mr. steam MS-225E User manual

mr
.steam® Feel Good Inc.
Installation, Operation and Maintenance Manual
Steambath Generator Systems
Residential
Models 90E – 400E and Super 1E – 6E
64604_Brochur _PUR100472A_10047213-02-1115:38Pag 1

READ ME FIRST!
IMPORTANT NOTE
As you follow these
instructions, you will notice warning and cau-
tion symbols. This blocked information is
important for the safe and efficient installation
and operation of this generator. These are
types of potential hazards that may occur
during installation and operation
states a hazard may cause serious injury or death if pre-
cautions are not followed.
signals a situation where minor injury or
product damage may occur if you do not
follow instructions.
IMPORTANT NOTE
This highlights
information that is especially relevant to a problem-free
installation.
All information in these instructions is based on
the latest product information available at the
time of publication. Sussman-Automatic Corporation
reserves the right to make changes at any time
without notice.
HYPERTHERMIA occurs when the internal temperature
of the body reaches a level several degrees above the
normal body temperature of 98.6° F.
The symptoms of hyperthermia include an increase in the
internal temperature of the body, dizziness, lethargy,
drowsiness, and fainting. The effects of hyperthermia
include
mr.steam® Sussman-Automatic Corporation® [email protected] www.mrsteam.com
43-20 34th Street, Long Island City, NY 11101 TEL 1 800 76 STEAM FAX 718 472 3256
9410 S. La Cienega Blvd. Inglewood CA 90301 TEL 1 800 72 STEAM FAX 310 216 2944 M A D E I N U S A
PUR 100472-A Rev 1.13
When installing and using this electrical equipment, basic safety precautions
should always be followed, including the following
IMPORTANT SAFETY INSTRUCTIONS
1. READ AND FOLLOW ALL INSTRUCTIONS
2.
Do not permit children
under the age of 16 to use this steambath.
3.
To reduce the risk of injury
A.The wet surfaces of steam enclosures may
be slippery. Use care when entering or
leaving.
B. The steam head is hot. Do not touch the
steam head and avoid the steam near the
steam head.
C. Prolonged use of the steam system can
raise excessively the internal human body
temperature and impair the body’s ability
to regulate its internal temperature
(hyperthermia). Limit your use of steam to
10-15 minutes until you are certain of
your body’s reaction.
D. Excessive temperatures have a high
potential for causing fetal damage
during the early months of pregnan-
cy. Pregnancy or possibly pregnant
women should consult a physician
regarding correct exposure.
E. Obese persons and persons with a
history of heart disease, low or high
blood pressure, circulatory system
problems, or diabetes should consult
a physician before using a steam-
bath.
F. Persons using medication should con-
sult a physician before using a
steambath since some medication
may induce drowsiness while other
medications may affect heart rate,
blood pressure and circulation.
SAVE THESE INSTRUCTIONS
a) Failure to perceive heat;
b) Failure to recognize the need to exit the steambath;
c) Unawareness of impending risk;
d) Fetal damage in pregnant women;
e) Physical inability to exit the steambath; and
f) Unconsciousness.
The use of alcohol, drugs, or medication can greatly increase the risk of hyperthermia.
WARNING
!
WARNING
!
WARNING
!
WARNING
!
CAUTION
!
64604_Brochur _PUR100472A_10047213-02-1115:38Pag 2

RESIDENTIAL STEAMBATH GENERATOR SYSTEMS
INSTALLATION, OPERATION & MAINTENANCE MANUAL
MODELS MS-90E, MS-150E, MS-225E, MS-400E, MS-SUPER 1E,
MS-SUPER 2E, MS-SUPER 3E, MS-SUPER 4E, MS-SUPER 5E, MS-SUPER 6E
TABLE OF CONTENTS
Read Me First! & Warning Sticker . . . . . . . . . Inside front cover
Select Your Mr.Steam Model . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Specification Chart. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
_______________________________________________________________________
INSTALLER’S SECTION
Before Installing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Steam Room Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Water Quality Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Locating the Steam Generator. . . . . . . . . . . . . . . . . . . . . . . . . 4
Typical Installation Instructions. . . . . . . . . . . . . . . . . . . . . . . . . 5
Installation Plumbing, Water Supply, Drain, Steam Outlet
Safety Valve, Drip Pan, AromaSteam . . . . . . . . . . 6
Steam Head Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Steam Generator Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . 8
Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Field Power Wiring. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-11
Optional Tandem Cable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Initial Start-Up & Checkout . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Optional & Accessary Equipment . . . . . . . . . . . . . . . . . . . . . 12
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
System Status Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Optional AutoFlush System . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Optional Drip Pan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Optional Express Steam. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Liquid Level Control Board . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Parts Identification Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . 16
Replacement Parts List. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
CONTROL INSTALLATION
Before Installing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Control Rough-In . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Safety and Operating Information. . . . . . . . . . . . . . . . . . . . 19
_______________________________________________________________________
HOMEOWNER’S SECTION
Using the AromaSteam Essential Oils. . . . . . . . . . . . . . . . . . 20
Care Tips and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . 21
Steam Generator Maintenance & Operation . . . . . . . . . . . . 21
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
mr
.steam® Feel Good Inc.
MODEL _______________________________
SERIAL NO. ___________________________
64604_Brochur _PUR100472A_10047213-02-1115:38Pag 3

