Mira flight SFE Pivot Enclosure User manual

CFI254H
Fitting Instructions
Pivot
Enclosure
with 762, 800, 900 door
(71 & 90)
SFES
SFE
For latest prices and delivery to your door visit MyTub Ltd - www.mytub.co.uk - [email protected] 0844 556 1818

2
CFI254H
Introduction
The following pages aim to provide comprehensive installation instructions, plus advice on
how to care and maintain your product.
We recommend that the unit is installed by a qualified Plumber or Engineer.
Please retain these instructions for future reference.
Safety Precautions
Caution: Care should be taken when drilling into walls and floors to avoid any hidden pipes or
wires.
We strongly recommend that all glass panels are moved by a minimum of two people and that
any protective packaging along the glass edges is kept in place for as long as possible to
prevent damage before installation.
Wear protective
footwear when
lifting panels
Wear safety
glasses when
drilling
Care & Maintenance
The unit should be wiped down immediately after each use.
Use a non abrasive cleaner with a pH value between 4 & 8,
applied with a soft cloth. A 50:50 solution of vinegar & water
can be used on lime scale deposits, rinsing off thoroughly
after use. Do not use alkalis such as caustic soda.
Under no circumstances should scourers or powerful detegents
be used as these can damage the metallic surface of the frame
and the surface of the tray or bath.
If fitted correctly the unit should not require any maintenance
other than cleaning. If problems do occur contact the Mira
Enclosures Technical Helpline Tel: 0844 571 5000
People not familiar with the fitting of Mira products may require the assistance
from another person at certain stages of the procedure. We have indicated these
points in the process with the Caution Symbol. Caution
Guarantee
For domestic installations, Mira Showers guarantee this shower enclosure against any defect in
materials or workmanship for a period of ten years from the date of purchase.
For non-domestic installations, Mira Showers guarantee this shower enclosure against any
defect in materials or workmanship for a period of one year from the date of purchase.
For Terms and Conditions refer to the page opposite.
Recommended Usage Domestic
Light Commercial
Heavy Commercial
Healthcare
For latest prices and delivery to your door visit MyTub Ltd - www.mytub.co.uk - [email protected] 0844 556 1818

Components
Before installation check that all components are correctly supplied.
If any parts are missing please ring the helpline. Tel: 0844 571 5000
Transit Clamps
Panel Wall Channel
IMPORTANT
Do not remove the panel wall channel or transit clamps
until the door has been fitted to the tray.
Side Panel
Cover Strip
Cover Strip
Door Wall Channel
Panel Magnetic
Sealing Strip
Door Magnetic
Sealing Strip
CFI254H 3
For latest prices and delivery to your door visit MyTub Ltd - www.mytub.co.uk - [email protected] 0844 556 1818

CFI254H 4
Top Caps
x6
Spacer
x2 (1 Not Required)
Glass Fixing Clamp
Glass Fixing Cover
x2
x2
?0844 571 5000
Plug
x4 (2 Not Required)
x4
Plug
x6
4mm Allen Key
3mm Allen Key
Glass
Moulding
x2
Splashguard
Fixing Bolt
x4
Door Handle
Assembly
For latest prices and delivery to your door visit MyTub Ltd - www.mytub.co.uk - [email protected] 0844 556 1818

x3
6mm
x3
±0mm
Wall channel
MUST be
vertical on
the front face.
x3
x3
11mm
11mm
STEP
1
STEP
2
Caution
Carefully lay the door on a soft horizontal surface.
Remove the tape from the transit clamps.
DOOR SIDE: Fit the door wall channel to the wall.
STEP
4
STEP
3
DOOR SIDE
The door must be installed with the pivot by the
wall, not the side panel.
±0mm
NOTE
Unit is reversible. RH fitting shown. LH fitting is a
mirror image of these instructions.
Carefully pull the door wall
channel from the wall jamb.
Unit Size Frame Adjustment
762mm
800mm
729mm to 758mm
769mm to 798mm
900mm 869mm to 898mm
Fit tray and then tile walls before fitting the unit.
IMPORTANT
Tray MUST be level in all
planes or the unit will not
install properly.
Mark wall 11mm in from
edge of tray.
CFI254H 5
For latest prices and delivery to your door visit MyTub Ltd - www.mytub.co.uk - [email protected] 0844 556 1818

