1
2
3
4
5
6
7
8
9
10
11
12
13
14
1
2
3
4
5
6
7
8
9
10
11
12
13
14
2 2
2 2 2
ECB1
L
(1)
N
(3)
L
(1)
N
(3)
ECB2
BHCP
ORN
RED
BLU
BLU
BLU
BLU
RED
RED
BLU
BLU/No.3
WHT/No.2
WHT/No.1
BLU/No.4
RED
RED
VLT
VLT
PNK
PNK
GRY
GRY
ORN
BHC2
IHC BHC1
BHT
IHT
IH
642
531 A1
A2
642
531 A1
A2
642
531 A1
A2
BH1
A B
BHF
BH2
24
24
Power supply
to Immersion heater
~/N 230V 50Hz
Power supply
to Booster heater
~/N 230V 50Hz
2
2
2
2
1
3
5
7
1
5
X1
X2
X3
X4
X5A
X12
X11
X6
X8
X7
TBO.2
5
3
1
F1
F2
CN01
(BLK)
Signal
output
(Error)
Signal
output
(Defrost)
Signal
output
(Booster
heater2+)
3WV
M
1
~
MXV
M
1
~
M
1
~
MP2
M
1
~
MP3
MP1
M
1
~
1
3
CNP1
(WHT)
1
3
1
3
Signal
output
(Boiler)
CNV1
(WHT)
1
3
CNPWM
(WHT)
CNIH
(ORN)
21
3CNBHT(BLK)
X5B
X10
CNBC
(GRY)
CNBH
(WHT)
TBO.1
X9
642
531 A1
A2
Open
Close
N
3
EHST20C-VM6EB WIRING DIAGRAM
Table 1 Signal Inputs
Name
Terminal block Connector
Item OFF (Open) ON (Short)
IN1 TBI.1 1-2
— Room thermostat 1 input
Refer to SW2-1 in <6-13Dip switch setting>
IN2 TBI.1 3-4 CN2F
Flow switch 1 input
Refer to SW2-2 in <6-13Dip switch setting>
IN3 TBI.1 5-6
— Flow switch 2 input (Zone1)
Refer to SW3-2 in <6-13Dip switch setting>
IN4 TBI.1 7-8
— Demand control input
Normal
Heat source OFF/Boiler operation *2
IN5 TBI.1 9-10
— Outdoor thermostat input *1
Standard operation
Heater operation/Boiler operation *2
IN6 TBI.1 11-12
— Room thermostat 2 input
Refer to SW3-1 in <6-13Dip switch setting>
IN7 TBI.1 13-14
— Flow switch 3 input (Zone2)
Refer to SW3-3 in <6-13Dip switch setting>
*1. If using outdoor thermostat for controlling operation of heaters, the lifetime of the heaters and
related parts may be reduced.
*2. To turn on the boiler operation, use the main controller to select “Boiler” in “External/input setting“
screen in the service menu.
Symbol Name Symbol Name
TB1
Terminal block <Power supply, Outdoor unit>
TH1 Thermistor (Room temp.)(Option)
ECB1
Earth leakage circuit breaker for booster heater
TH2 Thermistor (Ref. liquid temp.)
ECB2
Earth leakage circuit breaker for immersion heater (Option)
THW1 Thermistor (Flow water temp.)
MP1
Water circulation pump1(Space heating & DHW)
THW2 Thermistor (Return water temp.)
MP2 Water circulation pump2
(Space heating for Zone1)(Field supply) THW5 Thermistor (DHW tank water temp.)
THW6 Thermistor (Zone1 flow temp.)(Option)
MP3 Water circulation pump3
(Space heating for Zone2)(Field supply) THW7 Thermistor (Zone1 return temp.)(Option)
THW8 Thermistor (Zone2 flow temp.)(Option)
3WV 3-way valve THW9 Thermistor (Zone2 return temp.)(Option)
MXV Mixing valve (Field supply)
THWB1
Thermistor (Boiler flow temp.)(Option)
BHT Thermostat for booster heater
THWB2
Thermistor (Boiler return temp.)(Option)
BHF Thermal fuse for booster heater IN1 Room thermostat 1 (Field supply)
BH1 Booster heater 1 IN2 Flow switch 1
BH2 Booster heater 2 IN3 Flow switch 2 (Field supply)
BHC1 Contactor for booster heater 1 IN4 Demand control (Field supply)
BHC2 Contactor for booster heater 2 IN5 Outdoor thermostat (Field supply)
BHCP Contactor for booster heater protection IN6 Room thermostat 2 (Field supply)
IHT
Thermostat (fixed temp.) for immersion heater (Option)
IN7 Flow switch 3 (Field supply)
IH Immersion heater (Option)
FLOW TEMP. CONTROLLER (FTC4)
IHC Contactor for immersion heater (Option)
TBO.1~2
Terminal block <Outputs>
TBI.1~2
Terminal block <Signal Inputs, Thermistor>
F1~F2
Fuse (T6.3AL250V)
SW1~4
Dip switch *See <6-13 Dip switch setting>
X1~X12
Relay
LED1 Power supply (FTC4)
LED2 Power supply (Main controller)
LED3 Communication (FTC4-Outdoor unit)
LED4 Reading or writing data to SD card
CNPWM
Pump speed control signal for MP1
CN108
SD card connector
NL
S3S2S1
NL
S3S2S1
Figure 1
To outdoor
unit
TB1
ORN ORN
YLW
BLK BLK
YLW
GRN/YLW
To outdoor
unit
Power supply
~/N 230V 50Hz
TB1
ORN
BLU
RED
BLU
RED
YLW
GRN/YLW
1
3
CN3C
(BLU)
5
3
1
1
3
5
3
1
CN01
(BLK)
ORN
BRN
CN3C
(BLU)
CN01
(BLK)
ORN
ORN
BRN
YLW
Cylinder unit powered
by independent source.
