Meiko UPster K User manual

9726766 / Valid from: 2014-10-01 / Update: 2019-02-26
Rack type dishwashing machine
Operating instructions
UPster K
Translation of the "Original operating instructions"
EN

Operating instructions for rack type dishwashing machine , model Upster K
9726766 Design and construction subject to change without prior notice!
Page 2 of 42
Contents
1INTRODUCTION AND GENERAL INSTRUCTIONS....................................................4
1.1 Safe keeping 5
1.2 Name and address of manufacturer 5
1.3 Authorisation for service technicians of our service partners 5
1.4 Designation of installation 5
2EXPLANATIONS OF THE SAFETY SYMBOLS USED ...............................................6
2.1 Graphic reference symbols 6
3GENERAL DESCRIPTION AND USE FOR THE PURPOSE INTENDED....................7
3.1 General description 7
3.2 Intended use 7
3.3 Foreseeable use 8
4EC DECLARATION OF CONFORMITY .......................................................................8
4.1 EC-Declaration of Conformity 9
4.2 Declaration of Incorporation 10
5GENERAL SAFETY RULES ......................................................................................12
5.1 Operator’s duty of care 12
5.2 Measures to ensure safe system operation 12
5.3 Basic safety measures 13
5.3.1 Working on the electric fittings 15
5.3.1 Water installation work 15
6ASSEMBLY INSTRUCTIONS (FOR A PARTIALLY COMPLETED MACHINE)........16
6.1 Working on the electric fittings 16
7DELIVERY, TRANSPORT, INSTALLATION AND ASSEMBLY ................................17
7.1 Delivery 17
7.2 Transport and installation 17
7.3 Installation and assembly 18
7.4 Floor load from the dishwashing machine 18
7.5 Instructions for disposal of packing material 18
7.6 Requirements to the installation area 18
7.7 Requirements to the electrical connection 19
7.8 Temperature sensors/temperature limit switches 20
7.9 Fresh water connection 20
7.10 Waste water connection 21
7.11 Exhaust air connection of the appliance 21
7.12 Installing and connecting dosing equipment 22
8ADJUSTMENT OF THE MACHINES EFFECTED BY AUTHORISED SERVICE
TECHNICIAN DURING THE FIRST SETTING IN OPERATION.......................................23

Operating instructions for rack type dishwashing machine , model Upster K
9726766 Design and construction subject to change without prior notice!
Page 3 of 42
8.1 Commissioning 23
8.2 Chemical product settings 23
8.3 Work prior to initial commissioning 24
9OPERATING THE DISHWASHING MACHINE ..........................................................25
9.1 Basic safety measures for standard operation 25
9.2 Switching on and working with the machine 25
9.3 Washing interruption 27
10 SHUTTING DOWN THE MACHINE............................................................................28
11 CLEANING .................................................................................................................29
11.1 Cleaning - daily 29
11.2 Cleaning instructions – daily 30
12 MAINTENANCE AND CARE......................................................................................31
12.1 Care, general 31
12.2 Care of stainless steel surfaces 31
12.3 Check list after cleaning 31
12.4 Dosing of the detergent/rinse agent 32
12.5 Descaling the machine 33
13 OPERATING ERRORS...............................................................................................33
13.1 Help yourself in case of faults 34
14 STAFF TRAINING ......................................................................................................35
15 MAINTENANCE, SERVICING....................................................................................35
15.1 Basic safety measures during normal operation 36
15.1.1 Before setting in operation - after maintenance and repair works 36
16 MAINTENANCE MANUAL .........................................................................................37
17 DISPOSAL OF THE INSTALLATION.........................................................................38
18 NOISE EMISSION.......................................................................................................38
19 NON-IONISING RADIATION......................................................................................39
20 REGULATIONS AND STANDARD VALUES.............................................................39
21 ABBREVIATIONS.......................................................................................................39
22 INDEX .........................................................................................................................40
23 NOTES........................................................................................................................41

