manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. mr. steam
  6. •
  7. Controllers
  8. •
  9. mr. steam iSteamX Instruction manual

mr. steam iSteamX Instruction manual

Other mr. steam Controllers manuals

mr. steam AirButler User manual

mr. steam

mr. steam AirButler User manual

mr. steam iTEMPO Instruction manual

mr. steam

mr. steam iTEMPO Instruction manual

Popular Controllers manuals by other brands

Sunricher SR-ZV9003T3-RGBW-US Installation

Sunricher

Sunricher SR-ZV9003T3-RGBW-US Installation

Ksenia intro Installation and configuration manual

Ksenia

Ksenia intro Installation and configuration manual

Inovance CAN200 Series manual

Inovance

Inovance CAN200 Series manual

Gauzy LC6 FLEX Controller Installation and operation guide

Gauzy

Gauzy LC6 FLEX Controller Installation and operation guide

Viking SLP-1 Technical practice

Viking

Viking SLP-1 Technical practice

CKD KBX-30E-U Series instruction manual

CKD

CKD KBX-30E-U Series instruction manual

Sharp Energy Sun Flux User manual & installation guide

Sharp Energy

Sharp Energy Sun Flux User manual & installation guide

Yamaha RCX40 user manual

Yamaha

Yamaha RCX40 user manual

AB Quality PowerFlex 400 Frames D-H Service bulletin

AB Quality

AB Quality PowerFlex 400 Frames D-H Service bulletin

Yamaha MJC8 owner's manual

Yamaha

Yamaha MJC8 owner's manual

AL-KO ATC operating instructions

AL-KO

AL-KO ATC operating instructions

Savant SmartControl 2 Deployment guide

Savant

Savant SmartControl 2 Deployment guide

GameSir T3S user manual

GameSir

GameSir T3S user manual

Kostal inveor operating manual

Kostal

Kostal inveor operating manual

Emerson Yarway 20-55 Operating and safety instructions

Emerson

Emerson Yarway 20-55 Operating and safety instructions

CoCo ACM-LV24 Quick installation guide

CoCo

CoCo ACM-LV24 Quick installation guide

Brooks SLA5810/20 Installation and operation manual

Brooks

Brooks SLA5810/20 Installation and operation manual

SIGMA TEK SR 011 Technical manual

SIGMA TEK

SIGMA TEK SR 011 Technical manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