2
Materials of construction, room size and special design features such
as large glass areas, all affect the steam generator model selection.
1.
Measure length, width & height in feet of the steam/shower or tub/shower
Multiply the Length ____ x Width_____ x Height _____ =
2.
Construction Materials
For natural stones natural marble, Add 110%
stone, shale, glass block or concrete
For ceramic or porcelain tile on Add 40%
cement board or mortar bed
3.
Ceiling Height For each foot above 8 feet Add 15%
4. Add all figures above to obtain the Total Room Volume required
ROOM VOLUME
SELECT YOUR MR.STEAM
Compare your Room Volume to the Chart below
and select the appropriate model.
In considering the purchase or
use of this steambath system, please note that if
you are pregnant, have a coronary condition, are
in poor health, are being treated for any other
medical condition, or are using medication or
drugs, Mr.Steam recommends that you obtain
the approval of a physician before use.
For information about this product and safety
issues, please call 1.800.76.STEAM
IMPORTANT NOTES
For steam rooms constructed of acrylic or
synthetic materials, select next lower-rated
MS model.
The Mr.Steam Sizing Chart allows for up to
60 feet of insulated steam line from the MS
generator to the steam room. If the 60 foot line
is exceeded consult with factory. The steam
generator control locations must be taken into
account. A 30 foot cable is standard. Contact
Mr.Steam to purchase an optional 60 ft. cable
(PN 103990-60) for iTempo controls. A 60 foot cable
is not available for use with iSteam controls.
R E S I D E N T I A L S T E A M G E N E R AT O R S S P E C I F I C AT I O N C H A R T
Amps (for Wire Total Adj. Water Usage Shipping
Model No. KW 240v/1PH)† Size‡ Room Vol. gallons†† Dimensions* Wt. (lbs)**
MS90E 5 21 10 100 0.67 14½"L x 14¾"H x 6¾"D 30
MS150E 6 25 8 150 0.80 14½"L x 14¾"H x 6¾"D 30
MS225E 7.5 32 8 225 1.0 14½"L x 14¾"H x 6¾"D 30
MS400E 9 38 8 360 1.2 14½"L x 14¾"H x 6¾"D 30
MS SUPER 1E 10 42 8 475 1.4 17"L x 18½"H x 77⁄8"D 40
MS SUPER 2E 12 50 6 575 1.6 17"L x 18½"H x 77⁄8"D 40
MS SUPER 3E 15 63 4 675 2.0 17"L x 18½"H x 77⁄8"D 40
MS SUPER 4E 20 84 8 875 2.7 17"L x 18½"H x 77⁄8"D x 2 80
MS SUPER 5E 24 100 6 1075 3.2 17"L x 18½"H x 77⁄8"D x 2 80
MS SUPER 6E 30 125 4 1275 4.0 17"L x 18½"H x 77⁄8"D x 2 80
IMPORTANT NOTES
• Add C1 suffix to Model No. for 240V/1Ph; Add B1 suffix to Model No. for 208V/1Ph.
• Models SUPER 1E-6E must use iTempo/Plus™control.
• All Mr.Steam MS Models are cULus Listed and CE approved.
NOTES
All MS Generators available in 240v/1PH, 208v/1PH and other voltages/phases.
† Amps are for 240/1PH rated units.
‡Wire size (AWG) based on minimum 90˚C rated THHN copper conductors.
Refer to the National Electrical Code for other types of conductors.
See Mr. Steam® Installation and Operation Manual for complete dimensional and installation information.
MS SUPER 4E includes two MS SUPER 1E steam generators, and require one iTempo/Plus™Control, and two matching steamheads. MS SUPER 5E includes two MS SUPER
2E steam generators, and require one iTempo/Plus™Control, and two matching steamheads. MS SUPER 6E includes two MS SUPER 3E steam generators, and require one
iTempo/Plus™Control, and two matching steamheads.
*Dimensions are for generator only, without
AutoFlush® or plumbing features.
**Shipping weight and pricing are for generator only,
without control or steamhead.
†† Water usage based on 20 minutes of operation.
WARNING
!
mr
.steam
®Installation, Operation & Maintenance Manual
__________________________________________________________________________
Mr.Steam @ Your Fingertips
Start working smarter with Mr.Steam’s mobile sizing app,
now available for the iPad®, iPod®and most smart phones.
Visit mrsteam.com to size your generator automatically
or go directly to http //isizing.mrsteam.com
64604_Brochur _PUR100472A_10047213-02-1115:38Pag 4

If acrylic, fiberglass or other non-heat resistant materials are used as
part of the steam room enclosure. Consult with the material manufac-
ture and see pg. 7, “Installing the Steamhead" for additional details.
IMPORTANT NOTES
This document contains important safety, operation and maintenance
information. Leave this document with the homeowner. Do not discard
this document.
The following general information should be used in conjunction with
consultations with an architect, designer and contractor in determining
factors necessary in providing a suitable and safe steam room.
Mr.Steam steam generators are intended to be operated with Mr.Steam
iSteam®, iTempo/Plus™, iTempo™Home Wizard™and iGenie®controls
only, and are to be installed strictly in accordance with the specific
instructions contained in this manual and as supplied in the manuals
provided with the controls or accessories.
Never use damaged equipment, doing so may result in an
inoperative or hazardous installation.
Discontinue use of the steam generator and control if the steam
generator or control are damaged or otherwise not functioning
properly. Doing so may result in an inoperative or hazardous
installation
ELECTRICAL SHOCK HAZARD. Mr.Steam steam generators are
connected to 240V line voltage and contain live electrical com-
ponents. All installation and service to be performed by quali-
fied and licensed electricians and plumbers only. installation or
service by unqualified persons or failure to use Mr. Steam parts
may result in property damage or in a hazardous condition.
The MS series of steam generators are for residential use only.
Commercial or other nonresidential applications void the war-
ranty and may adversely affect product performance and may
represent a safety hazard.
10. Limit steam room ceiling height to 8 feet. Exceeding
8 feet may require a higher-rated steam generator.
The peel and stick warning sticker provided in
the Steambath Generator Manual must be read and permanently
affixed in a conspicuous location near the steam room. Failure to
read and affix this warning sticker in a conspicuous location may
result in serious injury or death.
BEFORE INSTALLING
Carefully inspect the Steam Generator and packaging for
shipping damage. In the event of shipping damage,
please contact the carrier for claim information. Our
customer service department can assist you with any
missing or damaged parts.
Read these instructions before installation or service.
Although this MS steambath generator has been fully
qualified for shipment by Mr.Steam®, the following must
be reviewed for proper, safe and enjoyable steam bathing
1. Verify that the model and accessories specifications are
correct for the incoming line voltage.
2. Insure steambath generator has been correctly sized
STEAM ROOM GUIDELINES
1. Steam room must be completely enclosed, with full
walls, door, floor and ceiling.
2. It is recommended that a gasketed door is used for
steam containment.
3. If tile-type or other smooth surfaced flooring is used
provide suitable anti-skid strips or equivalent, to
prevent a slippery hazard.
4. Check the suitablility of any materials with the
manufacturer. Walls and ceilings must be constructed
of water-resistant, non-corrosive surface, such as tile,
marble, molded acrylic, or other non-porous material.
5. The ceiling should be sloped to prevent dripping of
condensate.
6. Provide a floor drain.
7. No heating, venting or air conditioning devices
should be installed inside the steam room.
8. Steam room tile construction information is
available from the Tile Council of America, Inc. by
purchasing the TCA Handbook for Ceramic Tile
Installation. Tel. (864) 646-8453 or www.tileusa.com.
9. Windows that are part of the steam room should be
double paned and tempered safety glass.
for the steambath room. Pay particular attention to room
volume and construction. If any questions, please refer
to Mr. Steam sizing and selection guide on page 2.
3. Marble or glass walls or ceilings. “ENLARGE” the room’s
size, requiring a generator larger than one based only on
the room’s cubic foot (L x H x W) volume.
4. The physical size of the unit, clearance for plumbing
servicing, and its distance from the steam room must all
be considered before final installation.
5. Consider any controls and accessories before initiating
installation. Read the Installation and Operation Manual
of all controls and accessories available at
www.mrsteam.com technical downloads.
Not Actual Size
REDUCE THE RISK OF OVERHEATING AND SCALDING
1.
EXIT IMMEDIATE Y IF UNCOMFORTAB E, DIZZY OR S EEPY.
STAYING TOO ONG IN A HEATED AREA IS CAPAB E OF CAUSING OVERHEATING.
2. CHI DREN UNDER THE AGE OF 16 SHOU D NOT USE THE STEAM BATH.
3. CHECK WITH A DOCTOR BEFORE USE IF PREGNANT, DIABETIC, IN POOR
HEA TH OR UNDER MEDICA CARE.
4. BREATHING HEATED AIR IN CONJUNCTION WITH CONSUMPTION OF A COHO ,
DRUGS, OR MEDICATION IS CAPAB E OF CAUSING UNCONSCIOUSNESS.
5. DO NOT CONTACT STEAM HEAD OR STEAM AT THE STEAM HEAD.
REDUCE THE RISK OF SLIPPING AND FALL INJURY
1.
USE CARE WHEN ENTERING OR EXITING THE STEAM ROOM. F OOR MAY BE S IPPERY.
NOTE: FOR ADDITIONA SAFETY CONSIDERATIONS SEE OWNER’S MANUA
mr
.steam®43-20 34th Street , ong Island City NY 11101 1 800 76 STEAM www.mrsteam.com PUR100378 6.4/08
WARNING
!
WARNING
!
WARNING
!
CAUTION
!
3
I N S T A L L E R
mr
.steam
®Installation, Operation & Maintenance Manual
__________________________________________________________________________
64604_Brochur _PUR100472A_10047213-02-1115:38Pag 5