Operating instructions for rack type dishwashing machine , model Upster K
9726766 Design and construction subject to change without prior notice!
Page 4 of 42
1 Introduction and general instructions
Dear customer,
we are delighted about the confidence you have shown in our products.
It is very important to us that you should obtain a great deal of pleasure and use-
fulness from MEIKO products and that they should make your work easier.
If you follow the instructions in this document carefully, your machine will always
give you total satisfaction and will have a long service life.
After assembly at our factory, this machine was put through a thorough inspection.
This helps us make sure, and gives you the guarantee that you always receive a
mature product.
We would therefore ask you to read these operating instructions carefully be-
fore using the installation. Any further related operating instructions for ac-
cessories and incorporated third-party products must be strictly observed!
These operating instructions are designed to familiarise the owner/operator of this
system with its installation, modes of operation, use, safety instructions and servic-
ing.
In the event of any damage caused by non-observance of these operating instruc-
tions, any guarantee claims are invalid. We accept no liability for any additional
damage caused as a result.
MEIKO operates a policy of continuous development on all its appliances.
As a result of this, please understand that we thus reserve the right to make
changes to the scope of supply concerning the design, equipment and technical
features at any time.
No claims may therefore be based on the details, the images or the descriptions
contained in these operating instructions.
Should you require any further information, or in case any particular problems
should arise that are not dealt with in great detail in the operating instructions, you
may contact the relevant MEIKO branch to obtain the information you require.
Further, we draw your attention to the fact that the content of these instructions
does not form part of a former or existing agreement, promise or legal relationship
and does not modify such a point.
All MEIKO’s obligations arise from the relevant purchase contract which also con-
tains the entire and only valid guarantee provisions. These contractual guarantee
rules shall be neither extended nor restricted as a result of any explanations given
in the instructions.
The operating instructions must exist in the local language for each EU country. If
this is not the case, the installation must not be commissioned.
The original operating instructions in German and all operating instructions in all
languages for EU countries can be downloaded from the following address:
https://partnernet.meiko.de
You receive all this technical documentation free of charge. Any additional copies
required are available for a nominal fee.
MEIKO wishes you much pleasure and success!
© 2014 MEIKO Maschinenbau GmbH & Co.KG
All rights (including photo-mechanical reproduction and storage on electronic me-
dia) reserved to MEIKO Maschinenbau GmbH & Co KG. Any commercial use or
distribution of texts, illustrated models, drawings and photographs within this prod-
uct is not permitted. It is not permitted to reproduce, store or pass on the service
manual without any written approval, either in whole or in part, or transfer or trans-
late it, in any form or with any medium, without written approval.

Operating instructions for rack type dishwashing machine , model Upster K
9726766 Design and construction subject to change without prior notice!
Page 5 of 42
1.1 Safe keeping
Keep this operating manual in the vicinity of the installation in a location that is eas-
ily accessible to all users.
1.2 Name and address of manufacturer
In case of further questions or technical problems, contact directly:
MEIKO Maschinenbau GmbH & Co. KG
Englerstraße 3
D - 77652 OFFENBURG
Telefon +49 (0)781 / 203-0
http://www.meiko.de
info@meiko.de
or:
Name and address of the MEIKO branch, manufacturer’s agent
or from MEIKO authorised Service Partners
(Firmenstempel oder Anschrift eintragen)
1.3 Authorisation for service technicians of our service part-
ners
MEIKO exclusively authorises authorised Service Partners for commissioning, in-
ductions, repairs, maintenance, assembly and installation of the corresponding
product groups within MEIKO devices.
The service instructions feature additional information for authorised partners on
assembly, modifications and repairs of all optional modules for this dishwashing
machine.
1.4 Designation of installation
Please provide the following information on any query and/or when ordering spare
parts:
Type:
SN:
This information can be found on the type plate.

Operating instructions for rack type dishwashing machine , model Upster K
9726766 Design and construction subject to change without prior notice!
Page 6 of 42
2 Explanations of the safety symbols used
The following safety symbols will appear throughout these operating instructions.
These symbols are designed to draw the reader's attention to the text next to the
safety instructions.
DANGER
Refers to a dangerous situation which results in death or serious bodily injury.
WARNING
Refers to a dangerous situation which can result in death or serious bodily injury.
NOTE
Refers to a situation which can result in damage to property.
Application information and other useful information
2.1 Graphic reference symbols
The following notes and risk symbols can occur wholly or in part in the operating
manual and on the installation. These symbols (or symbols on the installation)
must be observed without fail!
The symbols have the following functions:
Caution!
Electric shock!
Caution!
Hand injuries!
Caution!
Heavy loads!
Caution!
Hot surfaces!
No splashing water! Access prohibited for
persons with pacemak-
ers!
Caution!
Non-potable water!
Caution!
Do not reach into the
unit!
Use protective gloves! Wear safety glasses!

Operating instructions for rack type dishwashing machine , model Upster K
9726766 Design and construction subject to change without prior notice!
Page 7 of 42
3 General description and use for the purpose in-
tended
3.1 General description
This machine is a rack type dishwashing machine for dishes and common kitchen
utensils.
Tables or conveyors can be put on the feeding or discharge side of the machine for
loading and unloading dishware baskets.
The dishes to be cleaned are put into carrier baskets, preferably made of plastic,
and transported through the dishwashing machine on transport equipment.
Wash ware is cleaned using a heated wash tank.
The dishes are finally rinsed using heated fresh water sprayed through fine noz-
zles.
3.2 Intended use
The dishwashing machine must be used according to its purposes only.
This dishwashing machine is intended for washing dishes and commonly used
kitchen utensils.
Where applicable, other special wash ware is described in the order confirmation.
The items to be washed must be suitable for industrial dishwashing.
In case of doubt, an agreement (size, version, basic suitability of dishwashers) can
be concluded with Meiko concerning the suitability (info@meiko.de).
Kitchen utensils that are equipped with electric components must not be washed in
the machine.
The wash ware must not protrude from the dishwasher basket on the sides or at
the bottom.
Any other use is not considered intended.
This dishwashing machine is intended solely for use in a commercial environment.
The intended use of the system specifies that qualified and instructed personnel
operates the system only!
Qualified personnel must be older than 14 years of age. Personnel must have been
adequately qualified, instructed and authorised by the operator!
Feeding side
Discharge side
Drying
Dish support
basket

