Motorline professional MD150 Operation and installation manual

RESET
MODE
v1.0
REV. 04/2023
MD150MD150 EN
INSTALLER AND USER’S MANUAL

1A 1B
1B
4A
4B
6A
7A
6B
5A
7A
7B
8A
7B
8A
ENEN
00. CONTENT
INDEX
TECHNICAL CHARACTERISTICS
PRECAUTIONS TO HAVE
COMPONENT CONNECTIONS
MODE OF OPERATION CHANNEL AND CHANNEL RELAY
DEVICE RESET
FREQUENCY ADJUSTMENT
OPERATION AND INDICATION OF STATUS
DEVICE INSTALLATION
SENSITIVITY ADJUSTMENT
AUTOMATIC INCREASE IN SENSITIVITY
DIRECTION OF THE CHANNELS
. SAFETY INSTRUCTIONS
. MAGNETIC DETECTOR
. PRE INSTALLATION
. CONNECTION SCHEME
. PROGRAMMING
. INSTALLATION
ATTENTION:
01. SAFETY INSTRUCTIONS
This product is certified in accordance with European
Community (EC) safety standards.
This product complies with Directive 2011/65/EU of the
European Parliament and of the Council, of 8 June 2011, on
the restriction of the use of certain hazardous substances in
electrical and electronic equipment.
(Applicable in countries with recycling systems).
This marking on the product or literature indicates that the
product and electronic accessories (eg. Charger, USB cable,
electronic material, controls, etc.) should not be disposed
of as other household waste at the end of its useful life. To
avoid possible harm to the environment or human health
resulting from the uncontrolled disposal of waste, separate
these items from other types of waste and recycle them
responsibly to promote the sustainable reuse of material
resources. Home users should contact the dealer where they
purchased this product or the National Environment Agency
for details on where and how they can take these items
for environmentally safe recycling. Business users should
contact their vendor and check the terms and conditions
of the purchase agreement. This product and its electronic
accessories should not be mixed with other commercial
waste.
This marking indicates that the product and electronic
accessories (eg. charger, USB cable, electronic material,
controls, etc.) are susceptible to electric shock by direct or
indirect contact with electricity. Be cautious when handling
theproductandobserveallsafetyproceduresinthismanual.

2A EN
GENERAL WARNINGS
•This manual contains very important safety and usage information.
very important. Read all instructions carefully before beginning the
installation/usage procedures and keep this manual in a safe place
that it can be consulted whenever necessary.
•This product is intended for use only as described in this manual. Any
other enforcement or operation that is not mentioned is expressly
prohibited, as it may damage the product and put people at risk
causing serious injuries.
•Thismanualisintended firstly for specialized technicians, and does not
invalidate the user’s responsibility to read the “User Norms” section in
order to ensure the correct functioning of the product.
•The installation and repair of this product may be done by qualified
and specialized technicians, to assure every procedure are carried
out in accordance with applicable rules and norms. Nonprofessional
and inexperienced users are expressly prohibited of taking any action,
unless explicitly requested by specialized technicians to do so.
•Installations must be frequently inspected for unbalance and the
wear signals of the cables, springs, hinges, wheels, supports and other
mechanical assembly parts.
•Do not use the product if it is necessary repair or adjustment is
required.
•When performing maintenance, cleaning and replacement of parts,
the product must be disconnected from power supply. Also including
any operation that requires opening the product cover.
•The use, cleaning and maintenance of this product may be carried
out by any persons aged eight years old and over and persons whose
physical,sensorialormentalcapacitiesarelower,orbypersonswithout
any knowledge of the product, provided that these are supervision
and instructions given by persons with experienced in terms of usage
of the product in a safe manner and who understands the risks and
dangers involved.
•Children shouldn’t play with the product or opening devices to avoid
the motorized door or gate from being triggered involuntarily.
WARNINGS FOR TECHNICIANS
•Before beginning the installation procedures, make sure that you have
all the devices and materials necessary to complete the installation
of the product.
•You should note your Protection Index (IP) and operating temperature
to ensure that is suitable for the installation site.
•Provide the manual of the product to the user and let them know how
to handle it in an emergency.
•If the automatism is installed on a gate with a pedestrian door, a door
locking mechanism must be installed while the gate is in motion.
•Do not install the product “upside down” or supported by elements do
not support its weight. If necessary, add brackets at strategic points
to ensure the safety of the automatism.
•Do not install the product in explosive site.
•Safety devices must protect the possible crushing, cutting, transport
and danger areas of the motorized door or gate.
•Verify that the elements to be automated (gates, door, windows,
blinds, etc.) are in perfect function, aligned and level. Also verify if the
necessary mechanical stops are in the appropriate places.
•The centralmustbe installedon a safeplace of any fluid (rain, moisture,
etc.), dust and pests.
•You must route the various electrical cables through protective tubes,
to protect them against mechanical exertions, essentially on the
power supply cable. Please note that all the cables must enter the
central from the bottom.
•If the automatism is to be installed at a height of more than 2,5m from
the ground or other level of access, the minimum safety and health
requirements for the use of work equipment workers at the work of
Directive 2009/104/CE of European Parliament and of the Council of 16
01. SAFETY INSTRUCTIONS