LOCATING THE STEAM GENERATOR
Select a location as near as practical to the steam room.
Typical locations include closet, vanity cabinet, heated attic or basement.
NOTE
The standard length of the cable for connecting the control to the steam generator is 30 feet.
The steam generator and control must be located accordingly. A 60 foot cable (PN 103990-60) is available
as a special order part, for eTempo and iTempo controls. A 60-foot cable cannot be used with iSteam.
(Items 1-7)
1. DO NOT install steambath generator or plumbing lines
in unheated attic or any locations where water could
freeze.
2. DO NOT install steambath generator inside steam
room.
3. DO NOT install steambath generator outdoors or
wherever environmental conditions may affect the
safety and/or performance of the generator.
4. DO NOT install steambath generator near flammable or
corrosive materials or chemicals such as gasoline, paint
thinners, or the like. Installation in areas having high
concentrations of chlorine (such as pool equipment
room) must be avoided.
5. Install steambath generator on a solid and level surface.
Keyhole slots are provided for wall mounting. Insure the
steam generator is properly secured and level when
mounting with keyhole slots.
6. Install steambath generator in an upright position only.
7.
Steam line, safety valve, drain valve and plumbing
become hot during operation and remain hot after
shutdown for a period of time. Provide appropriate
protection, including insulating plumbing lines.
Avoid plumbing runs and steamhead locations that
can come in contact with bathers.
IMPORTANT NOTES (Items 8-11)
8. Install anti-water hammer device as necessary.
9
.
Provide a minimum of (12) inches at both ends and
top of the steam generator or as required for servicing.
See page 8.
10.
Provide unions as required to facilitate installation
and disconnection of piping.
11
. Mr.Steam controls can be located inside the steam
room or on the outside of the steam room.
See the Control Installation Manual for your specific
control package for specific details.
12. The MS series of steam generators are for residen-
tial use only. Commercial or other nonresidential
applications void the warranty and may adversely
affect product performance and may represent a
safety hazard.
NOTE
Mr.Steam Generators (inclusive of the iTempo
™
and iSteam series Controls) are CE and UL listed.
Suitable for operation in ambient not exceeding 45 °C
(113˚ F)
WATER QUALITY INFORMATION
For optimum results, the water supply should be tested prior
to installation. If the mineral content exceeds the following
recommended limits, various external treatment processes
are recommended to correct the problem.
NOTE An analysis of the on-site water must be made by a
recognized and reliable water treatment company to ascertain
the existing condition and treatment required.
Poor water quality can affect efficiency or result in steam
generator damage. Water contains impurities in solution and
suspension. These impurities concentrate in the generator.
The concentration of these impurities increases as more
feedwater is introduced into the generator and steam is pro-
duced. If the suspended solids are allowed to concentrate
beyond certain limits, a deposit or “scale” will form on the
generator internal surfaces. This deposit can interfere with
the proper generator operation and cause generator failure.
The concentration of these impurities is generally controlled
by the water quality and by periodic draining of the generator.
RECOMMENDED FEEDWATER QUALITY
Hardness, ppm 8 – 85 (~0.5 – 5 gpg)
P-Alkalinity, ppm 85 – 410 (~5 – 24 gpg)
T. Alkalinity, ppm 200 – 500 (~7 – 0 gpg)
pH (strength of alkalinity) 8.0 – 11.4
Every 2 months, or more often in “hard” water areas,
the manual drain valve should be opened fully flushing
out accumulated materials, salts and other particles
which are natural by-products of boiling water.
The optional AutoFlush System feature automatically
drains the Mr.Steam® generator following each use.
A time delay allows the water to cool down (about
two hours) before it drains by gravity for a safe and
gentle operation.
WARNING
!
WARNING
!
4
I N S T A L L E R
mr
.steam
®Installation, Operation & Maintenance Manual
__________________________________________________________________________
64604_Brochur _PUR100472A_10047213-02-1115:38Pag 6

TYPICAL INSTALLATION INSTRUCTIONS
FOR MODELS MS SUPER 4E, 5E & 6E
(shown with optional AutoFlush)
1. Install each steam generator as in a single installation. Install generators
as close as practical to each other, not exceeding 10 feet. The
interconnecting cable length is 12 feet.
2. IMPORTANT NOTE Power must be disconnected at the
main electrical supply. Remove steam generator cov-
ers. Retain screws and covers for reuse.
3. Connect the iSteam®or iTempo/Plus™control to
either unit as per the Installation Manual supplied
with each control.
4. Remove one knock-out on each generator as shown.
Insert the ends of interconnecting cable provided
(PN 103904) through the knock-outs as shown in
diagram. Connect each end to the printed circuit
board connector labeled "TANDEM" as shown.
5. Prevent the interconnecting cable from contacting
hot surfaces such as steam outlet, safety valve and
the like.
6. Connect separate plumbing and power supplies
for each unit. Replace covers with cover screws.
7.
Provide unions as required to facilitate installation
and disconnection of piping
NOTE The secondary unit will de-energize when the
steam room reaches steambathing temperature resulting
in a more gentle and energy efficient operation.
Printed Circuit Board Component
shown enlarged for illustrative purpose.
Primary Unit
Interconnecting
Cable PN 103904
Control
Cable
Secondary Unit
iSteam
®
or
iTempo/Plus
™
Control
Optional AutoFlush®, see AutoFlush®
Installation page 13
Steam Heads
shown with
optional acrylic
shields
Water Feed
ine
Power
Supply
NOTE Drawings for illustrative purposes only.
Consult with qualified designer, architect or
contractor for steam room construction details.
Provide unions as required to facilitate
installation and disconnect of piping
Steam
Generator
Field installed
power supply
Field installed
steam supply pipe
Drain Valve must be closed
when the optional
AutoFlush is not installed
Control cable
(located behind
the wall)
Steam Head (shown with optional acrylic shield)
See page 7 for Steam Head Installation information
iSteam
®
, iTempo
™
or iTempo/Plus
™
Control
Refer to Control
Installation Manual
for installation
information
Field installed
water supply line
The control features an integral
temperature sensor. ocate the control in a location
representative of the desired steambathing temper-
atures. Do not locate the control above or near the
steam head or direct steam emissions.
TYPICAL MR.STEAM INSTALLATION
When installing the optional AromaSteam, install a
downward facing 90-degree T in the steam supply
line. See the AromaSteam Installation Manual for
complete information.
To avoid unintentional steambath operation, do not locate the control
where other controls, accessories, shower heads, valves, body sprays or similar within the
shower could cause confusion or interfere with the Mr.Steam control’s intended use and function.
CAUTION
!
CAUTION
!
5
I N S T A L L E R
mr
.steam
®Installation, Operation & Maintenance Manual
__________________________________________________________________________
All drawings are for illustrative purposes only
64604_Brochur _PUR100472A_10047213-02-1115:38Pag 7