mr
.steam®Feel Good Inc.®
Installation, Operation and Maintenance Manual
Linear Steam Head
Residential Model:
104480
____________________
MP
_
O
_
RT
_
AN
_
T:_
Le
_
ave
_
th
_
is
_
ma
_
teri
_
al
_
wit
_
h
t
_
he
_
ho
_
me
_
ow
_
ner
_
.
mr
.steam® lFeel Good Inc.
®
Installation, Operation & Maintenance Manual
iSteamX
When installing and using this electrical equipment, basic safety precautions
should always be followed, including the following:
IMPORTANT SAFETY INSTRUCTIONS
1. READ AND FOLLOW ALL INSTRUCTIONS
2.
3.
4. To reduce the risk of injury:
A. The wet surfaces of steam enclosures may be
slippery. Use care when entering or leaving.
B. The steam head is hot. Do not touch the
steamhead and avoid the steam near the
steamhead.
C. Prolonged use of the steam system can raise
excessively the internal human body tempera-
ture and impair the body’s ability to regulate
its internal temperature (hyperthermia). Limit
your use of steam to 10-15 minutes until you
are certain of your body’s reaction.
D. Excessive temperatures have a high
potential for causing fetal damage dur-
ing the early months of pregnancy.
Pregnancy or possibly pregnant women
should consult a physician regarding cor-
rect exposure.
E. Obese persons and persons with a history
of heart disease, low or high blood
pressure, circulatory system problems,
or diabetes should consult a physician
before using a steambath.
F. Persons using medication should consult a
physician before using a steambath since
some medication may induce drowsiness
while other medications may affect heart
rate, blood pressure and circulation.
SAVE THESE INSTRUCTIONS
HYPERTHERMIA
occurs when the internal tem-
perature of the body reaches a level several
degrees above the normal body temperature of
98.6° F. The symptoms of hyperthermia include
an increase in the internal temperature of the
body, dizziness, lethargy, drowsiness, and faint-
ing. The effects of hyperthermia include:
a) Failure to perceive heat;
b) Failure to recognize the need to exit the steambath;
c) Unawareness of impending risk;
d) Fetal damage in pregnant women;
e) Physical inability to exit the steambath; and
f) Unconsciousness.
The use of alcohol, drugs,
or medication can greatly
increase the risk of
hyperthermia.
READ ME FIRST!
WARNING
!
WARNING
!
1
®
! As you follow these
instructions, you will notice warning and
caution symbols. This blocked
information is important for the safe
and efficient installation and operation
of this generator. These are types of
potential hazards that may occur during
installation and operation:
! Indicates a potentially
hazardous situation, which, if not
avoided, could result in death or serious
injury.
Indicates a potentially
hazardous situation, which, if not
avoided may result in minor or
moderate injury or product damage.
This highlights information
that is especially relevant to a problem-
free installation.
All information in these instructions is
based on the latest product
information available at the time of
publication. Mr.Steam reserves the
right to make changes at any time
without notice.
Do not permit children
under the age of 16 to use this steambath.
Steam is hot and can
cause injury or death if improperly used.
Steam rooms contain steam and elevated
temperatures. Please read and observe all
warnings in this manual before installing or
using a steam room.
[email protected] • www.mrsteam.com
43-20 34th Street, Long Island City, NY 11101 Tel: 1 800 76 STEAM
9410 S. La Cienega Blvd. Inglewood CA 90301 el: 1 800 72 STEAM
®
PUR 100543 Rev 1.23
iSteamX Hub
®
Box Contents:
• iSteamX Control
• iSteamX Hub
• Power Supply
• Control Cable w/Mini-Din (30ft)
• iSteamX cable w/Screw connector (30ft)
• Steamhead
• Tube of silicone sealant
• Owner's manual
Table of Contents:
Important Safety Instructions . . . . . . . . . . . . . . . . . . .1
INSTALLER INFORMATION
Installation Template . . . . . . . . . . . . . . . . . . . . . . . . . .1
Box Content . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Dimensional Information . . . . . . . . . . . . . . . . . . . . . . .2
Before Installing . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Locating the Control . . . . . . . . . . . . . . . . . . . . . . . . . .4
Installation with Rough-In Box . . . . . . . . . . . . . . . . .4-5
Installation without Rough-In Box . . . . . . . . . . . . . . . .5
iSteamX®Installation . . . . . . . . . . . . . . . . . . . . . . . .6-7
USER/HOMEOWNER INFORMATION
Operating Instructions
Stand-By, Start, Dashboard, Set Timer . . . . . . . . . . . .9
Set Temperature, User Settings . . . . . . . . . . . . . . . .10
ChromaSteam®. . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
AudioSteam, AromaSteam . . . . . . . . . . . . . . . . . . . .11
Optional Accessories . . . . . . . . . . . . . . . . . . . . . . . .11
Settings: System Setting, Date and Time . . . . . . . . .12
AutoStart, Passcode, About . . . . . . . . . . . . . . . . . . .13
System Log . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Care Tips, Safety & Operating Info . . . . . . . . . . . . . .14
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Dimensional Information
KK3 ??!K
KK
3K??4K

