Microchip Technology PD-9601-zzGC/AC User manual

PD-9601-zzGC/AC
Power over Ethernet Single-port Midspan User Guide
Introduction
Microchip’s family of PD-9601-zzGC Power over Ethernet (PoE) Midspans includes the PD-9601-10GC,
PD-9601‑5GC, and PD-9601-25GC models. Throughout this document, these three models are referred as the
PD-9601-zzGC.
The PD-9601-zzGC is a PoE Single Port Midspan/Injector that offers a compact and cost-effective power solution
for WLAN access points, network cameras, and other IP terminal installations. The PD-9601-zzGC inject power over
data‑carrying Ethernet cabling. The PD-9601-zzGC PoE Midspan/ Injector is IEEE® 802.3bt compliant and supplies
54 VDC to 4-pair wires (Alt A: 1, 2 (-) and 3, 6 (+)\Alt B: 4, 5 (+) and 7, 8 (-)) of a standard Ethernet cable in category
5E and above (for 2.5G), and category 6 and above (for 5G and 10G) enables delivery of both data and power to the
IP terminal. The PD-9601-zzGC can be powered through universal AC input and can provide up to 90W.
Features
PD-9601-zzGC PoE Midspan has the following key features:
• Single-Port PoE Output
• Guaranteed Power of 90W
• Compact Product Size
• Universal AC Input: 100 VAC to 240 VAC
• Standard Compliance: IEEE 802.3bt
• 10, 5, and 2.5 Gbps Pass-Through Data Rates
© 2022 Microchip Technology Inc.
and its subsidiaries
User Guide DS50003257A-page 1

Table of Contents
Introduction.....................................................................................................................................................1
Features.................................................................................................................................................. 1
1. Standards and Safety Guidelines............................................................................................................3
1.1. Part Number Definition.................................................................................................................3
1.2. Electrical Compatibility Approvals................................................................................................ 3
1.3. Safety Standard Approvals...........................................................................................................3
1.4. GS Marking.................................................................................................................................. 3
1.5. Safety Information........................................................................................................................ 4
2. Information en Matière de Sécurité......................................................................................................... 5
2.1. Directives Générales....................................................................................................................5
2.2. Mises en Garde............................................................................................................................5
3. PoE Midspan Installation.........................................................................................................................6
3.1. Connecting Ethernet Cables........................................................................................................ 6
3.2. Indicators......................................................................................................................................6
4. Troubleshooting.......................................................................................................................................7
4.1. Preliminary Steps......................................................................................................................... 7
4.2. Troubleshooting Steps..................................................................................................................7
5. Specifications.......................................................................................................................................... 8
5.1. Physical Specifications.................................................................................................................8
5.2. Environmental Specifications....................................................................................................... 8
5.3. Electrical Specifications................................................................................................................8
6. Contacting Technical Support................................................................................................................. 9
7. Revision History.................................................................................................................................... 10
The Microchip Website................................................................................................................................. 11
Product Change Notification Service............................................................................................................11
Customer Support........................................................................................................................................ 11
Microchip Devices Code Protection Feature................................................................................................ 11
Legal Notice................................................................................................................................................. 12
Trademarks.................................................................................................................................................. 12
Quality Management System....................................................................................................................... 13
Worldwide Sales and Service.......................................................................................................................14
PD-9601-zzGC/AC
© 2022 Microchip Technology Inc.
and its subsidiaries
User Guide DS50003257A-page 2

1. Standards and Safety Guidelines
The following sections mention the standard and safety guidelines for the product.
1.1 Part Number Definition
PD-9601-zzGC: AC input family.
Table 1-1. Part Number Definition
Symbol Description
zzGC Represents the bandwidth (zz—10, 5, or 2.5 Gbps).
AC Midspan has AC input.
1.2 Electrical Compatibility Approvals
Microchip’s PD-9601-zzGC Midspans complies with the following standards:
•FCC Part 15: Class B
• EN 55032: Class B
• Canadian ICES-003
• EN55035
• VCCI
1.3 Safety Standard Approvals
Microchip’s PD-9601-zzGC Midspans meets the following safety standards. Consult Microchip for a complete list of
safety certifications.
•UL/IEC/EN 62368-1
• GS Compliance
1.4 GS Marking
GS marking on this product indicates that the product complies with the German Product Safety Act.
PD-9601-zzGC/AC
Standards and Safety Guidelines
© 2022 Microchip Technology Inc.
and its subsidiaries
User Guide DS50003257A-page 3

