Main Features
SMART CHILL - Variable air velocity.
RC50-26 - 50kg Blast Chill capacity per cycle
or 25kg Blast Freeze capacity per cycle.
RC70-36 - 70kg Blast Chill capacity per cycle
or 50kg Blast Freeze capacity per cycle.
Food product is required to be correctly portioned
in Gastronorm pans/bakery trays.
Removable and adjustable shelf runners able to
accept Gastronorm pans and Euro standard 600mm
x 400mm bakery trays.
Temperature display in °C.
Mode selection timer or four point Frigiprobe
by internal food temperature.
Automatic preservation
mode at the end of cycle.
Defrost feature removes
ice from evaporator.
R404A refrigerant -
CFC free.
Self-closing door
magnetically seals. Door
remains open past 90°C
for convenient loading
and unloading.
Internal coved corners,
removable door gasket.
Water protection index
rating IP459.
Adjustable legs for
levelling.
(Remote condensing unit not included.)
Description
Foodservice & Bakery Reach-In Blast Chiller/Freezer
designed to accept Gastronorm 1/1 pans or Euro 600mm
x 400mm bakery racks.
(Remote condensing unit not included.)
RC50-26A Blast Chill/Freeze RC70-36S Blast Chill/Freeze
Refrigeration Equipment RC50-26S only
•Complete remote condensing unit.
Suitable for local conditions.
•Condensing capacity upright Blast
Chiller 1000/3500W for the respective
evaporation temperatures of -40/-20°C.
•Remote condensing unit with ‘pump
down’ control.
Refrigeration Equipment RC70-36S only
•Complete remote condensing unit.
Suitable for local conditions.
•Condensing capacity upright Blast
Chiller 2700/8600W for the respective
evaporation temperatures of -40/-20°C.
•Remote condensing unit with ‘pump
down’ control.
Disclaimer:
All unit capacities are based on subjective
testing. Moffat accepts no liability for
production values.
A = Electrical Power Supply
B = Defrosting Water Runoff
SG = Without condensing unit
D = Liquid line
D' = Suction Line
590 (D)
385 (B)
350 (D')
60
531
445 (CU)
1500
120 (A)
A = Electrical Power Supply
B = Defrosting Water Runoff
D = Liquid line
D' = Suction Line
430 (D')
580 (B)
150
70 (MIN)
790
1130 (CU)
770
1906
190 (A)
230 (D)
120 (A) 60
400 (D')
340 (D)
1500
531
445 (CU)
150
790
1500 (CU)
1782
1950 (D, D')
160 (B)
770
2085 (SG)
385 (B)
In line with policy to continually develop and improve its products, Moffat Ltd. reserves the right to change specifications and design without notice.
www.moffat.com.au
Printed in New Zealand Copyright Moffat Ltd Moffat/ 649/BH/3M/11.0
Australia
Moffat Pty Ltd
Victoria/Tasmania
740 Springvale Road
Mulgrave,Victoria 3 70
Telephone 03-95 8 3888
Facsimile 03-95 8 3833
Email [email protected]
www.moffat.com.au
New South Wales
Telephone 02-8833 4
Email [email protected]
South Australia
Telephone 08-8274 2 6
Email [email protected]
New Zealand
Moffat Ltd
Christchurch
Telephone 03-389 007
Email [email protected]
www.moffat.co.nz
Auckland
Telephone 09-574 3 50
Email [email protected]
Queensland
Telephone 07-3630 8600
Email [email protected]
Western Australia
Telephone 08-9305 8855
Email [email protected]

This manual suits for next models

1

Other Moffat Chiller manuals

Moffat Friginox TSR-11A User manual

Moffat

Moffat Friginox TSR-11A User manual

Moffat Friginox RR36A User manual

Moffat

Moffat Friginox RR36A User manual

Moffat Friginox TSR-11SC User manual

Moffat

Moffat Friginox TSR-11SC User manual

Moffat Friginox RC15-7A User manual

Moffat

Moffat Friginox RC15-7A User manual

Moffat Blast Chillers and Freezers User manual

Moffat

Moffat Blast Chillers and Freezers User manual

Moffat Friginox RC50-26A User manual

Moffat

Moffat Friginox RC50-26A User manual

Moffat Friginox RR11A User manual

Moffat

Moffat Friginox RR11A User manual

Popular Chiller manuals by other brands

York W1LC420 Installation instruction

York

York W1LC420 Installation instruction

Nordcap SF 19/15-CW CRIO CHILL manual

Nordcap

Nordcap SF 19/15-CW CRIO CHILL manual

KoolMore OF-700 Instructions for use

KoolMore

KoolMore OF-700 Instructions for use

Nibe CLIMA COOL UCA 20 Installation, operation & maintenance manual

Nibe

Nibe CLIMA COOL UCA 20 Installation, operation & maintenance manual

Liebert Process Fluid Chiller PS048A Specification sheet

Liebert

Liebert Process Fluid Chiller PS048A Specification sheet

Carrier 61AF operating instructions

Carrier

Carrier 61AF operating instructions

SCV KJR-120F user manual

SCV

SCV KJR-120F user manual

Zanussi 110723 Specifications

Zanussi

Zanussi 110723 Specifications

Daikin EWAH TZ D Series Installation, operation and maintenance manual

Daikin

Daikin EWAH TZ D Series Installation, operation and maintenance manual

Western Zeta Rev HE FC APPLICATION AND OPERATING PRINCIPLE

Western

Western Zeta Rev HE FC APPLICATION AND OPERATING PRINCIPLE

Johnson Controls York YCAL0012-0032 Start-Up Checklist

Johnson Controls

Johnson Controls York YCAL0012-0032 Start-Up Checklist

York YK Series Operation and maintenance

York

York YK Series Operation and maintenance

Kaysun KEM-30 DNH3 Technical manual

Kaysun

Kaysun KEM-30 DNH3 Technical manual

IKA RC 2 lite manual

IKA

IKA RC 2 lite manual

Daikin WSC Installation, operation and maintenance manual

Daikin

Daikin WSC Installation, operation and maintenance manual

Samsung DVM installation manual

Samsung

Samsung DVM installation manual

Trane Picco R32-140 User& installer's manual

Trane

Trane Picco R32-140 User& installer's manual

Thermocold DOMINO BASIC Series user manual

Thermocold

Thermocold DOMINO BASIC Series user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.