Motorline professional TEC100 Instruction Manual

V3.0
REV. 01/2019
TEC100 EN
USER/INSTALLER MANUAL

A B
1B
2B
3A
4A
4B
9B
9A
6A
6B
6B
7A
10
2B
ENEN
STANDARDS TO FOLLOW
PRODUCT PROFILE
PRODUCT INSTALLATION
QUICK REFERENCE PROGRAMMING GUIDE
USER SETTINGS
LEAD WIRE DESCRIPTION
SOUNDS AND LIGHTS
DOOR SETTINGS
RESET TO FACTORY DEFAULT
ANTI TAMPER ALARM
ACCESS CONTROL THROUGH CODE (MCA)
CABLING DIAGRAM
. SAFETY INSTRUCTIONS
. PRODUCT
. INSTALLATION
. PROGRAMMING
. DETAILED PROGRAMMING GUIDE
. CABLING
. ACOUSTO-OPTIC INSTRUCTIONS
. CONTENT . SAFETY INSTRUCTIONS
INDEX STANDARDS TO FOLLOW
TECHNICAL PARAMETERS
ATTENTION:
This product is certified in accordance with European Community
(EC) safety standards.
This product complies with Directive 2011/65/EU of the European
Parliament and of the Council, of 8 June 2011, on the restriction of
the use of certain hazardous substances in electrical and electronic
equipment.
(Applicable in countries with recycling systems).
This marking on the product or literature indicates that the product
andelectronicaccessories(eg.Charger,USBcable,electronicmaterial,
controls, etc.) should not be disposed of as other household waste at
the end of its useful life. To avoid possible harm to the environment
or human health resulting from the uncontrolled disposal of waste,
separate these items from other types of waste and recycle them
responsibly to promote the sustainable reuse of material resources.
Home users should contact the dealer where they purchased this
product or the National Environment Agency for details on where and
how they can take these items for environmentally safe recycling.
Business users should contact their vendor and check the terms and
conditions of the purchase agreement. This product and its electronic
accessories should not be mixed with other commercial waste.
This marking indicates that the product and electronic accessories
(eg. charger, USB cable, electronic material, controls, etc.) are
susceptible to electric shock by direct or indirect contact with
electricity. Be cautious when handling the product and observe all
safety procedures in this manual.

A B
ENEN
. SAFETY INSTRUCTIONS . PRODUCT
STANDARDS TO FOLLOW PRODUCT PROFILE
TECHNICAL PARAMETERS
Theunit is single door multifunction standaloneaccesscontrollerora Wiegand output keypad
or card reader. It is suitable for mounting either indoor or outdoor in harsh environments. It
is housed in a strong, sturdy and vandal proof Zinc Alloy electroplated case which is available
in either a bright silver or matt silver finish. The electronics are fully potted so the unit is
waterproof and conforms to IP68. This unit supports up to 2000 users in either a Card, 4 digit
PIN, or a Card + PIN option. The inbuilt card reader supports 125KHZ EM cards,13.56MHz Mifare
cards. The unit has many extra features including lock output current short circuit protection,
Wiegand output , and a backlit keypad. These features make the unit an ideal choice for
door access not only for small shops and domestic households but also for commercial and
industrial applications such as factories, warehouses, laboratories, banks and prisons.
• Waterproof, conforms to IP68
• Strong Zinc Alloy Electroplated anti-
vandal case
• Full programming from the keypad
• 2000 uses, supports Card, PIN, Card + PIN
• Can be used as a stand alone keypad
• Backlight keys
• Wiegand 26 input for connection to
external reader
• Wiegand 26 output for connection to a
controller
• Adjustable Door Output time, Alarm time,
Door Open time
• Very low power consumption (30mA)
• Fast operating speed, <20ms with 2000
users
• Lock output current short circuit
protection
• Easy to install and program
• Built in light dependent resistor (LDR) for
anti tamper
• Built in buzzer
• Red, Yellow and Green LEDS display the
working status
• Work Voltage ac&dc 9-28V
• Static Current <30mA
• Reading Range 3-8cm
• Capacity 2000 users
• Ambient Temperature -25~55C
• Ambient Humidity 10% ~ 90%
• Electricity lock output <3A
• Alarm output <20A
• Output short circuit protection time <100S
• Open time 0 ~ 99 seconds (adjustable)
• It is important for your safety that these instructions are followed.
• Keep these instructions in a safe place for future reference.
• The ELECTROCELOS S.A. is not responsible for the improper use of the product,
or other use than that for which it was designed.
• The ELECTROCELOS S.A. is not responsible if safety standards were not taken
into account when installing the equipment, or for any deformation that may
occur.
• The ELECTROCELOS S.A. is not responsible for insecurity and malfunction of the
product when used with components that were not sold by the them.
• This product was designed and manufactured strictly for the use indicated in
this manual.
• Any other use not expressly indicated may damage the product and/or can
cause physical and property damages, and will void the warranty.
• Do not make any changes to the automation components and/or their
accessories.
• The customer shall not, under any circumstances, attempt to repair or tune the
automatism. Must call qualified technician only.
•Theinstallermusthavecertifiedprofessionalknowledgeatthelevelofelectronic.
He should also be able to perform electrical connections in compliance with all
applicable regulations.
• The installer should inform the customer how to handle the product in an
emergency and provide him the manual.
• This device can be used by children 8 year old or older and persons whose
physical, sensory or mental capacities are reduced, or by persons without
experience or knowledge if they have received supervision or instructions on
the use of the device in a safe manner and understood the hazards involved.
Children should not play with the device. Cleaning and maintenance by the user
must not be carried out by unsupervised children.
• Automatism powered by very low safety voltage, with electronic board/control
board/control unit.
• Before installing, the installer must verify that the temperature range indicated
on the automatism is appropriate to the location of the installation.
• In order to protect the electrical cables against mechanical stress, you should
use conduit for the electrical wires, essentially on the power cable.