1.5 Safety Information
Read the safety information before using the PoE Midspan unit.
1.5.1 General Guidelines
Read the following safety information before carrying out any installation, removal, or maintenance procedure on the
PoE Midspan. Warnings contain directions to be followed for the safety of personal and product.
1.5.2 Warnings
• Read installation instructions in 3. PoE Midspan Installation before connecting Midspan to its power source.
• Read instructions in 3. PoE Midspan Installation before connecting Midspan-to-Midspan power backup.
• Only trained and qualified personnel must be allowed to install, replace, and service this equipment.
• This ITE device must be connected to PoE (power supply over Ethernet) networks only, without routing to other
networks.
• The power cord must not be attached to the surface of the building or pass-through walls, ceilings, floors, and
similar openings in the building structure.
• Steps must be taken to prevent physical damage to the power cord, including proper routing.
• This product relies on building installation for short-circuit (over-current) protection. Use only a fuse or circuit
breaker not higher than 15A for 120 VAC (U.S.) or 10A for 230 VAC (international).
• All wiring and connections must conform to NFPA 70 (NEC).
• Do not work on the system or connect/disconnect cables during lightning storms.
• A voltage mismatch can damage the equipment and can pose a fire hazard. If voltage indicated on the label is
different from the power outlet voltage, do not connect Midspan to this outlet.
• For shelf-mounted equipment, verify that surface is stable and strong enough to support the equipment. Do not
stack more than four Midspan units.
• When disposing this product, follow all local laws and regulations.
•Data and Data and Power ports of the Midspan are shielded RJ-45 data sockets. They cannot be used as Plain
Old Telephone Service (POTS) sockets. Only connect RJ-45 data connectors to these sockets.
• Associated Ethernet wiring must be limited to the inside of the building.
PD-9601-zzGC/AC
Standards and Safety Guidelines
© 2022 Microchip Technology Inc.
and its subsidiaries
User Guide DS50003257A-page 4

2. Information en Matière de Sécurité
Lire les informations suivantes en matière de sécurité avant d'utiliser d'activer l'alimentation sur votre appareil
Ethernet Midspan.
2.1 Directives Générales
Lire les informations suivantes en matière de sécurité avant d'installer ou enlever quoi que ce soit, ou procéder à
l'entretien de l'alimentation de votre appareil Ethernet Midspan. Les mises en garde contiennent des instructions qui
doivent être suivies pour la sécurité des personnes et du produit. Suivre les instructions soigneusement.
2.2 Mises en Garde
• Lire les instructions d'installation dans la cette 3. PoE Midspan Installation avant de connecter le Midspan à une
source d'alimentation.
• Lire les instructions d'installation dans la cette 3. PoE Midspan Installation avant de connecter le Midspan à une
source de sauvegarde Midspan.
• Seul du personnel formé et qualifié doit être autorisé à installer, remplacer et entretenir cet équipement.
• Cet ITE appareil doit être branché à des réseaux PoE (alimentation électrique par Ethernet) seulement, et ce,
sans routage vers d'autres réseaux.
• Le cordon d'alimentation ne doit pas être fixé à la surface du bâtiment ni traverser les murs, les plafonds, les
planchers et les ouvertures similaires de la structure du bâtiment.
• Des mesures doivent être prises pour éviter tout dommage physique au cordon d'alimentation, y compris un
acheminement approprié.
• Ce produit dépend de l'installation électrique de l'immeuble pour une protection contre les courts-circuits
(surcharges de courant). Utiliser seulement un fusible ou un disjoncteur dont la puissance ne dépasse pas
15A pour 120VAC (É.-U.), ou 10A pour 230VAC (international).
• Tout le câblage et les connexions doivent être conformes à la norme NFPA 70 (NEC).
• Ne pas exécuter de travaux sur le système, connecter ou déconnecter des câbles pendant les orages.
• Une disparité de voltage peut endommager l'équipement et constituer un risque d'incendie. Si le voltage indiqué
sur l'étiquette est différent du voltage de la source d'alimentation, ne pas connecter le Midspan à cette prise.
• Pour un équipement monté sur une tablette, vérifier que la surface est stable et suffisamment solide pour le
supporter. Ne jamais empiler plus de quatre unités Midspan.
• Pour disposer/jeter ce produit, suivre les lois et règlements locaux.
• Les ports Data et Data et Power du PoE Midspan sont des prises de données blindées RJ45. Elles ne peuvent
pas être utilisées comme prises de service téléphonique traditionnel. Connecter seulement des connecteurs de
données RJ45 à ces prises. Le câblage Ethernet connexe doit être limité à l'intérieur de l'immeuble.
• Le câblage Ethernet associé doit être limité à l'intérieur du bâtiment.
PD-9601-zzGC/AC
Information en Matière de Sécurité
© 2022 Microchip Technology Inc.
and its subsidiaries
User Guide DS50003257A-page 5

3. PoE Midspan Installation
Follow the installation steps carefully:
1. Connect the PD-9601-zzGC to an AC outlet (100 VAC to 240 VAC).
2. Connect the Data In jack (input) to the remote Ethernet network switch's patch panel.
3. Connect the Power Out jack (output) to Terminal.
Figure 3-1. Installing the PD-9601-zzGC
Terminal Ethernet
Port
Output
Port
Input
Main LED
Indication
Terminal Ethernet
Port
Output
Port
Input
Main LED
Indication
3.1 Connecting Ethernet Cables
The ports on the PD-9601-zzGC Midspan are configured as Pass Through ports for conductors of RJ45 connectors.
Use Category 5e/6 cabling while making connections. See Figure 3-1.
1. Connect Ethernet 10/5/2.5G Base-T input (Ethernet) cable to RJ45 female socket on PD-9601-25\5GCO.
2. Connect Ethernet 10/5/2.5G Base-T, Plus 54 VDC output (Terminal) cable to RJ45 female socket, with DC
voltage on wire pairs, (Alt A: 1, 2 (-) and 3, 6 (+)\Alt B: 4, 5 (+) and 7, 8 (-)).
3.2 Indicators
The following table lists the set of indicators displaying the status of the PoE Midspan and its ports.
Table 3-1. Port Indicator LED
Port LED Color Port Load Conditions
Orange ON Power input is active
Orange Blinking Power input error
Blue ON Port ON—PoE over 2P
Blue Blinking Port error
Green ON Port ON—PoE over 4P
Green Blinking Port error
PD-9601-zzGC/AC
PoE Midspan Installation
© 2022 Microchip Technology Inc.
and its subsidiaries
User Guide DS50003257A-page 6

