Morrison Bros. co. 1218C Manual

1
Morrison Bros. Co. ‑ Dubuque, IA ‑ 800‑553‑4840
1218C‑0198 PP
rev. 3-22-18
!
The 1218C Cellular Gateway Assembly is an accessory to the 1218C Electronic Tank Gauge. The Cellular
Gateway provides a remote access to the 1218C using a private internet connection over a 4G cellular network.
Input Power
100 – 240 VAC, 50/60Hz
Operating Temperature
-40°F to 140°F (-40°C to 60°C)
Enclosure Rating
NEMA 4X
Maximum Wiring Distance
Ethernet – 330ft (CAT5e cable recommended)
Warnings
• Fire Hazard – Death or serious injury could result from spilled liquids.
• You must be trained to install or maintain this Electronic Tank Gauge. Stop now if you have not been trained.
• Anymodicationofthisunitbeyondwhatisoutlinedinthisinstructionwillvoidproductwarranty.
• For your safety, it is important to follow local, state, federal and/or OSHA rules that apply to working
inside, above, or around the storage tank and piping area. Use all personal protective equipment required for
workinginthespecicenvironment.
• This device is intended to be used as an auxiliary warning to the operator of an abnormal condition of
thesystem,suchasapossibleoverllsituationandshouldnotbetheonlysysteminplacetopreventan
unwantedcondition,suchaspreventingatankfromoverlling.Itisthesoleresponsibilityoftheoperatorto
continuously prevent any spillage regardless of the situation.
• Tankscouldbeunderpressure.Vaporscouldbeexpelledfromtankvents,piping,valvesorttingswhile
performingmaintenance.Vaporscouldcatchreorcauseanexplosion.Avoidsparks,opename,orhot
tools when working on tank system.
• Use a dampened cloth when cleaning the alarm enclosure to prevent static buildup and discharge.
• Intheeventofmalfunction,contactMorrisonBros.Co.CustomerService.

2
Morrison Bros. Co. ‑ Dubuque, IA ‑ 800‑553‑4840
1218C‑0198 PP
rev. 3-22-18
!
• Risque d’incendie – Un déversement de liquide pourrait entraîner des blessures graves ou la mort.
• Vous devez avoir reçu une formation pour installer cette jauge de réservoir électronique ou en assurer la
maintenance. Arrêtez-vous immédiatement si vous n’avez reçu aucune formation à cet effet.
• Touteslesmodicationsapportéesàcetteunitéautresquecellesindiquéesdanscesdirectivesengendreront
l’annulation de la garantie du produit.
• Pour assurer votre sécurité, il est important de vous conformer à la réglementation locale, d’État, fédérale
ou OSHA régissant les travaux à l’intérieur, au-dessus ou autour du réservoir de stockage et de la zone de
canalisation. Utilisez tout l’équipement de protection individuelle exigé pour travailler dans l’environnement
spécique.
• Cet appareil est destiné à être utilisé comme mécanisme avertissant l’opérateur d’un état anormal du système
tel une situation de remplissage excessif et ne devrait pas être le seul système en place pour empêcher un état
indésirable, par exemple, un réservoir qui se remplit trop. L’opérateur a l’entière responsabilité de s’assurer
continuellement de prévenir tout déversement, quelle que soit la situation.
• Les réservoirs pourraient être sous pression. Des vapeurs pourraient être expulsées des conduits d’aération,
des canalisations, des soupapes ou des raccords du réservoir durant la maintenance. Les vapeurs pourraient
s’enammerouengendreruneexplosion.Évitezlesétincelles,lesammesnuesoulesoutilschaudslorsde
travaux menés dans le système du réservoir.
• Utilisezunlingehumidepournettoyerl’enceintedel’alarmeandeprévenirl’accumulationd’électricité
statique et les décharges.
• Encasdedéfaillance,communiquezavecleserviceàlaclientèledeMorrisonBros.Co.
WARNING: ThisdeviceisintendedtobeinstalledinanOrdinaryLocation(UnclassiedLocation)andbe
used with other Ordinary Location devices.
Mounting
To maintain the NEMA 4X rating:
•TwoopeningshavebeenprovidedinthebottomoftheNEMA4Xenclosureforconnectionandwiring.
OnlyuseThomas&BettsCat.No.H050GR-TBorH050-TBorequivalenthubsinthetwoopeningsfor
½” conduit.
•Mountingtabshavebeenprovidedwiththeproducttomounttheenclosure;donotmakeadditionalholes
in this enclosure.
•Ensurethatbothcoverlatchesarelatchedatalltimes.
Failure to follow these instructions voids any assurance that the enclosure is NEMA 4X.

