE
• Connect the quick coupler to the item to be checked.
• The gauge will display the items pressure.
5. OPERATION
OPERATION
MP7951 12V Hand Held Air Compressor
www.maypole.ltd.uk
4
The only user serviceable part is a 10Amp fuse located I the 12V connector, this can be checked by unscrewing the spring
loaded centre pin from the plug. Only replace with a fuse with identical ratings. Make sure that the machine is not live when
carrying out maintenance work. Regularly clean the machine housing with a soft cloth, preferably after each use. Keep the
ventilation slots free from dust and dirt. If the dirt does not come off use a soft cloth moistened with soapy water. Never use
solvents such as petrol, alcohol, ammonia water, etc. These solvents may damage the plastic parts.
The machine requires no additional lubrication.
In order to prevent the machine from damage during transport, it is delivered in sturdy packaging. Most of the packaging
materials can be recycled. Take these materials to the appropriate recycling locations. Take your unwanted machines to your
local dealer. Here they will be disposed of in an environmentally safe way.
Discarded electric appliances are recyclable and should not be discarded in the domestic waste! Please actively support us in
conserving resources and protecting the environment by returning this appliance to the collection centres (if available).
DECLARATION OF CONFORMITY
We declare under our sole responsibility that this product is in conformity with the following standards or standardized documents:
EN1012-1:2010; EN60204-1:2006/A1:2009; EN55014-1:2006/A2:2011;EN55014-2:2015; EN61000-3-2:2014;EN61000-3-3:2013;
in accordance with the regulations 2006/42/ЕEС, 2014/30/ЕEС.
Technical Manager
Maypole Ltd Sept 2018
6. MAINTENANCE
7. ENVIRONMENTAL PROTECTION

Other MayPole Air Compressor manuals

MayPole MP7950 User manual

MayPole

MayPole MP7950 User manual

MayPole MP7949 User manual

MayPole

MayPole MP7949 User manual

MayPole MP7955 User manual

MayPole

MayPole MP7955 User manual

Popular Air Compressor manuals by other brands

Johnson Controls Frick RWF II Installation operation & maintenance

Johnson Controls

Johnson Controls Frick RWF II Installation operation & maintenance

WilTec AF18-2 Operation manual

WilTec

WilTec AF18-2 Operation manual

Sullivan-Palatek D185PIZP Operation & service manual

Sullivan-Palatek

Sullivan-Palatek D185PIZP Operation & service manual

Toolex Platinum Series instruction manual

Toolex

Toolex Platinum Series instruction manual

MasterCraft 299-1978-8 instruction manual

MasterCraft

MasterCraft 299-1978-8 instruction manual

WAGNER VKM592 Instruction and maintenance manual

WAGNER

WAGNER VKM592 Instruction and maintenance manual

Scheppach Air Force instruction manual

Scheppach

Scheppach Air Force instruction manual

Lincoln Electric IM581 Operator's manual

Lincoln Electric

Lincoln Electric IM581 Operator's manual

Gardner Denver VST55A Operating and service manual

Gardner Denver

Gardner Denver VST55A Operating and service manual

Ryobi R18I Series Original instructions

Ryobi

Ryobi R18I Series Original instructions

Wagan 2450 user manual

Wagan

Wagan 2450 user manual

Emerson VILTER VSG Installation, operation and service manual

Emerson

Emerson VILTER VSG Installation, operation and service manual

Ring Automotive RAC600 instructions

Ring Automotive

Ring Automotive RAC600 instructions

Craftsman 919.724110 owner's manual

Craftsman

Craftsman 919.724110 owner's manual

VIAIR VMS 444DB user manual

VIAIR

VIAIR VMS 444DB user manual

ABAC PRO A29B-0 150 CM3 Zero user manual

ABAC

ABAC PRO A29B-0 150 CM3 Zero user manual

Gardner Denver Compair Reavell 5236.2.IA Operator's handbook

Gardner Denver

Gardner Denver Compair Reavell 5236.2.IA Operator's handbook

Campbell Hausfeld Portable Air Compressor operating instructions

Campbell Hausfeld

Campbell Hausfeld Portable Air Compressor operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.