A B
88mm 27mm
122mm
ENEN
. INSTALLATION
PRODUCT INSTALLATION PRODUCT INSTALLATION
. INSTALLATION
1 • Apply the drilling diagram (B) to the
desired installation place.
3 • Using the hex key (C), loosen the screw in
totality and remove the back cover.
5 • Insert the cable into the hole.2 • Make the holes:
F - TEC100 fixing holes;
G - hole to pass the cable.
4 • Insert the bushings, place the back cover
and tighten totally the screws.
BUSHING
F
G
F
SCREW
6 • Attach the body of the TEC100 to the
back cover, insert the screw and tighten
completely.
A • TEC100
B • Drilling diagram
C • Hex key
D • Screws
E • Bushings
Caption

A B
ENEN
To enter the programming mode 999999 is the default factory master code
To exit from the programming
mode
Note that to undertake the following programming the master user must be logged in
To change the master code The master code can be 6 to 8 digits long
Setting the working mode:
Set valid card only users
Set valid card and PIN users
Set valid card or PIN users
Entry is by card only
Entry is by card and PIN together
Entry is by either card or PIN (default)
To add a user in either card or PIN mode, i.e. in the mode. (Default setting)
To add a PIN user
The ID number is any number between 1 & 2000. The
PIN is any four digits between 0000 & 9999 with the
exception of 1234 which is reserved. Users can be
added continuously without exiting programming
mode as follows:
To delete a PIN user
Users can be deleted continuously without exiting
programming mode
To change the PIN of a PIN user
(This step must be done out of
programming mode)
. PROGRAMMING
QUICK REFERENCE PROGRAMMING GUIDE
. DETAILED PROGRAMMING GUIDE
USER SETTINGS
To enter the programming mode 999999 is the default factory master code
To exit from the programming
mode
Note that to undertake the following programming the master user must be logged in
To change the master code The master code can be 6 to 8 digits
To add a PIN user
The ID number is any number between 1 & 2000. The
PIN is any four digits between 0000 & 9999 with the
exception of 1234 which is reserved. Users can be
added continuously without exiting programming mode
To add a card user Cards can be added continuously without exiting
programming mode
To delete a PIN or a card user
Users can be deleted continuously without exiting
programming mode
To unlock the door for a PIN user Enter the then press
To unlock the door for a card user Present the card
Master code
*#Master code
*#
Read card
*#
User ID number
2
#03
#13
#23
#23
#
Read card
2#
New code New code
0# #
User ID number PIN
1# #
User ID number
2#
**
Use ID number
1 # PIN #
User ID no 1 User ID no 2
1 # PIN # #
PIN #
PIN #
ID number
* # Old PIN #
New PIN New PIN
# #
for PIN user or
for a card user
New code
0##
New code