Operating instructions for rack type dishwashing machine , model Upster K
9726766 Design and construction subject to change without prior notice!
Page 8 of 42
3.3 Foreseeable use
The dishwashing machine must not be used for the following foreseeable uses:
•Kitchen utensils that are equipped with electric components.
•Textiles, oven cloths or steel sponges.
•Utensils that must not come into contact with foodstuff, such as ashtrays,
candlesticks, etc.
•Living creatures
•Foodstuff intended for consumption
•Iron utensils
•Support grids of cooking hobs / gas hobs
•Wash ware that is not dishwasher-proof
4 EC Declaration of Conformity
A Declaration of Incorporation is provided with the machine if it is not supplied in
fully operational state, that is, as a partially completed machine pursuant to the
Machine Directive.
An EC Declaration of Conformity is provided with the machine if it is supplied in ful-
ly operational state as a complete machine.

Operating instructions for rack type dishwashing machine , model Upster K
9726766 Design and construction subject to change without prior notice!
Page 9 of 42
4.1 EC-Declaration of Conformity
Muster / Example / Exemple / Esempio / Ejemplo / Voorbeeld / Mönster
EG-/EU-Konformitätserklärung
2017-11-07 (Update)
EC-/EU-Declaration of Conformity / CE-/UE-Déclaration de conformité / CE-/UE-Dichiarazione di conformità / CE-/UE-Declaración de conformidad /
EG-/EU-conformiteitsverklaring / EG-/EU-försäkran om överensstämmelse
Firma
Company / Société / Ditta / Empresa / Fabrikant / Företag
MEIKO Maschinenbau GmbH & Co. KG
Englerstraße 3 - 77652 Offenburg - Germany
Kontakt
Contact / Contact / Contatto / Contacto / Contact / Kontakt
Internet: www.meiko.de
E-mail: [email protected]e
Telefon: +49(0)781/203-0
Seriennummer
Serial number / numéro de série / numero di serie / número de serie / volgnummer / serienum-
mer
Spülmaschine
Dishwasher / Lave-vaiselle / Lavastoviglie / Lavavajillas / Vaatwasmachine / Diskmaskin
UPster K
Typ / Model / Modèle / Modelo / Modelo / Model / Modell
Konformitätserklärung
Declaration of Conformity / Déclaration de conformité / Dichiarazione di conformità / Declaración de conformidad / Conformitetsverklaring /
Försäkran om överensstämmelse
Hiermit bescheinigen wir in alleiniger Verantwortung die Konformität des Erzeugnisses mit den grundlegenden Anforder-
ungen der folgenden EG-Richtlinien, harmonisierten Normen, nationalen Normen.
We hereby declare at our sole responsibility that the product conforms to the essential requirements of the following EC Directives, harmonized stand-
ards, national standards.
Par la présente nous certifions sous notre seule responsabilité la conformité du produit avec les exigences fondamentales des directives CE,
normes harmonisées et normes nationales suivantes.
Con la presente dichiariamo sotto la nostra responsabilità la conformità del prodotto con i regolamenti basilari delle seguenti direttive CE, normative
armonizzate e normative nazionali.
Por la presente declaramos bajo nuestra sola responsabilidad que nuestros productos están en conformidad con las exigencias básicas de las siguientes
directivas de la CE, normas homologadas y normas nacionales.
Hiermee verklaren wij onder geheel eigen verantwoordelijkheid de conformiteit van het product met de fundamentele en gestelde eisen volgens
EG-richtlijnen, geharmoniseerde normen en nationale normen.
Vi intygar härmed på eget ansvar att produkten överensstämmer med de väsentliga kraven i nedan angivna EG-direktiv, harmoniserade standarder och
nationella standarder.
Richtlinie
/ Directive / Directive / Direttiva / Directiva / Richtlijn / Direktiv
2006/42/EG / 2014/30/EU
Dokumentationsbevollmächtigter
Viktor Maier
Responsible for documentation / Responsable de la documentation / Responsabile della docu-
mentazione/ Responsable de la documentación / Voor deze documentatie verantwoordelijk /
Ansvarig för dokumentation
MEIKO Maschinenbau GmbH & Co. KG
Englerstr. 3 – 77652 Offenburg - Germany
Offenburg,
MEIKO Maschinenbau GmbH & Co. KG
ppa.
(per procura)
Dr. Thomas Peukert
Technischer Leiter
Chief Technology Officer / Directeur de la technologie / Direttore tecnico /
Director técnico / Technisch directeur / Teknisk direktör

