If acrylic, fiberglass or other non-heat resistant materials are used as
part of the steam room enclosure. Consult with the material manufac-
ture and see pg. 7, “Installing the Steamhead" for additional details.
IMPORTANT NOTES
This document contains important safety, operation and maintenance
information. Leave this document with the homeowner. Do not discard
this document.
The following general information should be used in conjunction with
consultations with an architect, designer and contractor in determining
factors necessary in providing a suitable and safe steam room.
Mr.Steam steam generators are intended to be operated with Mr.Steam
iSteam®, iTempo/Plus™, iTempo™Home Wizard™and iGenie®controls
only, and are to be installed strictly in accordance with the specific
instructions contained in this manual and as supplied in the manuals
provided with the controls or accessories.
Never use damaged equipment, doing so may result in an
inoperative or hazardous installation.
Discontinue use of the steam generator and control if the steam
generator or control are damaged or otherwise not functioning
properly. Doing so may result in an inoperative or hazardous
installation
ELECTRICAL SHOCK HAZARD. Mr.Steam steam generators are
connected to 240V line voltage and contain live electrical com-
ponents. All installation and service to be performed by quali-
fied and licensed electricians and plumbers only. installation or
service by unqualified persons or failure to use Mr. Steam parts
may result in property damage or in a hazardous condition.
The MS series of steam generators are for residential use only.
Commercial or other nonresidential applications void the war-
ranty and may adversely affect product performance and may
represent a safety hazard.
10. Limit steam room ceiling height to 8 feet. Exceeding
8 feet may require a higher-rated steam generator.
The peel and stick warning sticker provided in
the Steambath Generator Manual must be read and permanently
affixed in a conspicuous location near the steam room. Failure to
read and affix this warning sticker in a conspicuous location may
result in serious injury or death.
BEFORE INSTALLING
Carefully inspect the Steam Generator and packaging for
shipping damage. In the event of shipping damage,
please contact the carrier for claim information. Our
customer service department can assist you with any
missing or damaged parts.
Read these instructions before installation or service.
Although this MS steambath generator has been fully
qualified for shipment by Mr.Steam®, the following must
be reviewed for proper, safe and enjoyable steam bathing
1. Verify that the model and accessories specifications are
correct for the incoming line voltage.
2. Insure steambath generator has been correctly sized
STEAM ROOM GUIDELINES
1. Steam room must be completely enclosed, with full
walls, door, floor and ceiling.
2. It is recommended that a gasketed door is used for
steam containment.
3. If tile-type or other smooth surfaced flooring is used
provide suitable anti-skid strips or equivalent, to
prevent a slippery hazard.
4. Check the suitablility of any materials with the
manufacturer. Walls and ceilings must be constructed
of water-resistant, non-corrosive surface, such as tile,
marble, molded acrylic, or other non-porous material.
5. The ceiling should be sloped to prevent dripping of
condensate.
6. Provide a floor drain.
7. No heating, venting or air conditioning devices
should be installed inside the steam room.
8. Steam room tile construction information is
available from the Tile Council of America, Inc. by
purchasing the TCA Handbook for Ceramic Tile
Installation. Tel. (864) 646-8453 or www.tileusa.com.
9. Windows that are part of the steam room should be
double paned and tempered safety glass.
for the steambath room. Pay particular attention to room
volume and construction. If any questions, please refer
to Mr. Steam sizing and selection guide on page 2.
3. Marble or glass walls or ceilings. “ENLARGE” the room’s
size, requiring a generator larger than one based only on
the room’s cubic foot (L x H x W) volume.
4. The physical size of the unit, clearance for plumbing
servicing, and its distance from the steam room must all
be considered before final installation.
5. Consider any controls and accessories before initiating
installation. Read the Installation and Operation Manual
of all controls and accessories available at
www.mrsteam.com technical downloads.
Not Actual Size
REDUCE THE RISK OF OVERHEATING AND SCALDING
1.
EXIT IMMEDIATE Y IF UNCOMFORTAB E, DIZZY OR S EEPY.
STAYING TOO ONG IN A HEATED AREA IS CAPAB E OF CAUSING OVERHEATING.
2. CHI DREN UNDER THE AGE OF 16 SHOU D NOT USE THE STEAM BATH.
3. CHECK WITH A DOCTOR BEFORE USE IF PREGNANT, DIABETIC, IN POOR
HEA TH OR UNDER MEDICA CARE.
4. BREATHING HEATED AIR IN CONJUNCTION WITH CONSUMPTION OF A COHO ,
DRUGS, OR MEDICATION IS CAPAB E OF CAUSING UNCONSCIOUSNESS.
5. DO NOT CONTACT STEAM HEAD OR STEAM AT THE STEAM HEAD.
REDUCE THE RISK OF SLIPPING AND FALL INJURY
1.
USE CARE WHEN ENTERING OR EXITING THE STEAM ROOM. F OOR MAY BE S IPPERY.
NOTE: FOR ADDITIONA SAFETY CONSIDERATIONS SEE OWNER’S MANUA
mr
.steam®43-20 34th Street , ong Island City NY 11101 1 800 76 STEAM www.mrsteam.com PUR100378 6.4/08
WARNING
!
WARNING
!
WARNING
!
CAUTION
!
3
I N S T A L L E R
mr
.steam
®Installation, Operation & Maintenance Manual
__________________________________________________________________________
64604_Brochur _PUR100472A_10047213-02-1115:38Pag 5