 K3K??4K
(&/")*KK3K??4K
,0+/)+&K*,#"/),+K
KK3K??K
"##$..,-2K
#,++%#/),+.K
+,/ 0.$IJK
>K3 K??K
75555
K3K ??4K
iSteamX
Mounting Location
ACCESSORY
CONNECTIONS
iSteamX Connection
Power
Steam Generator Connection
LAN (Not Required)
Pigtail 8" [203 mm]
2
To avoid unintentional steambath
operation, do not locate the control where other
controls, accessories, shower heads, valves, body sprays
or similar within the shower could cause confusion or
interfere with the Mr.Steam control’s intended use and
function.
• To prevent possible injury Do Not use the iSteamX
control without reading and understanding the
Mr.Steam steam generator Installation and Operation
Manual.
•A peel and stick warning sticker is provided in the
Mr.Steam steam generator Installation, Operation and
Maintenance Manual. This manual is provided with
every steam generator. The warning sticker must be
read and permanently affixed in a conspicuous
location near the steam room. Failure to read and affix
this warning sticker in a conspicuous location may
result in serious injury or death. Please call Mr.Steam at
800 767-8326 for a free replacement or if you have any
questions regarding the warning sticker.
• If an iSteamX control is installed outside the steam
room a Remote Temperature Probe (PN MSTS) must
be installed inside the steam room per installation
instructions supplied with the Remote Temperature
Probe. Failure to install according to instructions will
result in an inoperative control and overheating of the
steam room.
Do not route iSteamX control wiring
inside conduit together with power lines or close to hot
water or steam piping. Doing so may result in an
inoperative or hazardous installation. Do not alter or
modify any Mr.Steam products including the steam
generator or iSteamX control. Doing so may result in an
inoperative or hazardous installation and will void the
warranty.
IMPORTANT NOTES:
• Turn power to the steam generator OFF before
connecting the control to the generator. Failure to turn
the power off will result in an inoperable control.
• Do not operate the iSteamX control with other than a
Mr.Steam iSteamX compatible steam generator.
Mr.Steam residential steam generators with serial
numbers lower than 1174000, or any other brand of
steam generator are not to be operated with iSteamX
controls. Doing so may result in an inoperative
installation. If your generator’s serial number is lower
than 1174000 contact Mr.Steam Technical Service for
up-grade options and components to enable your
steam generator to function with iSteamX.
• This document contains important safety, operation
and maintenance information. Leave this document
with the homeowner. Do not discard this document.
• Discontinue use of the steam generator or control if
the steam generator is damaged or otherwise not
functioning properly. Doing so may result in an
inoperative or hazardous installation
• Refer to the Steambath Generator Installation,
Operation and Maintenance Manual for locating and
installing the steamhead.
Do Not alter or modify any Mr.Steam
products. Doing so may result in an inoperable or
hazardous installation and will void the warranty.
3
INSTALLER INFORMATION
®
REDUCE THE RISK OF OVERHEATING AND SCALDING
1.
EXIT IMMEDIATELY IF UNCOMFORTABLE, DIZZY OR SLEEPY.
STAYING TOO LONG IN A HEATED AREA IS CAPABLE OF CAUSING OVERHEATING.
2. SUPERVISE CHILDREN AT ALL TIMES.
3. CHECK WITH A DOCTOR BEFORE USE IF PREGNANT, DIABETIC, IN POOR HEALTH
OR UNDER MEDICAL CARE.
4. BREATHING HEATED AIR IN CONJUNCTION WITH CONSUMPTION OF ALCOHOL,
DRUGS, OR MEDICATION IS CAPABLE OF CAUSING UNCONSCIOUSNESS.
5. DO NOT CONTACT STEAM HEAD OR STEAM AT THE STEAM HEAD.
REDUCE THE RISK OF SLIPPING AND FALL INJURY
1. USE CARE WHEN ENTERING OR EXITING THE STEAM ROOM. FLOOR MAY BE SLIPPERY
NOTE: FOR ADDITIONAL SAFETY CONSIDERATIONS SEE OWNER”S MANUAL
WHICH IS KEPT:_______________________________________
THE OWNER’S MANUAL CAN BE FOUND AT WWW.MRSTEAM.COM
USE OF STEAM ROOM IN CONJUNCTION WITH CONSUMPTION OF ALCOHOL CAN BE