Operating instructions for rack type dishwashing machine , model Upster K
9726766 Design and construction subject to change without prior notice!
Page 10 of 42
4.2 Declaration of Incorporation
Muster / Example / Exemple / Esempio / Ejemplo / Voorbeeld / Mönster
Einbauerklärung
Datum: 2017-11-07 (Update)
Declaration of incorporation / Déclaration de montage / Dichiarazione di montaggio / Declaración de montaje /
Inbouwverklaring / Försäkran om inbyggnad
Firma
Company / Société / Ditta / Empresa / Fabrikant / Företag
MEIKO Maschinenbau GmbH & Co. KG
Englerstraße 3 - 77652 Offenburg -Germany
Kontakt
Contact / Contact / Contatto / Contacto / Contact / Kontakt
Internet: www.meiko.de
E-mail: [email protected]e
Telefon: +49(0)781/203-0
Seriennummer
Serial number / numéro de série / numero di serie / número de serie / volgnummer / serienum-
mer
Maschinentyp
Machine type / Modèle machine / Tipo di macchina / Tipo de máquina / Machinemodel / Modell
Einbauerklärung für eine unvollständige Maschine
Declaration of incorporation for partly completed machinery / Déclaration de montage pour une machine incomplète / Dichiarazione di montaggio per una
macchina incompleta / Declaración de montaje de incorporación para una máquina incompleta / Inbouwverklaring voor een onvolledige machine /
Försäkran om inbyggnad för en ofullständig maskin
Hiermit bescheinigen wir:
We herewith certify / Nous certifions par la présente / Con la presente attestiamo / Por la presente certificamos / Hiermee verklaren wij / Vi intygar härmed:
dass die zum Einbau in Maschinen vorgesehenen Produkte oder Baugruppen mit den grundlegenden Sicherheits- und Ge-
sundheitsschutzanforderungen nach Anhang I der Maschinenrichtlinie 2006/42/EG übereinstimmen. Die speziellen tech-
nischen Unterlagen gemäß Anhang VII B (für unvollständige Maschinen) wurden erstellt und werden der zuständigen Behörde
auf Verlangen in elektronischer Form übermittelt.
that the product or sub-assemblies that are intended for installation in machines complies with the fundamental health and safety requirements in accord-
ance with Annex I of the Machine Directive 2006/42/EG. The special technical documents have been created according to Annex VII B (for partly completed
machinery) and shall be transferred to the responsible authority in electronic format when requested.
que les produits et modules destinés au montage dans des machines satisfont aux exigences fondamentales en matière de sécurité et de santé con-
formément à l'annexe I de la directive sur les machines 2006/42/CE. Les dossiers techniques spécifiques conformément à l'annexe VII B (pour les ma-
chines incomplètes) ont été rédigés et seront transmis sur demande aux autorités responsables sous forme électronique.
che i prodotti o gruppi di componenti previsti per il montaggio in macchine corrispondono ai requisiti essenziali di sicurezza e di tutela della salute secondo
l'allegato I della Direttiva Macchine 2006/42/CE. La documentazione tecnica speciale secondo allegato VII B (per macchine incomplete) è stata creata e
sarà trasmessa su richiesta e in forma elettronica all'ente responsabile.
que los productos o grupos previstos para la incorporación en máquinas cumplen con los requisitos básicos de seguridad y protección de la salud, con-
forme al anexo I de la directiva de máquinas 2006/42/CE. Se han confeccionado los documentos técnicos especiales conforme al
anexo VII B (para
máquinas incompletas), que se entregarán a las autoridades competentes en forma y por vía electrónica, en caso de solicitarlo las mismas.
dat de voor inbouw in de machine bestemde producten of bouwgroepen voldoen aan de fundamentele eisen met betrekking tot de ve
iligheid en
bescherming van de gezondheid conform bijlage I van de machinerichtlijn 2006/42/EC. De speciale technische documentatie is conform bijlage VII B (voor
onvolledige machines) opgesteld en wordt desgewenst in elektronische vorm ter beschikking gesteld aan de verantwoordelijke instanties.
att produkterna eller komponenterna som är avsedda för inbyggnad i maskiner överensstämmer med de grundläggande säkerhets- och hälsoskyddskraven
i bilaga I i maskindirektivet 2006/42/EG. De särskilda tekniska underlagen enligt bilaga VII B (för ofullständiga maskiner) har tillhandahållits och översänds
på begäran till ansvariga myndigheter i elektronisk form.
die Konformität mit den Bestimmungen folgender weiterer EG-Richtlinien:
the conformity with the provisions of the following additional EC Directives:
la conformité avec les dispositions des directives européennes supplémentaires suivantes:
la conformità alle disposizioni delle seguenti ulteriori direttive CE:
la conformidad con las disposiciones de las siguientes directivas de la CE adicionales:
de conformiteit met de bepalingen van de volgende aanvullende EC-richtlijnen:
överensstämmelse med bestämmelserna i nedan angivna ytterligare EG-direktiv:
2014/30/EU

