  9. Metel FIWRE-S-PDS User manual

Metel FIWRE-S-PDS User manual

REV-202005
Optic Fiber Converters ABI, MB SECURE,
PARADOX EVO, SATEL INTEGRA Buses FIWRE-S-PDS
SM/MM CWDM
www.metel.eu 1/8 www.iplog.eu
+13,85V
BLK.
GRN.
YEL.M2M1 M3
+13,85V
BLK.
GRN.
YEL.M2M1 M3
+13,85V
BLK.
GRN.
YEL.M2M1 M3
+13,85V
BLK.
GRN.
YEL.M2M1 M3
+13,85V
BLK.
GRN.
YEL.M2M1 M3
+13,85V
BLK.
GRN.
YEL.M2M1 M3
+13,85V
BLK.
GRN.
YEL.M2M1 M3
+13,85V
BLK.
GRN.
YEL.M2M1 M3
+13,85V
BLK.
GRN.
YEL.M2M1 M3
+13,85V
BLK.
GRN.
YEL.M2M1 M3
PRODUCT NAME CODE SUPPLY
Holder for Mounting to DIN35 and Flat Surfaceis Included.
v Digital Modulation
v 1x SC/PC Optical Port
v 2x Data BUS
v 1x Relay LOCK NO/NC
v Overvoltage Protection
v Current Limiter in Supply
v Working Temperature from – 40°C to +70°C
v Operating Range of Components –40°C to +85°C
FIWRE-S-PDS 1-004-290 10-20VDC(1)
TDW-S-PDS-BOX/12 1-504-290 10-20VDC(1)
RDW-S-PDS-BOX/12 1-604-290 10-20VDC(1)
RED.
TDW-S-PDS
BLK.
GRN.
YEL.
1x MM/SM1
+KPD
TDW-S-PDS
COM.
CKM.
DTM.
1max. 5/5km (MM/SM)
2max. 5/10km (MM/SM)
DT1
CK1
BUS1
BUS2
BUS1
BUS2
(1) Bus Power Supply
Connection to the M-BUS of ABI System compatibility
Connection to the bus of SATEL INTEGRA System compatibility
Panel RDW-S-PDS
Panel RDW-S-PDS
System keyboards and modules
RED.
TDW-S-PDS
BLK.
GRN.
YEL.
Connection to the BUS2 of MB SECURE System compatibility
Panel RDW-S-PDS
1x MM/SM1
RED.
TDW-S-PDS
BLK.
GRN.
YEL.
Connection to the BUS of PARADOX EVO System compatibility
Panel RDW-S-PDS
System keyboards and modules
System keyboards and modules
System keyboards and modules
Vertical Mounting to DIN35Mounting to a Flat Surface
REV-202005
Optic Fiber Converters ABI, MB SECURE,
PARADOX EVO, SATEL INTEGRA Buses FIWRE-S-PDS
SM/MM CWDM
www.metel.eu 2/8 www.iplog.eu
Parameter Value Unit Note
Optics Output Optical Power –14 to –8 / –10 to 0 dBm SM / MM
BUS Overvoltage Protections 600 W Pulse 10/1000 μs
Optical Fibres 1x SM9/125 - SC connectors µm Grinding PC
Sensitivity –31 dBm SM / MM
LOCK Relay RDW-S-PDS NO/NC Contact with max. 125VAC/0.5A or 60VDC/0.3A
1x MM 50(62.5)/125 - SC conn. µm Grinding PC
Power Suply Voltage 10-20 VDC From Bus
NO Contact Closed = Communication OK
Protections Overvoltage/ Current 600W-Pulse 10/1000 μs / Reversible
Current at 12VDC Max. 100 mA
Humidity Max. 95 % Non-condensing
Environment Operational Tange –40..+70 °C Temperature of Environment
Parameters Weight typ: 0.2 kg
Mechanical Dimensions - w / h / l 110 x 97 x 30 (37) mm With the DIN Holder
The producer retains the right to change any technical parameterswithout previous written or published notification.
Description and Technical Parameters compatibity
These fibre optic converters are designed for the transmission of system buses of the control panels. ABI PKE, MB SECURE
HONEYWELL, PARADOX EVO a SATEL INTEGRA.
Optical Range ABI 5/10 km SM / MM
SATEL INTEGRA 5/5 km SM / MM
PARADOX EVO 5/5 km SM / MM
ATTENTION: The Converters Contain Class 1 Laser Sources According to EN 60825-1-1
Recommended Topology compatibility
When designing a topology, we recommend keeping to the topology of the bus and not making more
