Mosentek MS036 User manual

PRODUCT.:
MODEL NO.:
SPEC NO.:
MS036
Panel Light Microwave Motion Sensor
R & D DEPARTMENT
APPROVEDCHECKEDWRITED BY
Enabling Technology Serving PeopleModel: MS036
Add: Block H 5F; Huamingchen Hi-Tech Industry Park; Genyu Road; Matian Street; Guangming District; Shenzhen PRC. Email: [email protected] Tel: +86 0755 2720 6813
Panel Light Microwave Motion Sensor

5.8GHz dimming microwave motion sensor
DC input, PWM dimming output control
Compact size configuration suitable for panels; troffer; linears
Remote control setting.
5 years warranty.
Operating voltage
Operating current
Output
Microwave frequency
Microwave power
Detection angle
Sensitivity
Hold time
Daylight threshold
Stand-by period
Stand-by dimming level
Mounting height
Detection range
Operating temperature
IP rating
Warranty
11-15VDC
22mA
PWM
5.8GHz±75MHz
<0.3mW
≤150°
100%/75%/50%/25% (Refer to Remote Control)
3s/30s/90s/3min/5min/15min/20min/30min (Refer to Remote Control)
5Lux/15Lux/50Lux/100Lux/300Lux/Disable (Refer to Remote Control)
0s/5s/30s/3min/5min/15min/45min/+∞ (Refer to Remote Control)
10%/20%/30%/50% (Refer to Remote Control)
Max.5m (ceiling mounted); 1.5-1.8m (Wall Mounted)
Radius, Max.5m (ceiling mounted); Max.10m (Wall Mounted 1.8m)
-25°C~70°C
IP44
5 years
Other
Input
Output
Sensor
Parameters
Features
Technical data
- 01
Enabling Technology Serving PeopleModel: MS036
Add: Block H 5F; Huamingchen Hi-Tech Industry Park; Genyu Road; Matian Street; Guangming District; Shenzhen PRC. Email: [email protected] Tel: +86 0755 2720 6813
Mechanical structure (Unit: mm) Wiring diagram
15±2.0mm
300±10mm
Red: VCC
White: DIM
Black: GND
N
L
LED Driver
L
N
VCC
OUT
GND
VCC
DIM
GND
MS036
+
-
Antenna module
Daylight sensor
45.5
37.5
23
11.5 13.5
20

Application
With sufficient daylight, even
when motion detected, light
remains OFF.
With insufficient ambient
brightness, light dims to 100%
when motion was detected .
Light keeps on 100% within the
holdtime.
After the last detection and
the preset hold time elapsed,
light OFF.
When motion is detected, the
sensor will switch on the light to
100% brighteness.
After people leave the detection
area, light remains 100%
brightness within hold time.
After the last detection and
the present hold time elapsed,
light OFF.
2). The daylight threshold is set to "Disable". Light on when detect movement, After people leave, Light off after hold time.
1). The daylight threshold is set to "5Lux/15Lux/50Lux/100Lux/300Lux, Stand-by period is set to "0s".
1. ON/OFF function
- 02
Enabling Technology Serving People
Model: MS036
Add: Block H 5F; Huamingchen Hi-Tech Industry Park; Genyu Road; Matian Street; Guangming District; Shenzhen PRC. Email: [email protected] Tel: +86 0755 2720 6813
Detection coverage
Sensitivity : 25% 50% 75% 100%
4m
5m
7m
6m
Ceiling Mounted
3m
Mounting
height
1m
2m
0m 1m 2m 3m 4m 5m 6m1m2m
3m
4m
5m6m Wall Mounted
1m 2m 3m 4m 5m 6m 7m 8m 9m 10m 12m 13m11m 14m 15m
3m
4m
4m
3m
2m
2m
1m
1m
Mounting
height

With sufficient daylight, even
when motion detected, light
remains OFF.
With insufficient ambient
brightness, light dims to 100%
when motion was detected .
Light keeps on 100% within
the holdtime.
Light dims to standby level if
no motion detected after
holdtime.
After the stand-by period,
light OFF.
The daylight threshold is set to "5Lux/15Lux/50Lux/100Lux/300Lux, stand-by period is set to "5s/30s/3min/5min/15min/45min".
⑤
2. Dimmable control/Corridor function
①③④
②
Wiring must be strictly in accordance with the wiring diagram to avoid short circuit.
The detected surface cannot be shielded by metal objects.
Microwave sensor can be installed in any lamp except the one with full metal shell.
Should be kept away from the driver to avoid interference generation and lamp flashing.
Shall not be installed next to large operating machines such as ventilator/ceiling fan to avoid false triggering caused by machine vibration.
Suitable for indoor installation to avoid false triggering due to external factors such as rain, wind or tree swing.
Installation precautions
- 03
Enabling Technology Serving PeopleModel: MS036
Add: Block H 5F; Huamingchen Hi-Tech Industry Park; Genyu Road; Matian Street; Guangming District; Shenzhen PRC. Email: [email protected] Tel: +86 0755 2720 6813

