75730 Instructions for Kit #75729 = West Temperature Controller • Rev. H • 09-27-21 Page 1 of 8
PN 75729 = KIT, WEST TEMPERATURE CONTROLLER
PURPOSE
This kit is being installed to replace previous Honeywell, West, and analog temperature controllers. Analog
temperature controllers include P/N 28071-0012, 28071-0018, and 34983.
For use in the following ovens: PS520, PS528, PS629,PS536, PS540, PS555, PS570, PS360EWB, PS624,
PS628, PS200, PS200VL, PS360S, PS360WB, PS314
For PS640VE2, PS740VE2, and PS840VE2, use instructions on page 3.
ITEM P/N DESCRIPTION
1 71280 TEMPERATURE CONTROLLER
2 76579 TERMINAL BLOCK, PLUG TYPE, FEMALE
3 75732 PIGTAIL ASSEMBLY
4 75730 INSTRUCTION SHEET (not shown)
5 N/A MISCELLANEOUS EXTRA TERMINALS
Installation Assistance
HIGHLY RECOMMENDED: Use the QR codes below to view Installation and Programming videos
before beginning!
INSTALLATION PROGRAMMING
https://middmarshall.com/install-westcontroller.php https://middmarshall.com/program-westcontroller.php
TOOLS REQUIRED
Wire labels, screwdrivers, wire cutter/stripper, cable ties, electrical tape. For West controller only: spudger tool.
WARNING: Disconnect the oven power before proceeding to remove old or install new wires.

75730 Instructions for Kit #75729 = West Temperature Controller • Rev. H • 09-27-21 Page 2 of 8
CONTROLLER REPLACEMENT PROCEDURES
Instructions to replace Honeywell controller using pigtail (ALL OVENS EXCEPT PS640VE2, PS740VE2,
PS745, and PS840VE2)
1. Open the control panel of the oven with the old controller.
2. Label all wires going into the Honeywell controller with associated Honeywell
terminal positions.
3. Disconnect the orange or green female terminal block from the pigtail.
4. One by one, route the labeled wires from the
Honeywell control to the terminal block poles based
on the chart to the right. Make sure ALL wires in the
Honeywell terminal are transferred to their respective
terminal block position. Some terminal block positions
may be empty, and some may have multiple wires.
NOTE: JUMPERS: Discard the jumper between
Honeywell positons L1 and 10, if applicable.
OTHER JUMPERS: Any other jumper will be rerouted
to the appropriate poles on the terminal block, jumping
two positions on the terminal block.
Honeywell
Labels
Terminal
Block Pole
10/L1
1
9
2
L2
3
11
4
12
5
16
6
15
7
8
8
7
9
5
10
4
11
NOTE: L1/10: All wires connected to L1 and 10 will be routed into the same terminal pole (#1).
5. PS555E ONLY: Remove the wire connected to position 9 on the Honeywell controller. Reroute the wire
connected to position 10 to Terminal Block Pole 2.
6. Reroute ground wires into nearby chassis ground studs.
7. Remove the Honeywell controller by unscrewing the two retaining brackets
and pulling the controller out of the front of the panel.
8. Remove the plastic retaining bracket from the back of the West controller.
Ensure that the rubber gasket remains installed in the inside bevel of the
controller.
9. If pigtail is not assembled to the West controller, assemble the pigtail to the
controller by matching the wire numbers to the position on the West controller.
To facilitate insertion into the control panel, do not connect wires 22 and 24.
10. Insert the pigtail and controller through the square hole in the control panel. If
wires 22 and 24 have been connected, disconnect to allow the controller to fit
through the square hole.
11. Assemble the plastic bracket to the back of the controller, with retaining feet
pointed away from the control panel and tighten as much as possible by hand.
12. Connect wires 22 and 24 to the matching terminals on the West controller.
13. Plug the male and female terminal blocks together.
14. Tidy wires with cable ties. Use electrical tape as needed to prevent shorts.

75730 Instructions for Kit #75729 = West Temperature Controller • Rev. H • 09-27-21 Page 3 of 8
Instructions to replace Honeywell controller on ovens PS640VE2, PS740VE2, PS745, and PS840VE2
1. Remove the pigtail from the back of the West controller, including the jumper. Discard the
pigtail.
2. Open the control panel of the oven with the old controller.
3. Ensure wire numbers match wiring diagram and chart below.
4. Remove all wires from the Honeywell controller.
5. Remove the Honeywell controller by unscrewing the two retaining brackets and pulling
the controller out of the front of the panel.
6. Remove the plastic retaining bracket from the back of the West controller. Ensure that the
rubber gasket remains installed in the inside bevel of the controller.
7. Insert the controller through the hole in the control panel.
8. Assemble the plastic bracket to the back of the controller, with retaining feet pointed away
from the control panel and tighten as much as possible by hand.
9. Connect wires to the controller based on the chart below. Reroute ground wires to nearby
chassis grounds.
Wire Number
Controller Terminal
Thermocouple WHITE
2
Thermocouple RED
3
16
14
44
13
84
12
83
11
86 OR 25
7
87
6
ANY GROUND WIRE
CHASSIS GROUND
Instructions to replace Honeywell controller without pigtail
If there is an issue using the pigtail or one is not available, the old wires on the Honeywell controller may be
attached directly to the West controller.
1. Open the control panel of the oven with the old controller.
2. Label all wires going into the Honeywell controller with associated Honeywell terminal positions.
3. Remove all wires from the back of the Honeywell controller. Set aside any jumpers.
4. Remove the Honeywell controller by unscrewing the two retaining brackets and pulling the controller out of the
front of the panel.
5. Remove the plastic retaining bracket from the back of the West controller. Ensure that the rubber gasket
remains installed in the inside bevel of the controller.
6. Insert the controller through the hole in the control panel.
7. Assemble the plastic bracket to the back of the controller, with retaining feet pointed away from the control
panel and tighten as much as possible by hand.
8. Attach wires to the West controller based on the chart below. Any jumpers from the Honeywell controller must
be transferred to the West controller in the appropriate position.
Honeywell Terminal
West Terminal
L1
13
L2
14
4
9
5
8
7
3
8
2
9
12
10
11
11
20
12
21
15
24
16
22

