Timer is ON and connected MistKing® system is misting
Timer is OFF and idle
Current time clock
System is in day mode
System is in night mode
LCD Display
Setup Instructions:
1. Set Current Time (picture A):
In normal status, press “
O
” key once to set the current time.
Press “
O
” key to switch between hour, minute and seconds.
Press up arrow or down arrow to adjust the values when ashing.
N
NOTE: Clock is in 24H mode and not AM/PM
2. Set ON duration for DAY & NIGHT modes
a. Set the “MODE” (picture B):
In normal status, press “SET” key once, the current mode ashes, press up arrow or down arrow key to
switch between “AUTO, ON and OFF”. Choose the desired mode, then press “SET” key once.
ON - Always ON
OFF - Always OFF
A
AUTO - uses congured cycle programs for Day and Night
NOTE: Programmed functions work only in AUTO mode
b. Set ON duration for day - “DAY START” time (picture C):
When ”hour” of “DAY START” ashes, press “
O
”key to switch between hour, minute and second; press
“up arrow” or “down arrow” to adjust the values when ashing.
c. Set “NIGHT START” time (picture D):
AAfter setting “DAY START” time setting, press “SET” key once. When ”hour” of “NIGHT START” ashes,
press “
O
”key to switch between hour, minute and second; press “up arrow” or “down arrow” key to
adjust the value when ashing.
3. Set OFF duration for DAY & NIGHT modes:
REMEMBER: Programmed operation of the timer works only in AUTO mode (see 2a)
a. Set “DAY STOP” time (picture E):
A
L
L
L
L
MistKing® Repeat Cycle Timer (RCT-24) is ideally suited to control MistKing® misting system in repeated patterns. Please note that you
can have different ON and OFF cycles during the day and night. RCT-24 is a perfect choice for aeroponics and many plant growing
applications. Current time, length of ON and OFF for Day and Night cycles, as well as DAY and NIGHT start can all be configured.
M
MistKing® Repeat Cycle Timer does not use a photo cell to specify Day and Night modes. In our experience, a photo cell often incorrectly
gauges the start of day and night due to physical timer placement, shade, and conditions of the environment, which leads to undesired
configurations and user preferences. Instead of a photo cell, MistKing® timers rely on specific Day and Night times controlled by an
internal clock. Extending Day and Night, if needed, is very easily accomplished.
E
Example: Current Time 3:30 pm. Day starts at 6am, Night set to start at 6 pm. Day ON 4sec, OFF 2 min. Night ON 5 sec OFF 60 min. The
timer will work in a continuous and repeating pattern during the day, misting for 4 sec every 2 min. At 6 pm, it will switch into NIGHT
mode and will mist for 5 sec every 60 min.
Model: RCT-24
Repeat Cycle Timer
Repeat Cycle Timer Connection
1.
Connect the BLUE lead on the repeat cycle controller to the
power adapter of your MistKing misting system.
2.
Connect the BLACK lead to your pump and ZipDrip (if
available). DO NOT plug ZipDrip to blue lead.
NOTE: Repeat controller works only with MistKing
systems and therefore requires additional Mistking
components to work properly.
Using the repeat cycle timer with
non-MistKing equipment voids warranty.