MedPro SONAIR User manual

1
Instructions
Read thoroughly before operating the nebulizer
Save these instructions for future reference
TM
ULTRASONIC MESH NEBULIZER
Generated by :
Special Instructions :
Projet :
Item No. : Part No. :
Colours :
B/W CMYK Spots:
Flat Size :
Assembled Size :
861-705460
12 x 10 cm Mireille Grondin
705-460 Sonair Nebulizer instructions
705-460

2

1
TABLE OF CONTENTS
Sonair Introduction....................................................................2
Safety Precautions .................................................................. 4
Parts and Components............................................................7
Preparing the Device............................................................... 8
Operating Instructions.............................................................10
Cleaning and Disinfecting...................................................... 13
Storage and Maintenance......................................................15
Troubleshooting..................................................................... 17
Device and Label Symbols .................................................... 19
Electromagnetic Compatibility ............................................... 20
Limited Warranty ................................................................... 25
Technical Specications ........................................................ 26

2
SONAIR INTRODUCTION
Thank you for purchasing the SonairTM Mesh Nebulizer.
By selecting this product, you have chosen a high quality,
innovative device.
Before using the Sonair Nebulizer for the rst time, please read
through this manual carefully. If you still have any questions
regarding its use, visit the A.M.G. Medical website or contact our
Customer Service team at 1-800-363-2381.
This device is intended for use in the treatment of respiratory
conditions. Mesh nebulizers use micro pump technology for
aerosol production. High frequency mesh nebulization of liquid
medication delivers ultra-ne mist permeating the lungs faster for
convenient and eective respiratory treatment.
Silent Nebulization
Rechargeable
Compact + Portable
One-Touch Operation
Nébulisation silencieuse
Rechargeable
Compact + Portable
Un seul bouton d’activation

3
SONAIR INTRODUCTION
The Sonair Nebulizer is an easy to use device with only
One-Touch Operation. This compact nebulizer is portable
allowing you the exibility to use at home or at work. Sonair’s
size also makes it perfect for travel, it can t into a brief case,
purse or backpack. Even more, Sonair is ultra-silent making it
convenient to use anywhere. The soundless operation of the
device enables discrete use with your medication within reach
wherever you go.
Silent Nebulization
Rechargeable
Compact + Portable
One-Touch Operation
Nébulisation silencieuse
Rechargeable
Compact + Portable
Un seul bouton d’activation
Silent Nebulization
Rechargeable
Compact + Portable
One-Touch Operation
Nébulisation silencieuse
Rechargeable
Compact + Portable
Un seul bouton d’activation

4
SAFETY PRECAUTIONS
DO NOT USE THE SONAIR NEBULIZER WITH: Pentamidine,
Pulmonary Edema Patients, Acute Asthma, and Acute Pulmonary
Infarction Episodes
• This nebulizer is a medical device. Only use medications as prescribed
and instructed by your healthcare professional.
• Only use the nebulizer for its intended purpose, for inhalation therapy.
Any other form of use constitutes an improper use and is therefore
dangerous.
• Clean and disinfect the medication cup and accessories before rst use.
• To reduce the risk of increased bacterial growth, infection, illness or
injury from contamination, thoroughly clean and dry all parts along
with accessories of any moisture or condensation at the end of
every treatment, following the instructions in this manual.
• Stop using the device if the components are damaged or fall into
water accidentally.
• The Nebulizer and all accessories are for single-patient use only.
Do not share device.
• Prior to use, make sure the device and accessories (e.g. mouthpiece
and mask) are correctly assembled as per this instruction manual.
Use of improperly assembled accessories could alter delivery of
medication, and therefore the eectiveness of treatment.

