manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Moldex
  6. •
  7. Respiratory Product
  8. •
  9. Moldex Air Series User manual

Moldex Air Series User manual

Other Moldex Respiratory Product manuals

Moldex 9001 Operator's manual

Moldex

Moldex 9001 Operator's manual

Moldex 8000 Series User manual

Moldex

Moldex 8000 Series User manual

Moldex 3000 NR Series User manual

Moldex

Moldex 3000 NR Series User manual

Moldex 9000 Series User manual

Moldex

Moldex 9000 Series User manual

Moldex 8000 Series User manual

Moldex

Moldex 8000 Series User manual

Moldex 9000 Series User manual

Moldex

Moldex 9000 Series User manual

Moldex 8000 Series User manual

Moldex

Moldex 8000 Series User manual

Moldex Smart Pocket FFP1 NR D Instruction manual

Moldex

Moldex Smart Pocket FFP1 NR D Instruction manual

Moldex 8000 Series User manual

Moldex

Moldex 8000 Series User manual

Moldex 7000 Series User manual

Moldex

Moldex 7000 Series User manual

Moldex 7000 Series User manual

Moldex

Moldex 7000 Series User manual

Moldex 0073-1 User manual

Moldex

Moldex 0073-1 User manual

Moldex 9000 Series User manual

Moldex

Moldex 9000 Series User manual

Moldex 8000 Series User manual

Moldex

Moldex 8000 Series User manual

Moldex 8000 Series User manual

Moldex

Moldex 8000 Series User manual

Moldex Classic+ FFP Series Instruction Manual

Moldex

Moldex Classic+ FFP Series Instruction Manual

Moldex 2380 User manual

Moldex

Moldex 2380 User manual

Moldex 7000 Series Operator's manual

Moldex

Moldex 7000 Series Operator's manual

Moldex Bitrex Fit Test Kit User manual

Moldex

Moldex Bitrex Fit Test Kit User manual

Popular Respiratory Product manuals by other brands

Dräger PSS Series Instructions for use

Dräger

Dräger PSS Series Instructions for use

ResMed MIRAGE SWIFT II 60891/1 user guide

ResMed

ResMed MIRAGE SWIFT II 60891/1 user guide

Omron COMP A-I-R NE-C801 instruction manual

Omron

Omron COMP A-I-R NE-C801 instruction manual

Ombra 63506 Instructions for use

Ombra

Ombra 63506 Instructions for use

Lotus M-9520A quick start guide

Lotus

Lotus M-9520A quick start guide

CERES nosko nebulizer kit manual

CERES

CERES nosko nebulizer kit manual

Dr.Frei NE-SM1 user manual

Dr.Frei

Dr.Frei NE-SM1 user manual

North 5400 series instruction manual

North

North 5400 series instruction manual

John Bunn Neb-u-Lite LX2 user manual

John Bunn

John Bunn Neb-u-Lite LX2 user manual

Philips Respironics EE Leak 1 AF541 Instructions for use

Philips

Philips Respironics EE Leak 1 AF541 Instructions for use

Sperian Panther Hip-Pac P9684 Series Operation manual

Sperian

Sperian Panther Hip-Pac P9684 Series Operation manual

Dräger X-plore 6570 quick start guide

Dräger

Dräger X-plore 6570 quick start guide

3M 8000 Series quick start guide

3M

3M 8000 Series quick start guide

Respironics SideStream HS860 Instructions for use

Respironics

Respironics SideStream HS860 Instructions for use

Sundstrom SR 500 Instructions for use

Sundstrom

Sundstrom SR 500 Instructions for use

Ambu SPUR II Instructions for use

Ambu

Ambu SPUR II Instructions for use

BLS 8000 Instructions for the use

BLS

BLS 8000 Instructions for the use

Dräger saver PP Series Instructions for use

Dräger

Dräger saver PP Series Instructions for use

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

CERTIFICATION
The Moldex Air FFP-masks meet the requirements of EN 149:2001 + A1:2009 and
are CE-marked in accordance with the requirements of European
89/686/EEC. The IFA (BGIA) Germany is responsible for both type examination
10) and monitoring of production (Article 11). In addition to this the unvalved
masks of the Series 3000 AIR meet the requirements of EN 14683:2005 accor-
ding to the Medical Device Directive 93/42/EEC. The products are manufactured
in an ISO 9001:2000 certified plant.
MATERIALS
Filter Layer, Inner Shell, DuraMesh®: Polypropylene,
Ethylene-vinyl acetate (EVA)
Nose Seal, Clip: Polyethylene
Head Strap: Polyester, Lycra
WEIGHT
3100: 26 g 3150: 21 g 3200: 28 g 3250: 23 g
AREAS OF USE
(WEL = Workplace Exposure Limit)
NR (non reusable): Single use.
Comfortable and durable throughout the whole shift.
