Midas 926 Gateway Light User manual

Midas-926 Gateway Light
Model:
Midas-926.GM915
FCC ID: 2A293M926GM915
IC: 27881-M926GM915
Helium Light Hotspot
USER'S MANUAL

ATTENTION
Contact us atTwitter. (Scan this QR code)
Official Discord channel:
https://discord.gg/yFSTWJrA6R
PLEASEDONOTRETURNTHISPRODUCTUNTILYOU
CONTACTED US.
IMPORTANT. Contact customer service if you have
any questions regarding assembly or proper
operation of the device.
Call us at: (+86) 21-52685889
Time: 8:00 a.m. - 5:00 p.m. (GMT+8) Daily

SAFETY INSTRUCTIONS
1. To ensure that you can use this LoRaWan gateway
safely, reliably and stablely, please read the important
notices below and all the operation instructions prior
to usage.
. 2.Please join Midas discord channel and follow Midas official
twitter and you can get help from professional technical support
and advices from the community. It is also useful to read all
QnAs on Midas official website.
Important Notes
a) This product can only be used indoors.
b) Keep away from water and avoid moisture.
c) Use offical DC-DC adaptor. The input DC voltage can not be higher
than 5V.
d) Overheat may cause malfunction of this product.
e) For better coverage, the antenna needs to be close to the window
and facing open space.

DESIGN ILLUSTRATION
r

NO. Name
1 System indication LED
2 LoRa LED
3 WLAN LED
4 Ethernet LED
5 Antenna port
6 Reset switch
7 Ethernet port
8 DC power port
Product dimension: 155mm (L) * 155mm (W) * 41mm (H )
Lora Antenna:
Model name glue stick antenna
Frequency Range (MHz) 902-928MHZ
V.S.W.R 2.0
Gain (dBi) 3
The antenna size 125mm
Power Capacity (w) 10

ASSEMBLY INSTRUCTIONS
Please confirm whether the parts are complete before installation.
Parts list NO. Name Quantity
1 Midas-926 Gateway Light Device 1
2 Antenna 1
3 5V DC-DC adapter 1
4 Pin 1
Plug in the provided 5V DC-DC power adapter into an outlet and screw
in the provided antenna on the back of the Midas-926 Gateway Light.
Connect the device using Ethernet cable with your router and make
sure the internet access is avaible.
Wait for the device starting and the LoRaWan function is fully
operational when the LoRa indicator light is steady green.
Note: there is no need to set up the device. All the functions will be
automatically started after power on.
DEBUGGING
The debugging of Midas-926 Gateway Light should pay attention to the
following aspects:
1.When powering on, the system LED should blink meaning the system
is booting. During operation, this system LED should blink from time to
time but less frequently. If system LED doesn t light up at all, the OS
may be not working.
2.During operation, the LoRa LED should be on, or there must be some
software failure in the device.

PRODUCT FEATURES
1. This is a LoRaWan Gateway that integrates all the Helium Light
Hotspot functions.
2. Frequency band: US915.
3. Transmission mode: semi-duplex.
4. Semtech SX1302 based LoRa concentrator supporting CN/US/EU
bands
5. MIPS processor @ 580MHz
6. 128MB DDR2 RAM
7. 16MB Flash
8. ATECC608 chip for swarm key
9. WiFi(2.4GHz) IEEE 802.11b/g/n
10. Status indication LEDs
11. Voltage 5V
12. Automatic software update

MIDAS STARTER APP INSTRUCTION
This Midas-926 Gateway Light can work with Midas Starter App so you
can easily use it to join Helium network. To get started, make sure you
have the Midas Starter App downloaded to your mobile device and
your smart phone meets the requirement, for iOS (iOS version 13 and
above) and Android (OS 8 and above).
Once you have the app downloaded and a Helium wallet created,
unbox the Midas-926 Gateway Light and get ready!
1. In the Midas Starter App, go to Hotspots and press +.
2. Select the Midas-926 Gateway Light when asked what you'd like to
add to the network.
3. Make sure you select a good place for the device so it has a clear
view of the sky! Obstructions and hidden Hotspots drastically
impede earnings and coverage.
4. Plug in the Midas-926 Gateway Light to power it on. The system
light will flash when the system is started.
5. Continue the onboarding flow. The cost to add a Midas-926
Gateway Light is free. If this is not the case, please contact
6. Confirm Hotspot Location. The cost to set a location for a Midas-
926 Gateway Light is free for two locations. If you are not ready to
set a location, you can do so later by pressing Skip for now. If you
do not see fee-free location, please contact
7. And that's it! The Midas-926 Gateway Light is now being added to
the Network. Because this is a blockchain, your Hotspot may take
a few minutes to appear in the app.

FCC WARNING
Any Changes or modifications not expressly approved by the party
responsible for compliance could void the user's authority to
operate the equipment.
Note: This equipment has been tested and found to comply with
the limits for a Class B digital device, pursuant to part 15 of the
FCC Rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including
interference that may cause undesired operation.
These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment
generates uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is
no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help.
This equipment complies with FCC radiation exposure limits set
forth for an uncontrolled environment. This equipment should be
installed and operated with minimum distance 20cm between the
radiator & your body.

IC WARNING
This device complies with Industry Canada licence-exempt RSS
standard(s).
Operation is subject to the following two conditions: (1) This device
may not cause interference, and (2) This device must accept any
interference, including interference that may cause undesired
operation of the device.
Le présentappareilestconforme aux CNR d'Industrie Canada
applicables aux appareils radio exempts de licence.
L'exploitationestautorisée aux deux conditions suivantes:
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareildoit accepter tout
brouillageradioélectriquesubi, mêmesi le brouillageest susceptible
d'encompromettre le fonctionnement.
“This equipment complies with IC RF radiation exposure limits set
forth for an uncontrolled environment.
This equipment should be installed and operated with a minimum
distance of 20 centimeters between the radiator and your body.”
«ce matériel est conforme aux limites d'exposition aux
rayonnements rf de ic énoncés dans un autre environnement.
ce matériel doit être installéet exploitéàune distance minimale de
20 cm entre le radiateur et v
This manual suits for next models
1
Table of contents
Other Midas Gateway manuals
Popular Gateway manuals by other brands

Moxa Technologies
Moxa Technologies MGate MB3000 Modbus user manual

RTA
RTA 460ESTCP-NNA1 Product user guide

RTA
RTA 460PSBM-N2EW Product user guide

La Crosse Technology
La Crosse Technology MOBILE TX71U-IT quick start guide

Amit
Amit IOG761-0TV21 user manual

Capetti Elettronica
Capetti Elettronica Wine Cap MWDG-ETH Configuration manual