Operating instructions for rack type dishwashing machine , model Upster K
9726766 Design and construction subject to change without prior notice!
Page 11 of 42
Die vorgenannten speziellen technischen Unterlagen können angefordert werden bei:
The above mentioned technical documentation can be requested from:
Les documents techniques spécifiques précités peuvent être demandés auprès de:
La suddetta documentazione tecnica speciale può essere richiesta presso:
Los documentos técnicos especiales reseñados con anterioridad se pueden solicitar a:
De bovengenoemde speciale technische documentatie kan worden opgevraagd bij:
Ovannämnda särskilda tekniska underlag kan beställas från:
Dokumentationsbevollmächtigter
Viktor Maier
Responsible for documentation / Responsable de la documentation / Responsabile della docu-
mentazione/ Responsable de la documentación / Voor deze documentatie verantwoordelijk
MEIKO Maschinenbau GmbH & Co. KG
Englerstr. 3 - 77652 Offenburg - Germany
Die Inbetriebnahme ist so lange untersagt, bis festgestellt wurde, dass die Maschine oder Anlage, in welche die o.a. unvoll-
ständige Maschine eingebaut werden soll, den Bestimmungen der Maschinenrichtlinie 2006/42/EG entspricht.
Commissioning is prohibited until it has been determined that the machine or system into which the partially completed machinery specified above is to
be incorporated also complies with the provisions of the Machinery Directive 2006/42/EC.
La mise en service de la machine est interdite jusqu'à ce qu'il ait été déterminé que la machine ou l'installation dans laquelle la machine incomplète
susmentionnée doit être montée respecte les dispositions de la directive relative aux machines 2006/42/CE.
La messa in funzione è vietata fino a che non sia stato accertato che la macchina o l'impianto, in cui deve essere installata la suddetta macchina incom-
pleta, risponda alle disposizioni della Direttiva Macchine 2006/42/CE.
La puesta en marcha estará prohibida hasta que no se haya determinado que la máquina o instalación en la que se pretenda incorporar la máquina
incompleta indicada arriba cumpla las disposiciones de la directiva de máquinas 2006/42/CE.
De inbedrijfstelling is niet toegestaan voordat is vastgesteld dat de machine of installatie waarin de o.a. onvolledige machine moet worden ingebouwd
aan de bepalingen van de machinerichtlijn 2006/42/EC voldoet.
Idrifttagande är förbjudet tills att det har fastställts att maskinen eller anläggningen som den ovannämnda ofullständiga maskinen ska byggas in i uppfyller
bestämmelserna i maskindirektivet 2006/42/EG.
Offenburg,
MEIKO Maschinenbau GmbH & Co. KG
ppa.
(per procura)
Dr. Thomas Peukert
Technischer Leiter
Chief Technology Officer / Directeur de la technologie / Direttore tecnico /
Director técnico / Technisch directeur / Teknisk direktör

Operating instructions for rack type dishwashing machine , model Upster K
9726766 Design and construction subject to change without prior notice!
Page 12 of 42
5 General safety rules
NOTE
The following safety instructions are for your protection as well as the protection of
others and the dishwasher. Compliance with the instructions is therefore absolutely
necessary.
5.1 Operator’s duty of care
This machine has been constructed and designed based on a risk assess-
ment and careful selection of the applicable harmonised standards, as well
as additional technical specifications.
It is therefore state of the art and guaranteed to provide maximum safety. Safety
can only be guaranteed during operation if all necessary measures are taken.
The operator of the installation has an obligation of care to ensure that these
measures are planned for, and also to check that they are correctly implemented.
5.2 Measures to ensure safe system operation
The operator must ensure in particular that ...
•a locally available power disconnection unit is installed. The power disconnec-
tion unit must be easily accessible and in the direct vicinity of the warewashing
machine.
The following requirements must be fulfilled:
– Load-break switch as per IEC 60947-3
– Utilisation category AC23B
– Lockable in OFF position
– Protection class against water IPX5
– The load-break switch must be installed in the direct vicinity of the
machine and must be easily accessible at a height of 0.6 - 1.9m
– Short-circuit breaking capacity >= 10kA
– Load-break switch rated operating current
– >= Machine's total current (type label) + 10%
– Neutral conductor shutdown optional
•the dishwashing machine is used in accordance with the regulations only.
in case of other use or operation, damage or risks may arise for which we ac-
cept no liability (cf. chapter "Intended use").
•in order to preserve the operational and safety guarantees, whenever re-
quired, only original parts supplied by the manufacturer are used. Any poten-
tial claims by the user shall be rendered void if the system was altered using
parts other than original spare parts.
•only appropriately qualified and authorized personnel use, maintain, and re-
pair the installation.
•staff is regularly trained in all questions relating to occupational safety and en-
vironmental protection and, in particular, that staff is familiar with the operating
instructions as well as with the safety instructions they provide.

