7.Troubleshooting
Takethefollowingactionsiftroubleshowninthetablebelowoccurs.
Iftroubleisnotcorrectedevenaftertakingtherequiredaction,oriftroubleotherthanthatindicatedinthe
followingtableoccurs,turnOFFtheisolator,andthencontactyourdealeroranelectricalcontractor.
Symptom Cause Action
No operation Power is not supplied to the product. Check the circuit breaker on the power board.
The button on the controller is not [ON]. Press the button on the controller to turn on.
There is a sound from the
product
The sound of fans moving and the sound of winds
owing.
It is not a malfunction.
Operating noise has
increased
The lter is not installed securely. Re-install the lter. (see section 6.)
The lter is clogged. Clean the lter. (see section 6.)
The outdoor hood is blocked. Remove obstacles.
Air ow has reduced The lter is clogged. Clean the lter. (see section 6.)
Burbling noise from the
product
Dew condensation water in the drain pipes is sucked
into the wind taken in by the product but is not being
discharged.
Reduce the fan speed of the product.
The noise will disappear as it becomes easier to
discharge the dew condensation water in the drain
pipes.
Noise uctuates Noise sometimes gets louder because of the
inuence of outdoor wind. This is not a malfunction.
If you are worried about sound uctuation, contact your
dealer or an electrical contractor.
Dew condensation water in
the lter case
Dew condensation water sometimes builds up in
some operating environments.
It is not a malfunction.
The volume of the operating
noise is dierent in dierent
rooms
The volume of the noise sometimes diers, for
example, because of the length of the piping to each
room.
It is not a malfunction.
During winter season,
Sometimes supply air stops.
The product is operating in the supply air intermittent
mode.
It is not a malfunction.
See Automatic supply air stop function/Automatic
supply air intermittent operation function. (see next
page.)
Supply air ow is cold The outdoor air temperature is low. It is not a malfunction.
Supply air sometimes is cooled be the outdoor air.
Small insects intrude into the
indoor through the supply air
vent.
Small insects could intrude into the indoor from the
outdoor through the product.
It is not a malfunction.
The volume of intruding insects can be reduced by
using the high performance lter (optional parts).
Condensation occurs on the
outside of the product.
If the outdoor temperature is low or the indoor
humidity is high, condensation can occur outside the
product.
It is not a malfunction.
Remove the condensation with a cloth.
Inside the product or the lters
are wet.
Inside the product or the lters can become wet due
to fog outdoor or condensation.
It is not a malfunction.
Condensation occurs on the
outlet of the supply air vent.
If the outdoor or indoor humidity is high, condensation
can occur.
It is not a malfunction.
Remove the condensation with a cloth.
The air volume increases/
decreases without any
command.
The air volume can increase/decrease automatically
if the product receives external output.
It is not a malfunction.
Check the setting.
Whenthecontrollerisnotworking:
Symptom Cause Action
The OFF button does not
function to stop the product.
The Enable OFF button is set to invalid. (At factory
default settings, the Enable OFF button is set to No.)
It is not a malfunction.
If the Enable OFF button is set, turn the isolator OFF to
stop the product.
To cancel the Enable OFF button setting, see 6.4.2.7
Control mode in the Installation Manual.
Ventilation mode (bypass,
auto bypass) cannot be
selected.
Due to the skip setting.
(At factory default setting, the bypass ventilation is
set to Skipped.)
It is not a malfunction.
To cancel the skip setting, see 6.4.2.7 Control mode in
the Installation Manual.
The fan speed ( , , ,
or ) cannot be selected.
Due to the skip setting.
(At factory default setting, is Skipped.)
It is not a malfunction.
To cancel the skip setting, see 6.4.2.7 Control mode in
the Installation Manual.
The air volume is changed
without any command.
To protect the Heat exchanger from frost in winter,
the air volume can increase/decrease.
It is not a malfunction.
The air volume can increase/decrease automatically
if the product receives external output.
The air volume is not changed
even when the product fan
speed is changed.
When receiving the external input, the priority is
given to it even when the lower fan speed is selected.
(External input icon is displayed if the fan speed is
determined by the external input.)
It is not a malfunction.