INSTALLATION
PLUMBING
All plumbing shall be performed by a qualified licensed plumber and
in accordance with applicable National and local codes.
1. Use unions on all pipe connections.
2. Use only brass piping or copper tubing as permitted by codes.
3. Do not use black, galvanized, PVC pipe or PEX.
WATER SUPPLY (3⁄8" NPT)
1. Connect to cold water line.
2. Provide a shut off valve in the water supply line upstream of the steambath generator.
3. Do not overheat inlet solenoid valve with solder connections. Overheating will damage parts.
4. Flush inlet water line thoroughly before making connection to unit.
5. Strainer recommended upstream of feed water connection.
6. For best performance water pressure should be 15 to 20 psig. Reduce pressure as required.
7. Provide anti-water hammer device as required.
8. Install an approved backflow preventer as required by local codes.
DRAIN (1⁄2" NPT)
The drain from the generator should not share an undersink trap,
unless the generator is mounted higher than the sink.
NOTE A drain valve is provided to facilitate servicing. Provide a drain line connection from steambath
generator drain valve according to National and local Codes. Check local plumbing code for receptor, trap
and vent requirements. Do not connect Drain line and Safety Valve line together. Unit drains by gravity.
Do NOT connect the drain valve to the steam line
STEAM OUTLET (1⁄2" NPT)
1. Do not install any valve in steam line. Flow of steam must be unobstructed.
2. Use 1/2-inch brass pipe or copper tubing from unit to steam head as permitted by codes.
3. Insulate steam line using pipe insulation rated 212° F or higher.
4. Pitch steam line 1/4" per foot towards steam head or steam generator to avoid valleys and trapping of
condensate.
NOTE Running the steam line down and then up will create a steam trap blocking the flow of steam.
NOTE A 1.5" hole in the steam room is required to mount the steamhead.
SAFETY VALVE (3⁄4" NPT)
Where permitted by local codes, provide an outlet plumbing connection for safety valve.
To insure proper and automatic safety valve operation DO NOT connect a shut off valve
or a plug at safety valve outlet. DO NOT connect a shut off valve or any obstruction in steam supply pipe.
Do NOT connect the safety-valve output into the steam line.
DRIP PAN
Mr. Steam strongly recommends the use of a drip pan in the unlikely event of a plumbing leak. Check local
plumbing codes for receptor, trap and vent requirements. Drip pans drain by gravity. The drip pan is
equipped with an integral 3/4" fitting. See page 15 for additional drip pan installation information .
AROMASTEAM
If the optional AromaSteam Electronic Oil Delivery System (PN MS AROMA) is to be installed, a 90 degree T
plumbing fitting must be installed at a designated location on the steam outlet line. See the Mr.Steam
AromaSteam Operation and Instruction Manual (PN 100402) for installation information before the steam
line is installed at the technical downloads section of www.mrsteam.com
WARNING
!
6
I N S T A L L E R
mr
.steam
®Installation, Operation & Maintenance Manual
__________________________________________________________________________
64604_Brochur _PUR100472A_10047213-02-1115:38Pag 8

Steam
Supply P ipe
End of pipe to be recessed
1/4" (without Acrylic Shield)
1/8" (with Acrylic Shield)
1/8" minimum clearance required
when Acrylic Shield is used.
See installation instructions provided
with the Acrylic Shield.
Apply with silicone or equal
sealant as required for
moisture seal.
Use Teflon®or
equal sealant on
pipe threads
7
NOTE A 1
1⁄2
" clearance hole around the steam pipe is
needed to mount the steamhead.
STEP 1
Locate steam head 6-12 inches above floor, except for
1. Tub/shower enclosures, install 6 inches above tub top edge.
2. For enclosures with acrylic or other non-heat resistant
flooring install Acrylic Shield Part Number MS-103938.
STEP 2
Install steamhead with the oil well facing up as shown.
Hand tightening is sufficient when teflon or equal pipe thread
sealing compound is used.
STEP 3
Secure a bronze drop ear fitting to a header and run a
1⁄2
"
copper steam line from the steam generator to the drop ear
fitting. Install a temporary nipple (6" or longer) in the drop ear
fitting to locate the steamhead after the wall is finished.
STEP 4
After the wall has been finished, mark on the nipple where the
surface of the wall is. Remove the nipple and measure the
portion that was in the wall (the end to your mark). Subtract
1⁄4" from that dimension and select a brass nipple of that
length to finish the installation.
STEP 5
Wrap teflon tape around the threads of the new nipple and screw
the nipple into the steamhead. Do not use wrenches or tools
which would damage the steamhead's finish.
Wrap teflon tape around the threads of the nipple and screw the
nipple and steamhead assembly you just made into the drop ear
fitting in the wall. The steamhead should be flush with the wall
and the well must be facing up.
__________________________________________________________
IMPORTANT NOTE Do not disassemble steamhead.
Mr.Steam’s steamhead is shipped fully assembled and requires
no additional assembly.
To preserve steam head finish, do not use wrench or other
tools to tighten. DO NOT use abrasive cleansers or chemicals.
Use only water with mild soap and a non-abrasive sponge.
Because the steam head and direct steam emissions are very
hot, locate the steam head where incidental contact by bather
with the steam head or direct steam emission cannot occur.
Consult with supplier of acrylic, fiberglass and other non-heat
resistant enclosures for recommended steamhead location.
Use Acrylic Shield PN MS-103938 (round) or PN MS-103938SQ
(square). See instructions provided with steam shield.
Oil Well
STEP 3
STEP 4
STEP 5
INSTALLING THE ROUND OR SQUARE
AROMASTEAM STEAMHEAD (1⁄2" NPT)
Steamhead
(shown with
optional acrylic shield
)
Locating Nipple
Drop Ear
Fitting
CAUTION
!
I N S T A L L E R
mr
.steam
®Installation, Operation & Maintenance Manual
__________________________________________________________________________
All drawings are for illustrative purposes only
64604_Brochur _PUR100472A_10047213-02-1115:38Pag 9

