λTa Emergency
lumen (lm)
The light source contained in this luminaire shall only be replaced by the manufacturer or his service agent or a similar qualified person.
De lichtbron
in deze lamp mag alleen worden vervangen door de fabrikant, zijn serviceagent of een vergelijkbaar gekwalificeerd persoon.
12W >0.7 N/A
300
N/A
300
N/A
300
300
N/A
300
300
N/A
300
300
N/A
N/A N/A
N/A
300
300
300
-20°C ~ +40°C
0°C ~ +35°C
-20°C ~ +40°C
0°C ~ +35°C
-20°C ~ +40°C
0°C ~ +35°C
0°C ~ +35°C
-20°C ~ +40°C
0°C ~ +35°C
0°C ~ +35°C
-20°C ~ +40°C
0°C ~ +35°C
0°C ~ +35°C
-20°C ~ +40°C
-20°C ~ +55°C
0°C ~ +45°C
0°C ~ +35°C
0°C ~ +35°C
FCL71600v0+LA10175
15W >0.7
FCL71600v0+LA11149
12W >0.7
FCL71600v0-sc+LA10175
15W >0.7
FCL71600v0-sc+LA11149
16W >0.7
FCL71700v0+LA10175
19W >0.7
FCL71700v0+LA11149
20W >0.7
FCL71700v0+LA10175+LA11149
16W >0.7
FCL71700v0-sc+LA10175
19W >0.7
FCL71700v0-sc+LA11149
20W >0.7
FCL71700v0-sc+LA10175+LA11149
23W/16W/11W >0.7
FCL71800v0-ds+LA10175
26W/19W/14W >0.7
FCL71800v0-ds+LA11149
27W/20W/15W >0.7
FCL71800v0-ds+LA10175+LA11149
23W/16W/11W >0.7
FCL71800v0-ds/sc+LA10175
26W/19W/14W >0.7
FCL71800v0-ds/sc+LA11149
27W/20W/15W >0.7
Ø (mm)
H (mm)
Ø280 x H100
Ø280 x H100
Ø280 x H100
Ø280 x H100
Ø330 x H110
Ø330 x H110
Ø330 x H110
Ø330 x H110
Ø330 x H110
Ø330 x H110
Ø390 x H115
Ø390 x H115
Ø390 x H115
Ø390 x H115
Ø390 x H115
Ø390 x H115
FCL71800v0-ds/sc+LA10175+LA11149
LA10175
LA11149
DAILY: check charge indicators are lit maintained/combined lamps illuminate; any faults are recorded
MONTHLY: in addition to the daily check - a functional test of at least 3 minutes duration to confilm lamp is working on battery power by simulating a mains failure.
SIX MONTHLY in addition, to the daily check - a functional test of at least one hour to confirm lamp is working on battery power by simulating a mains failure.
ANNUALLY: in addition to the daily check - a functional test of rated duration to confirm full operation to specification by simulating a mains failure.
A copy of this report must accompany any fitting returned to the manufacturer for any reason.
Note:After the main circuit is powered off, the photometric data in the emergency mode reaches 300 lm within 5 s.
The battery is replaceable, and the replacement of the battery is needed when they no longer meet their rated duration of operation after the corresponding recharge period.
EMERGENCY LUMINAIRE TEST RECORD
INSTALLATION ENGINEERS TEL
IDENT/SERIAL No
INSTALLATION DATE
LUMINAIRE TYPE
LOCATION
TEST
TYPE
FUNCTIONAL
FUNCTIONAL
FUNCTIONAL
1 HOUR
FUNCTIONAL
FUNCTIONAL
FUNCTIONAL
FUNCTIONAL
FUNCTIONAL
FUNCTIONAL
FULL DURATION
1 HOUR
1
2
3
5
6
7
8
9
10
11
13
12
SIGN
MONTH
DATE
SIGN
DATE
SIGN
DATE
SIGN
DATE
SIGN
DATE
FIRST
YEAR
SECOND
YEAR
THIRD
YEAR
FOURTH
YEAR
FIFTH
YEAR
FUNCTIONAL
4
IP44
220
-240V
AC 50/60
Hz
≤0.5W N/A
0.35
130mA/95mA/60mA
70mA
85mA
70mA
85mA
90mA
110mA
115mA
90mA
110mA
115mA
150mA/110mA/85mA
155mA/115mA/90mA
130mA/95mA/60mA
150mA/110mA/85mA
155mA/115mA/90mA
N/A
Max.55mA
4W
Test switch
C1x2
C4x1
C5x1
C6x1
C3x2
L1:
Permanent live
L:
Switched live
0%
L1
L
N
N
or
L1
LL1
L
N
MCB
24h
100%L1
L
N
MCB
3h
D1x1
A9x2
Replaced by Approved Battery
(LA11158 LiFePO4 1.5Ah 6.4V)
every 3 years
LA11149
24h
24hoder
Only for Ø 280 (FCL71600v0)
Ceiling light
Used for Ø330 (FCL71700v0)
and Ø390 (FCL71800v0)
Ceiling light
C2x1
220-240V~
2180
Ax