4. Troubleshooting
The following sections describe the troubleshooting procedures to address any problems with a unit.
4.1 Preliminary Steps
• Read installation instructions before connecting the PD-9601-zzGC to its power source.
• There is no ON/OFF switch on the PD, simply plug the PD-9601-zzGC into an AC power source.
• Verify that a PoE Ready Ethernet-compatible device is connected.
• Do not cover PD-9601-zzGC or block airflow to the unit with any foreign objects. Keep PD-9601-zzGC away
from excessive heat and humidity, and free from vibration and dust.
• Ensure that cable length from Ethernet network source to the terminal does not exceed 100 meters (330 feet).
This Midspan is not a repeater and does not amplify Ethernet data signal.
• Use a splitter, if necessary, and ensure that the splitter is connected near the terminal and not on the PD-9601-
zzGC.
4.2 Troubleshooting Steps
The following table lists problem and resolution sequences to assist in troubleshooting minor operating problems. If
the following steps do not solve your problem, contact the dealer for further assistance.
Table 4-1. Troubleshooting Steps
Problem Corrective Steps
Midspan does not power-up. 1. Verify that an approved power cord is used.
2. Ensure that power cord is properly connected.
3. Verify that the voltage at the power inlet is between 100 VAC to 240 VAC.
4. Remove and re-apply power to the device and check indicators during power-
up sequence.
A port indicator is not lit and
corresponding PD does not
operate.
1. Verify that the PD is designed for PoE operation according to IEEE 802.3bt
standard.
2. Verify that you are using a standard straight‑wired four-pair cable (UTP/FTP
Category 5e/6).
3. Verify that the PD is connected to the PD-9601-zzGC Terminal port.
4. If an external power splitter is in use, replace it with a viable splitter.
5. Remove and re-apply power to the Midspan.
End device operates but
there is no data link.
1. Verify that for this link you are using a standard UTP/FTP Category 5e/6
straight (non-crossover) cabling, with all four pairs, and that link is 100 meters
long.
2. Verify that the Ethernet cable length is less than 100 meters from Ethernet
source to load/remote terminal.
3. Ensure that the input Ethernet cable is connected to the power injector’s
Ethernet port.
4. If an external power splitter is in use, replace it with a viable splitter.
PD-9601-zzGC/AC
Troubleshooting
© 2022 Microchip Technology Inc.
and its subsidiaries
User Guide DS50003257A-page 7

5. Specifications
The following sections describe unit specifications of PD-9601-zzGC unit.
5.1 Physical Specifications
Table 5-1. Dimensions
Parameter Dimensions
In mm In inch
Height 48.6 1.91
Width 84.4 3.32
Length 162.1 6.38
Table 5-2. Physical Specifications
Part Number Weight
PD-9601-zzGC 550 g (1.21 lb)
5.2 Environmental Specifications
Table 5-3. Environmental Specifications
Mode Temperature Humidity
Operating 0°C to 40°C
32°F to 104°F
90% (non-condensing)
Storage –20°C to 70°C
–4°F to 158°F
95% (non-condensing)
5.3 Electrical Specifications
Table 5-4. Electrical Specifications
Parameter Value
Input voltage 100 VAC to 240 VAC (50/60 Hz)
Input current 1.6A
Available output power (maximum) 90W
Nominal output voltage 54 VDC
PD-9601-zzGC/AC
Specifications
© 2022 Microchip Technology Inc.
and its subsidiaries
User Guide DS50003257A-page 8

6. Contacting Technical Support
If you encounter any problems while installing or using this product, consult Microchip technical support team through
the website or contact on the following number:
USA/Canada
Telephone: +1 877 480 2323
Internet: www.microchip.com/support
PD-9601-zzGC/AC
Contacting Technical Support
© 2022 Microchip Technology Inc.
and its subsidiaries
User Guide DS50003257A-page 9

7. Revision History
Revision Date Description
A 01/2022 Initial Revision
PD-9601-zzGC/AC
Revision History
© 2022 Microchip Technology Inc.
and its subsidiaries
User Guide DS50003257A-page 10

