1.Product Description
The MET200 is a single phase 60A two wire prepayment keypad integrated-type STS
sub- meter, with IEC62055-compliant data encryption .
It has a built- in relay with advanced anti- tamper functions.
2. Features and Technical Parameters
2.1 Features
• Numeric keypad for inputting 20 - digit STS tokens and Short Codes
• Keypad lifetime > 25000 inputs (multiple LAB tests)
• Full events record with optical interface
• Low balance credit and emergency LED
• LCD display
• Internal 60A relay
• Over load protection
• Terminal cover tamper protection
• Meter supports IR communication
• RoHS compliant
• CE approved
2.2 Technical Parameters
Voltage:
Current:
Accuracy class:
Standard:
Frequency:
230V
5(60) A
1.0
IEC62052- 11,IEC62053-21,IEC62056-21,IEC62055-41
50Hz
1

Impulse constant:1 0 0 0 imp/ kWh
Display: LCD 6+2
Power consumption: ≤10VA ≤1W
Starting current: 0.4%Ib
Temperature range: - 2 0 ~ 7 0 ℃
Average humidity value: 75%
Maximal value: 95%
Communication: IR IEC6 2 0 5 6 - 2 1 A Mode
3. Description
3.1
Description of Meter
A
B
E
low credit alarm indicator
pulse indicator
3*4 keypad
LCD
IR communication interface pulse
output
C
F
D
A
B
C
D
E
F

4. Display
4.1 LCD display
Symbol
Description
Power Reverse
Tampering status
Relay open
Present power
5. Connection Diagram

6. Dimensions
6.1 Meter Dimensions
Height
Width
Depth
171.5mm
106.0mm
54.7mm
7. Software
7.1.1 Short Codes - Meter Programming
a. Set Alarm Credit: input 456XX-enter.
where XX is alarm credit ( kWh), no decimal, setting, range is 5-9 9 kWh
b. Alarm Buzzer Interval: input 1 2 3 XXX- enter.
XXX is interval (minutes), setting range is 0-999 minutes.
c. Emergency overdraft Credit: input 23451 0 -enter
Overdraft is 10kWh.
Note: This process will fail when the balance credit is more than 0 .
d. Set low voltage alarm: Input XXX125-enter where XXX is voltage (V).
e. Set low current alarm: Input XXX246-enter where XXX is current (A).

7.1.2 Short Codes - Queries
Code
Description
Code
Description
00
Test LCD display
59
Last credit kWh
01
Test the load switch
60
Last 2nd credit kWh
02
Test the Display
61
Last 3rd credit kWh
03
Total kWh register
62
Last 4th credit kWh
04
KRN & KT
63
Last 5th credit kWh
05
TI
64
Total technical tokens accepted
06
EEPROM error code
65
Last technical token accepted
07
Display power limit, kW
66
Last 2 ’ rd technical token accepted
08
Tampering status
67
Last 3 ’ rd technical token accepted
09
Instantaneous power
68
Total trip because over load times
10
Display software version
69
Total power source off times
37
Remaining Credit ( kWh)
70
Total terminal cover open times
38
Total recharge kWh
71
Total meter cover open times
39
Power Factor( PF)
73
Overdraft energy
40
Apparent power
74
Hardware version
41
Rms voltage (V)
75
Meter ID No.
44
Rms current (A)
76
Meter Constant
47
Instantaneous power ( W)
77
Supply Group Code ( SGC)
53
Total number of
tokens accepted
78
Alarm Duration time
54
Last credit token accepted
79
Alarm Low Credit limit
55
Last 2nd credit token
accepted
81
Remain kWh allowed using time
(hour/day)
56
Last 3 rd credit token accepted
90
Low voltage
57
Last 4 th credit token accepted
91
High voltage
58
Last 5 th credit token accepted