5
• Do not shake the nebulizer during operation.
• Do not drop the nebulizer.
• Never use in environments with high humidity (eg: bathroom)
• Never use in rooms where aerosols (sprays) are used or
pure oxygen is being administered. Do not use it near highly
ammable substances, gases or explosives.
• Do not use near shortwave or microwave therapy equipment.
• Do not use the nebulizer near a heating device or an open
ame. Do not use a microwave, oven, or fan to dry nebulizer
and accessories.
• Do not expose the nebulizer and accessories to corrosive
liquids and gases.
• Please use original parts and accessories.
• Keep the unit away from water. Do not immerse the unit in any
liquid. Do not use while bathing. Never operate the nebulizer if it
has any damaged parts or if it has been dropped or submersed
in water or other liquids.
SAFETY PRECAUTIONS

6
SAFETY PRECAUTIONS
• Never use liquids which contain ester, fatty or suspended particles.
Only use healthcare professional prescribed medications
for nebulizing.
• Close supervision is necessary when this product is used by or near
children and/or persons with special needs. Never use this unit when
sleeping or drowsy.
• This product contains small parts that may represent a choking
hazard for small children.
• Children under the age of 3, as well as any patient who is unable to
correctly use this unit with a mouthpiece under supervision, should
use a mask.
WARNING: Always ensure close adult supervision when
administering treatment to a child. Do not leave a child
unattended during treatment.

7
SONAIR PARTS AND COMPONENTS
7
10
8
9
4
1
2
3
5
6
1. Lid
2. Medication Cup
3. Spray Nozzle
4. Power Switch
5. Unit
6. Mini USB Port
7. Mouthpiece
8. Mask (2 included)
9. USB Cable
10. Accessory Bag

8
PREPARING THE DEVICE
1. Remove the unit and all accessories from package.When using
the Sonair Nebulizer for the rst time or after not using it for a
long period of time, remember to clean and disinfect the nebulizer
including the medication container, mesh metal, spray nozzle,
mask, and mouthpiece prior to use. Always keep nebulizer clean.
For details refer to the section - Cleaning and Disinfecting.
Note: Clean, disinfect, dry all parts before assembly.
2. Power Supply
Before use, charge your Sonair rechargeable lithium battery with
the enclosed USB cable. It can be plugged into a computer’s
USB port or into a wall socket using an adapter (not included) as
illustrated in Figure 1.
Figure 1
Charge time: 1.5 hours
Operation time: 60 Minutes (Approx.)
DC 5.0V/1.0A
Output Voltage

9
a b
Low Battery
When the blue indicator light ashes, charge the battery as soon
as possible. The indicator light will turn green during charging,
and will turn o when the unit is fully charged.
Note: Charge the Sonair Nebulizer at least once per month
even when not being used (in storage).
3. Insert the mouthpiece (a) or the mask (b) directly into
nebulizer nozzle, as illustrated.
PREPARING THE DEVICE

10
OPERATING INSTRUCTIONS
1. Wash hands with soap and warm water, then dry completely with
a clean towel.
2. Ensure that the medication cup and accessories have been
cleaned and / or disinfected before rst use, as well as after the
last treatment of the day. Refer to the cleaning and disinfecting
instructions in this manual.
3. Open the nebulizer cover (a-b), ll the nebulizer medication cup
with prescribed medication (c) and close the nebulizer cover (d) as
indicated in Figure 2.
Note: Do not exceed the maximum capacity of the medication
compartment. Please do not ll more than 10 ml per treatment.
abcd
Figure 2

11
4. Nebulization
1) Click power key to start nebulization
2) Hold the device so that the medication stays in contact with the
nebulization mesh.
3) If using the mouthpiece (a), bring it into mouth and close lips
slightly to facilitate nebulized medication owing deep into the
bronchial tubes.
4) If using a mask (b), place it over your mouth and nose as
illustrated and fasten the elastic strap around the back
of your head.
5) For direct inhalation (c), hold the device to ensure nebulized
medication intake near the mouth.
OPERATING INSTRUCTIONS
a b c

12
OPERATING INSTRUCTIONS
6) Inhale the liquid medication mist. Always be calm and relaxed
when you inhale. If you want to lay in bed for treatment, it is
suggested to put a pillow behind your back so that you can
keep the spine straight. Breathe in slowly and deeply so that the
nebulized medication can reach fully into the bronchial tubes.
7) Hold device to keep medication in contact with nebulizer mesh.
Do not shake device during treatment.
8) The nebulizer can be set for 10 minutes, and will then
automatically turn o. If you need to continue nebulization,
press the power key to complete your treatment.
9) After completion of treatment, close the device by pressing the
power key. If the power adapter is connected, unplug it from the
electrical outlet.
10) Remove the mouthpiece/mask.
11) Remove the residual medication from the nebulizer medication
cup and clean it along with all accessories (mask and mouthpiece).
See Figure 3 for “how to remove medication cup”.