75730 Instructions for Kit #75729 = West Temperature Controller • Rev. H • 09-27-21 Page 4 of 8
Instructions to replace broken West controller
1. Pull front panel off the old West controller. No fastener is used, instead the face is press-fit into the body. Use a
spudger tool to assist with face removal.
2. Replace with front panel from the new West controller.
Instructions to replace old analog controller
1. To replace Analog Controllers, follow the steps under “Instructions to replace Honeywell controller using pigtail”
above. In step 4, connect the following controller labels to the terminal block poles.
P/N 28071-0012 and 28071-0018
P/N 34983
Controller Labels
Terminal Block Poles
Controller Labels
Terminal Block Poles
14/L1
1
L1
1
13
2
L2
3
L2
3
TC+
8
15
4
TC-
9
16
5
COM
10
1
8
NO
11
2
9
5
10
6
11

75730 Instructions for Kit #75729 = West Temperature Controller • Rev. H • 09-27-21 Page 5 of 8
WEST CONTROLLER PROGRAMMING PROCEDURES
NOTE: The instrument will always return automatically to Operator mode if there is no key activity for 2
minutes.
Initial start-up
1. Turn the blower switch to start the oven without heat.
Star Key Scroll Key
2. If “GoTo ConF” displays, press the Scroll key to enter the Unlock Screen.
3. Press the up key to enter the unlock code (“20”), then press the Scroll key to
proceed.
4. Press the Scroll key 20 times to scroll through the list of parameters.
5. Hold down the Star key for 3 seconds to return to Operator mode.
For all Electric ovens with Modulating Heat (Pigtail Positions 6 and 7
used), except PS520E.
a. Continue to Manually Loading PID Values.
For all Gas ovens with Modulating Heat (Pigtail Positions 6 and 7 used)
a. No further setup is required. Continue to Operating Instructions.
For all ovens with On/Off or Solenoid Heat (Pigtail Positions 10 and 11
used):
(Oven Models include PS570S, PS360, PS360WB, PS200, etc.)
a. Hold down the Scroll key and press the up key to enter Select mode.
b. Press the up key until “SEtP” appears in the upper display.
c. Press the Scroll key to enter the Unlock Screen.
d. Press the up key to enter the unlock code (“10”), then press the Scroll key
to proceed.
e. Press the Scroll key until parameter Pb_P is displayed.
f. Use the down arrow key to set Pb_P to “0.0”.
g. Hold the Star key for 3 seconds to return to Operator mode. Continue to
Operating Instructions.
For PS520E ovens only:
a. Hold down the Scroll key and press the up
key to enter Select mode.
b. Press the up key until “ConF” appears in
the upper display.
c. Press the scroll key to enter the Unlock
Screen.
d. Press the up key to enter the unlock code
(“20”) then press the Scroll key to proceed.
e. Press the Scroll key until parameter “tYP 2”
is displayed.
f. Use the up key to change the value of
“tYP 2” to “0_10” (other ovens use 4_20).
g. Press the Star key to confirm.
h. Hold the Star key for 3 seconds to return to
Operator mode. Continue to Manually
Loading PID Values.
Mode
Upper
Display
Lower
Display
Description
Default
Unlock
Codes
Operator
OPtr
SLCt
Normal operation
None
Set Up
SEtP
SLCt
Tailor settings to
the application
10
Configuration
ConF
SLCt
Configure the
instrument for use
20
Product Info
inFo
SLCt
Check
manufacturing
information
None
Auto-Tuning
Atun
SLCt
Invoke Pre-Tune
or Self-Tune
0
Note: In Configuration Mode, modified parameters
must be confirmed by pressing the “star”key after
making a change. The parameter will blink until the
change is confirmed.