DANGEROUS AND CAN RESULT IN INJURY THROUGH SLIP AND FALL OR OTHERWISE.
mr
.steam®
43-20 34th Street , Long Island City NY 11101 1 800 76 STEAM www.mrsteam.com PUR100378 8.18
Not actual size
PUR100378 3.22
4
INSTALLER INFORMATION
®
Locating the Control
Determine the desired installation location of the control. The iSteamX controls are designed to be installed inside or
outside the steam room as a matter of personal preference. If the control is installed inside the steam room:
• Locate the control 4-5 feet above the floor near the bather seating area.
• The control features an integral temperature sensor. Locate the control in a location representative of the desired steam
bathing temperatures. Do not locate the control above or near the steam head or direct steam emissions.
• Locate the control on a vertical wall.
• The control cable is 30 feet. Insure that the control and steam generator are located accordingly.
IMPORTANT NOTES:
• If required, contact Mr.Steam to purchase an optional 60’ iSteamX control cable part number 104541-60.
• If the control is installed outside the steam room a Remote Temperature Probe Part Number MSTS must be installed
inside the steam room. Refer to the MSTS installation manual before installing the control.
• Insure Mr.Steam steam generator is iSteamX compatible and has a serial number 1174000 or higher.
STEP 1
Make a 1-1/4" diameter hole in the desired control location.
STEP 2
Route the control cable from the wall cutout to the iSteamX
Hub. Plug in and thread the connector collar into the Hub at the
location marked Control.
IMPORTANT NOTE: The connector is keyed, it will only
connect one way.
IMPORTANT NOTE: Be careful not to strain, staple, pinch or
otherwise damage the control cable. Route cable as required to
permit replacement. Do not route cable inside conduit together
with power lines or close to hot water or steam piping.
5
INSTALLER INFORMATION
®
Installation Instructions for iSteamX
STEP 1.
Mount the hub securely. The hub may be mounted in any orientation.
Plug the 30 foot generator cable into the generator and into the hub.
Do not force or twist cable ends together. Forcing or twisting cable
ends may damage the connectors.
Plug the 30 foot control cable into the hub and into the iSteamX. Thread to connector
collars together.
iSteamX
iSteamX Pigtail
Hub
Hub
Generator Cable
Control cable
Steam Generator
6
INSTALLER INFORMATION
®
STEP 2
Peel the double stick adhesive off the back of the
iSteamX control (2a). Apply a bead of silicone around the
rear of the iSteamX control to create a moisture seal (2b).
Carefully feed the cables into the rough-in box and secure
the control to the wall. Care must be taken to not pinch
the cables. Ensure the control is level.
IMPORTANT NOTE: The control must be installed.
NOTE: The silicone supplied by Mr.Steam can be used to
meet a variety of sealing and gasketing. It cures to
silicone rubber and adheres to glass, wood, metal,
porcelain, ceramic tile, painted surfaces, many plastics
and rubber. Surfaces must be clean and dry. Apply thin
layer of product. Fit together and support if necessary.
Allow excess material to cure, then trim with a sharp
blade. Sealant “skins” in 5 minutes, dries to touch in 1
hour. Fully cures and bonds in 24 hrs.
IMPORTANT NOTE: Do not apply excessive amounts of
silicone. Do not apply silicone to any other parts of the
control including the adhesive gasket. Insure the
mounting surface is clean and dry as required for good
adhesion. Hold the control with the arrow on the screen
protector facing up and press the control against the wall
until the adhesive sticks and holds firmly. Control may
have to be supported or secured until the silicone has
cured for 24 hours.
Installation Instructions for iSteamX (cont.)
2a
2b
2c
®
When installing and using this electrical equipment, basic safety precautions
should always be followed, including the following:
IMPORTANT SAFETY INSTRUCTIONS
1. READ AND FOLLOW ALL INSTRUCTIONS
2.
3.
4. To reduce the risk of injury:
A. The wet surfaces of steam enclosures may be