8
K
12””
for servicing
L
I
H
G
F
A
B
C
D
E
M
GENERATOR DIAGRAM
MS 90E- MS 400E MS Super 1E-3E
_______________________________________
A
5 (127) 71⁄4(184)
B
81⁄8(206) 97⁄8(251)
C
111⁄4(392) 151⁄2(394)
D
141⁄4(392) 183⁄4(476)
E
17⁄8(48) 11⁄4(32)
F
2 (51) 21⁄4(57)
G
57⁄8(149) 6 (152)
H
5 (127) 47⁄8(124)
I
67⁄8(175) 77⁄8(200)
J
2 (51) 2 (51)
K
141⁄2(368) 17 (432)
L
21⁄2(64) 21⁄2(64)
M
63⁄8(162) 63⁄8(162)
WATER INLET 3⁄8” NPT
STEAM OUTLET 1⁄2” NPT
SAFETY VALVE 3⁄4” NPT
MANUAL DRAIN VALVE 1⁄2” NPT
AUTOFLUSH VALVE 1⁄2” NPT
NOTES
1. M =Optional AutoFlush
2. All units in inches (MM)
3. MS Super 4E includes (2) MS Super 1E units
4. MS Super 5E includes (2) MS Super 2E units
5. MS Super 6E includes (2) MS Super 3E units
J
Water Inlet
Control &
Accessory
Connections
Steam Outlet
Safety Valve
Optional AutoFlush
IMPORTANT NOTES
Provide a minimum of (12) inches at both ends and top of
the steam generator or as required for servicing. Alternately,
provide unions as required to facilitate installation and dis-
connection of the steam generator.
The minimum clearance from combustible surfaces is zero
all around.
Side View Showing
Element Access Panel
Manual Drain Valve
mr
.steam
®Installation, Operation & Maintenance Manual
__________________________________________________________________________
I N S T A L L E R
All drawings are for illustrative purposes only
TO AVOID EQUIPMENT
DAMAGE DO NOT
CONNECT POWER
SUPPLY DIRECTLY TO
ELEMENTS !!!
64604_Brochur _PUR100472A_10047213-02-1115:38Pag 10

Transformer
Liquid Level
Control Board
Water Feed
Solenoid
Water Feed
Liquid
Level Probe
AutoFlush
®
Plug and
Play Connection
(see page 14)
Fuses
Contactor
Power Block
Power Supply
Knock-Out
Steam
Outlet
Field
Wiring
Transformer
Liquid Level
Control Board
Water Feed
Solenoid
Steam Outlet
Liquid
Level Probe
AutoFlush®Plug and
Play Connection
(see page 14)
Contactor
Power Supply
Knock-Out
Field
Wiring
Water Feed
FIELD POWER WIRING
1. TO AVOID EQUIPMENT DAMAGE
DO NOT CONNECT POWER SUPPLY
DIRECTLY TO ELEMENTS!!!
2. L1, L2, Ground to be field wired
3. Super 1E 240/1 models
are not supplied with internal fusing.
4. All Drawings are for illustrative
purposes only. Consult with qualified
licensed electrician for electrical
installation.
Models MS 90E–MS 400E
(single phase wiring shown)
Models MS Super 1E-6E
(single phase wiring shown)
ELECTRICAL
All electrical wiring to be installed by
a qualified licensed electrician in accordance with
National Electrical Code and local electrical code.
POWER WIRING
See “Field Power Wiring” Diagrams (below)
1. Check power voltage. Use 240V rated unit when sup-
ply is greater than 208V. (Most homes have 240V, 1PH
service). Use 208V rated unit for 208V power.
2. Use minimum 90˚ C/300V rated insulated copper
conductors only, sized in accordance with National
Electrical Code and local electrical code for the current
in Ampere Chart. If allowed by codes, NM cable may
require a larger wire size than as listed on the chart.
3. Connect suitably sized equipment grounding wire
to ground terminal provided.
4. Install a separate circuit breaker between supply and
unit. Provide a power supply disconnect within sight
of the steam generator or one that is capable of being
locked in the open position.
5.
For single phase units, use two-wire supply source and
equipment grounding wire. Neutral (white) wire is not
required.
ELECT RICAL CHART
_________________________________________________________________________________ _______________________
Vol Max Room Wire Size Wire Size
Model No. (Cu. Ft.*) KW Volts
†
Phase Amps (AWG)for 40˚ C (AWG) for 45˚ C
Ambient Ambient
________________________________________________________________________________________________________
208 1 24 10 8
MS-90E 100 5.0 3 14 12 12
240 1 21 10 10
3 12 12 12
________________________________________________________________________________________________________
208 1 29 88
MS-150E 150 6.0 3 17 10 10
240 1 25 88
3 14 12 12
________________________________________________________________________________________________________
208 1 36 88
MS-225E 225 7.5 3 21 10 10
240 1 32 88
3 18 10 10
________________________________________________________________________________________________________
208 1 44 8 6
MS-400E 360 9.0 3 25 88
240 1 38 88
3 22 10 10
________________________________________________________________________________________________________
208 1 49 66
MS-Super 475 10.0 3 28 88
1E 240 1 42 86
3 24 88
________________________________________________________________________________________________________
208 1 58 64
MS-Super 575 12.0 3 34 88
2E 240 1 50 66
3 29 88
________________________________________________________________________________________________________
208 1 73 43
MS-Super 675 15.0 3 42 86
3E 240 1 63 44
3 36 88
________________________________________________________________________________________________________
*See page 2 for room sizing.
†
All specifications shown are for 208V and 240V Consult factory for other voltage specifications.
9
PROVIDE A POWER SUPPLY DISCONNECT WITHIN SIGHT OF THE STEAM GENERATOR OR ONE
THAT IS CAPABLE OF BEING LOCKED IN THE OPEN POSITION AS REQUIRED BY CODE.
I N S T A L L E R
mr
.steam
®Installation, Operation & Maintenance Manual
__________________________________________________________________________
WARNING
!
WARNING
!
64604_Brochur _PUR100472A_10047213-02-1115:38Pag 11

FAC T ORY
WIRING
FIELD
WIRING
LEGEND
(All Diagrams)
CONTACTOR
HEATING ELEMENT TO PROBE CONTROL BOARD
AutoFlush
(optional)
SteamGenie or
iGenie (optional)
iSteam, iTempo
or iTempo/Plus
Control
TRANSFORMER
POWER INPUT
GROUND
WATER
FEED
SOLENOID
VALVE
CONTACTOR
HEATING ELEMENT
TO PROBE CONTROL BOARD
AutoFlush
(optional)
SteamGenie or
iGenie (optional)
iSteam or
iTempo/Plus
Control
TRANSFORMER
POWER INPUT
GROUND
WATER
FEED
SOLENOID
VALVE
FUSES
POWER INPUT
TRANSFORMER
CONTROL BOARD
CONTACTOR
GROUND
HEATING ELEMENT
TO PROBE
WATER
FEED
SOLENOID
VALVE
AutoFlush
(optional)
SteamGenie or
iGenie (optional)
iSteam, iTempo
or iTempo/Plus
Control
SINGLE PHASE 208/240 VOLT WIRING DIAGRAMS
THREE PHASE 208/240 VOLT WIRING DIAGRAM
MODELS MS90E, MS150E,
MS225E, MS400E
MODELS MS SUPER-1E,
MS SUPER-2E,
MS SUPER-3E
(Note Super 1E 240V
does not have fuses)
MODELS MS90E, MS150E,
MS225E, MS400E,
MS SUPER-1E,
MS SUPER-2E,
MS SUPER-3E
10
I N S T A L L E R
mr
.steam
®Installation, Operation & Maintenance Manual
__________________________________________________________________________
64604_Brochur _PUR100472A_10047213-02-1115:38Pag 12