75730 Instructions for Kit #75729 = West Temperature Controller • Rev. H • 09-27-21 Page 6 of 8
Manually Loading PID Values
For electric ovens, PID values need to be manually loaded. The control comes pre-loaded with gas oven PID values.
1. Hold the Scroll key and press the up key to enter the Select (SLCt) mode.
2. Use the up key until “SEtP” appears in the upper display.
3. Press the up key to enter the unlock code (“10”), then press the Scroll key to proceed.
4. Press the Scroll key until parameter “Pb_P” is displayed. Use the up key until the number from the table below
is shown. Press the Scroll key to select.
5. Press the Scroll key to move to parameter “ArSt”, then use the up key until the number from the table below is
shown. Press the Scroll key to select.
6. Press the Scroll key to move to parameter “rAtE”, then use the up key until the number from the table below is
shown. Press the Scroll key to select.
7. Hold the Star key for 3 seconds to return to the operator screen. Continue to Operating Instructions.
Oven Type
PS540G
1.4
0.20
0.03
PS540E
1.7
0.53
0.13
Other Gas Ovens (default)
1.0
0.20
0.04
Other Electric Ovens
1.6
0.52
0.13
Solenoid Ovens (Pigtail positions
10 and 11 used)
0.0
N/A
N/A
Terminal Cross Reference Chart
Honeywell
Terminals
Terminal
Block Pole
West
Terminals
Connection
Purpose
L1
1
13
POWER
9
2
12
Output from Cool Down Relay (NO)
L2
3
14
NEUTRAL
11
4
20
Input to High Limit Relay (COMMON)
12
5
21
Output from High Limit Relay (NO)
16
6
22
PID or Variable Pulse Output
15
7
24
PID or Variable Pulse Output
8
8
2
TC (+) WHITE
7
9
3
TC(-) RED
5
10
8
Input to Temp Control Relay (COMMON)
4
11
9
Output to High Flame Solenoid or Heater Contactors (NO)
10
1
11
Input to Cool Down Relay (COMMON)

75730 Instructions for Kit #75729 = West Temperature Controller • Rev. H • 09-27-21 Page 7 of 8
Proper Installation Checklist
1. Set the set point at the correct operating temperature.
2. Turn on the heat switch. Ensure the oven comes up to temperature and stays at temperature.
NOTE: HEAT LIGHT: For modulating ovens, the heat light will stay on at any effort above 0%, and will only turn off
if the set point temperature is lowered below the current temperature. For solenoid ovens, the heat light will turn on
when the solenoid is open and off when the solenoid is closed.
3. Turn off the blower switch. Ensure that the oven blowers remain running until the oven has dropped below 200°F,
after which the oven will turn off.
4. After the oven has turned off, turn the blower switch back on again. Ensure that the oven operates normally.
Troubleshooting
Error Code or Situation
Description
Troubleshooting Steps
Upper Display: or
Temperature input is out of range.
Double check that the thermocouple
wires are in the correct positions in
the pigtail as well as on the
temperature controller (WHITE in
terminal 2 and RED in terminal 3).
Upper Display:
The controller does not detect
Thermocouples.
Double check that the thermocouple
wires are in the correct positions in
the pigtail as well as the temperature
controller. Ensure the terminal
blocks are properly plugged
together.
Upper Display:
There is an internal fault in the
controller.
Turn off the power for at least 10
seconds, then turn it back on. If error
does not clear, replace the defective
controller.
Solenoid Ovens: Solenoid is not
opening.
The Solenoid is not receiving power.
Check that parameter Pb_P is set to
0. Check that pigtail position 10 is
connected to Line voltage and
position 11 is connected to the
solenoid.
All ovens: A relay is not working
(cooldown relay, heat relay, high limit
relay)
The relay is not receiving power.
Check that any jumpers (except L1-
10) were transferred to the terminal
block.
NOTE: If GoTo ConF displays after power is cycled:
a. Turn the blower switch to start the oven without heat.
b. When “GoTo ConF” displays, press the Scroll key to enter the Unlock
Screen.
c. Press the up key to enter the unlock code (“20”), then press the Scroll key
to proceed.
d. Press the scroll key 20 times to scroll through the entire list of parameters.
e. Hold the Star key for 3 seconds to return to the Operator screen.
f. “GoTo ConF” should not return.

75730 Instructions for Kit #75729 = West Temperature Controller • Rev. H • 09-27-21 Page 8 of 8
OPERATING INSTRUCTIONS
NOTE: After 1 minute of no key activity, the controller will go to “Set Point Only” with the lower display blank.
OPERATION ADJUSTMENTS
Adjusting the Set Point
The set point appears in the upper
display and can only be adjusted when
the lower display is blank. Press the
Scroll key until you reach this “Set
Point Only” display. Use the Up and
Down keys to adjust the temperature.
Holding in the pressed key will adjust
at a faster rate.
Adjusting for °F/°C
Press the Up and Down keys together for 3 seconds.
The units will switch between Fahrenheit and Celsius.
PROGRAMMING ADJUSTMENTS
Locking and Unlocking Set Point
The Set Point can be locked so that it isn’t changed
during operation. Press the Star key for 3 seconds, then
use the Scroll key to choose Set Point Lock. Use the Up
and Down keys to turn the Set Point Lock on and off.
Press the Star key for 3 seconds to exit.