slippery. Use care when entering or leaving.
B. The steam head is hot. Do not touch the
steamhead and avoid the steam near the
steamhead.
C. Prolonged use of the steam system can raise
excessively the internal human body tempera-
ture and impair the body’s ability to regulate
its internal temperature (hyperthermia). Limit
your use of steam to 10-15 minutes until you
are certain of your body’s reaction.
D. Excessive temperatures have a high
potential for causing fetal damage dur-
ing the early months of pregnancy.
Pregnancy or possibly pregnant women
should consult a physician regarding cor-
rect exposure.
E. Obese persons and persons with a history
of heart disease, low or high blood
pressure, circulatory system problems,
or diabetes should consult a physician
before using a steambath.
F. Persons using medication should consult a
physician before using a steambath since
some medication may induce drowsiness
while other medications may affect heart
rate, blood pressure and circulation.
SAVE THESE INSTRUCTIONS
HYPERTHERMIA
occurs when the internal
temperature of the body reaches a level
several degrees above the normal body
temperature of 98.6° F. The symptoms of
hyperthermia include an increase in the
internal temperature of the body, dizzi-
ness, lethargy, drowsiness, and fainting.
The effects of hyperthermia include:
a) Failure to perceive heat;
b) Failure to recognize the need to exit
the steambath;
c) Unawareness of impending risk;
d) Fetal damage in pregnant women;
e) Physical inability to exit the steambath;
and
f) Unconsciousness.
The use of alcohol, drugs,
or medication can greatly increase the
risk of hyperthermia.
For a replacement warning label
contact MrSteam customer service
at 1-800-76-STEAM or [email protected]
READ ME FIRST!
!
WARNING
Do not permit children
under the age of 16 to use this steambath.
!
WARNING
Steam is hot and can cause injury
or death if improperly used. Steam rooms contain
steam and elevated temperatures. Please read
and observe all warnings in this manual before
installing or using a steam room.
WARNING
!
!
WARNING
The peel and
stick warning label located in the
steam bath generator manual is
an essential part of providing a
safe environment for steam room
users. The peel and stick warning
label must be applied to the wall
of the shower or steam
enclosure, at a point that is vis-
ible to all users. Failure to install
this sticker may result in serious
injury or death.
The location where this owner’s
manual is kept shall be written in
the space provided on the label
using permanent ink.
WARNING
!
!
WARNING As you follow these instruc-
tions, you will notice warning and caution
symbols. This blocked information is impor-
tant for the safe and efficient installation and
operation of this generator. These are types
of potential hazards that may occur during
installation and operation:
!
WARNING Indicates a potentially
hazardous situation, which, if not avoided,
could result in death or serious injury.
!
CAUTION Indicates a potentially
hazardous situation, which, if not avoided
may result in minor or moderate injury or
product damage.
IMPORTANT NOTE: This highlights
information that is especially relevant to a
problem-free installation.
All information in these instructions is based
on the latest product information available at
the time of publication. MrSteam any time
without notice.
Not actual size.
As you follow these
instructions, you will notice warning and
caution symbols. This blocked
information is important for the safe and
efficient installation and operation of this
generator. These are types of potential
hazards that may occur during
installation and operation:
Indicates a potentially
hazardous situation, which, if not
avoided, could result in death or serious
injury.
Indicates a potentially
hazardous situation, which, if not
avoided may result in minor or moderate
injury or product damage.
IMPORTANT NOTE: This highlights
information that is especially relevant to
a problem-free installation.
All information in these instructions is