The Microchip Website
Microchip provides online support via our website at www.microchip.com/. This website is used to make files and
information easily available to customers. Some of the content available includes:
•Product Support – Data sheets and errata, application notes and sample programs, design resources, user’s
guides and hardware support documents, latest software releases and archived software
•General Technical Support – Frequently Asked Questions (FAQs), technical support requests, online
discussion groups, Microchip design partner program member listing
•Business of Microchip – Product selector and ordering guides, latest Microchip press releases, listing of
seminars and events, listings of Microchip sales offices, distributors and factory representatives
Product Change Notification Service
Microchip’s product change notification service helps keep customers current on Microchip products. Subscribers will
receive email notification whenever there are changes, updates, revisions or errata related to a specified product
family or development tool of interest.
To register, go to www.microchip.com/pcn and follow the registration instructions.
Customer Support
Users of Microchip products can receive assistance through several channels:
• Distributor or Representative
• Local Sales Office
• Embedded Solutions Engineer (ESE)
• Technical Support
Customers should contact their distributor, representative or ESE for support. Local sales offices are also available to
help customers. A listing of sales offices and locations is included in this document.
Technical support is available through the website at: www.microchip.com/support
Microchip Devices Code Protection Feature
Note the following details of the code protection feature on Microchip devices:
• Microchip products meet the specifications contained in their particular Microchip Data Sheet.
• Microchip believes that its family of products is secure when used in the intended manner and under normal
conditions.
• There are dishonest and possibly illegal methods being used in attempts to breach the code protection features
of the Microchip devices. We believe that these methods require using the Microchip products in a manner
outside the operating specifications contained in Microchip’s Data Sheets. Attempts to breach these code
protection features, most likely, cannot be accomplished without violating Microchip’s intellectual property rights.
• Microchip is willing to work with any customer who is concerned about the integrity of its code.
• Neither Microchip nor any other semiconductor manufacturer can guarantee the security of its code. Code
protection does not mean that we are guaranteeing the product is “unbreakable.” Code protection is constantly
evolving. We at Microchip are committed to continuously improving the code protection features of our products.
Attempts to break Microchip’s code protection feature may be a violation of the Digital Millennium Copyright Act.
If such acts allow unauthorized access to your software or other copyrighted work, you may have a right to sue
for relief under that Act.
PD-9601-zzGC/AC
© 2022 Microchip Technology Inc.
and its subsidiaries
User Guide DS50003257A-page 11

Legal Notice
Information contained in this publication is provided for the sole purpose of designing with and using Microchip
products. Information regarding device applications and the like is provided only for your convenience and may be
superseded by updates. It is your responsibility to ensure that your application meets with your specifications.
THIS INFORMATION IS PROVIDED BY MICROCHIP “AS IS”. MICROCHIP MAKES NO REPRESENTATIONS
OR WARRANTIES OF ANY KIND WHETHER EXPRESS OR IMPLIED, WRITTEN OR ORAL, STATUTORY
OR OTHERWISE, RELATED TO THE INFORMATION INCLUDING BUT NOT LIMITED TO ANY IMPLIED
WARRANTIES OF NON-INFRINGEMENT, MERCHANTABILITY, AND FITNESS FOR A PARTICULAR PURPOSE
OR WARRANTIES RELATED TO ITS CONDITION, QUALITY, OR PERFORMANCE.
IN NO EVENT WILL MICROCHIP BE LIABLE FOR ANY INDIRECT, SPECIAL, PUNITIVE, INCIDENTAL OR
CONSEQUENTIAL LOSS, DAMAGE, COST OR EXPENSE OF ANY KIND WHATSOEVER RELATED TO THE
INFORMATION OR ITS USE, HOWEVER CAUSED, EVEN IF MICROCHIP HAS BEEN ADVISED OF THE
POSSIBILITY OR THE DAMAGES ARE FORESEEABLE. TO THE FULLEST EXTENT ALLOWED BY LAW,
MICROCHIP'S TOTAL LIABILITY ON ALL CLAIMS IN ANY WAY RELATED TO THE INFORMATION OR ITS USE
WILL NOT EXCEED THE AMOUNT OF FEES, IF ANY, THAT YOU HAVE PAID DIRECTLY TO MICROCHIP FOR
THE INFORMATION. Use of Microchip devices in life support and/or safety applications is entirely at the buyer’s risk,
and the buyer agrees to defend, indemnify and hold harmless Microchip from any and all damages, claims, suits, or
expenses resulting from such use. No licenses are conveyed, implicitly or otherwise, under any Microchip intellectual
property rights unless otherwise stated.
Trademarks
The Microchip name and logo, the Microchip logo, Adaptec, AnyRate, AVR, AVR logo, AVR Freaks, BesTime,
BitCloud, chipKIT, chipKIT logo, CryptoMemory, CryptoRF, dsPIC, FlashFlex, flexPWR, HELDO, IGLOO, JukeBlox,
KeeLoq, Kleer, LANCheck, LinkMD, maXStylus, maXTouch, MediaLB, megaAVR, Microsemi, Microsemi logo,
MOST, MOST logo, MPLAB, OptoLyzer, PackeTime, PIC, picoPower, PICSTART, PIC32 logo, PolarFire, Prochip
Designer, QTouch, SAM-BA, SenGenuity, SpyNIC, SST, SST Logo, SuperFlash, Symmetricom, SyncServer,
Tachyon, TimeSource, tinyAVR, UNI/O, Vectron, and XMEGA are registered trademarks of Microchip Technology
Incorporated in the U.S.A. and other countries.
AgileSwitch, APT, ClockWorks, The Embedded Control Solutions Company, EtherSynch, FlashTec, Hyper Speed
Control, HyperLight Load, IntelliMOS, Libero, motorBench, mTouch, Powermite 3, Precision Edge, ProASIC,
ProASIC Plus, ProASIC Plus logo, Quiet-Wire, SmartFusion, SyncWorld, Temux, TimeCesium, TimeHub, TimePictra,
TimeProvider, WinPath, and ZL are registered trademarks of Microchip Technology Incorporated in the U.S.A.
Adjacent Key Suppression, AKS, Analog-for-the-Digital Age, Any Capacitor, AnyIn, AnyOut, Augmented Switching,
BlueSky, BodyCom, CodeGuard, CryptoAuthentication, CryptoAutomotive, CryptoCompanion, CryptoController,
dsPICDEM, dsPICDEM.net, Dynamic Average Matching, DAM, ECAN, Espresso T1S, EtherGREEN, IdealBridge,
In-Circuit Serial Programming, ICSP, INICnet, Intelligent Paralleling, Inter-Chip Connectivity, JitterBlocker, maxCrypto,
maxView, memBrain, Mindi, MiWi, MPASM, MPF, MPLAB Certified logo, MPLIB, MPLINK, MultiTRAK, NetDetach,
Omniscient Code Generation, PICDEM, PICDEM.net, PICkit, PICtail, PowerSmart, PureSilicon, QMatrix, REAL ICE,
Ripple Blocker, RTAX, RTG4, SAM-ICE, Serial Quad I/O, simpleMAP, SimpliPHY, SmartBuffer, SMART-I.S., storClad,
SQI, SuperSwitcher, SuperSwitcher II, Switchtec, SynchroPHY, Total Endurance, TSHARC, USBCheck, VariSense,
VectorBlox, VeriPHY, ViewSpan, WiperLock, XpressConnect, and ZENA are trademarks of Microchip Technology
Incorporated in the U.S.A. and other countries.
SQTP is a service mark of Microchip Technology Incorporated in the U.S.A.
The Adaptec logo, Frequency on Demand, Silicon Storage Technology, and Symmcom are registered trademarks of
Microchip Technology Inc. in other countries.
GestIC is a registered trademark of Microchip Technology Germany II GmbH & Co. KG, a subsidiary of Microchip
Technology Inc., in other countries.
All other trademarks mentioned herein are property of their respective companies.
© 2022, Microchip Technology Incorporated, Printed in the U.S.A., All Rights Reserved.
ISBN: 978-1-5224-9642-7
PD-9601-zzGC/AC
© 2022 Microchip Technology Inc.
and its subsidiaries
User Guide DS50003257A-page 12

