Mei-cha HIRA User manual

QUICKSTART GUIDE

Use only cartridges with complete sealed membrane to prevent
any fluid backflow.
Use barrier or sleeve to protect your device from fluid and
contamination.
Avoid dropping the device as it may cause damage to the
internal components.
Clean the device with power switched o.
Clean using proper disinfectant wipes or disposable pads with
sterilization solution.
Do not spray solutions or liquid directly onto the device.
Do not disassemble the device.
Do not attempt to lubricate the device.
Keep the device away from children.
Keep the device in its protective case and away from dust when
not in use.
THIS MEI-CHA DEVICE IS INTENDED FOR PROFESSIONAL USE ONLY.
BEFORE USING THIS DEVICE READ ALL GUIDELINES AND INSTRUCTIONS.
READ FIRST

Charge battery fully before first use.
Use only USB to USB-C cable for charging.
Always clean the device with the power switched o.
Do not attempt to clean the battery with sharp objects.
Do not incinerate or expose the battery to heat.
Do not disassemble, or modify the battery pack.
Do not drop the battery.
Do not immerse in any liquid. If dropped in liquid, retrieve with
caution.
Do not allow to be used as a toy. Keep away from children and
pets.
Immediately discontinue use of the battery if, while using or
charging, the battery emits an unusual smell, feels hot, or appears
abnormal in any way.
Please contact MEI-CHA or authorized distributor if you have any additional
questions.
IMPORTANT SAFETY INSTRUCTIONS
!
WARNING: THESE WARNINGS APPLY TO THE DEVICE, AND ALSO
WHERE APPLICABLE, TO ALL TOOLS, ACCESSOREIES, CHARGERS OR
ADAPTORS. TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR
INJURY.

KIT CONTENTS 5
TECHNICAL DATA 4
ASSEMBLY 6 - 9
OPERATION 10 - 11
CHARGING 12
TROUBLESHOOTING 13
WARRANTY 14

* Optimized for permanent makeup procedures
** Operating duration will decrease while using tattoo cartridges with larger
needle grouping
TECHNICAL DATA
DEVICE WEIGHT
RUNTIME WITH
TATTOO CARTRIDGES
DEVICE SHELL MATERIAL
STROKE LENGTH
MOTOR
SPEED RPM/PPS
BATTERY PACK
BATTERY CHARGING TIME
RUNTIME WITH
MEI-CHA CARTRIDGES
Up to 4 Hours **
Up to 6 Hours
3.5 Hours
850mAh Lithium-ion
5400/90 | 6300/105
6900/115 | 7800/130
Faulhaber DC Motor
2 mm *
3.9 oz
6061-T6 Aircraft
Grade Aluminum
4

KIT CONTENTS
RECHARGEABLE
BATTERY PACK X2 USB POWER ADAPTER
OPTIONAL GRIP FOR
STANDARD TATTOO
CARTRIDGE
USB TYPE A TO TYPE C
CHARGING CABLE
REPLACEMENT O-RING X2HIRA DEVICE
5

1. Match the indicators on the device and insert the battery pack.
2. Rotate the battery pack clockwise 45° to lock, as illustrated.
6

Insert needle cartridge to the opening of the grip and rotate
clockwise until locked into position.
ASSEMBLY — USING NEEDLE CARTRIDGE
7

1. Remove the grip by turning it counterclockwise.
2. Confirm the three o-rings are present on the device, as
illustrated. Install the optional grip by turning it clockwise.
ASSEMBLY — INSTALLING OPTIONAL
8

1. Insert tattoo cartridge* into the opening of the grip and
rotate clockwise until locked into position.
*Use cartridges with sealed membranes to avoid contamination.
Backflow fluid may cause damage to the device and void warranty.
CARTRIDGE WITH OPTIONAL GRIP
9

1. Power on the device with needle cartridge attached.
2. Adjust the needle length by turning the grip:
Turn clockwise to increase needle length.
Turn counterclockwise to reduce needle length.
10

1. Long press the button on the battery pack for 1.5 seconds
to power on/o. SMART MEMORY MODE: the device will
memorize the last speed setting used and start with the
same setting on the next power up.
1. Short press button to adjust speed level. There are 4
speed levels as indicated by the LED. The puncture per
second (PPS) of the levels are: 90/105/115/130.
OPERATION — SELECTING SPEED LEVEL
OPERATION — POWERING ON/OFF
11

1. The LED on battery will blink when remaining battery is
below 20%. Detach the battery from device to charge.
2. Plug the USB-C to USB cable into the USB-C charging
port, then connect to power source to charge using the USB
power adaptor.
3. The status light will indicate charging status.
RED: Charging
GREEN: Fully charged
CHARGING
12

BATTERY DOES
NOT CHARGE
ISSUE DIAGNOSIS FIX
Confirm the cable and
adapter are working
properly and plugged into a
working outlet.
Your serial number can be found on the main body of the device. If you still
have questions about your device after the above steps have been taken,
please contact MEI-CHA with your serial number and details of where and
when you bought the device.
TROUBLESHOOTING
Optional grip will only fit
standard tattoo cartridges,
check with your cartridge
supplier for specific fitting
requirement.
TATTOO
CARTRIDGE
DOES NOT FIT
Fitting issue
Confirm all three O-Rings
are present and replace if
necessary.
GRIP IS LOOSE
WHEN INSTALLED
Missing
O-Ring
Clean the electric connec-
tion between battery pack
and device with dry cloth.
INCONSISTENT
POWER OUTPUT
Poor power
connection
Use only USB to USB-C
cable for charging.
Wrong cable
Confirm the battery pack
is installed correctly in the
locked position.
MOTOR IS
NOT OPERATING
No power
connection
Charge the battery.
Insucient
power
DEVICE IS
RUNNING WEAK
Problem with
power supply
Charge the battery
and confirm the charging
indicator lights up.
BATTERY DOES
NOT LIGHT UP
Insucient
power
13

HIRA Device is designed for micropigmentation purposes and for
trained professional use only. The user is obligated to obtain
knowledge to operate and adhere to the local health authority’s
guideline for safe medical practice. Neither MEI-CHA or its aliates
assume responsibility or liability for any injuries or damages,
resulting, directly or indirectly, from the use of this product.
LIMITATION OF LIABILITY
MEI-CHA warrants the HIRA device for a period of six (6) months
starting from the original date of purchase, against defects due to
faulty manufacturing or material. If you discover a defect and notify
MEI-CHA during the warranty period, MEI-CHA will repair or replace
the machine free of charge. This warranty will be void if the
machine has undergone repeated dropping, exposure to moisture,
or shows signs of misuse that compromises its functionality.
For warranty claims, please contact your MEI-CHA distributor or
14
Table of contents