Certified for US EPA-Tier 2 / Constant Speed
Standard Model [1000kWe/60Hz] MITSUBISHI
S12H-Y2PTAW-1 SPECIFICATION SHEET DIESEL ENGINES
GENERAL ENGINE DAT
Type 4-Cycle, Water Cooled
Aspiration Turbo-Charged, Inter Cooler
(Fresh water to Cooler)
Cylinder Arragement 60oV
o.of Cylinder
12
Bore mm(in.) 150 (5.91)
Stroke mm(in.) 175 (6.89)
Displacement liter(in3) 37.11 (2265)
Compression Ratio 14.5:1
Dry Weight - Engine only - kg(lb) 4300 (9482)
Wet Weight - Engine only - kg(lb) 4560 (10055)
PERFORMANCE DAT
Steady State Speed Stability Band at any Constant Loa
Electric Governor - % ±0.25 or better
Maximum Overspeed Capacity - rpm 2000
Moment of inertia of Rotating Components - kgf・m2(lb
・f
2) 55.6 (1319.6)
(Includes Std.Flywheel
Cyclic Speed Variation with Flywheel at 1800rpm 1/523
ENGINE MOUNTIN
Maximum Bending Moment at Rear Face of Flywheel Housing - kg
・m(lb
・ft) 200 (1446.9)
AIR INLET SYSTE
Maximum Intake Air Restriction (Includes piping)
With Clean Filter Element - mm H2O (in.H2O) 400 (15.7)
With Dirty Filter Element - mm H2O (in.H2O) 635 (25.0)
EXHAUST SYSTE
Maximum Allowable Back Pressure - mm
2O (in.H2O) 600 (23.6)
LUBRICATION SYSTE
Oil Pressure at ldle - kgf/cm2(psi) 2〜3 (29〜43)
at Rate Speed - kgf/c
2(psi) 5〜6 (71〜86)
Maximum Oil Temperature - oC(oF) 110 230
Oil Capacity of Standard Pan High - liter (U.S.gal) 180 (48)
Low - liter (U.S.gal) 150 (39.6)
Total System Capacity (lncludes Oil Filter) - liter (U.S.gal) 200 (52.8)
Maximum Angle of lnstallation (Std. Pan) Front Down 9.5o
(Engine Only) Front Up 11o
Side to Side 22.5o
COOLING SYSTE
Coolant Capacity of Jacket (Engine only) - liter (U.S.gal) 83 (21.9)
Coolant Capacity of Air cooler (Engine only) - liter (U.S.gal) 17 (4.5)
Maximum External Friction Head at Engine Outlet - kgf/cm 2(psi)
(For Jacket and Air Cooler) 0.35 (5.0)
Maximum Static Head of Coolant above Crankshaft Center - m(ft) 10 (32.8)
Standard Thermostat (modulating)Range of Jacket - oC(oF) 71〜85 (160〜185)
Standard Thermostat (modulating)Range of Air Cooler - oC(oF) 35〜50 (95〜122)
Maximum Coolant Temperature at Engine Outlet of Jacket - oC(oF) 98 (208)
Minimum Coolant Expansion Space - % of System Capacity
(For Jacket and Air Cooler) 10 (0.4)
Maximum Coolant Temperature at Intercooler lnlet, PTAW type - oC(oF) 45 (113)
Maximum Air Restriction on Discharge Side of Radiator and Fan - mm H 2O(in.H2O) 10 (0.4)
APPLICATION : GENERATO
Pub. No. T13-0633-E
Dec. '06 Printed in Japan