AMERICAS ASIA/PACIFIC ASIA/PACIFIC EUROPE
Corporate Office
2355 West Chandler Blvd.
Chandler, AZ 85224-6199
Tel: 480-792-7200
Fax: 480-792-7277
Technical Support:
www.microchip.com/support
Web Address:
www.microchip.com
Atlanta
Duluth, GA
Tel: 678-957-9614
Fax: 678-957-1455
Austin, TX
Tel: 512-257-3370
Boston
Westborough, MA
Tel: 774-760-0087
Fax: 774-760-0088
Chicago
Itasca, IL
Tel: 630-285-0071
Fax: 630-285-0075
Dallas
Addison, TX
Tel: 972-818-7423
Fax: 972-818-2924
Detroit
Novi, MI
Tel: 248-848-4000
Houston, TX
Tel: 281-894-5983
Indianapolis
Noblesville, IN
Tel: 317-773-8323
Fax: 317-773-5453
Tel: 317-536-2380
Los Angeles
Mission Viejo, CA
Tel: 949-462-9523
Fax: 949-462-9608
Tel: 951-273-7800
Raleigh, NC
Tel: 919-844-7510
New York, NY
Tel: 631-435-6000
San Jose, CA
Tel: 408-735-9110
Tel: 408-436-4270
Canada - Toronto
Tel: 905-695-1980
Fax: 905-695-2078
Australia - Sydney
Tel: 61-2-9868-6733
China - Beijing
Tel: 86-10-8569-7000
China - Chengdu
Tel: 86-28-8665-5511
China - Chongqing
Tel: 86-23-8980-9588
China - Dongguan
Tel: 86-769-8702-9880
China - Guangzhou
Tel: 86-20-8755-8029
China - Hangzhou
Tel: 86-571-8792-8115
China - Hong Kong SAR
Tel: 852-2943-5100
China - Nanjing
Tel: 86-25-8473-2460
China - Qingdao
Tel: 86-532-8502-7355
China - Shanghai
Tel: 86-21-3326-8000
China - Shenyang
Tel: 86-24-2334-2829
China - Shenzhen
Tel: 86-755-8864-2200
China - Suzhou
Tel: 86-186-6233-1526
China - Wuhan
Tel: 86-27-5980-5300
China - Xian
Tel: 86-29-8833-7252
China - Xiamen
Tel: 86-592-2388138
China - Zhuhai
Tel: 86-756-3210040
India - Bangalore
Tel: 91-80-3090-4444
India - New Delhi
Tel: 91-11-4160-8631
India - Pune
Tel: 91-20-4121-0141
Japan - Osaka
Tel: 81-6-6152-7160
Japan - Tokyo
Tel: 81-3-6880- 3770
Korea - Daegu
Tel: 82-53-744-4301
Korea - Seoul
Tel: 82-2-554-7200
Malaysia - Kuala Lumpur
Tel: 60-3-7651-7906
Malaysia - Penang
Tel: 60-4-227-8870
Philippines - Manila
Tel: 63-2-634-9065
Singapore
Tel: 65-6334-8870
Taiwan - Hsin Chu
Tel: 886-3-577-8366
Taiwan - Kaohsiung
Tel: 886-7-213-7830
Taiwan - Taipei
Tel: 886-2-2508-8600
Thailand - Bangkok
Tel: 66-2-694-1351
Vietnam - Ho Chi Minh
Tel: 84-28-5448-2100
Austria - Wels
Tel: 43-7242-2244-39
Fax: 43-7242-2244-393
Denmark - Copenhagen
Tel: 45-4485-5910
Fax: 45-4485-2829
Finland - Espoo
Tel: 358-9-4520-820
France - Paris
Tel: 33-1-69-53-63-20
Fax: 33-1-69-30-90-79
Germany - Garching
Tel: 49-8931-9700
Germany - Haan
Tel: 49-2129-3766400
Germany - Heilbronn
Tel: 49-7131-72400
Germany - Karlsruhe
Tel: 49-721-625370
Germany - Munich
Tel: 49-89-627-144-0
Fax: 49-89-627-144-44
Germany - Rosenheim
Tel: 49-8031-354-560
Israel - Ra’anana
Tel: 972-9-744-7705
Italy - Milan
Tel: 39-0331-742611
Fax: 39-0331-466781
Italy - Padova
Tel: 39-049-7625286
Netherlands - Drunen
Tel: 31-416-690399
Fax: 31-416-690340
Norway - Trondheim
Tel: 47-72884388
Poland - Warsaw
Tel: 48-22-3325737
Romania - Bucharest
Tel: 40-21-407-87-50
Spain - Madrid
Tel: 34-91-708-08-90
Fax: 34-91-708-08-91
Sweden - Gothenberg
Tel: 46-31-704-60-40
Sweden - Stockholm
Tel: 46-8-5090-4654
UK - Wokingham
Tel: 44-118-921-5800
Fax: 44-118-921-5820
Worldwide Sales and Service
© 2022 Microchip Technology Inc.
and its subsidiaries
User Guide DS50003257A-page 14