than a 1 meter branch from the bus. Any longer turns can result in communication reflections and
increased susceptibility to interference. In the diagram below are suggested additional restrictions on the
transfer of the optical fiber and the use of multiple optical converters..
Panel
MB SECURE 5/10 km SM / MM
MxMxMx
Mx
Mx
Mx
RDW TDW
MxMxMx
Mx
TDW
Other restrictions on optical transmission
Maximum number of RDW + TDW pairs connected in series = 3
Maximum number of RDW + TDW pairs connected in parallel = 3
RDW
RDW
ABI, MB - max. 5/10km (MM/SM)
PARADOX, SATEL - max. 5/5km (MM/SM)
REV-202005
Optic Fiber Converters ABI, MB SECURE,
PARADOX EVO, SATEL INTEGRA Buses FIWRE-S-PDS
SM/MM CWDM
www.metel.eu 3/8 www.iplog.eu
REVISION: 201602 – Pre-production Version
201603 – Production Version
202001 – Supporting ABI, MB-SECURE
Dimension universality
REV-202005
Optic Fiber Converters ABI, MB SECURE,
PARADOX EVO, SATEL INTEGRA Buses FIWRE-S-PDS
SM/MM CWDM
www.metel.eu 4/8 www.iplog.eu
-
13,85VDC
+
TDW-S-PDS
TDW-S-PDS
BUS1 BUS2
T YPE : TD W-S-PDS-BO X/1 2
TYPE: RDW-S-PDS-BO X/12
COD E: 1 -504-290
COD E: 1-604 -2 90
GND
DA TA
CLK
V+
Rx/ Tx -BUS 1
GND
DA TA
CLK
V+
Rx/ Tx -BUS 2
RDW-S-PDS
BUS1 BUS2
T YPE : TD W-S-PDS-BO X/12
TYPE: RDW-S-PDS-BO X/12
COD E: 1-5 04 -290
COD E: 1-604 -2 90
GND
DA TA
CLK
V+
Rx/ Tx -BUS 1
GND
DA TA
CLK
V+
Rx/ Tx -BUS 2
LOCK
N.O.
COM
N.C.
Zentrale
12V UB 0V GND DA DATEN
Netzeil
12V/DC
Teilnehmer
12V UB 0V GND DA DATEN
Connection to the M-BUS of ABI System compatibility
REV-202005
Optic Fiber Converters ABI, MB SECURE,
PARADOX EVO, SATEL INTEGRA Buses FIWRE-S-PDS
SM/MM CWDM
www.metel.eu 5/8 www.iplog.eu
Connection to the BUS2 of MB SECURE System compatibility
2x BUS2
1x MM/SM
2x BUS2
Door
Modules
Concentrators
Touchpanels
Max. 10 km (SM 9/125µm).
Max. 5 km (MM 50/125µm).
LEGEND:
1x MM / SM Fibre
Bus BUS2
Other
RDW-S-PDS TDW-S-PDS
MB-SECURE
Concentrators
Sensors
REV-202005
Optic Fiber Converters ABI, MB SECURE,
PARADOX EVO, SATEL INTEGRA Buses FIWRE-S-PDS
SM/MM CWDM
www.metel.eu 6/8 www.iplog.eu
RED BLK GRN YEL
Max. 5km SM / MM
-
12VDC
+
RDW-S-PDS
TDW-S-PDS
RED BLK GRN YEL
max. 300m
max. 300m
Connection to the BUS of PARADOX EVO System compatibility
TDW-S-PDS
BUS1 BUS2
T YP E: TD W-S-P DS -BO X/12
TYPE: RDW-S-PDS-BO X/12
COD E: 1 -504-290
COD E: 1-604 -2 90
GND
DA TA
CLK
V+
Rx/ Tx -BUS 1
GND
DA TA
CLK
V+
Rx/ Tx -BUS 2
BUS1 BUS2
T YP E: TD W-S-P DS -BO X/12
TYPE: RDW-S-PDS-BO X/12
COD E: 1-5 04 -290
COD E: 1-604 -2 90
GND
DA TA
CLK
V+
Rx/ Tx -BUS 1
GND
DA TA
CLK
V+
Rx/ Tx -BUS 2
LOCK
N.O.
COM
N.C.
REV-202005
Optic Fiber Converters ABI, MB SECURE,
PARADOX EVO, SATEL INTEGRA Buses FIWRE-S-PDS
SM/MM CWDM
www.metel.eu 7/8 www.iplog.eu
+KPD COM CKM DTM
Max. 5km SM / MM
-
12VDC
+
RDW-S-PDS
TDW-S-PDS
EXPANDER
+12V COM DAT CLK
EXPANDER
EXPANDER
max. 300m
COM +KPD DTM CKM DT1 CK1
max. 300m
Connection to the bus of SATEL INTEGRA System compatibility
BUS1 BUS2
T YP E: TD W-S-P DS -BO X/12
TYPE: RDW-S-PDS-BO X/12
COD E: 1-504 -2 90
COD E: 1-6 04 -290
GND
DA TA
CLK
V+
Rx/ Tx -BUS 1
GND
DA TA
CLK
V+
Rx/ Tx -BUS 2
LOCK
N.O.
CO
M
N.C.
TDW-S-PDS
BUS1 BUS2
T YP E: TD W-S-P DS -BO X/12
TYPE: RDW-S-PDS-BO X/12
COD E: 1 -504-290
