Pressing any other button than 0, 1 to 5 is evaluated as invalid command and system requests to
input command again. If user inputs 3 times invalid command in the sequence then phone call is
terminated.
In the case checkbox No.24 is activated and during phone call was given command „3“ then
immediately after phone call termination Status SMS will be sent to the user (caller phone).
Communication (playing voice messages) can be selected in one from 14 languages. Language selection
which will be used for voice messages (parameter LANG) can be done by SMS command 281:
xxxx281-LANG=LL, xxxx is user password and LL is positive whole number in range 1 to 14.
(1 = English, 2 = German, 3 = Slovak, 4 = Czech, 5 = Swedish, 6 = Norwegian, 7 = Polish, 8 = French, 9 =
Russian, 10 = Hungarian, 11 = Finish, 12 = Danish, 13 = Italian, 14 = Spanish).
2.4. Heater control by ON/OFF push button with LED indication (orange LED)
Heater/ventilation is possible to control by ON/OFF push button installed in the vehicle:
Function Description Status indications / SMS
Switch
heater ON Short pressing of the push button (max. 1 second).
The heater will be ON depending on parameter HTP
preset time in the range of 1 to 120 minutes or
unlimited in the case HTP=999.
If checkbox No.7 is activated then SMS “Heater ON by
switch, MMM min., ±ttt.t C, vv.v V“ is sent to the first
VIP phone number.
After button release LED will lit ON
indicating heater status „ON“.
Switch
ventilation
ON
The same as for heating but LED will flash.
If checkbox No.11 is activated then SMS “Ventilation
ON by switch, MMM min.,
±ttt.t C, vv.v V“
is sent to the
first VIP phone number.
After button release LED will flash
indicating ventilation status „ON“.
Switch
heater OFF
Short pressing of the push button (max. 1 second)
when heater/ventilation is ON.
If checkbox No.3 is activated then SMS “Eberspaecher
OFF by switch,
±ttt.t C, vv.v V“
is sent to the first VIP
phone number.
After button release LED will
switch OFF indicating status „OFF“
Heater /
ventilation
mode
change
Pressing of the push button for 5 seconds will toggle
heater/ventilation mode. After 5 seconds LED will start
to indicate actual mode - when entering heater mode
LED will lit 5 seconds while when entering ventilation
mode LED will quickly flash for 5 seconds. When this
indication starts release the push button to accept
mode change.
Note: heater/ventilation mode change perform only
when heater/ventilation is OFF, otherwise LED
indication can not be seen correctly.
After 5 seconds LED will start
indication of mode change.
Indication of entered mode lasts 5
seconds, during this period release
the button to accept mode change.
Then system indicates new mode
by 5 seconds lit for heater mode or
5 seconds flashing for ventilation
mode.
System
RESET Pressing of the push button for at least 40 seconds will
reset the system.
System RESET will restart CommandCall control unit,
will restart GSM module, resets outputs overload
protection circuits and clears internal counters.
System RESET will not change checkboxes
settings or preset values (UST, TS, ..., timer preset).
After 5 seconds LED will flash 5
times - please keep push button
pressed. When the time 40 sec. is
reached LED will flash 4 times -
release the push button now.
After release of push button LED
will lit 2 sec. to indicate RESET
Backup
battery cut
OFF
Press and hold the push button for at least 20 seconds
when the power is OFF, this will cut OFF
CommandCall backup battery
After cutting off backup battery all
LEDs will switch OFF
Note: Status will be changed after button is released (system reacts on signal „fall down edge“).