A B
ENEN
To add a card user (Method 1)
This is the fastest way to enter
cards, user ID number auto
generation Cards can be added continuously without exiting
programming mode
To add a card user (Method 2)
This is the alternative way to
enter cards using User ID
Allocation. In this method a User
ID is allocated to a card. Only
one user ID can be allocated to a
single card User can be added continuously without exiting
programming mode
To add a card user (Method 3)
Card number is the last 8
digits printed on the back of
the card,user ID number auto
generation User can be added continuously without exiting
programming mode
To add a card user (Method 4)
In this method a User ID is
allocated to a card number. Only
one user ID can be allocated to
the card number User can be added continuously without exiting
programming mode
To delete a card user by card.
Note users can be deleted
continuously without exiting
programming mode
To delete a card user by user ID.
This option can be used when a
user has lost their card
To delete a card user by card
number.
This option can be used when the
user want to make the change but
the card has lost Note users can be deleted continuously without
exiting programming mode
To add a card and PIN user in card and PIN mode ( )
To Add a card and Pin user
(The PIN is any four digits
between 0000 & 9999 with
the exception of 1234 which is
reserved.)
Add the card as for a card user
Press to exit from the programming mode
Then allocate the card a PIN as follows:
To change a PIN in card and PIN
mode (Method 1) Note that this is
done outside programming mode
so the user can undertake this
themselves
To change a PIN in card and PIN
mode (Method 2) Note that this is
done outside programming mode
so the user can undertake this
themselves
To delete a Card and PIN user just
delete the card
To add a card user in card mode ( )
To Add and Delete a card user The operating is the same as adding and deleting a
card user in
To delete All users
To delete ALL users. Note that this
is a dangerous option so use with
care
To unlock the door
For a PIN user Enter the then press
For a card User
For a card and PIN user then enter
Read card
1#
1
Card number
1#
Read Card
2#
User ID
2#
User ID
2#
0000
2#
Card number
2#
PIN
PIN
Read card #
ID number
1#
Card number #
ID number
1#
#13
#03
#23
Read card
*# # #
1234 PIN PIN
Read card
Read card
Read card
*#
Old PIN New PIN
# #
New PIN
ID number
*#
Old PIN New PIN
# #
New PIN
*
#
USER SETTINGS USER SETTINGS
. DETAILED PROGRAMMING GUIDE . DETAILED PROGRAMMING GUIDE

A B
ENEN
Relay Output Delay Time
To set door relay strike time 0-99 is to set the door relay time 0-99 seconds
Door Open Detection
Door Open Too Long (DOTL) warning. When used with an optional magnetic contact or
built-in magnetic contact of the lock, if the door is opened normally, but not closed after
1 minute, the inside buzzer will beep automatically to remind people to close the door
and continue for 1 minute before switching off automatically.
Door Forced Open warning. When used with an optional magnetic contact or built-in
magnetic contact of the lock, if the door is forced open, or if the door is opened after 20
seconds ,the inside buzzer and alarm output will both operate. The Alarm Output time is
adjustable between 0-3 minutes with the default being 1 minute.
To disable door open detection.
(Factory default)
To enable door open detection
Alarm output time
To set the alarm output time
(0-3 minutes) Factory default is 1
minute
Keypad Lockout & Alarm Output options. If there are 10 invalid cards or 10 incorrect
PIN numbers in a 10 minute period either the keypad will lockout for 10 minutes or both
the alarm and the inside buzzer will operate for 10 minutes, depending on the option
selected below.
Normal status: No keypad lockout
or alarm (factory default) (Factory default setting)
Keypad Lockout
Alarm and inside buzzer operate
To remove the alarm
To reset the Door Forced Open
warning or
To reset the Door Open Too Long
warning Close the door or
1• Disconnect power from the unit
2• Press and hold # key whilst powering the unit back up
3• On hearing two “Di” release # key, system is now back factory settings
Please note only installer data is restored, user data will not be affected
The unit uses a LDR (light dependent resistor) as an anti tamper alarm. If the keypad is
removed from the cover then the tamper alarm will operate.
Master Code #
Read valid card
Master Code #
Read valid card
#06
#16
#07
#17
#27
#0~35
DOOR SETTINGS DOOR SETTINGS
RESET TO FACTORY DEFAULT
ANTI TAMPER ALARM
. DETAILED PROGRAMMING GUIDE . DETAILED PROGRAMMING GUIDE
or
value #
master code # 4
**

A B
ENEN
ACCESS CONTROL THROUGH CODE (MCA)
. GUIA DE PROGRAMAÇÃO AVANÇADA .
ACCESS CONTROL THROUGH CODE (MCA)
. DETAILED PROGRAMMING GUIDE
1 • Access "Operation" and select the "tools"
tab.
2 • Press "extended function".
3 • Enter the password 5678.
5 - Press "ok".
4 • Go to "Configuration" and select "Activate access keypad".
When to Use
When there is an MCA connected with a
TEC100 to operate only with code, we need
to follow the following steps to register
inputs and outputs.
NOTE: For the changes to take effect, you must restart the device.