PD-9601-zzGC/AC
Power over Ethernet Single-port Midspan User Guide
Einleitung
Anmerkung: This translated document is provided as a courtesy and is for reference only. For the most up-to-date
information, refer to the latest English version of the document (Document Number: DS50003257, Revison A).
Die Familie der PD-9601-zzGC Power over Ethernet (PoE) Midspans von Microchip umfasst die Modelle
PD‑9601‑10GC, PD-9601-5GC und PD-9601-25GC Modelle. In diesem Dokument werden diese drei Modelle als
PD‑9601‑zzGC bezeichnet.
Der PD-9601-zzGC ist ein PoE Single Port Midspan/Injector, der eine kompakte und kostengünstige
Stromversorgungslösung für WLAN-Zugangspunkte, Netzwerkkameras und andere IP-Terminal-Installationen. Der
PD‑9601-zzGC speist Strom über datenführenden Ethernet-Verkabelung ein. Der PD-9601-zzGC PoE-Midspan/
Injektor entspricht dem IEEE® 802.3bt-Standard und liefert 54 VDC an 4-paarige Adern (Alt A: 1, 2 (-) und 3, 6
(+)\Alt B: 4, 5 (+) und 7, 8 (-)) eines Standard-Ethernetkabels der Kategorie 5E und höher (für 2,5G) bzw. Kategorie
6 und höher (für 5G und 10G) ermöglicht die Lieferung von Daten und Strom an das IP-Terminal. Der PD-9601-zzGC
kann über einen universellen AC-Eingang mit bis zu 90W versorgt werden.
Eigenschaften
PoE-Midspans bieten folgende wichtige Eigenschaften:
• 1-Port-PoE-Ausgang
• Garantierte Leistung von 90W
• Kompakte Produktgröße
• Universeller AC-Eingang: 100 VAC bis 240 VAC
• Konform mit Standard: IEEE 802.3bt
• 10/5/2,5 Gbps Pass-Through-Datenraten
© 2022 Microchip Technology Inc.
and its subsidiaries
User Guide DS50003257A-page 1

Inhalt
Einleitung........................................................................................................................................................1
Eigenschaften......................................................................................................................................... 1
1. Normen und Sicherheitsrichtlinien.......................................................................................................... 3
1.1. Definition der Teilenummer...........................................................................................................3
1.2. Elektrische Kompatibilitäts-Zulassungen......................................................................................3
1.3. Sicherheitsstandard-Zulassungen................................................................................................3
1.4. GS-Kennzeichnung...................................................................................................................... 3
1.5. Sicherheitshinweise......................................................................................................................4
2. Information en Matière de Sécurité......................................................................................................... 5
2.1. Directives Générales....................................................................................................................5
2.2. Mises en Garde............................................................................................................................5
3. PoE-Midspan-Installation........................................................................................................................ 6
3.1. Anschließen von Ethernetkabeln..................................................................................................6
3.2. Anzeigen...................................................................................................................................... 6
4. Fehlersuche............................................................................................................................................ 8
4.1. Vorläufige Schritte........................................................................................................................ 8
4.2. Schritte zur Fehlersuche.............................................................................................................. 8
5. Technische Daten..................................................................................................................................10
5.1. Physische Spezifikationen..........................................................................................................10
5.2. Umgebungsdaten.......................................................................................................................10
5.3. Elektrische Daten....................................................................................................................... 10
6. Kontaktaufnahme mit dem technischen Support...................................................................................11
7. Überarbeitungsübersicht....................................................................................................................... 12
The Microchip Website.................................................................................................................................13
Product Change Notification Service............................................................................................................13
Customer Support........................................................................................................................................ 13
Microchip Devices Code Protection Feature................................................................................................13
Legal Notice................................................................................................................................................. 13
Trademarks.................................................................................................................................................. 14
Quality Management System....................................................................................................................... 15
Worldwide Sales and Service.......................................................................................................................16
PD-9601-zzGC/AC
© 2022 Microchip Technology Inc.
and its subsidiaries
User Guide DS50003257A-page 2