D (Dolomite clogging test): Masks have passed the Dolomite clogging test.
Better breathing resistance for longer.
Air Series – Bi-Directional Protection
UK - 03 - 2011 / 01
CHARACTERISTICS
ActivForm®
Automatically fits to the face.
No manual adjustments by the user are necessary.
DuraMesh®
Masks have a strong and durable structure.
Low breathing resistance
Thanks to the Pleated Filter Technology the inhaled breathing
resistance is reduced by more than 50% whilst maintaining filtra-
tion performance. The filter surface has been increased by 260%.
Nose seal
The flexible nose seal improves fit and provides
optimum wearing comfort.
Clip & Adjustable Strap
Easy on & off; mask can be worn around
the neck during breaks.
Bi-Directional Protection
Protects the wearer and his surrounding area
Meets the requirements of EN 149 and EN 14683.
Individually packed
Protected from dust and kept hygienic before use.
Latex-Free
Doesn‘t contain natural latex.
100% PVC-FREE
All Moldex products and packaging are
completely free from PVC.
Two sizes
For an optimal fit even for smaller faces.
Datasheet
FFP masks
Protection against Dust, Mist,
Fumes & biological substances
LATEX
FREE
FFP2 NR D · Size M/L
3100 non valved
FFP2 NR D · Size S
3150 non valved
FFP3 NR D · Size M/L
3200 non valved
FFP3 NR D · Size S
3250 non valved
+260%
S
M/L
Level WEL Hazard type
Examples
FFP2 10 x AGAINST HARMFUL WATER AND OIL BASED DUSTS
Against toxic dusts in industrial applications and airborne
biological agents of risk group 2 (e.g. pollen, bacteria).
FFP3 20 x AGAINST HARMFUL AND CANCER CAUSING WATER
AND OIL BASED DUSTS
Like FFP2 + cancer causing agents and additional protec-
tion against radioactive aerosols and airborne biological
agents of risk group 3 (e.g.. viruses) and enzymes.
www.magusintl.com
TESTING ACCORDING TO EN 149:2001 + A1:2009
Total inward leakage
Ten test subjects perform a variety of exercises. During the exercises the amount
of test aerosol that penetrates the filter, face seal and valve are sampled. The
total inward leakage of 8 out of 10 test subjects shall not exceed the following
levels:
The filter penetration after loading the filter with 120 mg paraffin oil according
to DIN EN 149:2001 + A1:2009 shall not exceed the following levels:
TESTING ACCORDING TO EN 14683:2005
Requirements
The Air masks pass the examinations of the category IIR.
BFE testing method
An aerosol of Staphylococcus aureus is drawn through the filter material. The
filter efficiency against bacteria is declared by the amount of colony building units
which go through the mask.
INSTRUCTIONS FOR USE
· The masks are available in two sizes. According to the face dimensions the
appropriate mask has to be chosen (S or M/L).
· The user has to be trained and instructed in wearing the mask.
· FFP masks do not protect against gases and vapours.
· The oxygen concentration of the ambient atmosphere should be at 19,5 % Volume.
· These respirators may not be used if the concentration type, and properties of
contaminants in the ambient atmosphere are unknown or at dangerous levels.
· Respirators should be disposed if damaged, if the breathing resistance
be comes high due to clogging.
· Never tamper with, alter or modify the respirator.
Category max. Filter penetration
FFP2 6 %
FFP3 1 %
UK - 03 - 2011 / 02
Datasheet
FFP masks
Protection against Dust, Mist,
Fumes & biological substances
Testing Type I Type IR Type II Type
IIR
Bacterial filtration efficiency
(BFE) (%)
≥ 95 ≥ 95 ≥ 98 ≥ 98
Splash resistance (mmHg) not
applicable
≥ 120 not
applicable
≥ 120
Category max. total inward leakage
FFP2 8 %
FFP3 2 %
MOLDEX-METRIC AG & Co. KG
Unit 9, Glaisdale Point
Off Glaisdale Drive, Bilborough
Nottingham. NG8 4GP
Tel.: +44 (0)115 985 4288
Fax: +44 (0)115 985 4211
www.moldex-europe.com
[email protected]
INFO
For help on selection and training please
contact us. We offer a wide range of training
packages and support material.
INSTRUCTIONS FOR FITTING
1. Pull strap to form a
large loop.
2. Place respirator on chin and
pull loop over head tight to
the neck.
3. Pull upper strap and place on
back of head.
4. Adjust strap by pulling
loop on strap.
5. During breaks unclip strap.
6. Let mask hang around
your neck.
www.magusintl.com