MultiDyne SMPTE-HUT User manual

10 NEWTON PLACE
HAUPPAUGE, NY 11788 USA
877-685-8439 / 516-671-7278 / FAX 516-671-3362
www.multidyne.com
INSTRUCTION MANUAL
HUT
Hybrid Universal Transceiver
SMPTE Hybrid Cable Elimination System for Broadcast Camera Systems
MultiDyne
Harnessing The Power of Light

MULTIDYNE, the Multidyne logo,
are registered trademarks of MULTIDYNE Electronics, Inc.
Copyright 2019 MULTIDYNE Electronics, Inc., Hauppauge, New York.
Printed in the United States of America.
All Rights Reserved.
Contents of this publication may not be reproduced in any form without the written permission of
MULTIDYNE Electronics, Inc.
This product was designed and manufactured in the
UNITED STATES of AMERICA

INTRODUCTION..………….........………...….....…..……………………………………………….……..…..............……1
FEATURES AND OPERATION…...........…………………………………………..........…….......................………2 - 4
CAM HUT (CAM SIDE).............................………...........………..………..………..……….....………....…2
FRONT PANEL FEATURES..........................………...........………..………..………..……….....……….…2
OPTIONAL FRONT PANEL FEATURES....………...........………..………..………..……….....………....…3
REAR PANEL FEATURES..........................………...........………..………..………..……….....………....…3
CONFIGURING THE OPERATION VOLTAGE..........................………...........……….....………....…3
BASE (CCU SIDE) UNIT…………………………...............................………...........……….....……….…3 - 4
TECHNICAL SPECIFICATIONS......................….......………………………….........................………………....…5
TABLE OF CONTENTS

1SAFETY INFORMATION Instruction Manual, SMPTE HUT
Important Safety Information
• Read these instructions.
• Keep these instructions.
• Heed all warnings.
• Follow all instructions.
• Do not use this apparatus near water.
• Clean only with dry cloth.
• Do not block any ventilation openings. Install in accordance
with the manufacturer's instructions.
• Do not install near any heat sources such as radiators, heat
registers, stoves, or other apparatus (including amplifiers) that
produce heat.
• Do not defeat the safety purposes of the grounding-type plug. A
ground type plug has two blades and a third grounding prong. The
third prong is provided for your safety. If the provided plug does
not fit in to your outlet, consult an electrician for replacement of
the obsolete outlet.
• Protect the power cord from being walked on or pinching
particularly at plugs, convenience receptacles, and point where
they exit from the apparatus.
• Only use attachments/accessories specified by the manufacturer.
• Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used,
use caution when moving the cart/apparatus combination to avoid injury from tip-over.
• Unplug this apparatus during lightning storms or when unused for long periods of time.
• Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such
as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been
exposed to rain or moisture, does not operate normally, or has been dropped.
• Throughout this manual, a number of warning and caution notes may be presented to alert the user to important safety or operating
information. Please read and comply with any and all warning and caution notes in this manual.
• Always adhere to local building, safety and fire prevention codes during the installation and operation of this product.
• Use only power cords specified for this product and certified for the country of use.
• Connect the unit only to a power source with the specified voltage rating.
• Use only fuses of the type and rating specified.
• In case of an emergency ensure that power is disconnected.
Laser Safety Information
This unit is classified as a CLASS 1 LASER PRODUCT according
to EN60825-1 (EU) and FDA 21CFR 1040.10 (USA). Class 1 laser
products are considered safe and do not result in biological
hazard if used according to these instructions.
Warning –indicate danger that requires proper procedures or
practices to prevent injury or death to personnel.
Cautions indicate proper procedures or practices to prevent
damage to equipment or property.
Warning –The safe operation of this product requires that a protective
earth connection be provided. A grounding conductor in the equipment’s
mains supply cord provides this protective earth. To reduce the risk
of electrical shock to the operator and service personnel, this ground
conductor must be connected to an earthed ground. The mains plug shall
remain readily operable.
Warning –The apparatus shall not be exposed to dripping or
splashing and that no objects filled with liquids, such as vases,
shall be placed on the apparatus.
<2000m
Warning - This symbol on the equipment indicates for use at
altitudes not exceeding 2000 m.
Warning – Use of controls, adjustments or performance of
procedures other than those specified herein may result in
hazardous radiation exposure.
Warning – Never look directly into the end of the optical fiber
while either end of the system is operating.
Warning – Never clean an optical fiber connector on equipment or
cable that is carrying light.
Warning – Always use dust caps on fiber optic connectors when
cables are not connected. This will protect the connector from
damage and accidental exposure of a human eye to an operating
laser.