3A EN
September 2009.
•Attach the permanent label for the manual release as close as possible
to the release mechanism.
•Disconnect means, such as a switch or circuit breaker on the electrical
panel, must be provided on the product’s fixed power supply leads in
accordance with the installation rules.
•If the product to be installed requires power supply of 230Vac or
110Vac, ensure that connection is to an electrical panel with ground
connection.
•The product is only powered by low voltage satefy with central (only
at 24V motors)
WARNINGS FOR USERS
•Keep this manual in a safe place to be consulted whenever necessary.
•If the product has contact with fluids without being prepared, it must
immediately disconnect from the power supply to avoid short circuits,
and consult a specialized technician.
•Ensure that technician has provided you the product manual and
informed you how to handle the product in an emergency.
•Ifthesystemrequiresanyrepairormodification,unlocktheautomatism,
turn off the power and do not use it until all safety conditions have
been met.
•In the event of tripping of circuits breakers of fuse failure, locate
the malfunction and solve it before resetting the circuit breaker or
replacing the fuse. If the malfunction is not repairable by consult this
manual, contact a technician.
•Keep the operation area of the motorized gate free while the gate in in
motion, and do not create strength to the gate movement.
•Do not perform any operation on mechanical elements or hinges if the
product is in motion.
RESPONSABILITY
•Supplier disclaims any liability if:
•Product failure or deformation result from improper installation
use or maintenance!
•Safety norms are not followed in the installation, use and
maintenance of the product.
•Instructions in this manual are not followed.
•Damaged is caused by unauthorized modifications
•In these cases, the warranty is voided.
MOTORLINE ELECTROCELOS SA.
Travessa do Sobreiro, nº29
4755-474 Rio Côvo (Santa Eugénia)
Barcelos, Portugal
01. SAFETY INSTRUCTIONS
SYMBOLS LEGEND:
• Important safety
notices
• Useful information
• Programming
information
• Dippers
programming
• Buttons
information