INSTALLATION INSTRUCTIONS
FOR MODELS MS-SUPER 4E, MS-SUPER 5E AND MS-SUPER 6E
1.
Install each unit as in a single installation. Install the two generators as close to each other as possible.
2. IMPORTANT NOTE Power must be disconnected at the main electrical supply before removing steam generator covers.
3. Connect the iSteam®or iTempo/Plus
™
control to either generator per the control instructions..
4. Remove one knock-out on each generator as shown. Insert the ends of interconnecting cable provided (PN 103904)
through the knock-outs as shown in the Diagram on page 5. Connect each end to the printed circuit board as shown.
5. Connect separate plumbing and power supplies for each unit.
Wiring Diagram MS-Super 4E, MS-Super 5E, MS-Super 6E
AutoFlush
(optional)
iTempo/Start
(optional)
iSteam or
iTempo/Plus
AutoFlush
(optional)
Do Not
Connect
Control
FACTORY
WIRING
FIELD
WIRING
LEGEND
(All Diagrams)
{
CONTACTOR
PRIMARY UNIT SECONDARY UNIT
AutoFlush
(optional)
Steam Genie
(optional)
iSteam or
iTempo/Plus
AutoFlush
(optional)
PLUG THIS END
TO MASTER UNIT
PRIMARY UNIT
SECOND UNIT
TO THIRD UNIT
TO FOURTH UNIT
TO FIFTH UNIT
Optional Tandem Cable for 2-5 Generators
Length is 30 ft. PN: 103917
OPTIONAL TANDEM CABLE
For connecting more than 2 steam generators in tandem
11
I N S T A L L E R
mr
.steam
®Installation, Operation & Maintenance Manual
__________________________________________________________________________
64604_Brochur _PUR100472A_10047213-02-1115:38Pag 13

INITIAL START-UP AND CHECKOUT
1. Turn on control. Follow specific instructions provided with controls.
2. Steam will begin to appear in approximately 5 minutes (unless equipped
with factory-installed Express Steam
option) at the steam head. Steam
will shut off when desired temperature is reached and will automatically
resume when room temperature drops below set point.
3. Steam will shut off automatically when control counts down to zero.
To shut steam off manually, turn control OFF. To clear steam from
enclosure area, turn shower on before opening door.
4. If unit does not start and control does not turn ON (control display
does not light up) then turn breaker off for 20 seconds and try again.
TROUBLESHOOTING
Step 1 Check main incoming power to the unit.
Step 2 Verify the transformer is receiving
208/240 VAC.
Step 3 Verify that you have 24VAC
coming out of the transformer, WHT &
WHT/BLU wires, into the board.
Step 4 Verify that you have the green
light on the PC board.
Step 5 Push the white test button to
run the generator for 10 minute test
cycle. Make sure the steamroom is
empty.
Step 6 Verify that you have 24 VAC
to the water feed solenoid, GRY &
WHT/GRY wires (will fill when needed).
Step 7 Temporarily short out the WLS (Purple wire) and
GND (Green wire) terminals and verify the contactor
engages.
Step 8 When the red light is on, verify 24 VAC,
RED & WHT/RED wires, to the contactor.
Step 9 Check main voltage on the
load side of the contactor when it is engaged.
Step 10 If all steps on the power path were verified, turn
off power to the unit and pull the heating element via
the left hand access panel for inspection.
OPTIONAL & ACCESSORY EQUIPMENT
Refer to specific instruction manual for installation, operation and maintenance of optional equipment
and accessories such as iSteam®,
iTempo/Plus™, iTempo™, Home Wizard™, iGenie™
and MSTS.
Do not disassemble internal components,
All drawings are for illustrative purposes only
internal components contain no serviceable parts.
12
I N S T A L L E R
mr
.steam
®Installation, Operation & Maintenance Manual
__________________________________________________________________________
WARNING
!
All electrical troubleshooting to be performed by a qualified licensed electrician
12
4
7
8
9
3
6
5
Transformer
Liquid Level
Control Board
Water Feed
Solenoid
Ste
Ou
Liquid
Level Probe
AutoFlush
and Play
Connectio
Contactor
Power Supply
Knock-Out Field Wiring
Water Feed
64604_Brochur _PUR100472A_10047213-02-1115:38Pag 14

mr
.steam
®Installation, Operation & Maintenance Manual
__________________________________________________________________________
I N S T A L L E R
13
SYSTEM STATUS CODES
The control (either iSteam®, iTempo
™
or iTempo/Plus
™
) may display a status code if the steam generator is not functioning properly.
Code Code Meaning Probable Cause Suggested Remedy
H20 Water level is not Water Supply is off Turn on Water Supply
satisfied within 5 min. Defective water feed solenoid Check/replace water solenoid valve
Water feed probe not functioning Check/clean probe.
Check probe wiring.
Drain Valve Open Check/Close drain valve
AutoFlush not functioning Check/Replace AutoFlush
Prr1 Temperature Probe Error Control cable/MSTS cable cut Replace control cable/MSTS
or Prr2 Internal problem with control/MSTS Replace control / MSTS
Err1 Incorrect Field Supply Voltage Incorrect voltage supplied Supply steam generator with the correct
(green light on liquid level to Generator voltage noted on the data plate label.
control board will be off)
Err2 Button on control is pressed Control cover misalignment Remove and reinstall control cover
for more than 5 minutes Debris behind control cover Remove control cover and clean cover,
control and keypad with a damp cloth
Errb Water level not satisfied in a tandem set up - Check secondary generators, see H20.
Err7 Liquid Level Control Board malfunction Memory error in LLCB Press ON/OFF to clear.
Replace control if code remains.
LIQUID LEVEL CONTROL BOARD Explanation of LED Indicators
______________________________________________________________________________________________________________________________________
GREEN LED is ON when there is 208/240 Volt incoming power connected,
24 Volt transformer secondary output and on-board 5 Volt DC control power are present.
______________________________________________________________________________________________________________________________________
YELLOW Water level indicator–LED is OFF when no water is detected (for more that 5 seconds). ON when
water level is satisfactory. For units with AutoFlush, if more than five hours have elapsed since
last usage and this LED is ON it is indicative of an AutoFlush or water level probe circuit malfunction.
______________________________________________________________________________________________________________________________________
RED Contactor relay indicator–LED is ON when relay is closed and sending 24 Volts to the
contactor coil. (This LED comes ON if the generator is ON.)
______________________________________________________________________________________________________________________________________
FORCE ON Press this button to operate the generator. This button is for trouble shooting only and will operate
TEST BUTTON
if a control is connected or not. Pressing the button again will shut the generator OFF. The test button
will only allow the generator to operate for 10 minutes.
Liquid Level Control Board
PN 103975
(shown without wiring)
RED (Heater)
YELLOW (Water Level)
GREEN (Power)
Force On
Test Button
All drawings are for illustrative purposes only
64604_Brochur _PUR100472A_10047213-02-1115:38Pag 15

