MUNBYN IPS01 User manual

Postal Scale
User Manual

CONTENTS
Preface 01
01
1. Product Introduction
02
2. Technical Data
02
02
03
03
04
04
05
07
07
08
09
3. Device Usage
4. FAQ
5. Support
3.1 Weighing
3.2 Mode
3.3 Hold Function
3.4 Tare
3.5 PCS
3.6 Calibration
3.7 Custom shutdown time
3.8 Error messages
PREFACE
1. PRODUCT INTRODUCTION
This user manual is designed to assist in the safe and trouble-free
use of the device. The product is designed and manufactured in
accordance with strict technical guidelines, using state-of-the-art
technologies and components.
User manual download link : https://munbyn.biz/901um
Postal scale
Adapter
Soft ruler
Battery
User manual
01

LCD Display
On/Off/Tare Button
MODE Button
PCS Button
OPEN
2. TECHNICAL DATA
3. DEVICE USAGE
Parameter description
Product name
Model
Load capacity [kg]
Unit
Button
Minimum weighing weight
Standby time
Power supply
Parameter value
Postal/Letter Scale
IPS01
30kg/66lb
g; lb; oz; kg; lb'oz;
On/Off/Tare Button; MODE Button; PCS Button;
5±1g
180s (default) (When the scale is powered on, the scale will not
automatically shut down)
1.5V×3AAA or AC adapter (110~240V AC to 6V DC)
3.1 Weighing
Weighing is the most basic function of this scale, and it can be used
to weigh up to 30kg. follow the steps below:
3.2 Hold Function
The hold function keeps the displayed data from disappearing,
which is convenient for recording.
3.3 Mode
The scale has five weighing units, namely kg/g/lb/oz/lb’oz, as shown
below:
Load the weight up, and after the weight value stabilizes, the
weight value will flash for 3 seconds and then automatically lock
(locked after second flash).
1. Place the scale on a flat surface.
2. Press the button and hold it until the value of 0.000kg is displayed.
3. Place the load on the scale; the weight value will be shown on
the display.
02 03

3.4 Tare
When using a container to weigh something, use this function to
subtract the weight of the container. as follows.
3.5 PCS
When you need to determine the number of multiple identical
parts, you can use the PCS function.
3.6 Calibration
Weighing errors will occur after the postal scale has been used
frequently for a long time and calibration is required when the
error exceeds the requirements.
1.In the weighing state, long-press the MODE button to display
the calibration units. (kg/lb). Such as:
You can calibrate with standard calibration weights.
Calibration weight Amazon purchase link:
https://www.amazon.com/-/zh/dp/B08R8KBVXC/ref=sr_1_42?
currency=USD&dchild=1&ie=UTF8&keywords=calibration&langua
ge=en_US&qid=1615604360&sr=8-42
1. In the weighing state, long-press the PCS button to enter the
sample number selection.
2. Press the MODE button to switch between 25/50/75/100, sample
size and load the sample after selection.
3. Short press the PCS button to confirm the number of samples,
then “PASS” will appear on the screen.
4. Place an unknown number of items to measur on the scale the
device will count them and display the quantity.
Tutorial Video: https://munbyn.biz/01pcs
1. Place an empty container on the scale.
2. Short press the button to subtract the tare, and the vlaue will be
cleared to 0.000kg.
3. Put the items to be weighed in the container.
Tutorial Video: https://munbyn.biz/01t
04 05

2. Short press the button to switch calibration units, then short
press the “MODE”button to confirm.
3. Short press the button to set the tens place, such as 12kg, 22kg,
etc.
4. Short press the PCS button to set the ones place, such as 3kg,
4kg, 5kg, etc. The setting method for English units is similar.
5. After setting the calibration weight, press the “MODE”button
to confirm the display of “CAL” and then the flashing calibration
weight will be displayed.
6. Load the weight. After the weight stabilizes, the actual weight
will be displayed after “PASS”is displayed.
Tutorial Video: https://munbyn.biz/01c
Tutorial Video: https://munbyn.biz/01st
3.7 Custom shutdown time
When powered by battery, you can customize the shutdown time
per the following steps:
3.8 Error messages
Overload:
Low battery :
1. In the zero state, long-press the button to enter the shutdown
time selection.
2. Press button to switch between "1" (minutes) , "3" (Minutes),
"5" (minutes) and “-”(No shutdown).
3. press the MODE button to confirm.
Note: When using the DC power supply, the scale does not
automatically shut down.
06 07

4. FAQ 5. SUPPORT
Q1: What is the calibration interval?
A1: 2-55lb/2-22kg.
Q2: How to exit function mode?
A2: To exit the function mode, press the button until the screen
turns off.
Q3: How long will the unit run on battery power?
A3: It is related to specific battery capacity. Theoretically,
a 175mAh AAA alkaline battery can be used continuously for
6 hours.
Q4: If the AC adapter and batteries are installed at the same
time, which one will be used?
A4: When using the adapter, it will automatically disconnect
the battery.
Q5: Waterproof performance
A5: The scale is splash-proof, but full immersion will damage the
equipment.
Need Tech Support ? contact us by:
Mail: [email protected]om
Whatsapp: +8617817881067
Skype: munbyn
Support time:Monday to Frida, 24 hours.