7.2 Events Record
※Last 50 recharges - token codes
※Last 50 recharges - credit
※Last 50 recharges - technical tokens
※Recharges - total quantity
※Overload events - total quantity
※Power-off events - total quantity
※Terminal cover open - quantity
※Top cover open - quantity
※Last 50 technical tokens
※Total number of technical tokens
Note: The maximum number of the above events is 60,000.
Yellow LED will light and LCD will display information as below table.
Tampering Type
Meter status
Symbol
display
Normalization
Open the terminal cover
when meter is working
Relay open
Data record
Token
Reverse current
Meter measures
normally
Data record
Repair
7. 3 Metro Code (token) prepayment function
Recharge:
After purchasing a recharge token, enter the 2 0- digit token into keypad
The token will scroll display from right to left. The typing time interval should within 20
seconds. Type " back button " to modify an input error.
After correct token entry, press “Enter” .
If full Metro Code is not entered, code will not accept.
If the TOKEN is accepted, the LCD will display corresponding code.
Error Codes:
Err-40: Invalid subclass
Err-45: expired key
Err- 47: not permitted to purchase electricity in this mode
Err- 48 : inconformity to key modify process
Err-49: this data is not used by meter
Err-53 :setting key overtime
Err-5 9 : the balance exceeds the allowed power and this recharge is not valid

Press short code 8, LCD display instruction for tampering status:
1 : terminal cover has been opened before
2 : terminal cover has been opened before when power off
3 : phase reverse
If all these tampering status exist at the same time, then LCD will display these numbers at the
same time.
Successful code:
Good- 01 :key modification, Token 1 decode successfully(if input Token 1 first)
Good- 02 :key modification, Token 2 decode successfully(if input Token 2 first)
Good :set alarming delay successfully
Good :set alarming kWh successfully
If recharge successfully, LCD will display below 3 pages:
Good : TOKEN accept
123 : recharge value this time
1234: total recharge value for this meter
7.4 Overload process
The relay will open when the overload lasts for 45 sec and close after 150 seconds.
If the above situation re-occurs 5 times in 30 minutes, the relay will close again after 4 5 minutes.
If overloads are less than (eg. 4) in 30 minutes, the recovery time of the relay will be 150 seconds,
and this record will be cleared unless repeated in the next 30 minutes. The overload value can be
set through keypad or PC software.
7.5 Relay off when voltage is abnormal:
When the voltage is very low or high, the meter relay will open in order to protect the electric
equipment, the low/ high voltage limit value can be set through keypad or communication, the
permitted setting range is 120-290VAC, and the tolerant range in the meter is 130-253VAC.
Details as below:
1 . Low voltage relay off: when the meter detects the voltage in electricity grid is lower than

130V for 10 seconds, relay will open, and then LCD shows “Err-VL”, only when the voltage rise to
over 140V, relay will close.
2. High voltage relay open: when the meter detects the voltage in electricity grid is higher than 253V
for 10seconds, relay will open, and then LCD shows “Err-VH”, only when the voltage drops to lower
than 243V, relay will close.
7.6 Credit Balance alarm
This meter has the function of class 1 credit balance alarm. It could be set through short code or
communication. When the credit balance is less than the limit, the red LED will flicker. It could be
cleared up by pressing any button but it will flicker again after a time interval. The interval can be set
through short code or communication. After credit is fully used, the red LED will display all the time.
8 Safety Instructions
Information for Your Own Safety
This manual does not contain all of the safety measures for operation of this equipment (module,
device) because special operating conditions, local code requirements or local regulations may
necessitate further measures. However, it does contain information which must be adhered to for your
own personal safety and to avoid damage to the equipment. This information is highlighted by a
warning triangle with an exclamation mark or a lightning bolt depending on the severity of the warning.
Warning
Means that failure to observe the instruction can result in death, serious injury or considerable
material damage.
Caution
Risk of electric shock and failure to take the necessary safety precautions will result in death,
serious injury or considerable material damage.

Installation by Qualified Professional
Installation and operation of Metro sub- meters may only be performed by qualified professionals
Meter installation should be accompanied by a Certificate of electrical Compliance
Use for the intend purpose
The equipment (device, module) may only be used for the application cases specified in the
catalog and the user manual and only in connection with devices and components recommended
and approved by YTL.
Exclusion of liability
Whilst we have taken every precaution to ensure the accuracy of the information in this User
Manual, we don’t warrant that it is error free and disclaim any liability for errors or omissions.
Warranty
Metro meters carry a 1 year factory warranty. see our website for more details.
https://metroprepaid.co.uk/
Technical support
Tel
WhatsApp
Email :
Web chat
020 3020 1144
020 3020 1145
help@ metroprepaid. co. uk
www. metroprepaid. co. uk
Metro Prepaid Help Desk - 24 Hours
Table of contents
Other Metro DataVac Measuring Instrument manuals