PUREBEAU Mobile 01 User manual

Instruction manual
Important recommendations
This manual contains instructions for operating this device. For making best use
of it and to avoid any risk of malfunction or damage to the device, every operator
and/or person responsable for maintenance, repair and service control should read
this manual carefully and keep to it.
Liability exclusion
This device is exclusively intended for skin pigmentation and also for laser-light
treatment of the skin to be carried out in accordance with the governing national
regulations for ensuring laser safety.
Operation of this device is only allowed to authorized medical personnel,
cosmeticians and trained professionels. Do not use it for other purposes as
described in this manual! In case of serious infectious deseases (AIDS, hepatitis
etc.) and haemophilia of the client, a treatment is contraindicated.
The manufacturer cannot be held liable for any failure to comply with the operation
instructions according to this manual or for any misuse.
The manufacturer grants a 24 months guarantee covering
the entire set, applicable only to those defects and/or
malfunctions caused by faulty workmanship or materials.
WARNING
Any work carried out by unqualified and/or unauthorized
persons or misuse will invalidate your warranty.
CERTIFICATE OF GUARANTEE
For the model purebeau mobile 01
Product serial N°:
RF foot control switch:
Starting on the date of
sale to the customer:
by:
Stamp Signature
manual
Purebeau New Cosmetics GmbH
Mozartstraße 12 13158 Berlin
Telefon: 030 - 4172 7611 / 030 - 8855 4096
Fax: 030 - 4172 7625

Typ 230.089 Gerät-Nr. 137 - 001
Purebeau New Cosmetics
Permanent - Make up
Made in Germany
Stromversorgung MW 9210GS
U 12 V
Pa 6 W
Nur mit mitgeliefertem
Original-Steckernetzteil
verwenden!
Technical data
Type 230.089
Power supply unit MW 9210GS 12V DC
Mains voltage 230 V
Dimensions d 65 x w 196 x h 212 mm (handle up)
d 109 x w 196 x h 178 mm (handle put up)
Working speed of the
pigmentation handpiece 90 - 250
Electric drive
of the handpieces precision DC-motor
Mode of operation continuous operation
Operating conditions ambient temperature 10 °C ... 35 °C
relative humidity 30 % ... 75 %
CE marking: This equipment complies with EMC
regulations (the European Community
Directives 89/336) and the regulations
for low voltage 73/23/EMC.
Due to technological advances we reserve the right to introduce modifications in the manufacture of our instruments. 2007/1
LCD Display
On /off key
Channel and menu for
RF foot control switch
Channel 0 - 7 mode for key
Channel 8 - F mode for catch
Attention!
Foot control switch and control unit
identical adjust.
Connector 1 Pigmentation handpiece
Connector 3 Softlaser
Connector antenna for
RF foot control switch
Connector power supply unit
Connector 2 Pigmentation handpiece
Control panel Connectors Indicators
Penholders for handpieces
manual

Connect the power supply unit to a 230 V power outlet before inserting the plug of
the flexible cord into its connector located on the rear of the control unit.
Put the handpieces delivered with this unit into their corresponding penholders.
Then insert the plug of the pigmentation-handpieces into one of the eligible
connectors 1 / 2, the plug of the softlaser-handpiece into the eligible connector 3.
For activating the device press its on/off key. Now the machine is in its basic
programm and the connector 1 is activated. In this basic programm all speeds can
be used in steps at 5 between 90 to 250. In all other programms the starting
speeds are set individually for lining, filling and can be changed in steps of 5 for
droping speed and increasing.
If the laser handpen icon is choosen, the foot pedal service is off as well as the
programm and the speed button. Select the drive button for switching on and off
the laser handpen.Then the laser is working on its set modus, no further set up is
required.
For operating the unit by its RF-cordless foot control switch, please provide for
having:
- inserted the block alkaline battery (9V) into the foot control switch;
- turned the rotary selector switch underside the foot control switch in the same
position like that of the rotary switch located under the key panel (each selectable
from 0 to F);
When selecting a position between 0 ... 7, a permanent pressure on the foot
control switch is required for operating the handpieces.
When selecting a position between 8.... F - press the foot control switch shortly
for putting the handpiece into operation. Handpiece operation will be stopped
after pressing it shortly again.
Servicing and care of the device
Standard set
Before requesting service Repair Complaint
Before servicing the device disconnect it from the mains.
Clean the unit from time to time gently with a lint-free cloth (probabely lightly
moistened with a readily soluble antiseptic, e.g. 50% 1-propanol solution in water).
All anodized surfaces of the permanent make-up device and its accessories should
have to be cleaned with LYSETOL MED. This cleaner is DGHM registered and
complies with the requirements of hygiene.
Before using other antiseptics, please pay attention to the corresponding user
instructions and/or ask your supplier for information.
In case of malfunction check first, if the power supply unit is properly connected to
the corresponding line voltage mains outlet.
If the permanent make-up device still proves to be defective, please contact your
next authorized service workshop or send it back to the manufacturer for a general
technical check up or repair.
Complaints have to be directed to your supplier.
Control unit
RF foot control switch
Power supply unit
Pigmentation handpiece
Instruction manual
optional:
Pigmentation handpiece
Softlaser-pen
Getting started Precautions Unit operation
The device has been manufactured in compliance with the relevant German VDE-
safety rules and supplied to the customer in perfect technical conditions. Only
connect this device to properly installed mains power sockets. The mains voltage
must always correspond to the primary level marked on the identification plate of
the power supply unit. Never try to open the device and repair it yourself. Any
maintenance or repair must be carried out by fully qualified technicians, authorised
therefore by the manufacturer. For trouble free use do only operate this device
indoors.
Switch off the device immediatly and protect it from improper and/or unauthorized
use in any case of danger or malfunction, such as:
·visible defects of the device or its accessories;
·performance faults;
·storage under unfavorable conditions for an extended period of time;
·damage in transit and/or heavy mechanical stress (push, drop etc.)
during transportation.
Please refer in such a case to ...requesting service.
Make sure that the instrument will be always placed on smooth surfaces and
operated only under supervision of trained persons.
Control unit

Function menu
00:00
Chart for all sorts of working speeds to the menu/secondary menu
Selection symbol for the softlaser-handpiece
(instead of the working speed)
Working speed
Display menu (secondary menu)
Outlet active
Stopwatch
Menu Secondary menu all sorts of working speeds
from/up to preset
Manual ------- 90 - 250 90
Eyebrow Line 130 - 250 150
Eyebrow Fill 170 - 250 200
Eyelid Line 130 - 250 150
Eyelid Fill 170 - 250 190
Lips Line 160 - 250 170
Lips Fill 140 - 250 170
Medical Line 160 - 250 170
Medical Fill 140 - 250 170
Tattoo Line 170 - 250 200
Tattoo Fill 200 - 250 220
Working speed faster
Working speed slower
Selection menu manual
drive - button
Outlet (handpiece) switch on
Selection outlet
Pigmentation-handpieces 1/2 or softlaser-handpiece
Selection menu eyebrow
Selection menu eyelid
Selection menu lip
Selection menu medical application
Selection menu Tattoo
Selection secondary menu line
Selection secondary menu fill
Stopwatch take off or stop
Stopwatch return
eyebrow