Operating instructions for rack type dishwashing machine , model Upster K
9726766 Design and construction subject to change without prior notice!
Page 13 of 42
•the dishwashing machine is only operated in a perfect, operationally efficient
condition and, in particular, that the safety systems and switch elements are
checked on a regular basis for their operational efficiency.
•the required personal protective equipment is made available to and used by
maintenance and repair personnel.
•a functional test on all safety systems of the installation is carried out during
every regular maintenance.
•all the safety, warning and operating instructions provided are not removed
and are legible.
•any necessary initial tests to parts supplied by sub-suppliers, such as heat
pumps or other equipment, must be carried out. More detailed information, if
required, can be found in the relevant operating instructions.
•there are no further modifications after assembly, commissioning and hando-
ver of the dishwashing machine to customers/operators (e.g. electrical modifi-
cations or location changes). modifications to the dishwashing machine, and
in particular technical modifications carried out without the manufacturer’s writ-
ten authorization, or any modifications carried out by unauthorized persons,
will lead to the complete loss of any guarantee claims and will invalidate any
liability for the product.
•equipment for optimising energy consumption must not be used to reduce es-
sential operating temperatures, as set out in DIN 10511, 10512 and 10522. If
you, the client, install equipment for optimising energy consumption, any pos-
sible reduction in the quality of the wash and hygiene is your responsibility.
5.3 Basic safety measures
DANGER
Risk of injury due to electric shock, damage to property.
Parts carrying electric current as well as moving or rotating parts can
cause·danger to the user’s life and limb and material damage.
Danger can arise from the improper use of the machine or if it is used for pur-
poses for which it was not intended.
The machine may only be operated by adequately qualified staff who have been
trained by the operating company and who have been trained about the hazard
and safety instructions.
When electrical equipment is in operation, it is inevitable that certain parts carry
a dangerous current.
The entire dishwashing machine must be de-energised before opening dish-
washing machine cover panels or electrical equipment.
SWITCH the locally available MAIN SWITCH TO “OFF“ and install suitable lock-
ing devices to prevent the switch from being switched back on.
Work and troubleshooting on electrical parts of the dishwashing machine must
be performed by specialists only. Observe accident prevention regulations.
The operator must not restart the dishwashing machine until all cover panels
have been put back in place.
•Qualified staff, as defined by the Operating Instructions, are persons:
– over 14 years of age
– who have read and observe the safety instructions as well as the operating
instruction,

Operating instructions for rack type dishwashing machine , model Upster K
9726766 Design and construction subject to change without prior notice!
Page 14 of 42
NOTE
Damage to property
Do not spray the installation, switch cabinets and electronic components using a
water hose or high-pressure cleaner !
Avoid flooding the base of the system to prevent damage to components from pene-
trating water!
Observe all the instructions posted on the installation.
The dishwashing machine may only be operated under the supervision of trained
personnel. Do not use the dishwashing machine if you are unsure about system
operation.
Do not reach into the machines when they are in operation.
Switch off the machine before opening doors/flaps.
Open doors/flaps slowly: avoid contact with splashing water containing detergent
solution.
The water in the wash-up area is non-potable and must not be used for food prepa-
ration!
The dishwashing machine must not be used to transfer waste water from other
sources into the drain.
Always keep hatches and cover panels closed!
The tank heating elements may still be hot after draining the tank. As a result, there
is a risk of burns or scalding when cleaning the machine manually!
All work and troubleshooting must be carried out by qualified professionals.
Only use detergents, rinse aid and additives suitable for commercial dishwashing
machines. Do not use said substances for any other purpose than their intended
purpose. Please contact the manufacturers of these products für information.
Detergent, rinse aid and additives may contain hazardous substances. Observe
the manufacturers' hazard warnings on the original containers and safety data
sheets. Observe the instructions of chemical product suppliers with regard to use
and dosage.
Hazardous, chemical substances used to operate the machine may escape when
changing packing.
Wear personal protective equipment!
The operator's organisational methods must be followed if an injuries is caused
when using the appliance. Go to see a doctor if an infection progresses.
Please turn off the main switch at end of operations.

Operating instructions for rack type dishwashing machine , model Upster K
9726766 Design and construction subject to change without prior notice!
Page 15 of 42
NOTE
Wear suitable work clothing
Loose clothing and jewellery increases the risk of being caught on protruding parts.
•Wear closely fitting work clothing. Wear trousers down to the ankles or an apron.
•Do not wear rings, necklaces, or other pieces of jewellery.
•Wear protective gloves.
•Wear secure, suitable shoes. (We recommend wearing safety shoes with steel
toe caps)
WE DO NOT ACCEPT NO LIABILITY FOR DAMAGE OR
INJURY ARISING FROM FAILURE TO OBSERVE AND
ABIDE BY THESE SAFETY INSTRUCTIONS!!!!
5.3.1 Working on the electric fittings
DANGER
Risk of injury due to electric shock!
Any repair work and troubleshooting on the system's electrical equipment must be
carried out by a qualified electrician!
Before carrying out any maintenance and repair work, switch off
the power supply at
the main electrical power isolator switch and secure the switch with a padlock!
The key for this lock must be kept in the hands of the person carrying out the
maintenance and repair work!
Failure to observe these precautions can result in severe injury or damage to proper-
ty.
Check the electrical equipment regularly!
Tighten any loose connections!
Replace any damaged leads/cables immediately!
Always keep the switch cabinet closed! Access for qualified persons only.
5.3.1 Water installation work
WARNING
Risk of injury, damage to property!
Risks from unauthorised modifications on the installation and high water pressure.
Shut off and lock the main water supply valve before performing maintenance and
repair work on the water installation!

