DESCRIPTION – 1000W
7ELECTFRFLSH017
1000W GLOWASH
41.67A
The function of this unit is to turn on a set of lights at or below its capabilities. The output
wiring color code is printed on power supply. The incoming power source is from a
dedicated 15A circuit. With 110VAC hot, a neutral and a ground. When powering DC
lights from a MCWW product located on the back next to the enclosure is a schematic
diagram for that product.
Output voltage is polarity sensitive. Positive of light must be connected to 24VDC
(+COMMON+) in panel! Negative(s) of lights must be connected to either ‘Red’, ‘Green’
or ‘Blue’ terminals in the panel.
Red (Zone 1): 0VDC to Red Light
Green (Zone 1): 0VDC to Green
Light
Blue (Zone 1): 0VDC to Blue Light
+Common+: 24VDC
Red (Zone 2): 0VDC to Red Light
Green (Zone 2): 0VDC to Green
Light
Blue (Zone 2): 0VDC to Blue Light
+Common+: 24VDC
A2: CW Controller Output Neutral
(-24-120 AC/DC)
A1: CW Controller Output Hot
(+24-120 AC/DC)
Signal
OUT
Signal
IN
12345678 12345678
Pin1:Data+
Pin2:Data-
Pin7:GND
Pin8:GND
POWEROUTPUT
V+
CH1
(red)
CH2
(green)
CH3
(blue)
powersignal
VOLTAGE
12-24VDC
MAX
CURRENT
3*10A (30A)
8ELECLEDCTLR005
Signal
OUT
Signal
IN
12345678 12345678
Pin1:Data+
Pin2:Data-
Pin7:GND
Pin8:GND
POWEROUTPUT
V+
CH1
(red)
CH2
(green)
CH3
(blue)
powersignal
VOLTAGE
12-24VDC
MAX
CURRENT
3*10A (30A)
8ELECLEDCTLR005
8ELECTNLBLK0021
32A D
UL489
8ELECBRKR1P0015
8ELECTNLBLK0009
CB1
24VDC +
RED
BLUE
GREEN
32A D
UL1077
CB2
2A D
UL1077
CB3
8ELECTNLBLK0009
8ELECTNLBLK0009
8ELECTNLBLK0 009
24VDC +
RED
BLUE
GREEN
32A D
UL1077
CB2
N
L1
8ELECTNLBLK0021
8ELECTNLBLK0021
8ELECTNLBLK0021
8ELECTNLBLK0021
8ELECTNLBLK0021
8ELECTNLBLK0009
8ELECTNLBLK0009
141211
A2 A1
A1
A2 11
1214
ELKO
8ELECTNLBLK0009
8ELECTNLBLK0009
8ELECTNLBLK0009
120V MAIN DISCONNECT
8ELECWIRLBL0006
IN 115/230VAC-17.5/10A
OUT 1000W-24VDC
8ELECPWRTFR0024
TEST
DATE
WASH WORKS
TESTED
DATE INITIALS
8DCALELCWRN0001
LOSS OF PROTECTION - Risk of Fire or Electr ic Shock
To maintain overcurrent, short-circuit and ground-fault protection:
Follow instructions for selecting overload and short-circuit protection.
If overload or fault current interruption occurs:
Check all circuits and determine cause of interruption.
Examine all current-carrying components, and replace if damaged.
If burnout occurs, replace the complete overload relay.
Failure to follow these instructions can result in serious injury.
24VDC +
RED
BLUE
GREEN
24VDC - CBX
24VDC - CBX
RED
BLACK
GREEN
WHITE
CONNECT UP TO THREE WHIPS ON ONE ZONE
8ELECRLYSPS0002
0 1
6
4
A1 A2
24VDC
30A
8ELECRLYSPS0002
01
6
4
A1 A2
24VDC
30A
RED
GREEN
BLUE
+COMMON+
RED
GREEN
BLUE
+COMMON+
PS1
A1 A2
READY
SIGNAL
12-240V
AC/DC