3
Morrison Bros. Co. ‑ Dubuque, IA ‑ 800‑553‑4840
1218C‑0198 PP
rev. 3-22-18
!
Wiring
The Cellular Gateway must be connected to the 1218C Electronic Tank Gauge console with an Ethernet cable.
An Ethernet Switch device such as the 1218C-0171 AS (5-Port) or 1218C-0172 AS (8-Port) can be used to
connect the Cellular Gateway to more than one 1218C console. Figure 1 shows the Ethernet connection to the
Cellular Gateway.
Figure 1 shows the AC input wiring required for the Cellular Gateway. The AC input voltage must be 100-240
VAC(50/60Hz).ItisrecommendedtouseadedicatedbreakerforpoweringtheCellularGatewayand1218C
console(s), separate from other devices like solenoids, pumps, etc.
Warnings
• Fire Hazard – Death or serious injury could result from spilled liquids.
• You must be trained to install or maintain this Electronic Tank Gauge. Stop now if you have not been trained.
• Anymodicationofthisunitbeyondwhatisoutlinedinthisinstructionwillvoidproductwarranty.
• For your safety, it is important to follow local, state, federal and/or OSHA rules that apply to working
inside, above, or around the storage tank and piping area. Use all personal protective equipment required for
workinginthespecicenvironment.
• This device is intended to be used as an auxiliary warning to the operator of an abnormal condition of
thesystem,suchasapossibleoverllsituationandshouldnotbetheonlysysteminplacetopreventan
unwantedcondition,suchaspreventingatankfromoverlling.Itisthesoleresponsibilityoftheoperatorto
continuously prevent any spillage regardless of the situation.
• Tankscouldbeunderpressure.Vaporscouldbeexpelledfromtankvents,piping,valvesorttingswhile
performingmaintenance.Vaporscouldcatchreorcauseanexplosion.Avoidsparks,opename,orhot
tools when working on tank system.
• Use a dampened cloth when cleaning the alarm enclosure to prevent static buildup and discharge.
• Intheeventofmalfunction,contactMorrisonBros.Co.CustomerService.
Figure 1 – Cellular Gateway connections