COD E: 1 -604-290
GND
DA TA
CLK
V+
Rx/ Tx -BUS 1
GND
DA TA
CLK
V+
Rx/ Tx -BUS 2
Quick Installation Manual REV:202005
FIWRE-S-PDS
Optoconverters ABI, MB SECURE, PARADOX EVO, SATEL INTEGRA Buses
www.metel.eu 8/8 www.iplog.eu
1. Mounting
Place the RDW-S-PDS to the side of the alarm system.
Place the TDW-S-PDS to the side of the modules (keyboards,
modules...).
Mount the converters to either a flat surface or the DIN35
rail.
2. Connect Supply
12VDC from bus on the panel side and from the DC source on
the module side between V + and GND terminals, the power
supply connection is signaled by the yellow POWER LED.
&The converters include overvoltage protections on
data ports and power supply providing sufficient protection
of the converters against overvoltage in the LPZ1 and LPZ2
zones. In the case of installation of transmitters in an
outdoor environment (zones LPZ0A and LPZ0B), we
recommend placing them in switchboards providing
electromagnetic shielding. Further information on this issue
can be found at www.metel.eu in the document "Surge
protection of IP CCTV system according to EN 62305".
3. Connect Optic Fiber
Terminated by a SC connector (grinding PC). After
interconnection of the TDW-S-PDS and the RDW-S-PDS LED
LOCK switches off. The max. length of the optical fiber is:
- MM/SM - 5/5 km for systems PARADOX EVO and
SATEL INTEGRA,
- MM/SM – 5/10km for systems ABI and MB SECURE.
&The optical path used must meet the minimum
technical requirements specified on www.metel.eu in the
document "xDW - minimum requirements for the quality of
the optical path". Failure to comply with these requirements
may result in a significant reduction in the quality of
communication.
4. Connect Signal Wires
Proceed according to the type of alarm system with the
pictures on the previous pages.
Connect the data lines from the alarm system to TDW-S-
PDS to terminals DATA and CLK.
5. Indications
LED PWR - by switching on detects supply
LED LOCK - by switching on detects relay closure
- by switching on detects optics interruption
- by switching on detects failure of a remote
device
LED Rx/Tx1 - data line
- red LED Tx blinking –data transmission
- green LED Rx blinking – data reception
LED Rx/Tx2 - data line
- red LED Tx blinking – data transmission
- green LED Rx blinking – data reception
&The conversion of data from the metallic line to
the optics and back is completely transparent. The
converters do not contain any firmware that would
process the data in any way. Therefore, the converters
do not require any special configuration. Their
installation and commissioning arevery simple and fast.
TDW-S-PDS
Tx - 1310nm
Rx - 1550nm
RDW-S-PDS
Tx - 1550nm
Rx - 1310nm
GROUND
DATA BUS2 <
+10-20VDC
RELAY
max. 125VAC / 0.5A
max. 60VDC / 0.3A
WHERE THERE IS
- LOCAL DEVICE IN DE-ENERGIZED STATE
- REMOTE DEVICE IS IN FAILURE
- FIBRE IS CORRUPTED
COM AND NC ARE CONNECTED.
WHEN IS DEVICE IS WORKING
- FIBRE IS OK
COM AND NO ARE CONNECTED.
GROUND
DATA BUS1 <
+10-20VDC
BUS1 BUS2
TYPE: TDW-S-PDS-BOX/12
TYPE: RDW-S-PDS-BOX/12
CODE: 1-504-290
CODE: 1-604-290
GND
DATA
CLK
V+
Rx/Tx-BUS1
GND
DATA
CLK
V+
Rx/Tx-BUS2
LOCK
N.O.
COM
N.C.