1. Normen und Sicherheitsrichtlinien
In den folgenden Abschnitten werden die Normen und Sicherheitsrichtlinien für das Produkt aufgeführt.
1.1 Definition der Teilenummer
PD-9601-zzGC/AC: 4 Leitungspaare AC-Eingangsfamilie.
Tabelle 1-1. Definition der Teilenummer
Symbol Beschreibung
zzGC Steht für die Bandbreite (zz—10, 5 oder 2,5 Gbps).
AC Der Midspan hat einen AC-Eingang.
1.2 Elektrische Kompatibilitäts-Zulassungen
Die Microchip PD-9601-zzGC-Serie entspricht den folgenden Normen:
• FCC Teil 15: Klasse B
• EN 55032: Klasse B
• Kanadische ICES-003
• EN55035
• VCCI
1.3 Sicherheitsstandard-Zulassungen
Microchip erfüllt die folgenden Sicherheitsstandards. Wenden Sie sich an Microchip, um eine vollständige Liste der
Sicherheitszertifizierungen zu erhalten.
• UL/IEC/EN 62368-1
• GS-Übereinstimmung
1.4 GS-Kennzeichnung
Das GS-Zeichen auf diesem Produkt bedeutet, dass das Produkt dem deutschen Produktsicherheitsgesetz
entspricht.
PD-9601-zzGC/AC
Normen und Sicherheitsrichtlinien
© 2022 Microchip Technology Inc.
and its subsidiaries
User Guide DS50003257A-page 3

1.5 Sicherheitshinweise
Lesen Sie die Sicherheitshinweise, bevor Sie das PoE-Midspan-Gerät verwenden.
1.5.1 Allgemeine Richtlinien
Lesen Sie die folgenden Sicherheitsinformationen, bevor Sie Installations-, Demontage- oder Wartungsarbeiten am
PoE-Midspan durchführen. Die Warnhinweise enthalten Anweisungen, die für die Sicherheit von Personen und des
Produkts befolgt werden müssen.
1.5.2 Warnmeldungen
• Lesen Sie die Installationsanweisungen in 3. PoE-Midspan-Installation, bevor Sie den Midspan an die
Stromquelle anschließen.
• Lesen Sie die in 3. PoE-Midspan-Installation, bevor Sie die Midspan-zu-Midspan-Stromabsicherung
anschließen.
• Nur geschultes und qualifiziertes Personal darf diese Geräte installieren, ersetzen und warten.
• Dieses ITE-Gerät darf nur an PoE-Netzwerke (Power Supply over Ethernet) angeschlossen werden, ohne
Weiterleitung an andere Netzwerke.
• Das Netzkabel darf nicht an der Oberfläche des Gebäudes befestigt werden oder durch Wände, Decken, Böden
und ähnliche Öffnungen in der Gebäudestruktur führen.
• Es müssen Schritte unternommen werden, um physische Schäden am Netzkabel zu vermeiden, einschließlich
einer ordnungsgemäßen Verlegung.
• Zum Schutz gegen Kurzschluss und Überstrom muss dieses Produkt in einem Gebäude installiert werden.
Verwenden Sie nur eine Sicherung oder einen Schutzschalter mit nicht mehr als 15A für 120 VAC (USA) oder
10A für 230 VAC (international).
• Alle Verdrahtungen und Anschlüsse müssen der NFPA 70 (NEC) entsprechen.
• Führen Sie während eines Gewitters keine Arbeiten am System durch und schließen Sie keine Kabel an oder
trennen Sie sie ab.
• Eine falsche Spannung kann das Gerät beschädigen und eine Brandgefahr darstellen. Wenn die auf dem Etikett
angegebene Spannung nicht mit der Spannung der Steckdose übereinstimmt, darf der Midspan nicht an diese
Steckdose angeschlossen werden.
• Stellen Sie bei in einem Regal montierten Gerät sicher, dass die Oberfläche stabil und stark genug ist, um das
Gerät zu tragen. Stapeln Sie nicht mehr als vier Midspan-Geräte übereinander.
• Beachten Sie bei der Entsorgung dieses Produkts alle örtlichen Gesetze und Vorschriften.
• Die Daten- sowie Daten- und Stromausgangsports (Ausgangsports für Data sowie Data und Power) des
Midspan sind geschirmte RJ-45-Datenbuchsen. Sie können nicht als Plain Old Telephone Service (POTS)-
Buchsen verwendet werden. Schließen Sie nur RJ-45-Datenstecker an diese Buchsen an.
• Die zugehörige Ethernet-Verkabelung muss sich auf das Innere des Gebäudes beschränken.
PD-9601-zzGC/AC
Normen und Sicherheitsrichtlinien
© 2022 Microchip Technology Inc.
and its subsidiaries
User Guide DS50003257A-page 4