4
Morrison Bros. Co. ‑ Dubuque, IA ‑ 800‑553‑4840
1218C‑0198 PP
rev. 3-22-18
!
• Risque d’incendie – Un déversement de liquide pourrait entraîner des blessures graves ou la mort.
• Vous devez avoir reçu une formation pour installer cette jauge de réservoir électronique ou en assurer la
maintenance. Arrêtez-vous immédiatement si vous n’avez reçu aucune formation à cet effet.
• Touteslesmodicationsapportéesàcetteunitéautresquecellesindiquéesdanscesdirectivesengendreront
l’annulation de la garantie du produit.
• Pour assurer votre sécurité, il est important de vous conformer à la réglementation locale, d’État, fédérale
ou OSHA régissant les travaux à l’intérieur, au-dessus ou autour du réservoir de stockage et de la zone de
canalisation. Utilisez tout l’équipement de protection individuelle exigé pour travailler dans l’environnement
spécique.
• Cet appareil est destiné à être utilisé comme mécanisme avertissant l’opérateur d’un état anormal du système
tel une situation de remplissage excessif et ne devrait pas être le seul système en place pour empêcher un état
indésirable, par exemple, un réservoir qui se remplit trop. L’opérateur a l’entière responsabilité de s’assurer
continuellement de prévenir tout déversement, quelle que soit la situation.
• Les réservoirs pourraient être sous pression. Des vapeurs pourraient être expulsées des conduits d’aération,
des canalisations, des soupapes ou des raccords du réservoir durant la maintenance. Les vapeurs pourraient
s’enammerouengendreruneexplosion.Évitezlesétincelles,lesammesnuesoulesoutilschaudslorsde
travaux menés dans le système du réservoir.
• Utilisezunlingehumidepournettoyerl’enceintedel’alarmeandeprévenirl’accumulationd’électricité
statique et les décharges.
• Encasdedéfaillance,communiquezavecleserviceàlaclientèledeMorrisonBros.Co.
Conguration
To enable remote access to the 1218C Electronic Tank Gauge console(s) through the Cellular Gateway, each
consolemustbeconguredtouseauniquestaticIPaddress.Thenetworksettingsofeachconsolemustbe
conguredperthenetworksettingsbelow.Referto‘ConguringYour1218C’ofthe‘StepstoCongurethe
1218C’sectioninthe‘1218CElectronicTankGaugeInstallation,Operation,andMaintenanceInstructions’for
detailsonconguringthenetworksettings.
IP Address: 192.168.1.11 – 192.168.1.15
Subnet Mask: 255.255.255.0
Default Gateway: 192.168.1.90
Primary DNS: 192.168.1.90
Secondary DNS: 8.8.8.8
Port: 443
To test the operation of the Cellular Gateway, start by powering on the device. After 10-60 seconds ensure the
middleLEDnexttotheEthernetportisonorashing.NextyouwillneedtocallOptConnectsupport(1-877-
678-3343) to activate device and get VPN credentials. Document the credentials below for future reference.
Username: ________________________________
Password: ________________________________
Go to https://dashboard.optconnect.com to register and login to the portal. Once logged into the portal check the
signalstrengthandsignalqualityoftheunit.YouwillalsoneedtodocumenttheIPaddressofthegateway.
Cellular Gateway IP Address: __ __ __ . __ __ __ . __ __ __ . __ __ __

5
Morrison Bros. Co. ‑ Dubuque, IA ‑ 800‑553‑4840
1218C‑0198 PP
rev. 3-22-18
Next,gotohttps://vpn.optconnect.comandloginusingtheVPNcredentials.Hereyouwillndalinkto
download the VPN software to your computer. Downloads are provided for various operating systems, select the
appropriate link.
Figure 2 – OptConnect Portal Login Page
Figure 3 – Cellular Gateway IP Address
Figure 4 – VPN Download Page Figure 5 – VPN Login Page

6
Morrison Bros. Co. ‑ Dubuque, IA ‑ 800‑553‑4840
1218C‑0198 PP
rev. 3-22-18
After downloading and installing the VPN, you will need to login and connect to the VPN. An OpenVPN icon
will be added to the System Tray in Windows after installation. Open the System Tray, click on the OpenVPN
icon and connect as shown in Figure 6.
Figure 6 – Connect to OpenVPN
Toaccessthewebpageofa1218Cconsole,youwillneedtousetheIPaddressoftheCellularGateway
(documented above) and the port number of the console you are trying to access. Table 1 provides a list of web
addressesrequiredtoaccesseachdeviceonthecellulargatewaynetwork.SubstitutetheCellularGatewayIP
Address for “[cellular_gateway_ip_address]” and omit the brackets (e.g. https://100.10.10.10:1443). Open a web
browser and enter the web address of the device and go to the page. Your internet browser will display a security
warningforthedevicewebpagewhichyouwillneedtoconrmandproceedthrough.Youwillthenbeprompted
to enter the username and password for the 1218C console (default username: admin, default password: admin).
Itisrecommendedtochangethepasswordatthistime.
Device IP Address WAN Port Web Address
192.168.1.11 1443 https://[cellular_gateway_ip_address]:1443
192.168.1.12 2443 https://[cellular_gateway_ip_address]:2443
192.168.1.13 3443 https://[cellular_gateway_ip_address]:3443
192.168.1.14 4443 https://[cellular_gateway_ip_address]:4443
192.168.1.15 5443 https://[cellular_gateway_ip_address]:5443
Table 1 – Web Addresses of Devices