Instruction Manual, SMPTE HUT INTRODUCTION 2
INTRODUCTION
The SMPTE HUT system enables you to replace long runs of the
bulky and expensive hybrid fiber cable that connects your camera
and CCU with inexpensive fibers alone. It does this by moving
the camera power injection from the CCU side to the cam side.
It consists of a breakout adapter, known as the HUT-CCU, that
attaches to the SMPTE connector on your CCU. This enables you
to connect 2 fibers going to the cam side using ST connectors,
and it also tricks the CCU into thinking that your camera is still
attached by the hybrid fiber cable.
At the cam side of these fibers is the CAM HUT, which takes these
2 fibers with ST connectors and routes them to a SMPTE hybrid
fiber connector. It also plugs into local mains power and injects
230 VAC for your camera into that same SMPTE connector which
now connects to the camera via a much shorter length of hybrid
fiber cable. The CAM HUT performs the same safety checks on
this cable as your CCU does, and it optionally allows remote
powering down of your camera from the CCU side as well as
optical repeating and remapping of the wavelengths to and from
the CCU.
FEATURES AND OPERATION
CAM HUT (cam side) unit
The CAM HUT basic version is shown in Fig. 1. There are 3
versions of the CAM HUT, described below.
There are 2 versions of the CAM HUT, and each has its own front
panel. These are shown in Fig. 2. The basic configuration, which
is the first panel, is to have the SMPTE hybrid fiber connector
to the camera and the 2 ST/UPC or duplex LC fiber connectors
populated on the front panel. These are labeled FROM CCU
and TO CCU. Optionally, the optical connectors can be located
on the rear panel instead, as shown in Fig. 3. In systems with
the optional optical repeater, it is important that the user be sure
that his up-link and down-link signals are matched to the proper
connectors consistently throughout the link.
Front Panel
RESET: This button resets a 2A thermal circuit breaker in series
with the SMPTE hybrid connector output. In the event of an
over-current fault that causes power to the cam to be removed,
as evidenced by the HV PRES LED being dark, and the button
popped out. Pressing this button restores power after the fault
is removed. Note that RESET does not restore functionality if a
SMPTE cable fault exists.
SMPTE CABLE Status LEDs:
SHORT: Glows red upon short or leakage of hybrid fiber cable
to ground. Upon power up, this LED may glow red for a few
seconds even if no short exists. This is normal.
OPEN: Glows red when cable is open or cam not connected. If
using a Hitachi camera, be sure to set the CAM TYPE switches to
the Hitachi positions, to bypass the OPEN cable test. Otherwise,
it will always fail. For Panasonic, Sony or Ikegami, set switches
for those cameras.
OK: Glows green indicating a properly connected hybrid fiber
cable.
HV ENAB: Glows green when the HUT attempts to apply 230VAC
to the hybrid fiber cable. This occurs only after all cable checks
have been completed successfully.
HV PRES: Glows green when 230VAC is actually present on
the hybrid cable. If HV ENAB is green but HV PRESS is o,
check to see if the circuit breaker has been tripped. If so, the
RESET button may need to be pressed after removing the fault.
Otherwise, there could be a failure of either the HUT relays or
power transformer, and the HUT will require service.
CAM HUT
CAM TYPE: Selects cameras according to table below:
Switch A (leftmost) Switch B (rightmost)
Sony or Ikegami down down
Hitachi down up
Panasonic
3500 or 3800
up down
Panasonic
3000 or 5000
up up