x3
6mm
x3
±0mm
Wall channel
MUST be
vertical on
front face.
x3
x3
PANEL SIDE: Fit the panel wall channel to the wall.
22mm
Note:
Fixing block
must be on
the inside
edge of
the wall
channel.
CFI254H 6
Caution
STEP
5
STEP
6
PANEL SIDE
STEP
7
22mm
Carefully lift the door assembly into place. Unscrew the bolts top and
bottom and remove the panel
wall channel.
IMPORTANT
Leave the transit clamps in place
to support the door assembly.
STEP
8
The line on the wall channel
marks the maximum
amount of adjustment.
When fitted this line
MUST NOT be visible
outside the wall jamb.
Mark wall 22mm in
from edge of tray.
For latest prices and delivery to your door visit MyTub Ltd - www.mytub.co.uk - [email protected] 0844 556 1818

Have a person stand inside the enclosure.
Carefully lift the panel into place.
STEP
10
Caution
STEP
11
STEP
12
30mm Max
Caution
Carefully slide the panel into the wall channel.
Engage the mouldings but do not lock into
place at this moment.
Fix the panel to the door at top and bottom.
Note: The holes in the glass are larger than the
mounting blocks. Centre the glass on blocks
when fitting.
Note:
Assembly is
aided by
tilting the
panel and
moving the
fixing blocks
up or down
in the wall
channel.
Break one spacer in half.
3mm
6mm
Fit the two glass mouldings to the INSIDE of
the side panel.
Push the tabs ‘A’ against the edge of the glass
then push the pin into the hole in the glass ‘B’
until the moulding snaps into place.
A
AB
STEP
9
Place the 3mm section into
the base of the wall channel
(Use the 6mm section or omit
the spacer if the tray is not
perfectly level).
CFI254H 7
For latest prices and delivery to your door visit MyTub Ltd - www.mytub.co.uk - [email protected] 0844 556 1818

3mm
3mm
If the tray has been fitted level the gap under the
glass panel should be 3mm along its length and
the bottom track should be on the tray.
The position of the door can be adjusted by
loosening the fixing screws ‘A’ and undoing the
locks in the wall channels. The whole assembly
can be moved to the correct position.
Tighten the screws and wall
channel locks when adjustment
is complete.
Carefully pull the transit clamp away from the
track and door.
CFI254H 8
Locked position
STEP
13
STEP
15
STEP
14
STEP
16
Check that the door and panel are far enough into
the wall channels to lock securely (See Step 11).
Adjust if required.
Lock the panel into the wall channel by turning
the cam through 90o.
Unlocked Locked
On the door side turn the adjusters through
90oto lock the door assembly to the wall channel.
A
For latest prices and delivery to your door visit MyTub Ltd - www.mytub.co.uk - [email protected] 0844 556 1818

Fit splashguards to the underside of the door.
The splashguard lip should face inside the
enclosure.
762 = 470mm
800 = 510mm
(900 = 610mm Uncut)
For 762 & 800 enclosures, cut the splashguard
to the correct length.
STEP
17
Fit the cover strip to the wall jamb.
Note:
The cover strip may need cutting to the correct
length, but do not stretch when fitting.
Glass should touch strip
when door is closed. STEP
19
STEP
20
Fit the cover strip to the panel wall channel.
Start at the bottom and tap into place
with a block of wood or similar.
9
CFI254H
Fit the seals to the side of the door and the
side of the panel.
When the door is closed
the magnetic strips should
touch along their length.
The two magnetic strips should
attract each other when the door is
closed. If they repel each other
remove the strip from its fitting in
the panel seal, turn it through 180o
and then refit.
STEP
18
For latest prices and delivery to your door visit MyTub Ltd - www.mytub.co.uk - [email protected] 0844 556 1818

Fit the top caps.
Note:
If the glass is higher
than the wall channel,
trim away the
recessed section
of the top cap.
10
STEP
21
STEP
22
Slide the covers over the glass fixing clamps
top and bottom.
Lay a thin bead of sealant between wall channel
and wall on both sides.
STEP
23
STEP
24
CFI254H
Fit two of the larger plugs to blank off the holes
at the wall side of the top and bottom tracks.
Fit one of the smaller plugs to blank off each of the
holes on the panel side of the top and bottom tracks.
For latest prices and delivery to your door visit MyTub Ltd - www.mytub.co.uk - [email protected] 0844 556 1818

