9
5. Setting up the device
Menu level Parameterisation level
User code (4-digit number-combination, free available), :
Default:
If this code was set (>0000), all parameters are locked for the user, if has been
selected before under menu item . By pressing [P] for 3 seconds in operation
mode, the display shows . The needs to be entered to get to the
reduced number of parameter sets. The code has to be entered before each
parameterisation, until the (Master code) unlocks all parameters again.
Master code (4-digit number-combination, free available), :
Default:
All parameters can be unlocked with this code, after has been activated under
menu item . By pressing [P] for 3 seconds in operation mode, the display
shows and enables the user to reach all parameters by entering the .
Under the parameterisation can be activated permanently by selecting or
, thus at an anew pushing of [P] in operation mode, the code needs not to be
entered again.
5.3. Programming interlock
Activation / deactivation of the programming lock or completion of the
standard parameterisation with change into menu group level (complete
function range),
Default:
With the navigation keys [▲] [▼], choose between the deactivated key lock
(works setting) and the activated key lock , or the change into the menu group
level . Confirm the selection with [P]. After this, the display confirms the
settings with "and automatically switches to operating mode. If was
selected, the keyboard is locked. To get back into the menu level, press [P] for 3
seconds in operating mode. Now enter the (works setting ) that appears
using [▲] [▼] plus [P] to unlock the keyboard. appears if the input is wrong.
To parameterise further functions needs to be set. The device confirms this
setting with „ „ and changes automatically in operation mode. By pressing [P]
for approx. 3 seconds in operation mode, the first menu group is shown in the
display and thus confirms the change into the extended parameterisation. It stays
activated as long as or is entered in menu group .