A B
ENEN
ACCESS CONTROL THROUGH CODE (MCA)
. DETAILED PROGRAMMING GUIDE
ACCESS CONTROL THROUGH CODE (MCA)
. DETAILED PROGRAMMING GUIDE
9 • Select the user you want to give privilege and click on "Access Privilege".
10 • The box to add / remove doors to the user appears.
11 • To finish this edition press "Confirm and upload".
12 • Now access the "Pwd MGT" tab to set the type of access you want (PIN-Card).
6 • Access "Configuration" and select the "Personnel" tab.
7 • Press "Edit" or double-click on the person.
8 • Fill in the requested data and press "ok". Later, to identify yourself, you will
have to enter the Card Number and PIN, eg * 14 # 123456.

A B
ENEN
. ACOUSTO-OPTIC INSTRUCTIONS
OPERATION STATE RED LIGHT GREEN LIGHT BUZZER NOTE
Standby Slow flashing Off
Buttons Di
Success Off On Di—
Failure Di Di Di
Into programming On Off Di— Indicator is
orange
Set condition On On
Exit programming Slow flash Off Di—
Unlock Off On Di—
Alarm Fast flashing Off Alarm sound
. CABLING
LEAD WIRE DESCRIPTIONSOUNDS AND LIGHTS
Line
sequence Marks Color Function description
1BELL_A Pink Doorbell button one end
2BELL_B Light pink The doorbell button to the other end
3D Green WG output line D
4D White WG output line D
ALARM Grey Alarm negative (alarm positive
connected v
OPEN Yellow Exit button one end (Exit button the other end
connected GND)
D_IN Brown Magnetic switch one end (magnetic switch
another end connected GND)
AC&DC Red Power supply -V input (DC input)
AC&DC Black Power supply -V input (DC input -)
NO Blue Relay NO
COM Purple Relay common
NC Orange Relay NC

A
-
-
+
+
EN
. CABLING
CABLING DIAGRAM
Ordinary power supply cabling diagram
Metalpassword access controller
Metalpassword access controller
BELL_A Pink Bell
- Alarm +
Exit button
Door
magnetic
switch
Positive
electronic
lock
Negative
electronic
lock
Power
- 12V +
Light
Pink
Green
White
Gray
Yellow
Brown
Red
Black
Blue
Purple
Orange
Shiedlding
layers
BELL_B
D0 D0
D1
Access control
+12V
GND
D1
ALARM
OPEN
D_IN
AC&DC+
AC&DC-
NO
COM
NC
GND
Access control power supply cabling diagram Operating as a wiegand output reader
In this mode the unit supports a wiegand 26 bit output
so the wiegand data lines can be connected to any
controller supports 26 bit input.
BELL_A BELL_A
D0
NO COM NC 12V GND PUSH
D1
+12V
Access control
12Vdc/3A
GND
Pink
Pink
Pink
Light
Pink
Green Green
White White
Gray Gray
Yellow Yellow
Brown Brown
Red Red
Black Black
Blue Blue
Purple Purple
Orange Orange
Shiedlding
layers
BELL_B BELL_B
D0 D0
D1 D1
ALARM ALARM
OPEN OPEN D0
D_IN D_IN D1
AC&DC+ +12V 12V
AC&DC- GND GND
NO NO
COM COM
NC NC
GND
Connect
Bell
- Alarm +
Exit button
Negative
electronic
lock
Positive
electronic
lock
Door
magnetic
switch
Other manuals for TEC100
1
Table of contents
Other Motorline professional Keypad manuals
Popular Keypad manuals by other brands

Simons Voss Technologies
Simons Voss Technologies 3068 manual

Videx
Videx VX8902F instruction manual

SDC
SDC EntryCheck 923P installation instructions

APO
APO DK-9350 Programming & installation manual

TEMPerature Products
TEMPerature Products FreezeAlarm Dialer CNPREC001 Installation and operation manual

DELTA DORE
DELTA DORE CLE 8000 TYXAL+ installation guide