Operating instructions for rack type dishwashing machine , model Upster K
9726766 Design and construction subject to change without prior notice!
Page 16 of 42
6 Assembly instructions (for a partially completed
machine)
These apply where the MEIKO product is a partially completed machine in the
sense of the Machinery Directive (Directive 2006/42/EC).
Observe the following items when connecting MEIKO products to an existing instal-
lation:
- The components must be aligned with one another, connected in an appropri-
ate manner, and fastened so that safe operation is assured. (Choose conditions
and fasteners on site in line with this).
- Dangers (e.g. drawing in, crushing, shearing or cutting) that potentially arise
due to the connection must be prevented appropriately.
- The electrical connection to the supply grid on site, and any necessary electri-
cal connections must be implemented in line with the enclosed wiring diagram.
- During installation, make sure that you avoid damage, in particular to the elec-
trical installation.
- After completing the works, check the system for damage.
- Safety and function checks must be performed at the latest within the scope of
overall system testing prior to commissioning/machine handover.
6.1 Working on the electric fittings
DANGER
Risk of injury due to electric shock
Work or repairs to the electrical equipment of
the system must be conducted by a
qualified electrician!
The wiring diagram for the partially completed machine delivered contains all nec-
essary operational shut-offs known to the manufacturer MEIKO, as well as other
known, necessary shut-offs and electrical connections. Connections have been il-
lustrated on the wiring diagram. Always make sure that these connections are im-
plemented prior to commissioning the machine, and that they work reliably.
If any unknown sources of danger that are not described by MEIKO arise due to
connecting system parts, you must eliminate them; this may potentially mean that
you must not operate the machine.

Operating instructions for rack type dishwashing machine , model Upster K
9726766 Design and construction subject to change without prior notice!
Page 17 of 42
7 Delivery, transport, installation and assembly
7.1 Delivery
NOTE
Check that the delivery is complete
immediately after receiving it by comparing it to
MEIKO’s contract confirmation and/or the delivery note.
If necessary, complain about any missing parts immediately to the shipping company
and notify MEIKO.
Check the entire installation for any damage that may have occurred during shipping.
In the event of any transport damage, please inform MEIKO immediately in writing,
and also send a photo of the damaged parts to us.
7.2 Transport and installation
WARNING
Risk of injury caused by heavy loads!
In order to avoid damaging the machine and causing serious injury during transport,
loading, unloading and transport must be carried out by qualified personnel as per
locally applicable occupational safety instructions.
Read the chapter "General safety instructions".
•The machine must only be trans-
ported on the supplied wooden
frame. The packing is specifically
designed to allow the appliances
to be moved safely and securely
using a pallet jack or a sack truck.
•For safe transport, the machine is supported by a special square-timber
frame.
•Open packaging using a suitable tool.
•Observe transport instructions on the packing.
•Handle with care.
•Unpack the machine.

Operating instructions for rack type dishwashing machine , model Upster K
9726766 Design and construction subject to change without prior notice!
Page 18 of 42
7.3 Installation and assembly
MEIKO created an installation drawing featuring machine dimensions as well as
connection and consumption values.
The system must be installed as per the information in the installation drawing. It
must be installed by a licensed and authorised technician.
Assembly is completed by reference to the assembly diagram and, in general, by
following the instructions of a trained MEIKO engineer. The machine must be in-
stalled and connected by an approved professional.
For Australia only:
The equipment must be installed in accordance to AS/NZ 3500.1.
We do not accept any liability for damage caused by unprofessionally implemented
connection work.
System installation steps:
Position the unpacked machine according to the dimensions specified on the in-
stallation drawing.
Set up the machine so that it is correctly levelled and aligned.
Refer to the separate installation instructions for additional information on installa-
tion.
7.4 Floor load from the dishwashing machine
The floor load per leg (with a loaded area Ø=30 mm per leg) is approx. 220 kg
7.5 Instructions for disposal of packing material
• The four-sided wooden frame consists of untreated, raw pine / spruce. Special
country-specific import regulations may also stipulate the use of wood which
has been treated against pests.
• The plastic sheeting (PE sheeting) may be recycled.
• The cardboard packaging material used to protect the edges can also be re-
cycled.
• The steel strap from the packaging can be recycled as steel scrap.
• The plastic tensioning strap (PP) can be recycled.
7.6 Requirements to the installation area
•Ensure that the storage and installation area is permanently frost free.
If the system is installed in an area where the surrounding temperatures are
below 0°C, the water freezing inside may damage the internal water compo-
nents (pump, solenoid valve, etc.).
•Anti-slip floor coverings must be provided in the system's work area.