I N S T A L L E R
14
I N S T A L L E R
OPTIONAL AUTOFLUSH
®
Box Contents
AutoFlush Valve with Cord
Installation Instructions.
OPERATION
The optional AutoFlush System feature automatically drains
the Mr.Steam generator following each use. A time delay
allows the water to cool down (about two hours) before it
drains by gravity for a safe and gentle operation.
NOTE
If the Express Steam®option has been installed, the
AutoFlush will drain for ten minutes then refill with fresh water
to begin the pre-heat cycle.
INSTALLATION INSTRUCTIONS
1. Plumbing to be performed by a qualified plumber and shall be in
accordance with applicable national and local codes. Unit drains
by gravity. A drain line that is lower than the AutoFlush
®
assembly
must be available. The AutoFlush System valve outlet is 1⁄2“ NPT.
Check plumbing code for receptor, trap and vent requirements.
2. Use copper or brass nipple 1⁄2“ NPT x 31⁄2“ or longer (not supplied)
to connect AutoFlush valve (end "B") to the Drain Valve (valve
end “A” and “B” are indicated on bottom of AutoFlush Valve)
DO NOT REMOVE THE DRAIN VALVE
Removal may cause equipment and property damage. If there is
not enough room for the valve, an elbow and a short nipple
(not provided) can be added.
3. Open Drain Valve (handle must be aligned with brass nipple).
4. Connect the AutoFlush System cord connector to the three pin
connector as shown.
Do not drain into a steam enclosure or any location
where accidental contact with drain water may occur. In the event
of a power failure the AutoFlush System valve will open and may
discharge boiling water causing a scalding hazard.
SWEAT FITTINGS
When using sweat fittings use only tin base solder with a melting
point below 600 degrees F. Do not overheat. Ends of water supply
tubing must be thoroughly clean for a minimum distance of 1" from
ends. Do not remove valve cover.
TO CHECK OPERATION
1. Turn on Mr.Steam and allow tank to fill with water.
2. Turn off Mr.Steam control. Water should stay in tank.
3. Turn off power at the panel box. Water should
discharge from tank.
4. Turn on power at panel box.
5. Repeat
PROVIDE DRAIN PLUMBING ACCORDING TO LOCAL
CODES. PLUMB AS REQUIRED FOR AUTOFLUSH SYSTEM.
Drain Valve
DO NOT TURN OR REMOVE
THE DRAIN VALVE
(shown in the correct open
position)
Nipple Plumb to
Drain Line
AutoFlush
Valve
AutoFlush Shown Fully Assembled
AutoFlush Cord
AutoFlush
Valve
3 Pin Connector
for AutoFlush
AutoFlush Cord
Connector
Drain Valve
(shown in the correct
open position)
DO NOT REMOVE
THIS DRAIN VALVE
Steam Generator
Nipple
copper or brass
nipple 1⁄2" NPT x 31⁄2" or
longer
(not supplied)
End
"A" End
"B"
Plumb to
Drain Line
Arrow indicates correct direction of flow
Steam Generator
CAUTION
!
CAUTION
!
WARNING
!
mr
.steam
®Installation, Operation & Maintenance Manual
__________________________________________________________________________
All drawings are for illustrative purposes only
64604_Brochur _PUR100472A_10047213-02-1115:38Pag 16

I N S T A L L E R
15
OPTIONAL DRIP PAN
Mr. Steam strongly recommends the use of a drip
pan in the unlikely event of a plumbing leak.
Locate the drip pan on a solid level surface and
place the steam generator inside the drip pan. Insure
the steam generator is level (see page 4 for locating
the steam generator).
All plumbing shall be performed by a qualified
licensed plumber and in accordance with applicable
national and local codes. Check local plumbing code
for receptor, trap and vent requirements. Drip pans
drain by gravity.
The drip pan is equipped with an integral female 3⁄4"
NPT fitting.
OPTIONAL EXPRESS STEAM
®
(only available factory installed)
Available for all MS Models. Express Steam genera-
tors are equipped with a low power heating element
and thermostat to keep the water in the tank warm
enough to bring up steam quicker. All Express Steam
components and wiring are installed at the factory.
No additional wiring or plumbing is required by
installers.
I N S T A L L E R
mr
.steam
®Installation, Operation & Maintenance Manual
__________________________________________________________________________
All drawings are for illustrative purposes only
64604_Brochur _PUR100472A_10047213-02-1115:38Pag 17

Transformer
Liquid Level
Control Board
Water Feed
Solenoid
Water Inlet
Safety Valve
AutoFlush
Valve
(optional)
Stainless Steel Tank
Heating Element
Express Steam
heater (optional)
Element
Access Cover
Liquid Level Probe
Plug and Play
Connection (see page 13)
Power Block
Power Supply
Knock-Out
Contactor
Steam Outlet
Fuses
Nipple
(not included)
Manual
Drain Valve
PARTS IDENTIFICATION DIAGRAM
MS REGULAR MODELS
MS65E - MS400E
(with AutoFlush™)
shown with cover removed
NOTE
FOR ILLUSTRATIVE PURPOSES ONLY.
Some components may be omitted or
altered for clarity. Do not use for wiring,
repair or other purposes not related to
component identification.
MS SUPER MODELS - MS SUPER 1E- MS SUPER 6E
(with AutoFlush™)
shown with cover removed
NOTE Super 1E 240/1
models are not supplied
with internal fusing.
NOTE
FOR ILLUSTRATIVE PURPOSES ONLY.
Some components may be omitted or
altered for clarity. Do not use for wiring,
repair or other purposes not related to
component identification.
Transformer
Drain Line
Nipple
(not included)
Liquid Level
Control Board
Water Feed
Solenoid
Water Inlet
Safety Valve
AutoFlush
Valve
(optional)
Stainless Steel Tank
Heating Element
Access Cover
Liquid Level Probe
Plug and Play
Connection (see page 13)
Contactor
Power Supply
Knock-Out
Steam Outlet
Express Steam
Heater (optional)
Manual
Drain Valve
16
mr
.steam
®Installation, Operation & Maintenance Manual
__________________________________________________________________________
I N S T A L L E R
64604_Brochur _PUR100472A_10047213-02-1115:38Pag 18