- 04
Enabling Technology Serving PeopleModel: MR003
Add: Block H 5F; Huamingchen Hi-Tech Industry Park; Genyu Road; Matian Street; Guangming District; Shenzhen PRC. Email: [email protected] Tel: +86 0755 2720 6813
MR003 Programable one key commission remote controller
Front Back Side
MR003
Start Memory Apply Power
100%
Power
80%
25% 50%
Sensitivity
Hold time
Stand-by dimming level
Stand-by period
Daylight threshold Brightness
75%
ON/OFF Auto
Mode Reset
100%
3s 30s 90s 3min
5min 15min 20min 30min
10% 20% 30% 50%
0s 5s 30s 3min
5Lux 15Lux 50Lux ▲
+
100Lux 300Lux
Disable
-
▼
5min 15min 45min +∞
MR003
Start
Memory
Apply Power
100%
Power
80%
25% 50%
Sensitivity
Hold time
Stand-by dimming level
Stand-by period
Daylight threshold Brightness
75%
ON/OFF Auto
Mode
Reset
100%
3s 30s 90s 3min
5min 15min 20min 30min
10% 20% 30% 50%
0s 5s 30s 3min
5Lux 15Lux 50Lux ▲
+
100Lux 300Lux
Disable
-
▼
5min 15min 45min +∞
Size (L*W*H): 116.5*55*13mm
AAA battery is recommended
116.5mm
55mm 13mm
Remote Setting Tips: When press any button, if the light is flickering one time, means the setting
is successful.
The period of light keeping 100% brightness after
moving objects leave the detection area.
Definition of the ambient brightness; when the ambient brightness is
lower than the preset specific lux amount, the sensor will work; when
it's preset as "disable", the sensor will detects motion regardless the
ambient brightness.
The period of light keeping low output before it's completely switched
off. When it's preset as"+∞“, the light always keep at low output if no
movement in the detection area and doesn't turn off.
The dimming level in the standby period.
1. Press Start to program mode, then select the ①Sensitivity②
Holdtime③Standby dimming level④Standby period⑤Daylight
threshold to setting
2. Press Memory to save the parameters ①-⑤ had selected in step 1
3. Press Apply to transmit the ①-⑤ parameters to the target sensor
Remark :After press Start,you need to press any of ①-⑤parameter
button within 30S, the time windown between press any button is
30S , it will quit program mode if no any button is pressed within 30S.
Quick setting the power output in 80% or 100%
Long press this button to set the power from 20% to 100%, available
in permanent ON mode or in sensor mode.
ON/OFF
Turn the sensor in a default setting
(3s hold time, 0s stand-by period, lux disable, 100% sensitivity).
Reset
Power (80%/100%)
Brightness (+/-)
Start
Sensitivity
Memory
Apply
Program Mode
Save Setting
One Key Apply
Auto
Hold time
Stand-by dimming level
Daylight threshold
Stand-by period
In this area, movement will be detected and able to trigger the sensor.
100% detection area is also known as the strongest sensitvity.
Setting the light permanent ON or OFF without motion mode
Key Function
Switch to sensor mode and restore the latest sensor setting

FCC Warning
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant
to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one
or more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
—Consult the dealer or an experienced radio/TV technician for help.
Note: The Grantee is not responsible for any changes or modifications not expressly approved by the party
responsible for compliance. such modifications could void the user's authority to operate the equipment.
The device has been evaluated to meet general RF exposure requirement.
To maintain compliance with FCC's RF exposure guidelines, the distance must be at least 20 cm
between the radiator and your body, and fully supported by the operating and installation
Table of contents
Other Mosentek Security Sensor manuals
Popular Security Sensor manuals by other brands

Markes International
Markes International C-HLD Instructions for use

MS Sedco
MS Sedco DHR3 installation instructions

Spectronics Corporation
Spectronics Corporation Pro Alert TP-9360 operating manual

Fast
Fast Aqua M300 D operating instructions

PRO Intellect Technology
PRO Intellect Technology MONIRON DEC EUR user manual

Bentel Security
Bentel Security BL151 manual