based on the latest product information
available at the time of publication.
Mr.Steam any time without notice.
! WARNING Do not permit children
under the age of 16 to use this steambath.
Steam is hot and can cause
injury or death if improperly used. Steam rooms
contain steam and elevated temperatures.
Please read and observe all warnings in this
manual before installing or using a steam room.
HOMEOWNER SECTION
REDUCE THE RISK OF OVERHEATING AND SCALDING
1.
EXIT IMMEDIATELY IF UNCOMFORTABLE, DIZZY OR SLEEPY.
STAYING TOO LONG IN A HEATED AREA IS CAPABLE OF CAUSING OVERHEATING.
2. SUPERVISE CHILDREN AT ALL TIMES.
3. CHECK WITH A DOCTOR BEFORE USE IF PREGNANT, DIABETIC, IN POOR HEALTH
OR UNDER MEDICAL CARE.
4. BREATHING HEATED AIR IN CONJUNCTION WITH CONSUMPTION OF ALCOHOL,
DRUGS, OR MEDICATION IS CAPABLE OF CAUSING UNCONSCIOUSNESS.
5. DO NOT CONTACT STEAM HEAD OR STEAM AT THE STEAM HEAD.
REDUCE THE RISK OF SLIPPING AND FALL INJURY
1. USE CARE WHEN ENTERING OR EXITING THE STEAM ROOM. FLOOR MAY BE SLIPPERY
NOTE: FOR ADDITIONAL SAFETY CONSIDERATIONS SEE OWNER”S MANUAL
WHICH IS KEPT:_______________________________________
THE OWNER’S MANUAL CAN BE FOUND AT WWW.MRSTEAM.COM
USE OF STEAM ROOM IN CONJUNCTION WITH CONSUMPTION OF ALCOHOL CAN BE
DANGEROUS AND CAN RESULT IN INJURY THROUGH SLIP AND FALL OR OTHERWISE.
mr
.steam®
43-20 34th Street , Long Island City NY 11101 1 800 76 STEAM www.mrsteam.com PUR100378 8.18
Not actual size
PUR100378 3.22
7
8
USER/HOMEOWNER INFORMATION
®
Operating Instructions
Set the steam bathing duration
and temperature according to personal
preference, however it is highly recommended to
begin steam bathing at a low temperature setting
to gauge comfort and safety levels. Set the
duration at 10 minutes maximum to gauge comfort
and safety levels. This will allow the steam
generator to heat up and begin producing steam.
Stand-By Screen
Touch anywhere on the clock screen to
wake up the control
Start Screen
Press the START button to turn the steam
generator on. If you had selected a user profile and
program when the control was woken up they
system will start with the saved parameters. Steam
will begin to slow a few minutes after the START
button is pressed. The time required for the steam
room to reach steam bathing temperature
depends on the steam room construction and
steam generator specifications
Start Screen
User settings can be adjusted two ways, while
steam is running drag the dashboard up from the
bottom of the screen. AromaSteam can be turned
ON/OFF, ChromaSteam can be turned ON/OFF
and color adjusted and the room temperature can
be adjusted.
Features
Touch to Start
Dashboard
Steam
Settings
ChromaSteam
AromaSteam
USER/HOMEOWNER INFORMATION
®
9
ChromaSteam
The ChromaSteam is an optional accessory
that activates colored lights in the steam
room. Press the ChromaSteam button to
access the dashboard. The light is turned
ON/OFF from the interface. Touch anywhere
on the color wheel to select that color. To
adjust brightness, use the slider on the
bottom of the ChromaSteam dashboard.
(Note: Brightness cannot be adjusted in
automatic color changing modes)
Press the discrete color selection button to
pick from a preselected set of colors or one
of the two color changing modes.
AromsSteam
The AromaSteam is an optional accessory that
automatically infuses aromatic oils into the steam
flow. Press the AromaSteam button to bring up
that AromaSteam dashboard
Return to
Main Screen
Increase
Temperature
Decrease
Temperature
Return to
Main Screen
Press to Select
Discrete Colors
Swipe
Up & Down
Swipe
Up & Down
Return to
Main Screen
Tounch Wheel
to Select
Color
Slide to
Adjust
Brightness
Press to Turn
ChromaSteam
On/Off
Return to
Main Screen
Tap to Turn
AtomaSteam
On/Off
Steam Settings
Steam settings can also be adjusted by tapping
the Steam Settings icon on the main screen. From
the steam setting screen select either Temperature
or Duration. To adjust temperature use the + and –
buttons. To adjust duration swipe the time up and
down. To return to the main screen tap the Xin the
upper right.