This manual suits for next models

5

Other Metel Media Converter manuals

Metel 2G-1S.1.0 User manual

Metel

Metel 2G-1S.1.0 User manual

Metel BREAK-DW-S-4C Series User manual

Metel

Metel BREAK-DW-S-4C Series User manual

Popular Media Converter manuals by other brands

Westermo LRW-702-F2 user guide

Westermo

Westermo LRW-702-F2 user guide

Massoth eMOTION 8FL manual

Massoth

Massoth eMOTION 8FL manual

Hengstler AX71 Series installation instructions

Hengstler

Hengstler AX71 Series installation instructions

Chord Hugo M Scaler manual

Chord

Chord Hugo M Scaler manual

TR-Electronic CDV582 user manual

TR-Electronic

TR-Electronic CDV582 user manual

D-Link DMC-920 user guide

D-Link

D-Link DMC-920 user guide

bolid USB-RS232 user manual

bolid

bolid USB-RS232 user manual

Advantech Wireless SSPBMg-C400-BRE Installation and operating manual

Advantech Wireless

Advantech Wireless SSPBMg-C400-BRE Installation and operating manual

Addonics Technologies AAT18ZIF25 user guide

Addonics Technologies

Addonics Technologies AAT18ZIF25 user guide

AJA HD10A-Plus Installation & operation guide

AJA

AJA HD10A-Plus Installation & operation guide

National Semiconductor ADC10080 manual

National Semiconductor

National Semiconductor ADC10080 manual

EYC DST01 Operation manual

EYC

EYC DST01 Operation manual

Transition Networks E-CX-TBT-04 user guide

Transition Networks

Transition Networks E-CX-TBT-04 user guide

Bolin Technology Visca VCC-BL-VNS-07202020 user manual

Bolin Technology

Bolin Technology Visca VCC-BL-VNS-07202020 user manual

Lika ROTAPULS C58A Series Mounting instructions

Lika

Lika ROTAPULS C58A Series Mounting instructions

MRC 0001922 manual

MRC

MRC 0001922 manual

Eyeheight AR-2n user manual

Eyeheight

Eyeheight AR-2n user manual

BARIX INSTREAMER ICE Quick install guide

BARIX

BARIX INSTREAMER ICE Quick install guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.