4A 4B
42 78
105
78
ENEN
. MAGNETIC DETECTOR . PRE INSTALLATION
TECHNICAL CHARACTERISTICS PRECAUTIONS TO HAVE
MD is a vehicle magnetic detector that detects the presence of large metal objects (cars, trucks,
wagons) even when the vehicle is not moving.
• The circuit and power cable must be isolated copper wire with a minimum cross section of .mm.
• The wires (rigid or flexible) must be 1.5mm.
• The circuit must be square or rectangular with a minimum distance of one meter between the two
opposite sides.
• Usually three turns of wire are used in the circuit, except in particular conditions of steel mesh in the
ground, where five turns of wire must be made in the circuit.
• To avoid detector malfunction due to interference, the circuits must be at least 1 meter apart and
operating at different frequencies.
The dimensions of MD are the following:
Wire splicing is not advised. In any case, any splices should be welded and waterproofed
to prevent detector malfunction. Power cables subject to electrical interference must be
shielded cable grounded at the detector.
Please pay attention to the supply voltage of the equipment.
Any wrong connection will damage the product.
Large circuits with a circumference of more than 8 meters should have two turns, while those
with a circumference of less than 6 meters should have four turns. In the case of two circuits
next to each other, to avoid interference, it is recommended to install one circuit with three
turns and another with four turns.
MD
• Power supply Vac
• Maximum distance between Loop and MD meters
• Sensitivity adjustment adjustable levels
• Presence mode Limited presence / Permanent presence
• Indicator Power Indicator: Red LED
Status indicator: Green LED
• Internal protection Transformer isolation, voltage regulation tube,
voltage dependent resistance
• Working temperature -°C °C
• Frequency or Mhz
• Outputs NO outputs (contact max A Vac) or
NO output and NC output

5A
2000-3000
1000
1000
≥800
≥500
2m-3m
2m
1m
∅4mm
30-50mm
3
1
2
3
1
2
3
EN
. INSTALLATION
To avoid electromagnetic interference, pull the loop wires
from the power wires.
DRILL THE FLOOR
Punch the floor using a suitable tool.
(see detail A).
Then make 45 ° incisions to prevent damage to the wire.
PUT THE WIRE
Make the necessary turns of wire in the floor cutout.
Twist the wire segment that forms the power cable.
Fill the crack with epoxy resin or bitumen (see detail B).
INSTALL MD
Detach the connector base from the MD150 and install on the desired
surface.
Make the connections according to the diagram on the next page.
Put the MD150 back on the connector base.
DETAIL BDETAIL A
Epoxy
The intertwined wires between the Loop and the MD
must not exceed m in length.
Wire
Wire
Wire
The 2000mm measurement for the width of the floor cutout is just a reference.
This measure will always depend on the width of the passageway.
Ground type Turns of wire
Normal
With steel mesh
DEVICE INSTALLATION

6A 6B
9 8 7 5 3 4
10
10
11 6 1 2
L2
L1
ENEN
. CONNECTION SCHEME
COMPONENT CONNECTIONS
. PROGRAMMING
Numbers Description
Input Vac
Channel output (NO)
Channel Output (Common)
Channel output (NO)
Channel Output (Common)
Loop Channel
8
Loop Channel
Channel output (NC)
L2
L1
OPERATION AND INDICATION OF STATUS
DEVICE CALIBRATION
BEHAVIOR OF THE LEDs
State Behavior
Device connected The LED POWER (red) stays on
Calibration process Green LEDs stay on
Vehicle passage The LED corresponding to the activated loop lights up during the passage
Mistakes Behavior
Loop not detected in
calibration
The green LEDs blink intermittently
The loop is not done
according to the given
range values
When connecting the device to power, the calibration will be done automatically.
The calibration process takes about seconds.
Once the calibration process is complete the green LEDs will turn off.
LED POWER (Red) LED LOOP (Green)
LED LOOP (Green)
During the calibration process, the two green LEDs on the panel remain ON.
No vehicle should pass through the loop zone during the calibration process.
Power Supply
Loop
Loop