13
The following items should be cleaned after each use: nebulizer
nozzle, medication cup, metal mesh in nebulizing head, mouthpiece
and mask.
1. Before cleaning, turn o the device by pressing the power key .
2. Remove all components including the mask, mouthpiece and
medication cup from the device. To remove the medication cup,
press the button on the back and lift the medication cup at the
same time. (Figure 3)
3. Wash and disinfect the nebulizer nozzle, medication cup, mask,
and mouthpiece with warm puried soapy water (Below 40°C) or
in medical disinfectant. DO NOT WASH THE MAIN UNIT.
CLEANING AND DISINFECTING
Figure 3

14
CLEANING AND DISINFECTING
4. Immediately after cleaning, dry the nozzle, medication cup and
accessories with medical gauze. Note that the metal mesh in the
nebulizing head should not be touched with any sharp or rough
objects. Gently dry the water inlet and outlet of the nebulizing head
with a medical swab.
5. If there is dust on the surface of the main unit, wipe it o with a
(moistened) gauze. Then use dry gauze to wipe the main unit.
6. Once the unit and accessories are completely dry, store them
in a clean storage bag.
NOTE
- Medication will build up around the nebulizer nozzle and mesh. After
each use, clean o all residue with medical gauze. Do not touch the
mesh disc spray area
- Do not wash the main unit -– Do not immerse in water
- Avoid using distilled water

15
Storage
• Store the device in a clean, dry place and protect it against
heat, sunshine, and moisture.
• Make sure the nebulizer has been cleaned and sterilized
thoroughly after each use.
• Make sure that the nebulizer and all accessories are
completely dry.
• Never place any heavy objects on the device.
• Remember to keep any heating device and open ames away
from the storage area.
• Refer to the Specications section in this manual for storage
environment temperature and humidity conditions. The device
may not work if the temperature and voltage conditions are
dierent to those dened.
STORAGE AND MAINTENANCE

16
STORAGE AND MAINTENANCE
Maintenance
Do not attempt any repairs to the device or any of its accessories.
Contact us at 1-800-363-2381 for repair information.
• The manufacturer will not be held responsible for the results
of maintenance or repairs by unauthorized persons.
• Check the device before each use for signs of wear and/or
damage. Replace worn items as required.
DISPOSAL
• Please dispose of the device in accordance with local
regulations (Waste Electrical and Electronic Equipment).
• Discard used batteries according to local environmental
regulations.
• Contact your local distributor for information regarding
disposal of the unit and accessories.

17
Trouble Possible Cause / Solution
Nebulizer does
not work
1) Reassemble the nebulizer
correctly. Refer to the Preparing
the Device section on page 8
and 9 of this manual.
2) The nebulizer (nozzle / metal
mesh) may be blocked. Clean
nebulizer (nozzle / metal mesh).
Refer to section - Cleaning
and Disinfecting. Replace the
medication cup (nozzle / metal
mesh) if necessary.
TROUBLESHOOTING
If your device does not seem to be operating correctly,
refer to the chart below to determine what may be wrong.
If none of these measures correct the problem, please
contact A.M.G. Medical Customer Service at: 1-800-363-2381,
between 8:30 AM and 5 PM EST.

18
Trouble Possible Cause / Solution
Low nebulization 1) Tilt the device towards yourself to
immerse the nebulizing head side
with medication in order to make full
use of it.
2) The nebulizer (nozzle / metal mesh)
may be blocked. Clean nebulizer
(nozzle / metal mesh). Refer to
section - Cleaning and Disinfecting.
Replace the medication cup (nozzle /
metal mesh) if necessary.
What medication
is suitable for
nebulization
1) Only use medications as prescribed
and instructed by your healthcare
professional.
2) If high-viscosity medication is used,
nebulization may be reduced.
TROUBLESHOOTING
Caution / Consult accompanying documents before use
Be careful of
electric shock
Upward Do not disassemble
Keep device dry
The application
part of Type BF
Read this manual /
Consult Instructions
before use
Separate collection for
electrical and
electronic equipment
General imperative
Power key
Other MedPro Respiratory Product manuals