3FEATURES & OPERATION Instruction Manual, SMPTE HUT
Optional Front Panel Features
If ordered with the optional Optical repeater, besides the features
of the basic unit, the front panel will have these additional
features as shown in the second panel:
Optical Status Leds:
If the complete optical repeater option that allows optical
remapping is fitted, there are 2 LEDs labeled FROM CCU and
TO CCU for the 2 optical fibers. Each glows red if the received
optical strength of its fiber is less than -18db, and green if greater.
However, if only the remote shutdown feature is fitted, only the
FROM CCU LED will be shown on the front panel. The TO CCU
fiber path will be entirely passive, and is passed straight thru the
CAM HUT.
REMOTE enable switch:
Set to on to enable the Cam HUT to prevent HV from being
applied to the camera if fiber FROM CCU is not illuminated. Fiber
FROM CCU is assumed to be the fiber up-linking from the base
to the camera. This eectively places the camera in standby,
as only standby voltage can be applied. If fiber FROM CCU is
illuminated, the Cam HUT will enable the application of HV if all
other cable checks have been passed. If the REMOTE switch is
set to o, this feature is bypassed and the application of HV will
be determined by the cable checks alone. Functionality will then
be identical to the basic unit.
Rear Panel Features
The rear panel is shown in Fig. 3. This drawing shows an
optional location of the optical connectors on the rear. The same
considerations concerning the fiber optic connectors should be
observed as on the front panel. Also on the rear is a fused, filtered
power entry module that accepts an IEC cord and a primary
power switch. If the optical connectors are located on the front
panel as shown in Fig. 2, then the rear would be completely
blank except for the power entry. If pressing the RESET button
after an over-current fault has occurred does not restore power,
please check the fuse.
Configuring the Operating Voltage:
The unit is configurable for either 115 or 230V operation. The
CAM HUT must be set for the correct mains voltage or damage
may result. The default configuration is for 115V operation. To
reconfigure the CAM HUT for a dierent mains voltage, using a
screwdriver, slide the red voltage select switch on the rear panel
to the correct mains voltage.
Base (CCU side) Unit
The Base unit, known as HUT-CCU, has a SMPTE hybrid receptacle
panel mount connector for connection to the CCU and 2 ST/UPC
or duplex LC connectors for the fibers to the CAM HUT. The base
unit is shown here in Fig. 4 with ST connectors As on the CAM
HUT, the ST or LC connectors are labeled either FROM CCU and
TO CCU. The same considerations concerning the fiber labels
should be observed, as on the CAM HUT.
The HUT-CCU acts as a breakout for the optical ports in the CCU
SMPTE connector. It also tricks the CCU into thinking a camera
is attached by a SMPTE hybrid fiber cable. This is necessary to
enable the CCU to leave standby mode so that it can accept video
from the camera. It has 2 LEDs located on the panel with the
ST connectors, labeled Power and HV. The Power LED is green
the CCU is supplying power to the HUT-CCU, and the HUT-CCU
is attempting to spoof the CCU. The HV LED is green when the
CCU is supplying high voltage. This means that the HUT-CCU has
successfully spoofed the CCU into thinking a camera is attached.
Otherwise, the CCU will not leave standby mode.
CAM HUT - front panel
CAM HUT - back panel
Base Unit

Instruction Manual, SMPTE HUT FEATURES & OPERATION 4
For proper operation, the HUT-CCU must be set for the type of camera system being used. There are 2 versions of HUT-CCU: one with
dip switches, and a rugged version with metal bat handle switches. Set the HUT-CCU for the camera type according to the following
tables:
CCU Unit (HUT BS)
Front Panel Camera Select DIP Switch Settings:
SW1 SW2 SW3 SW4 SW5 SW6 SW7
Ikegami down up up up down up up
Hitachi down up up up up up up
Sony down up up up up down down
Panasonic
3500 or 3800
up down up down up up up
Panasonic
3000 or 5000
down up down up up up up
CCU Unit (HUT BS)
Front Panel Camera Select BAT HANDLE Switch Settings:
SW1 SW3 SW4 SW5 SW6 SW7
Ikegami down up up down up up
Hitachi down up up up up up
Sony down up up up down down
Panasonic 3500
or 3800
up up down up up up
Panasonic 3000
or 5000
down down up up up up
Note there are only 6 switches in this version. SW2 is eliminated.

5TECHNICAL SPECIFICATIONS Instruction Manual, SMPTE HUT
Connections
SDI Standards Supported, repeater SMPTE 259M/292M/297M/425M, DVB/ASI
SDI Added Jitter, repeater < .03 UI, < 1 MHZ
Laser Safety, repeater Class 1
Optical Wavelengths, nm, repeater 1310. 1550 or CWDM optional
Optical Sensitivity, repeater -18 dBm
Optical Output Power, repeater -2 ~ -8 dBm
Fiber Optic cable length, standard Limited by camera/CCU
Fiber Optic cable length, repeater Up to 20km
Indicators, CAM HUT Unit, standard Cable open/short, HV/status
Indicators, CAM HUT Unit, repeater As above + optical power ok/bad/laserfail
Electrical Output, CAM HUT Unit 230VAC @ up to 250VA, active,
24VAC @ up to25VA, standby
Certifications FCC class B and UL/CE
Mechanical, Environmental
Dimensions (LxWxH), Weight
HUT-CP 11.25 x 5.75 x 3.5 inches, 10.3 lbs.
Operating Temperature 0 to 70 deg C
Power Requirement, CAM HUT Unit 115/230VAC, 50/60HZ, 260VA
Optical Connectors, CAM HUT SMPTE 311 Plug + 2 ST/UPC or LC
HUT-BS, BA, CS, CA 7 x 2.5 x 2 inches, 0.7 lb.
Power Requirement, HUT CCU Unit Uses power from CCU
Optical Connectors, HUT-CCU SMPTE 311 Receptacle + 2 ST/UPC or LC
Note: the length of hybrid cable that can be supported between the powered HUT and the camera is a function of many variables including
thickness of the hybrid cable, number of connections, and current draw of camera accessories and lens size/type/servo.
Table of contents