7A 7B
ON
1
2
3 4
5
6
7
8
9
10
ON
1
2
3 4
5
6
7
8
9
10
ON
1
2
3 4
5
6
7
8
9
10
ON
1
2
3
4
5
6
7
8
9
10
ON
1
2
3
4
5
6
7
8
9
10
ON
1
2
3
4
56
7
8
9
10
ON
1
2
3
4
56
7
8
9
10
ON
1
2
3
4
56
7
8
9
10
ON
1
2
3
4
56
7
8
9
10
ON
1
2
3
4
5
6
7
8
9
10
ON
1
2
3
4
5
6
7
8
9
10
ON
1
2
3 4
5
6
7
8
9
10
ON
1
2
3
4
5
6
7
8
9
10
ON
1
2
3
4
5
6
7
8
9
10
ON
1
2
3
4
5
6
7
8
9
10
ON
1
2
3
4
5
6
7
8
9
10
ON
1
2
3
4
5
6
7
8
9
10
ON
1
2
3
4
5
6
7
8
9
10
ENEN
. PROGRAMMING
FREQUENCY ADJUSTMENT
. PROGRAMMING
AUTOMATIC INCREASE IN SENSITIVITY
MODE OF OPERATION CHANNEL AND CHANNEL RELAY
SENSITIVITY ADJUSTMENT
Frequency Channel Frequency Channel
Dip switch Dip switch
Low High Low High
ON OFF ON OFF
Sensitivity Channel Sensitivity Channel
Dip switch and Dip switch and
ON OFF ON OFF
The adjustment of the frequency of channels and is done on Dip switch and Dip switch
respectively which are located on the front panel of Dippers.
This depends on the geometric shape, size and number of turns of the loop.
The adjustment of the sensitivity of channel is done using Dip switch and . Dip switch and
regulate the sensitivity of channel .
Several factors influence the sensitivity: length of the loop, number of turns in the loop, length of
connection cable and the presence of metals under the loop.
To perform a test manoeuvre, you must set the Sensitivity to the lowest level. After carrying out
the test, if the vehicle is not detected, increase the Sensitivity by one level.
Repeat the procedure until vehicle detection works correctly.
The automatic increase in sensitivity increases the sensitivity level to the maximum value.
This level is maintained the entire time the car is on the loop. When the loop stops detecting the vehicle,
the sensitivity level returns to the pre-selected value.
You can define if Channels and both work in the same direction of passage, or if they work
independently with each channel corresponding to a direction of passage.
For this, configure Dippers and
Automatic Sensitivity Increase
Dip switch
Active Disable
ON OFF
Input settings Output settings
Dip switch Dip switch
Limited Presence Permanent Presence Limited Output Permanent Exit
The Channel relay
(outputs and ) has a
pass timeout of ms.
The Channel relay (outputs
and ) and the Channel
relay (outputs and ) have
a timeout of ms.
When the vehicle leaves,
the Channel relay
(outputs and ) has an
output timeout of ms.
There is no timer for exit
mode.
ON OFF ON OFF

8A
ON
1
2
3
4
5
6
7
8
9
10
ON
1
2
3
4
5
6
7
8
9
10
RESET
MODE
RESET
MODE
EN
DIRECTION OF THE CHANNELS
You can define whether the two channels work individually (Single) for each direction or whether they
work simultaneously (Double) in the same direction.
By pressing the reset button, the device will automatically switch to a vehicle-free mode.
Direction of the channels
Dip switch
Individual Double
ON OFF
DEVICE RESET
Make sure that no vehicles pass during the reset process.
. PROGRAMMING
Table of contents
Other Motorline professional Security Sensor manuals
Popular Security Sensor manuals by other brands

TELEDYNE OLDHAM SIMTRONICS
TELEDYNE OLDHAM SIMTRONICS Everywhereyoulook MultiFlame DF-TV7 operating manual

Tatsuta Electric Wire & Cable
Tatsuta Electric Wire & Cable AD-AS-1LCM-A Operation manual

SKYLOTEC
SKYLOTEC G-1131-XS/M Instructions for use

Hihome
Hihome Zigbee WZB-PIR quick start

BW Technologies
BW Technologies GasAlertMicro 3 user manual

Alarmtech
Alarmtech MC 140 instruction manual