REPLACEMENT PARTS LIST
__________________________________________________________________________________________
Part No. Description Generator
___________________________________________________________________________________________
99178MS Drain Valve All Models
99297 Safety Valve 15PSI All Models
100479 Water Feed Solenoid Valve w/filter All Models
10477-3 Transformer 24VAC All Models
103975 Liquid Level Control Board All Models
103904 Tandem Cable for 2 generators (12 ft.) All Models
103917 Tandem Cable for up to 5 generators (30 ft.) All Models
103990-30 Cable for iTempo™Control (30 ft.) All Models
103990-60 Cable for iTempo™Control (60 ft.) All Models
104117-30 Cable for iSteam (30 ft.) All Models
MSTS Remote Temperature Probe for iTempo/Plus All Models
iMSTS Remote Temperature probe for iSteam®All Models
100476-2 Contactor 50A 2-pole MS 90E-400E, Single phase
99012 Contactor 50A 3-pole All 3-Phase Models
103453 Contactor 50A 4-pole MS Super-1E – Super-6E
100471-2 Probe Assembly All Models
99096MS Heating Element Gasket All Models
103938 Round Acrylic Shield iTempo & iTempo/Plus All Models
103938 Square Acrylic Shield iTempo & iTempo/Plus All Models
99314 Power Fuse 60A 250V MS-Super 1E–6E Single phase
29051BMS Heating Element 5 KW 208V MS 90E
29051CMS Heating Element 5 KW 240V MS 90E
29061BMS Heating Element 6 KW 208V MS 150E
29061CMS Heating Element 6 KW 240V MS 150E
29071BMS Heating Element 7.5 KW 208V MS 225E
29071CMS Heating Element 7.5 KW 240V MS 225E
29091BMS Heating Element 9 KW 208V MS 400E
29091CMS Heating Element 9 KW 240V MS 400E
29101BMS Heating Element 10 KW 208V MS SUPER-1E & MS Super-4E
29101CMS Heating Element 10 KW 240V MS SUPER-1E & MS Super-4E
29121BMS Heating Element 12 KW 208V MS SUPER-2E & MS Super-5E
29121CMS Heating Element 12 KW 240V MS SUPER-2E & MS Super-5E
29151BMS Heating Element 15 KW 208V MS SUPER-3E & MS Super-6E
29151CMS Heating Element 15 KW 240V MS SUPER-3E & MS Super-6E
104058 iGenie All Models
104059 iGenie Interface Module All Models
104060 iGenie Interface Cable (5 ft.) All Models
17
mr
.steam
®Installation, Operation & Maintenance Manual
__________________________________________________________________________
I N S T A L L E R
64604_Brochur _PUR100472A_10047213-02-1115:38Pag 19

CONTROL ROUGH IN
Refer to Installation Instructions for the specific control
1. Determine the desired installation location of the con-
trol. The iSteam®, iTempo™and iTempo/Plus™controls
are designed to be installed inside or outside the
steam room as a matter of personal preference. If the
control is installed inside the steam room the control
must be located
2. 4-5 feet above the floor near the bather seating area
3. The control features an integral temperature sensor.
Locate the control in a location representative of the
desired steambathing temperatures.
Do not locate the control above or near the steam
head or direct steam emissions.
4. on a vertical wall
The control cable length is 30 feet. Insure that the
control and/or steam generator are located accordingly.
An optional 60 foot cable is available (103990-60). Contact a
Mr. Steam technical service representative if a 60 foot cable is
required.
IMPORTANT NOTES
A 60 foot cable cannot be used with iSteam control.
If the control is installed outside the steamroom a Remote
Temperature Probe Part Number MSTS or iMSTS must be
installed inside the steam room, depending on the control.
Insure Mr.Steam steam generator is iSteam or iTempo compati-
ble and has a serial number 900000 or higher. If iSteam is used
with a generator having serial number 900000 through 930030,
contact Mr.Steam technical support for an upgraded PC board.
See instructions for the MSTS or iMSTS Temperature Probe
(located in the Control Installation Manual related to your specif-
ic control package) before rough-in or installation of control.
mr
.steam
®Installation, Operation & Maintenance Manual
__________________________________________________________________________
18
BEFORE INSTALLING
Turn power to the steam generator OFF before connecting the
control to the generator. Failure to turn the power off will result in
an inoperable control.
To avoid unintentional steambath operation,
do not locate the control where other controls, accessories,
shower heads, valves, body sprays or similar within the show-
er could cause confusion or interfere with the Mr.Steam con-
trol’s intended use and function.
Do not use any iSteam®, iTempo/Plus™,
iTempo™, HomeWizard™or iGenie®controls without reading
and understanding its own manual and the Mr.Steam steam
generator Installation and Operation Manual. Failure to read
and understand these instructions may result in an inopera-
tive or hazardous installation.
A peel and stick warning sticker must be read
and permanently affixed in a conspicuous location near the
steam room. Failure to read and affix this warning sticker in a
conspicuous location may result in serious injury or death. .
Install the iSteam, iTempo or iTempo/Plus controls according
to installation instructions. Failure to install according to
instructions will result in an inoperative control or hazardous
overheating or inadequate heating of the steam room.
If an iSteam, iTempo or iTempo/Plus control is installed out-
side the steam room a Remote Temperature Probe (PN MSTS
or iMSTS) must be installed inside the steam room per instal-
lation instructions supplied with the Remote Temperature
Probe. Failure to install according to instructions will result in
an inoperative control and overheating of the steam room.
CAUTION
!
CAUTION
!
WARNING
!
WARNING
!
I N S T A L L E R
Do not route iSteam, iTempo/Plus, iTempo,
HomeWizard or iGenie control wiring inside conduit
together with power lines or close to hot water or steam
piping. Doing so may result in an inoperative or hazardous
installation. Do not alter or modify any Mr. Steam products
including the steam generator, iSteam, iTempo/Plus,
iTempo, iGenie or HomeWizard controls. Doing so may
result in an inoperative or hazardous installation and will
void he warranty.
IMPORTANT NOTES
1. Turn power to the steam generator OFF before connect-
ing the control to the generator. Failure to turn the
power off will result in an inoperable control.
2. Do not operate iSteam, iTempo/Plus, iTempo,
HomeWizard or iGenie controls with other than a
Mr.Steam iSteam or iTempo compatible steam genera-
tor. Mr.Steam residential steam generators with serial
numbers lower than 900000, or any other brand of
steam generator are not to be operated with iTempo
controls. Doing so may result in an inoperative or haz-
ardous installation. If iSteam is used with a generator
having serial number 900000 through 930030, contact
Mr.Steam technical support for an upgraded PC board.
3. This document contains important safety, operation and
maintenance information. Leave this document with the
homeowner. Do not discard this document.
4. Discontinue use of the steam generator or control if the
steam generator is damaged or otherwise not function-
ing properly. Operating a damaged steam generator
may result in an inoperative or hazardous installation
CONTROL INSTALLATION
Refer to Control Manual for specific installation requirements
64604_Brochur _PUR100472A_10047213-02-1115:38Pag 20
This manual suits for next models
9
Table of contents
Other mr. steam Iron manuals

mr. steam
mr. steam MS-65T Owner's manual

mr. steam
mr. steam MS SUPER 6E User manual

mr. steam
mr. steam Steam@Home 3000 Instruction manual

mr. steam
mr. steam MS-90 Instruction manual

mr. steam
mr. steam CU Series User manual

mr. steam
mr. steam MS 81500SK User manual

mr. steam
mr. steam Steam@home SAH3000 Instruction manual

mr. steam
mr. steam MS Series Guide

mr. steam
mr. steam MS-90E User manual

mr. steam
mr. steam MS-65 Instruction manual