2. Information en Matière de Sécurité
Lire les informations suivantes en matière de sécurité avant d'utiliser d'activer l'alimentation sur votre appareil
Ethernet Midspan.
2.1 Directives Générales
Lire les informations suivantes en matière de sécurité avant d'installer ou enlever quoi que ce soit, ou procéder à
l'entretien de l'alimentation de votre appareil Ethernet Midspan. Les mises en garde contiennent des instructions qui
doivent être suivies pour la sécurité des personnes et du produit. Suivre les instructions soigneusement.
2.2 Mises en Garde
• Lire les instructions d'installation dans la cette 3. PoE-Midspan-Installation avant de connecter le Midspan à une
source d'alimentation.
• Lire les instructions d'installation dans la cette 3. PoE-Midspan-Installation avant de connecter le Midspan à une
source de sauvegarde Midspan.
• Seul du personnel formé et qualifié doit être autorisé à installer, remplacer et entretenir cet équipement.
• Cet ITE appareil doit être branché à des réseaux PoE (alimentation électrique par Ethernet) seulement, et ce,
sans routage vers d'autres réseaux.
• Le cordon d'alimentation ne doit pas être fixé à la surface du bâtiment ni traverser les murs, les plafonds, les
planchers et les ouvertures similaires de la structure du bâtiment.
• Des mesures doivent être prises pour éviter tout dommage physique au cordon d'alimentation, y compris un
acheminement approprié.
• Ce produit dépend de l'installation électrique de l'immeuble pour une protection contre les courts-circuits
(surcharges de courant). Utiliser seulement un fusible ou un disjoncteur dont la puissance ne dépasse pas
15A pour 120 VAC (É.-U.), ou 10A pour 230 VAC (international).
• Tout le câblage et les connexions doivent être conformes à la norme NFPA 70 (NEC).
• Ne pas exécuter de travaux sur le système, connecter ou déconnecter des câbles pendant les orages.
• Une disparité de voltage peut endommager l'équipement et constituer un risque d'incendie. Si le voltage indiqué
sur l'étiquette est différent du voltage de la source d'alimentation, ne pas connecter le Midspan à cette prise.
• Pour un équipement monté sur une tablette, vérifier que la surface est stable et suffisamment solide pour le
supporter. Ne jamais empiler plus de quatre unités Midspan.
• Pour disposer/jeter ce produit, suivre les lois et règlements locaux.
• Les ports Data et Data et Power du PoE Midspan sont des prises de données blindées RJ45. Elles ne peuvent
pas être utilisées comme prises de service téléphonique traditionnel. Connecter seulement des connecteurs de
données RJ45 à ces prises. Le câblage Ethernet connexe doit être limité à l'intérieur de l'immeuble.
• Le câblage Ethernet associé doit être limité à l'intérieur du bâtiment.
PD-9601-zzGC/AC
Information en Matière de Sécurité
© 2022 Microchip Technology Inc.
and its subsidiaries
User Guide DS50003257A-page 5

3. PoE-Midspan-Installation
Befolgen Sie die Installationsschritte sorgfältig:
1. Schließen Sie den PD-9601-zzGC an eine AC-Netzsteckdose an (100 VAC bis 240 VAC).
2. Verbinden Sie die Data-In-Buchse (Eingang) mit dem Patchpanel des Remote-Ethernetnetzwerk-Switches.
3. Verbinden Sie die Power-Out-Buchse (Ausgang) mit dem Endgerät.
Abbildung 3-1. Installieren des PD-9601-zzGC
Terminal Ethernet
Port
Output
Port
Input
Main LED
Indication
Terminal Ethernet
Port
Output
Port
Input
Main LED
Indication
3.1 Anschließen von Ethernetkabeln
Die Ports des PD-9601-zzGC Midspan sind als Pass-Through-Ports für Leiter mit RJ45-Anschlüssen konfiguriert.
Verwenden Sie zum Anschließen Kabel der Kategorie 6A. Siehe Abbildung 3-1.
1. Schließen Sie das Ethernet 10/5/2,5G Base-T-Eingangskabel (Ethernet) an die RJ45-Buchse am PD-9601-
zzGC an.
2. Schließen Sie das 10/5/2,5G Base-T, Plus 54 VDC -Ausgangskabel (Endgerät) an die RJ45-Buchse an, wobei
die DC-Spannung auf den Adernpaaren folgendermaßen ist, (Alt A: 1, 2 (-) und 3, 6 (+)\Alt B: 4, 5 (+) und 7, 8
(-)).
3.2 Anzeigen
In der folgenden Tabelle finden Sie eine Übersicht der Anzeigen, die den Status des PoE-Midspan und seiner Ports
angeben.
Tabelle 3-1. Port-Anzeige-LED
Port-LED-Farbe Port-Lastbedingungen
Orange ON (EIN) Stromeingang ist aktiv
Orange blinkend Fehler am Stromeingang
Blau ON (EIN) Port ON (EIN)—PoE über 2P
Blau blinkend Portfehler
Grün ON (EIN) Port ON (EIN)—PoE über 4P
PD-9601-zzGC/AC
PoE-Midspan-Installation
© 2022 Microchip Technology Inc.
and its subsidiaries
User Guide DS50003257A-page 6
Table of contents
Languages:
Popular Laboratory Equipment manuals by other brands

WILKINS
WILKINS ZW209 Installation, Troubleshooting, Maintenance Instructions

Pentair
Pentair BIOSHIELD Installation and user guide

Tuttnauer
Tuttnauer 2540 EHS Operation & maintenance manual

Vernier
Vernier Go Direct Sound user manual

INTEGRA Biosciences
INTEGRA Biosciences PIPETBOY comfort operating instructions

Agilent Technologies
Agilent Technologies 7890 Series Troubleshooting