Lay a thin bead of sealant along the bottom of
track and fill the gap between the glass and
tray on the outside of the enclosure.
Fit the door handle.
24hrs
Do not use the enclosure for
at least 24 hours.
STEP
25
STEP
26
CFI254H 11
For latest prices and delivery to your door visit MyTub Ltd - www.mytub.co.uk - [email protected] 0844 556 1818

CFI254H 12
Spare Parts
For latest prices and delivery to your door visit MyTub Ltd - www.mytub.co.uk - [email protected] 0844 556 1818

Guarantee of Quality
Mira Showers guarantee your product against any defect in materials or workmanship,
provided that it is installed and maintained in accordance with the instructions given in
this guide. To validate the guarantee, please return your completed registration card
within 30 days of product installation. Within the guarantee period we will resolve defects,
free of charge, by repairing or replacing parts or modules as we may choose. To be free
of charge, service work must only be undertaken by Mira Showers or our approved
agents. Service under this guarantee does not affect the expiry date of the guarantee.
The guarantee on any exchanged parts or product ends when the normal product
guarantee period expires.
Not covered by this guarantee:
Damage or defects arising from incorrect installation, improper use or lack of
maintenance, including build-up of limescale. Damage or defects if the product is taken
apart, repaired or modified by any persons not authorised by Mira Showers or our
approved agents. This guarantee is in addition to your statutory and other legal rights.
What to do if something goes wrong
If when you first use your enclosure, it does not function correctly, first contact your
installer to check that installation is satisfactory and in accordance with the instructions
in this manual. We are on hand to offer you or your installer any advice you may need.
Should this not resolve the difficulty, simply contact our Customer Services Team who
will give every assistance and, if necessary, arrange for our service engineer to visit. If the
operation of your enclosure declines, please call our Customer Services Team to talk the
difficulty through, request a service under guarantee if applicable, or take advantage of
our comprehensive After-Sales service. As part of our quality and training programme
calls may be recorded or monitored. Our Customer Services Team is comprehensively
trained to provide every assistance you may need: help and advice, spare parts or a
service visit.
Spare Parts
We maintain an extensive stock of spares and aim to provide support throughout the
product’s expected life. Genuine Mira spares can be purchased direct from Customer
Services. Spare parts will normally be despatched within three to five working days.
Payment can be made using most major Credit or Debit cards at the time of ordering.
Should payment by cheque be preferred, a pro-forma invoice will be sent. All spares are
guaranteed for 12 months from the date of purchase.
Service / Repairs
Our Service Force is available to provide a quality service at a reasonable cost. You will
have the assurance of a Mira trained engineer/agent, genuine Mira spare parts and a 12
month guarantee on the repair. Payment should be made directly to the engineer via
cheque on the day, alternatively an invoice will be sent after the visit if you would prefer
to pay via credit or debit card.
To Contact Us
England, Scotland, Wales and Northern Ireland:
Mira Enclosures Technical Helpline
Telephone: 0844 571 5000 Mon to Fri 8:00 am - 5:30 pm
Sat 8.30 am - 3.30 pm
E-mail: [email protected]
Fax: 01242 282595
Post: Cromwell Road, Cheltenham, Gloucestershire, GL52 5EP
Mira is a registered trade mark of Kohler Mira Limited.
The company reserves the right to alter product specifications without notice.
www.mirashowers.co.uk
13
CFI254H
For latest prices and delivery to your door visit MyTub Ltd - www.mytub.co.uk - [email protected] 0844 556 1818
Table of contents
Popular Shower Cabin manuals by other brands

THE SHOWER LAB
THE SHOWER LAB VIEW 25 manual

Sanotechnik
Sanotechnik TR20 Mounting instructions

Dreamline
Dreamline UNIDOOR MADRID D245872MB01 Series installation instructions

Sapa
Sapa Alumax ProLine PL60 installation instructions

Sanotechnik
Sanotechnik CL96 Assembly guide

Aurlane
Aurlane CAB270 Installation