Cylinder unit powered
via outdoor unit
CIRCUIT
BREAKER
TBO.1
3
9
5
1
7
2
8
4
6
11 10
12
13 14
TBO.2
FTC4
3
9
5
1
7
2
8
4
6
11 10
12
13 14
TBI.1
126 610
14
8137 119
453
2
1TBI.2
1210 148
13
7
11
9
4
5
3
2
1
1 3
CNP1(WHT)
1
5CNV1
(WHT) 1
3
CN3C
(BLU)
5
3
1
CN01
(BLK)
1 8
SW3 1 8
SW1
LED1
LED3
1
1
8
6
SW2
SW4
TBI.1 13
10 12 14
11
7
4 6
5 9
3
281 TBI.2 13
10 12 14
11
7
4 6
5 9
3
281
12
CN20
(RED)
TH1
13
CN21
(YLW)
TH2
14
THW1
1213
IN2
IN7
IN6
IN5
IN4
IN3
IN1
t
°
t
°
THWB2
THWB1
THW8
t
°
THW6
t
°
THW7
t
°
THW9
t
°
Main
controller
12
THW2
THW5 CNW5
(WHT)
CNW12
(RED)
t
°
t
°
t
°
t
°
t
°
1
3
1
7
CN2F
(YLW) CN20
(RED) CN21
(YLW)
CNW12
(RED)
CNW5
(WHT)
1
2
1
2
CN108
1
3
13 13
CNBH
(WHT)
CNBHT
(BLK)
13
CNIH
(ORN)
CNBC
(GRY)
1
7
LED4
LED2
1
2
CN22
(BLU)
CNPWM
(WHT)
1
3
5
1
Wireless receiver
(Option)
CNRF
(WHT)
5
1
CN105
(RED)
CN2F
(YLW)
CN22
(BLU)
Table 2 Outputs
Name
Terminal block Connector
Item OFF ON
OUT1
TBO.1 3-4
CNP1
Water circulation pump 1 output (Space heating & DHW) OFF ON
OUT2
TBO.1 5-6
—
Water circulation pump 2 output (Space heating for Zone1) OFF ON
OUT3
TBO.1 7-8
—
Water circulation pump 3 output (Space heating for Zone2) OFF ON
OUT4
TBO.1 9-11
CNV1
3-way valve output Heating DHW
OUT5
TBO.1 12-13
—
Mixing valve output Stop Close
TBO.1 13-14 Stop Open
OUT6
—
CNBH 1-3
Booster heater 1 output OFF ON
OUT7
—
CNBH 5-7
Booster heater 2 output OFF ON
OUT8
TBO.2 11-12
—
Booster heater 2+ output OFF ON
OUT9
TBO.2 9-10
CNIH
Immersion heater output OFF ON
OUT10
TBO.1 1-2
—
Boiler output OFF ON
OUT11
TBO.2 1-2
—
Error output Normal Error
OUT12
TBO.2 3-4
—
Defrost output Normal Defrost
1. Symbols used in wiring diagram are,
: connector, : terminal block.
2. Indoor unit and outdoor unit connecting wires
have polarities, make sure to match terminal numbers
(S1, S2, S3) for correct wirings,
3. Since the outdoor unit side electric wiring may change,
be sure to check the outdoor unit electric wiring
diagram for servicing.
4. This diagram shows the wiring of indoor unit and
outdoor unit connecting wires (specification of 230V),
adopting superimposed system of power and signal.
When work to supply power separately to indoor
unit and outdoor unit was applied, refer to Figure 1.
6-5. EHST20C-VM6EB