Operating instructions for rack type dishwashing machine , model Upster K
9726766 Design and construction subject to change without prior notice!
Page 19 of 42
7.7 Requirements to the electrical connection
DANGER
Risk of injury due to electric shock!
Work on the electrical machine components may be undertaken by specialist electri-
cians only.
General Electrical Regulations must be observed when connecting the machine to
the power supply.
The electrical cabinet features the corresponding wiring diagram. This wiring dia-
gram forms part of the machine and for this reason, it must not be removed.
There are two type plates indicating the electrical connected loads, one visible from
the outside and one on the inside of the electrical cabinet.
When connecting the power supply line to the machine, observe the general
electrical regulations
For USA/Canada only:
The dishwasher must be/is installed in accordance with local codes, or in the ab-
sence of local codes, installed in accordance with the applicable requirements in the
National Electrical Code, NFPA 70, Canadian Electrical Code (CEC), Part 1, CSA
C22.1, and Standard for Ventilation Control and Fire Protection of Commercial Cook-
ing Operations, NFPA 96.
Attention:
The pre-fuse in the building must be chosen to meet local requirements and
match the nominal machine current in order to provide back up protection
(VDE 0100 for Germany).
The mains supply cable must be provided with fuses in accordance with reg-
ulations and must have a main switch (accessible on site or on the appliance
for operating personnel). If the neutral line (N) is not earthed, you must use a
4-pin master switch. Mains connecting leads must be oil-resistant, shielded
cables no lighter than an H 07 RN-F cable.
The potential equalisation connection must be carried out in accordance with
the requirements of the local electricity supply company and all applicable
local regulations (in Germany VDE 0100 Part 540 must be observed).
Connect the machines to the building's equipotential bonding. The machine-
side connection is located very close to the machine’s central switch cabi-
net/unit sheet on the undercarriage in the form of a screw and is marked ac-
cordingly.
VDE 0160/EN 50178 specifies that within electrical equipment featur-
ing/planning to use residual current de-vices on the grid side to install AC/DC
sensitive type B FC frequency converters upstream/instead of the installed
type A FC frequency converters.
A 5-pin terminal strip is provided for the mains connection (L1, L2, L3, N, PE).
The electrical connection data, voltage, current type, current intensity, rating, etc.
are indicated on the type plates of the machine.
Please check the voltage.
Route all electrical cable connections through the marked cable gland to the in-
tended terminals and contactors in the electrical cabinet and connect to the intend-
ed terminals and contactors.

Operating instructions for rack type dishwashing machine , model Upster K
9726766 Design and construction subject to change without prior notice!
Page 20 of 42
7.8 Temperature sensors/temperature limit switches
All safety temperature limiters and temperature sensors which have been loosely
rolled must be positioned in their correspondingly highlighted location.
CAUTION:
Do not bend the capillary filling pipe, as otherwise the tem-
perature probe could become damaged and unserviceable!
Observe the instructions on installation and removal in the
service instructions!
7.9 Fresh water connection
The water-carrying pipes and components are not frost-proof. If the temperature of
the place where the appliance has been installed can fall below 5°C, suitable pre-
cautions for protection against frost must be taken.
•Information on nominal widths, diameters, etc. relate to the connections on the
machine.
•Installations on site must be dimensioned to match local conditions (e.g. cable
arrangements, access lengths). Media and power connection of the machine
are described in the service instructions.
•The connections must be made by approved professionals.
•All parameters for the media and energy supplies must be maintained at a
constant level during all the operations.
•Fresh water connections must be carried out in accordance with the require-
ments of the local regulations (e.g. Germany DIN 1988).
•The owner/operator must install a shut-off device in each water supply
pipe/hose; the device must be accessible to operating personnel.
•A supply disconnection has been installed depending on the machine version.
Refer to the service instructions for more detailed information.
•Waste water connections must be implemented in accordance with local regu-
lations (for Germany e.g. DIN 1986).
•When using water softening devices, partial desalination or complete desalina-
tion cartridges, a local shut-off device, a local particulate filter, a local non-
return device and a local vacuum breaker must be provided by the own-
er/operator.
•Unless stated to the contrary, a minimum flow pressure of 2.5 bar and a maxi-
mum flow pressure of 5 bar must be guaranteed by the owner/operator.
•It is possible to clean the dirt screens without turning off the
main water supply. The water supply is automatically cut
off when the lower component in which the screen is locat-
ed is unscrewed. This enables the screen to be cleaned
during maintenance.
Information on the water quantities, quality and tempera-
tures needed can be found in the installation plan.
The water quality must also comply with the requirements of the Commercial Dish-
Washing Association. (http://www.vgg-online.de.)
Keep the feed water temperature of the water line supplying the final rinse compo-
nents to a minimum to achieve optimum results with potentially installed heat re-
covery components.
Other manuals for UPster K
1
Table of contents
Other Meiko Dishwasher manuals

Meiko
Meiko b-tronic User manual

Meiko
Meiko M-iClean H series User manual

Meiko
Meiko DV 200.2 Quick start guide

Meiko
Meiko K-200 Quick start guide

Meiko
Meiko K-Tronic User manual

Meiko
Meiko FV 40.2 User manual

Meiko
Meiko KA 15 User manual

Meiko
Meiko K160 User manual

Meiko
Meiko M-iClean U User manual

Meiko
Meiko FV 28 G-M User manual

Meiko
Meiko M-iClean U User manual

Meiko
Meiko FV 130.2 Quick start guide

Meiko
Meiko DV 80.2 Quick start guide

Meiko
Meiko K-44E Quick start guide

Meiko
Meiko DV 200.2 Quick start guide

Meiko
Meiko FV 40.2 Quick start guide

Meiko
Meiko M-iQ User manual

Meiko
Meiko EcoStar 430 F-MIKE User manual

Meiko
Meiko M-iClean U Series Quick guide

Meiko
Meiko FV 40.2 User manual